Sara A. Pozzi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sara A. Pozzi has a total of 157 co-authors. Here are the top co-authors by number of shared publications:
- Shaun D. Clarke
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
18 shared publications - Oskari Pakari
École Polytechnique Fédérale de Lausanne
8 shared publications - Flynn B. Darby
Los Alamos National Laboratory
6 shared publications - Abbas Johar Jinia
Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI, USA
5 shared publications - Ricardo Lopez
University of Michigan
5 shared publications - Igor Jovanovic
University of Michigan
4 shared publications
Latest Publications
- Open Access
- 2 July 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Rapid neutron and gamma-ray source localization using machine learning
- 2 July 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1092
Open AccessRapid neutron and gamma-ray source localization using machine learning
- Open Access
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (6)
Identifying neutron sources using recoil and time-of-flight spectroscopy
Identification of neutron sources is central to nuclear physics and its applications, from planetary science to nuclear security, yet direct source discrimination from measured neutron spectra remains fundamentally elusive. Here, we introduce a Bayesian protocol that directly infers source ensembles from measured neutron spectra by combining full-spectrum template matching with probabilistic evidence evaluation. Applying this protocol to recoil and time-of-flight spectroscopy, we recover single- and two-source configurations with strong statistical significance (beyond 4 σ ) at event counts as low as ∼ 10 3 . These results demonstrate that neutron spectral signatures can be leveraged for robust source identification, opening a new observational window for both fundamental research and operationally driven applications.
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (6)
Open AccessIdentifying neutron sources using recoil and time-of-flight spectroscopy
Identification of neutron sources is central to nuclear physics and its applications, from planetary science to nuclear security, yet direct source discrimination from measured neutron spectra remains fundamentally elusive. Here, we introduce a Bayesian protocol that directly infers source ensembles from measured neutron spectra by combining full-spectrum template matching with probabilistic evidence evaluation. Applying this protocol to recoil and time-of-flight spectroscopy, we recover single- and two-source configurations with strong statistical significance (beyond 4 σ ) at event counts as low as ∼ 10 3 . These results demonstrate that neutron spectral signatures can be leveraged for robust source identification, opening a new observational window for both fundamental research and operationally driven applications.
- Open Access
- 6 May 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1090
Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration
- 6 May 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1090
Open AccessImpact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration
- Open Access
- 12 March 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1088
Synchronization of neutron and gamma detector signals for noise studies
- 12 March 2026
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1088
Open AccessSynchronization of neutron and gamma detector signals for noise studies
- Open Access
- 22 December 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1085
Monitoring 135Xe after the shutdown of a research reactor using gamma-ray spectroscopy
- 22 December 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1085
Open AccessMonitoring 135Xe after the shutdown of a research reactor using gamma-ray spectroscopy
- Open Access
- 28 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (12) , 3835-3840
Neutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators
Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize in order to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239 keV, 338 keV, 583 keV and 911 keV. 244Cm was identified from emissions of 43 keV, 99 keV and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.
- 28 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (12) , 3835-3840
Open AccessNeutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators
Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize in order to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239 keV, 338 keV, 583 keV and 911 keV. 244Cm was identified from emissions of 43 keV, 99 keV and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (12) , 3830-3834
Assessing Age Effects on Pulse Shape Discrimination Capabilities of Organic Glass Scintillators
Organic glass scintillators (OGS) are useful tools in nuclear engineering for their ability to detect both fast neutrons and gamma-rays. However, over time, this material can undergo recrystallization which can impact detection efficiency and pulse shape discrimination (PSD) capabilities. An understanding of such changes is necessary for long-term applications of these materials. The University of Michigan Scintillator Laboratory is equipped [1]with capabilities to melt-cast Sandia National Laboratories’ small-molecule organic glass scintillators. Fifteen 6.35 x 6.35 x 6.35 mm3 OGS cube scintillators were melt-cast from OGS powder. Half of these were exposed to 50 °C for 448 hours to induce surface crystallization through accelerated aging. PVA coatings were used to help slow this process in several of these scintillators. Using the same readout and electronic system of a DT5730S CAEN digitizer and a 7.62 cm diameter photomultiplier tube, we measured a Cf-252 source with each cube individually to evaluate their pulse shape discrimination (PSD) capabilities. These measurements showed less than a 6% decrease in light output across all samples following aging. PSD capabilities are not greatly impacted with an average percent change of figure of merit in the 0.25 to 0.75 MeVee energy range.
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (12) , 3830-3834
Assessing Age Effects on Pulse Shape Discrimination Capabilities of Organic Glass Scintillators
Organic glass scintillators (OGS) are useful tools in nuclear engineering for their ability to detect both fast neutrons and gamma-rays. However, over time, this material can undergo recrystallization which can impact detection efficiency and pulse shape discrimination (PSD) capabilities. An understanding of such changes is necessary for long-term applications of these materials. The University of Michigan Scintillator Laboratory is equipped [1]with capabilities to melt-cast Sandia National Laboratories’ small-molecule organic glass scintillators. Fifteen 6.35 x 6.35 x 6.35 mm3 OGS cube scintillators were melt-cast from OGS powder. Half of these were exposed to 50 °C for 448 hours to induce surface crystallization through accelerated aging. PVA coatings were used to help slow this process in several of these scintillators. Using the same readout and electronic system of a DT5730S CAEN digitizer and a 7.62 cm diameter photomultiplier tube, we measured a Cf-252 source with each cube individually to evaluate their pulse shape discrimination (PSD) capabilities. These measurements showed less than a 6% decrease in light output across all samples following aging. PSD capabilities are not greatly impacted with an average percent change of figure of merit in the 0.25 to 0.75 MeVee energy range.
- Open Access
- 24 January 2025
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 200 (sup1)
Welch Method and Bootstrapping Applied to Subcritical Gamma Noise
- 24 January 2025
- Published by Taylor & Francis in Nuclear Science and Engineering
- Vol. 200 (sup1)
Open AccessWelch Method and Bootstrapping Applied to Subcritical Gamma Noise