AJAbbas Johar Jinia

Abbas Johar Jinia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abbas Johar Jinia has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measurement of Photoneutrons from Depleted Uranium and Comparison Study Using MCNPX-PoliMi

    by Abbas J. Jinia, Tessa E. Maurer, Christopher A. Meert, Shaun D. Clarke, Hun-Seok Kim, David D. Wentzloff, Sara A. Pozzi


  • Open Access

    Real-Time Classification of Radiation Pulses With Piled-Up Recovery Using an FPGA-Based Artificial Neural Network

    by Noah M. Michels, Abbas J. Jinia, Shaun D. Clarke, Hun-Seok Kim, Sara A. Pozzi, David D. Wentzloff

    Artificial neural networks (ANNs) have shown several benefits over the traditional classification methods for radiation detector data, such as greater accuracy and the ability to classify neutron-photon combinations from piled-up events. These capabilities are of particular interest in applications involving intense radiation environments where large instantaneous detector count rates can lead to many piled-up events and subsequent information loss. The recovery of individual radiation detector pulses from piled-up data can improve the efficiency of classification systems, making them more attractive for field applications. This work extends the use of ANN systems with piled-up recovery to the real-time domain, with a focus on hardware implementation. The ANN system is implemented on a Virtex-5 XC5VSX95T FPGA which collects pulse data at 250MHz and then processes and classifies pulses in the pipelined ANN at lower frequencies. The system’s performance is demonstrated by classifying pulses in real-time in a variety of scenarios including passive background, passive plutonium-beryllium (PuBe), and active PuBe. The results show that the system can provide accurate classifications in real-time while displaying the results clearly to the user. The system is shown to be capable of classifying pulses at a maximum rate of 1.11×10 6 pulses per second, a maximum latency of 7.7μs, and an overall accuracy of 98.2%.


  • Prompt Photofission Neutron Detection in Depleted Uranium

    by A.J. Jinia, T.E. Maurer, C.A. Meert, O.V. Pakari, S.D. Clarke, H.S. Kim, D.D. Wentzloff, S.A. Pozzi

    The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. This difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.


  • Open Access

    An Artificial Neural Network System for Photon-Based Active Interrogation Applications

    by Abbas J. Jinia, Tessa E. Maurer, Christopher A. Meert, Michael Y. Hua, S. D. Clarke, Hun-Seok Kim, David D. Wentzloff, Sara A. Pozzi

    Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and trans-stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile-up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252 Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 27% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 62.32% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252 Cf fission source.


  • Open Access

    Review of Sterilization Techniques for Medical and Personal Protective Equipment Contaminated With SARS-CoV-2

    by Abbas Johar Jinia, Noora Ba Sunbul, Christopher A. Meert, Cameron A. Miller, Shaun D. Clarke, Kimberlee J. Kearfott, Martha M. Matuszak, Sara A. Pozzi

    The outbreak of the novel coronavirus disease, COVID-19 turned into a global pandemic in March 2020. During these unprecedented times, there is an increased demand in medical and personal protective equipment (PPE). Since the supplies may take a long time to meet the global demand, reusing PPEs will help health care workers in their response to the COVID-19 pandemic. To ensure the safety and well-being of the medical first responders, PPE needs to be sterilized before reuse. In this review, we examine various sterilization techniques that can be used to sterilize PPEs and point out its limitations. The objective is to provide a foundation of knowledge incorporating different sterilization techniques that allow hospitals and clinics to pick the most suitable technique for sterilization of a particular PPE.