MTMin Tang

Min Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Min Tang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Kelsey J. Pieper

    Department of Civil and Environmental Engineering, Northeastern University, Boston, MA, USA

    4 shared publications
  • Darren A. Lytle

    Office of Research and Development (ORD), U.S. Environmental Protection Agency, 26 W. Martin Luther King Dr., Cincinnati, Ohio 45268, United States

    3 shared publications
  • Jeffrey Parks

    Civil and Environmental Engineering , Virginia Polytechnic Institute and State University , 418 Durham Hall , Blacksburg , Virginia 24061 , United States

    2 shared publications
  • Jeffrey Parks

    Department of Civil and Environmental Engineering Virginia Tech Blacksburg Virginia USA

    2 shared publications
  • Marc A. Edwards

    Civil and Environmental Engineering , Virginia Polytechnic Institute and State University , 418 Durham Hall , Blacksburg , Virginia 24061 , United States

    2 shared publications
  • Marc A. Edwards

    Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States

    2 shared publications

Latest Publications

  • Reviewing performance of NSF/ANSI 53 certified water filters for lead removal

    by Min Tang, Darren Lytle, Riley Achtemeier, Jennifer Tully


  • Open Access

    Utility considerations in developing a galvanized iron water pipe management plan

    by Marc Edwards, Roger Arnold, Becki Rosenfeldt, Sheldon V. Masters, Jeffrey Parks, Min Tang

    Galvanized iron pipe (GIP) was once widely installed in publicly and privately owned potable water systems. This antiquated plumbing material can cause water discoloration from iron release, head loss resulting from corrosion scale buildup, and occasional problems with lead (Pb) release to drinking water. In this work, a GIP management framework for utilities is formulated via a literature review and several case studies. The GIP management plan is intended to guide water systems with understanding and addressing GIP issues while considering consumer expectations, corrosion control challenges, variable performance, and associated cost–benefit analysis for corrective actions.


  • Lead pipe andlead–tinsolder scale formation and structure: A conceptual model

    by Vernon L. Snoeyink, Min Tang, Darren A. Lytle

    Lead–tin solder and lead service lines (LSLs) are important sources of lead, and after LSLs are removed, lead–tin solder will remain a major source of lead. A better understanding of the factors that control lead release from solder joints can help water utilities reduce lead. This paper reviews the reactions that take place at galvanic connections involving both lead–tin solder and lead pipe in contact with copper. A conceptual model based on these reactions was developed and is presented here to explain how such scale structure forms. The likely reactions that affect lead release for each of three cases, (1) no galvanic action, (2) lead anode and copper–brass cathode, and (3) lead cathode and copper–brass anode, are presented. The model also considers uniform corrosion that takes place on LSLs. This model should be useful when evaluating the impact of water quality changes on lead release from galvanic connections and LSLs.Article Impact Statement: The conceptual model sets the basis for water systems to anticipate the impact of water quality changes on lead release from lead surfaces.


  • Rapid and simple lead service line detection screening protocol using water sampling

    by Michael R. Schock, Darren A. Lytle, Ryan R. James, Vivek Lal, Min Tang

    Many water systems are challenged with uncertainty regarding service line material type. This work investigated using a simple drinking water flushed sampling approach and a more complicated and invasive sequential profile sampling approach to predict whether homes had an existing lead service line (LSL). Homes that never had an LSL (control groups) and homes with LSLs (study groups) in two communities having different degrees of corrosion control were sampled. Using control groups' results, community‐specific “threshold” lead levels were determined and compared to results from study groups. The flushed sampling maximum lead concentration (FMC) of lead accurately predicted 100% and 60% of LSL sites for the community with poor and good corrosion control, respectively. The weighted average sequential profile lead concentration (WASLC) increased the 40% not identified as LSL sites by fully flushed samples to 100%. The WASLC closely followed by the maximum sequential profile lead concentration were most reliable in identifying LSLs.


  • Open Access

    Tracking reduction of water lead levels in two homes during the Flint Federal Emergency

    by Anurag Mantha, Min Tang, Kelsey J. Pieper, Jeffrey L. Parks, Marc A. Edwards


  • Open Access

    Legionella pneumophila occurrence in drinking water supplied by private wells

    by K. Mapili, K. J. Pieper, D. Dai, A. Pruden, M. A. Edwards, M. Tang, W. J. Rhoads

    Unregulated private wells are understudied potential sources of community‐acquired Legionnaires’ disease. Here we conducted a comprehensive survey of 44 homes supplied by private wells in Wake County, North Carolina, quantifying Legionella spp. DNA, Legionella pneumophila DNA, and total bacterial 16S rRNA genes via real‐time polymerase chain reaction in hot and cold drinking water samples, along with culturable L. pneumophila via IDEXX Legiolert in cold drinking water samples. Legionella spp. DNA, L. pneumophila DNA and culturable L. pneumophila were detected in 100, 65·5 and 15·9% of the 44 homes, respectively, and culturable levels were comparable to some municipal surveys applying the same methods. Total coliforms and Escherichia coli were monitored as representative faecal indicators and were found in 20·4 and 0·0% of homes. Within certain sample types, Legionella spp. and L. pneumophila gene copy numbers were positively associated with total bacteria (i.e. total 16S rRNA genes) and water softener use, but were not associated with faecal indicator bacteria, inorganic water parameters or other well characteristics. These findings confirm that occurrence of Legionella and L. pneumophila is highly variable in private wells. Significance and Impact of the Study Legionella is the leading identified cause of waterborne disease outbreaks associated with US municipal water systems. While Legionella is known to occur naturally in groundwater, prior efforts to characterize its occurrence in unregulated private wells are limited to sampling at the wellhead and not in the home plumbing where Legionella can thrive. This work documents much higher levels of Legionella in home plumbing versus water directly from private wells and examines factors associated with higher Legionella occurrence.


  • Open Access

    Impact of Road Salt on Drinking Water Quality and Infrastructure Corrosion in Private Wells

    by Kelsey J. Pieper, Min Tang, Charles Nathan Jones, Stephanie Weiss, Andrew Greene, Hisyam Mohsin, Jeffrey Parks, Marc A. Edwards

    Increased road salt use and resulting source water contamination has widespread implications for corrosion of drinking water infrastructure, including chloride acceleration of galvanic corrosion and other premature plumbing failures. In this study, we utilized citizen science sampling, bench-scale corrosion studies, and state-level spatial modeling to examine the potential extent of chloride concentrations in groundwater and the resulting impact on private wells in New York. Across the sampled community, chloride levels varied spatially, with the highest levels in private wells downgradient of a road salt storage facility followed by wells within 30 m of a major roadway. Most well users surveyed (70%) had stopped drinking their well water for aesthetic and safety reasons. In the bench-scale experiment, increasing chloride concentration in water increased galvanic corrosion and dezincification of plumbing materials, resulting in increased metal leaching and pipe wall thinning. Our simple spatial analysis suggests that 2% of private wells in New York could potentially be impacted by road salt storage facilities and 24% could potentially be impacted by road salt application. Our research underscores the need to include the damage to public and privately-owned drinking water infrastructure in future discussion of road salt management.


  • Open Access

    Evaluating Water Lead Levels During the Flint Water Crisis

    by Kelsey J. Pieper, Rebekah L Martin, Min Tang, LeeAnne Walters, Jeffrey Parks, Siddhartha Roy, Christina L. Devine, Marc A. Edwards

    In April 2014, the drinking water source in Flint, Michigan was switched from Lake Huron water with phosphate inhibitors to Flint River water without corrosion inhibitors. The absence of corrosion control and use of a more corrosive source increased lead leaching from plumbing. Our city-wide citizen science water lead results contradicted official claims that there was no problem– our 90th percentile was 26.8 µg/L, which was almost double the Lead and Copper Rule action level of 15 µg/L. Back calculations of a LCR sampling pool with 50% lead pipes indicated an estimated 90th percentile lead value of 31.7 µg/L (±4.3 µg/L). Four subsequent sampling efforts were conducted to track reductions in water lead after the switch back to Lake Huron water and enhanced corrosion control. The incidence of water lead varied by service line material. Between August 2015 and November 2016, median water lead reduced from 3.0 to <1 µg/L for homes with copper service lines, 7.2 to 1.9 µg/L with galvanized service lines, and 9.9 to 2.3 µg/L with lead service lines. As of summer 2017, our 90th percentile of 7.9 µg/L no longer differed from official results, which indicated Flint’s water lead levels were below the action level.