Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Li-Feng Wang has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Noise analysis of non-reciprocal parity-time symmetric micromechanical system

    by Rui Wang, Lei Han, Man-Na Zhang, Li-Feng Wang, Qing-An Huang

  • Open Access

    Enhanced sensitivity in nonlinear parity-time symmetric silicon micromechanical resonators

    by Yu-Jue Xie, Li-Feng Wang, Man-Na Zhang, Rui Wang, Qing-An Huang

    Silicon resonant sensors are essential to a wide range of applications that involve the detection of pressure, acceleration, and magnetic fields. In general, they operate by monitoring a shift in the resonant frequency of silicon micromechanical resonators when subjected to perturbations due to the aforementioned parameters. This frequency shift manifests as a linear dependence on the perturbation. The demand for ever more precise silicon resonant sensors has catalyzed research endeavors aimed at boosting their sensitivity beyond geometrical constraints, including attempts to utilize synchronization phenomenon in coupled silicon resonators. Here, we establish and experimentally demonstrate a method using non-Hermitian singularities, or an exceptional point (EP), to amplify sensitivity. This method reveals that the frequency shift in nonlinear parity-time symmetric silicon micromechanical resonators exhibits a cubic root singularity of perturbations. In the small perturbation limits, we observe an increase in sensitivity by several orders of magnitude when compared to traditional configurations. Our findings pave the way towards the next generation of ultrasensitive silicon resonant sensors.


  • Novel non-invasive glucose concentration sensor by phase shift of patch antenna

    by Shasha Yang, Shiwen Gao, Yi Zhuang, Lifeng Wang, Zhenxiang Yi, Lei Wang


  • Open Access

    Correction: Wang et al. Temperature Effects in Packaged RF MEMS Switches with Optimized Gold Electroplating Process. Micromachines 2024, 15, 1085

    by Lifeng Wang, Lili Jiang, Ning Ma, Xiaodong Huang

    It was found that the temperature control of the electroplating station in the previously published paper

  • Open Access

    Abnormal trend for noninvasive BGL sensors using phase shift technology

    by Shasha Yang, Shiwen Gao, Yi Zhuang, Lifeng Wang, Zhenxiang Yi

    For the first time, this paper finds and investigates the abnormal trend for the noninvasive detection of blood glucose levels (BGLs) based on phase technology. To support the findings, the basic microwave structure of a grounded coplanar waveguide (GCPW) was utilized. In the theoretical research, a GCPW material under test transmission line model was developed to analyze how the dielectric properties of glucose solutions impact the surface electric field distribution of the GCPW. From this model, we derived the relationship between the phase shift of the GCPW and the dielectric properties of the glucose solution, revealing that an inverse trend may appear at different frequency points. The simulation results obtained through the finite element method aligned well with the theoretical analysis, showing a strong correlation between the phase shift of the S parameters and the concentration of the glucose solution. After the test platform was established, preliminary experiments were conducted when the BGLs were varied from 0 to 8.57 mg/ml. The results demonstrate that the phase shift of S11 is highly correlated with glucose concentration. Specifically, at the frequency of 2.27 GHz, the phase shift decreases as glucose concentration increases, whereas at 2.80 GHz, the phase shift increases with rising glucose concentration. Additionally, a linear regression prediction model was proposed to enhance the practical feasibility for noninvasive BGLs’ measurement in future applications.

  • Open Access

    Enhanced sensitivity in nonlinear parity-time symmetric silicon micromechanical resonators

    by Qing-An Huang, Yu-Jue Xie, Li-Feng Wang, Man-Na Zhang, Rui Wang

    Silicon resonant sensors are essential to a wide range of applications that involve the detection of pressure, acceleration, and magnetic fields. In general, they operate by monitoring a shift in the resonant frequency of silicon micromechanical resonators when subjected to perturbations due to the aforementioned parameters. This frequency shift manifests as a linear dependence on the perturbation. The demand for ever more precise silicon resonant sensors has catalyzed research endeavors aimed at boosting their sensitivity beyond geometrical constraints, including attempts to utilize synchronization phenomenon in coupled silicon resonators. Here we establish and experimentally demonstrate a method using non-Hermitian singularities, or exceptional points, to amplify sensitivity. This method reveals that the frequency shift in nonlinear parity-time symmetric silicon micromechanical resonators exhibits a cubic root singularity of perturbations. In the small perturbation limits, we observe an increase in sensitivity by several orders of magnitude when compared to traditional configurations. Our findings pave the way towards the next generation of ultrasensitive silicon resonant sensors.

  • Robust Wireless Temperature Sensing With High Resolutions Based on LC Fano Resonance

    by Lei Dong, Xi-Fan Gao, Li-Feng Wang, Qing-An Huang

    LC passive wireless sensors are excelling in wearable devices with the advantages of wireless sensing and compatibility with multiple fabrication processes. Classical LC sensing systems faces the challenges of misdiagnose at different interrogation distances since the frequency detection of the Lorentzian resonance is affected by the mutual coupling. Here we propose the asymmetric LC Fano resonance to improve the robust wireless interrogation by detecting the peak and valley frequencies simultaneously, making the frequency calibration insensitive to coupling coefficient. To form the asymmetric Fano-resonance in an LC wireless sensing system, we introduce a negative impedance compensation to the classical LC temperature sensor embedded in a wearable bandage. A sharp resonant peak is generated and able to be detected by coupling to a continuum resonance provided by an external readout. Moreover, high temperature resolutions are observed by monitoring the peak and valley frequencies of Fano resonance. We test the wearable temperature sensing bandages from 36 to 42°C to imitate healing and inflammation process. Compared to the traditional LC sensors with Lorentz resonance, the Fano-resonant sensor features coupling-independent interrogation and possesses temperature resolutions as high as 0.07°C. The proposed Fano-resonant LC wireless sensing system provides a potential approach for robust wearable sensing systems with high resolutions.


  • Multifunctional Metasurfaces for Multispectral Infrared Detection With Radiative Cooling

    by Yaoyao Xu, Pengfei Zhang, Yao Ma, Jun Liu, Liyan Zhu, Lifeng Wang, Xiaodong Huang

    Infrared detection is promising for aircraft surveillance. The stealth aircraft displays intense radiation characteristics in the two long-wave infrared frequency ranges (8.02- $8.58~\mu $ m and 9.24- $9.96~\mu $ m). Therefore, it is quite important to enhance the detection precision in these two ranges. In addition, camouflage of the infrared detector itself requires low emissivity in the long-wave-infrared range. Moreover, in order to cool down the infrared detector, it is desirable to increase emissivity in the 5- $8~\mu $ m non-atmospheric window. In this work, a multifunctional metasurface with the Au/SiO2/Au thin film structure is designed and prepared. The structure exhibits high emissivity of 0.65 and 0.72 in the aircraft detection windows (8.02- $8.58~\mu $ m and 9.24- $9.96~\mu $ m) while maintaining low emissivity of 0.23 outside the detection windows for IR stealth. It also achieves high emissivity, with a maximum value of 0.65 and an average value of 0.38, in the non-atmospheric window (5- $8~\mu $ m) for thermal management. Exploration in the physical mechanisms of the compatible metasurface is conducted and discussed that the periodic array metal structure at the top layer allows the frequency selectivity while the metal/insulator/metal (MIM) structure localizes the incident wave under the synergistic effect of the intrinsic properties of materials and local surface plasmon, resulting in resistance losses. This work might bring more opportunities in military fields for optimizing multispectral infrared detection, device camouflage and radiation transmission signal processing.


  • Open Access

    A Compact Wideband Vivaldi Antenna for Non-Invasive Glucose Monitoring

    by Shasha Yang, Yu Wang, Shiwen Gao, Yi Zhuang, Lifeng Wang, Zhenxiang Yi, Weixun Zhang

    Due to the high gain, wide bandwidth, and directional radiation characteristics of Vivaldi antennas, this paper conducted relevant research on the feasibility of non-destructive blood glucose detection based on Vivaldi antennas. The research included finite element method (FEM) simulation and glucose concentration monitoring. In the simulation stage, the power transmission and reflection characteristics, radiation characteristics, and electric field distribution characteristics of the antenna were described in detail. In the test stage, the S11 response of the antenna to variation in glucose concentration in the range of 0–6.11 mg/mL was measured, including the S11 amplitude and phase. The experimental results show that there is a high linear correlation between the S11 response and glucose concentration, and the sensitivity of the S11 amplitude response to the variation in glucose concentration is close to 0.3445 (dB/(mg/mL)) at 14.2556 GHz, and the sensitivity of the S11 phase response to the variation in glucose concentration is about 0.5652 (degree/(mg/mL)) at 14.37 GHz. In addition, the predicted results of the glucose concentration based on linear regression are discussed.


  • Open Access

    Strain-Induced Frequency Splitting in PT Symmetric Coupled Silicon Resonators

    by Lifeng Wang, Shangyang Zhang, Qunce Yuan

    When two resonators of coupled silicon resonators are identical and the gain on one side is equal to the loss on the other side, a parity-time (PT) symmetric-coupled silicon resonator is formed. As non-Hermitian systems, the PT-symmetric systems have exhibited many special properties and interesting phenomena. This paper proposes the strain-induced frequency splitting in PT symmetry-coupled silicon resonators. The frequency splitting of the PT system caused by strain perturbations is derived and simulated. Theory and simulation both indicate that the PT system is more sensitive to strain perturbation near the exceptional point (EP) point. Then, a feedback circuit is designed to achieve the negative damping required for PT symmetry. Based on a simple silicon-on-insulator (SOI) process, the silicon resonator chip is successfully fabricated. After that, the PT-symmetric-coupled silicon resonators are successfully constructed, and the frequency splitting phenomenon caused by strain is observed experimentally.