A Compact Wideband Vivaldi Antenna for Non-Invasive Glucose Monitoring
Open Access
- 16 November 2024
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 15 (11) , 1389
Abstract
Due to the high gain, wide bandwidth, and directional radiation characteristics of Vivaldi antennas, this paper conducted relevant research on the feasibility of non-destructive blood glucose detection based on Vivaldi antennas. The research included finite element method (FEM) simulation and glucose concentration monitoring. In the simulation stage, the power transmission and reflection characteristics, radiation characteristics, and electric field distribution characteristics of the antenna were described in detail. In the test stage, the S11 response of the antenna to variation in glucose concentration in the range of 0–6.11 mg/mL was measured, including the S11 amplitude and phase. The experimental results show that there is a high linear correlation between the S11 response and glucose concentration, and the sensitivity of the S11 amplitude response to the variation in glucose concentration is close to 0.3445 (dB/(mg/mL)) at 14.2556 GHz, and the sensitivity of the S11 phase response to the variation in glucose concentration is about 0.5652 (degree/(mg/mL)) at 14.37 GHz. In addition, the predicted results of the glucose concentration based on linear regression are discussed.Keywords
Funding Information
- National Natural Science Foundation of China (62371127)
This publication has 25 references indexed in Scilit:
- Electromagnetic Wave Sensors for Noninvasive Blood Glucose Monitoring: Review and Recent DevelopmentsIEEE Transactions on Instrumentation and Measurement, 2023
- Highly Stretchable Wearable Electrochemical Sensor Based on Ni-Co MOF Nanosheet-Decorated Ag/rGO/PU Fiber for Continuous Sweat Glucose DetectionAnalytical Chemistry, 2021
- Non-Invasive Fluidic Glucose Detection Based on Dual Microwave Complementary Split Ring Resonators With a Switching Circuit for Environmental Effect EliminationIEEE Sensors Journal, 2020
- Global and regional diabetes prevalence estimates for 2019 and projections for 2030 and 2045: Results from the International Diabetes Federation Diabetes Atlas, 9th editionDiabetes Research and Clinical Practice, 2019
- Non-invasive, transdermal, path-selective and specific glucose monitoring via a graphene-based platformNature Nanotechnology, 2018
- A Glucose Sensing System Based on Transmission Measurements at Millimetre Waves using Micro strip Patch AntennasScientific Reports, 2017
- A Noninvasive Measurement of Blood Glucose Concentration by UWB Microwave SpectrumIEEE Antennas and Wireless Propagation Letters, 2016
- Design and In Vitro Interference Test of Microwave Noninvasive Blood Glucose Monitoring SensorIEEE Transactions on Microwave Theory and Techniques, 2015
- On the Opportunities and Challenges in Microwave Medical Sensing and ImagingIEEE Transactions on Biomedical Engineering, 2015
- A reusable robust radio frequency biosensor using microwave resonator by integrated passive device technology for quantitative detection of glucose levelBiosensors and Bioelectronics, 2015