PRPeter D. Ross

Peter D. Ross

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Peter D. Ross has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Xanthomatous hypophysitis causing hypogonadotropic hypogonadism resulting in delayed presentation of slipped capital femoral epiphysis

    by Kirit Singh, Avinash Kumar Kanodia, Peter Ross, Antonia Torgersen, Jamie Maclean, Graham Leese, Kismet Hossain-Ibrahim

    An 18-year-old man who underwent bilateral pinning of his hip joints after a left unstable Slipped Capital Femoral Epiphysis (right pinned prophylactically) was noted to have delayed secondary sexual characteristics and post-operative diabetes insipidus. The patient also described a history of fatigue, headache and polydipsia for the past 4 years. Endocrine investigations revealed reduced androgen levels, hypocortisolism, a borderline normal Serum ACE and secondary hypothyroidism. Magnetic Resonance Imaging of the pituitary gland identified an enhancing mass and a thickened stalk which trans-nasal endoscopic biopsy found to be necrotic with pus. Histology confirmed a diagnosis of Xanthomatous Hypophysitis, an inflammatory condition likely related to a partial rupture of a Rathke cleft cyst. The patient was subsequently commenced on Androgen, Thyroxine, Desmopressin and Hydrocortisone therapy with on-going endocrine follow-up. Although endocrine dysfunction & hypogonadism has been recognised to be a risk factor for SCFE at an atypically older age, due to reduced androgen levels leading to a weakened physeal plate, this is the first known case of a Xanthomatous Hypophysitis resulting in pituitary dysfunction and eventual SCFE. This case highlights that an increased range of pituitary disorders should be considered in late presentations of SCFE; and vice versa the risk of SCFE should be considered in patients with prolonged hypogonadotropic hypogonadism.


  • Mucosal and lacrimal flaps for endonasal dacryocystorhinostomy: a systematic review

    by R. Green, R. Gohil, P. Ross

    Background: Historically dacryocystorhinostomy (DCR) has been performed externally with very good outcomes. Current literature shows comparable success rates between endonasal and external approaches. A common reason for the failure of a DCR is the reclosure of the nasolacrimal stoma by granulation tissue and synechiae.Objective of review: A systematic review and critical evaluation of the evidence relating to the preservation of nasal mucosal flaps in DCR surgery.Type of review and evaluation method: A systematic review using the consort guidance for review of randomised control trials.Search strategy: A search of the following evidence‐based medicine databases was performed: Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effectiveness, Cochrane Central Register of Controlled Trials, Ovid, Medline, EMBASE and PubMed. The search was limited to English language articles, and the following key words were used: Endonasal, Endoscopic, Dacryocystorhinostomy, DCR, Mucosal Flaps, between years 1970 and 2015.Results: The best available evidence was level 1B, comprising two randomised control trials and three comparative studies included in the review. The main outcome measures used were lacrimal irrigation and absence of epiphora. Two of the studies demonstrated a statistically significant benefit of mucosal sparing either with nasal mucosal flaps or with lacrimal flaps. More debridement was needed, and granulation tissue was also seen in the groups without mucosal preservation. There was no difference in surgical complications between a mucosal and non‐mucosal‐sparing technique.Conclusions: The overall quality of current evidence is poor, and there does however appear to be a trend towards improved outcomes and reduced granulation in groups where nasal mucosal and lacrimal flaps were preserved, but this is not clear‐cut. There was no evidence of increased complication rates with mucosal‐sparing techniques. We recommend that until further good quality research is available we should be performing a mucosal‐sparing technique when performing DCR routinely.


  • Computer-assessed performance of psychomotor skills in endoscopic otolaryngology surgery: construct validity of the Dundee Endoscopic Psychomotor Otolaryngology Surgery Trainer (DEPOST)

    by Peter D. Ross, Richard Steven, Dong Zhang, Heng Li, Eric W. Abel

    This study was undertaken to introduce and establish the value of the Dundee Endoscopic Psychomotor Otolaryngology Surgery Trainer (DEPOST) as a customisable, objective real-time scoring system for trainee assessment. The construct validity of the system was assessed by comparing the performance of experienced otolaryngologists with that of otolaryngology trainees, junior doctors and medical students. Forty two subjects (13 Consultants, 8 senior trainees, 13 junior trainees and 8 junior doctors/medical students) completed a single test on DEPOST. The test involved using a 30° rigid endoscope and a probe with position sensor, to identify a series of lights in a complex 3-dimensional model. The system scored subjects for time, success rate, and economy of movement (distance travelled). An analysis of variance and correlation analysis were used for the data analysis, with statistical significance set at 0.05. Increasing experience led to significantly improved performance with the DEPOST (p p p p = 0.051) The system provides an accurate and customisable assessment of endoscopic skill in otolaryngologists. The DEPOST system has construct validity, with master surgeons and senior trainees completing the tasks more accurately without sacrificing execution time, success rate or efficiency of movement.


  • The impact of Scottish Government protocols on practice in Scotland

    by P R C Steele, M L Barnes, P D Ross

    Objectives: : To investigate rates of septorhinoplasty and rhinoplasty in Scotland between 2006 and 2010, and to establish the impact of government legislation.Methods: : Data on the rates of rhinoplasty and septorhinoplasty were collected and analysed according to specialty, region and year.Results: : In 2006, 754 septorhinoplasty and rhinoplasty cases were recorded (147 per million population), rising to 893 (171 per million population) in 2010. Mean annual rates per million population were 152 (87 per cent of procedures) in ENT, 13.9 (8 per cent) in plastic surgery and 8.7 (8 per cent) in oromaxillofacial surgery. After 2009, there was a 43 per cent reduction in the rhinoplasty rate (p < 0.0001), although the oromaxillofacial surgery rate increased by 68 per cent (p < 0.05). Over the same period, the septorhinoplasty rate increased in ENT (46 per cent, p < 0.0001), and declined in plastic surgery (24 per cent, p = 0.49) and oromaxillofacial surgery (45 per cent, p = 0.05). Overall, the rate for rhinoplasty plus septorhinoplasty only declined by 1 per cent. There was significant regional variation.Conclusion: : Overall, septorhinoplasty rates have increased and rhinoplasty rates have decreased. There was only a 1 per cent decrease in the overall rate following the 2009 legislation. Practice differs between regions.


  • Measuring the Forces of Middle Ear Surgery; Evaluating a Novel Force-Detection Instrument

    by Michael Bergin, Michael Sheedy, Peter Ross, Grant Wylie, Philip Bird

    The forces applied to the middle ear structures during surgery are measurable. Surgical forces applied to the middle ear are often cited as a cause of postoperative sensorineural hearing loss; however, no literature exists on how much total force is applied during common middle ear procedures. Using our novel middle ear surgical force sensor, we took measurements from 6 temporal bones of common middle ear manipulations. Temporal bones of 3 males and 3 females yielded 72 measurements for an average peak applied force and 68 measurements for total applied force across 3 levels of operator experience. Statistically significant differences were seen between different levels of operator and how much force was applied, with senior operators using less force. We show it is possible to measure the applied forces in middle ear surgery and that some of these forces are very large. Larger forces are seen in destructive procedures and in procedures performed by inexperienced operators. This project is an important first step in investigating the association between surgically applied middle ear forces and postoperative sensorineural hearing loss.


  • Automatic glare removal in endoscopic imaging

    by Eric W. Abel, Yuan Zhuo, Peter D. Ross, Paul S. White

    Glare from surgical instruments and tissue surfaces often occurs during endoscopic procedures and can be disturbing to the operator. The brightness level of the light source can be reduced, but at the expense of overall image clarity, so alternative solutions are needed for removing glare. Digital image-processing methods offer the opportunity to lessen or eliminate glare by reducing the intensity of the affected parts of the image. This study investigated a new automated method for glare reduction that uses two different intensity thresholds as a basis for applying glare reduction processes and it also reduces unpleasant artifacts at the glare region boundaries. The new glare-reduction method was compared with a previous method. Three variants of each method, each with different color biases in the glare regions, were applied to a 20-s surgical recording containing substantial amounts of glare. The six versions and the original recording were evaluated subjectively by a group of 10 experienced surgeons using a paired-comparisons method, in which each version was compared for preference with all the other versions. The new double-threshold intensity-subtraction method scored significantly higher than the previously developed glare-reduction method (p < 0.05). It also scored higher than the original (unprocessed) version, but not significantly. The color bias was important, with combinations of pink and grey performing better than yellow tints. The findings show the new method to be a significant improvement in automatic glare reduction compared with earlier methods. The method is not computationally demanding, so it can in the future be evaluated clinically in high-definition endoscopic imaging systems and developed further in this environment.


  • Development of a surgical instrument for measuring forces applied to the ossicles of the middle ear

    by Michael Sheedy, Mike Bergin, Grant Wylie, Peter Ross, Richard Dove, Phil Bird

    Surgery of the middle ear is a delicate process that requires the surgeon to manipulate the ossicles, the smallest bones in the body. Excessive force applied to the ossicles can easily be transmitted through to the inner ear which may cause a permanent sensorineural hearing loss. An instrument was required to measure the forces applied to cadaveric temporal bone ossicles with the vision of measuring forces in vivo at a later stage. A feasibility study was conducted to investigate a method of measuring force and torque applied to the ossicles of the middle ear. Information from research papers was gathered to determine the expected amplitudes. The study looked at commercially available transducers as well as constructing an instrument using individual axis transducers coupled together. A prototype surgical instrument was constructed using the ATI industrial automation Nano17 six axis transducer. The Nano17 allows for the measurement of force and torque in the X, Y and Z axis to a resolution of 1/320 N. The use of the Nano17 enabled rapid development of the surgical instrument. It meets the requirements for its use on cadaveric models and has the potential to be a useful data collection tool in vivo.


  • Open Access

    Measurement of Osteotomy Force during Endoscopic Sinus Surgery

    by Paul Joice, Peter D. Ross, Dong Wang, Eric W. Abel, Paul S. White

    Greater understanding of the surgeon's task and skills are required to improve surgical technique and the effectiveness of training. Currently, neither the objective measurement of osteotomy forces during endoscopic sinus surgery (ESS) nor the validity of the properties of cadaver materials, are well documented. Measurement was performed of peak axial osteotomy force during ESS. A comparison was made of results with previously published cadaver data to validate the force properties of cadaver models. A prospective, consecutive cohort of 25 patients was compared with data from 15 cadaver heads. A modified Storz sinus curette measured osteotomy force from uncinate, bulla ethmoidalis, and ground lamella. Independent variables were osteotomy site, age, gender, indication for surgery, and side. Corresponding cadaver data were analyzed for the independent variables of osteotomy site, side, and gender and then compared with the live patient data. Mean osteotomy force in live patients was 9.6 N (95% CI, 8.9–10.4 N). Mean osteotomy force in the cadaver heads was 6.4 N (95% CI, 5.7–7.0 N). Ethmoid osteotomy of live patients required 3.2 N (95% CI, 2.1–4.3 N) more force than the cadaver heads (p = 0.0001). This relationship was statistically significant at the bulla ethmoidalis (p = 0.002) and the ground lamella (p = 0.0001) but not at the uncinate (p = 0.068). Osteotomy in female live subjects required 1.6 N (95% CI, 0.1–3.1 N) more force than male live subjects (p = 0.03). Cadaver tissue may underestimate the mean osteotomy force required in osteotomy of living ethmoid sinus lamellae by a factor of 1.5 times. Caution may be required in extrapolating force estimates from cadaver tissue to those required in living patients.


  • Surgical Instrument Force Exerted during Endoscopic Sinus Surgery: Differences within the Ethmoid Sinus Complex

    by Peter D. Ross, Paul Joice, Ramez G. Nassif, Paul S. White

    Background: Endoscopic sinus surgery (ESS) has been the most important technical advance in surgical rhinology in the last 25 years. The technique is now used beyond its initial sinus confines but knowledge of the forces required to perform ESS is limited. Greater understanding of these forces will lead to improved surgical training and safety. The aim of this study was to quantify the magnitude of the forces exerted during punch osteotomy of the bony lamella of the paranasal sinuses and surrounding bony structures during ESS. Methods: Fifteen formalin-fixed cadaveric heads underwent simulated ESS. Peak axial forces were measured using a pair of modified Blakesley forceps. Measurements were recorded during osteotomy of the paranasal sinus complex, skull base, and crests of the optic nerve and internal carotid artery. Statistical comparison between the mean forces was performed. Results: A mean force of 6.06 N was required to breach the lamellae of the ethmoid sinus complex. This was significantly less than the mean force required to breach the skull base, excluding the olfactory cleft (17.80 N; p < 0.0001), crests of the optic nerve (15.43 N; p < 0.001), and internal carotid artery (13.15 N; p < 0.001). There was no significant difference between the ethmoid lamella and the lamina papyracea (6.13; p = 0.67). Conclusion: Significantly greater force was required to breach the skull base and other safety critical areas encountered in ESS, than the bony lamellae of the ethmoid sinus complex. Although this result is reassuring, in vivo studies are now required to validate this relationship in the operative patient.