Frank M. Gerner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Frank M. Gerner has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Junwoo Suh
Univ Cincinnati, Sch Dynam Syst, Cincinnati, OH 45221 USA
3 shared publications- Ahmed Shuja
BritePointe, Inc., Hayward, CA 94541
1 shared publication Alexzandra Spatholt
University of Cincinnati, Cincinnati, OH 45221, USA
1 shared publicationAndrew Gorton
University of Cincinnati, Cincinnati, OH 45221, USA
1 shared publicationChang-Lin Tien
1 shared publicationDebra Cytrynowicz
Midwest Micro Devices, Toledo, OH 43604 USA
1 shared publication
Latest Publications
- 1 January 2023
- Published by Begell House Inc. Publishers
- p. 263-270
EFFECTS OF HIGH INTERFACIAL SHEAR STRESS DUE TO COUNTERCURRENT VAPOR FLOW ON FILM CONDENSATION HEAT TRANSFER
The heat transfer characteristics of a two-phase closed thermosyphon are experimentally investigated. Results indicate that, in the condenser, a large countercurrent vapor flow exerts a high interfacial shear stress upon the liquid film, which thickens the film and inhibits heat transfer. Both flat-plate and control-volume analyses predict similar results.
- 1 January 2023
- Published by Begell House Inc. Publishers
- p. 263-270
EFFECTS OF HIGH INTERFACIAL SHEAR STRESS DUE TO COUNTERCURRENT VAPOR FLOW ON FILM CONDENSATION HEAT TRANSFER
The heat transfer characteristics of a two-phase closed thermosyphon are experimentally investigated. Results indicate that, in the condenser, a large countercurrent vapor flow exerts a high interfacial shear stress upon the liquid film, which thickens the film and inhibits heat transfer. Both flat-plate and control-volume analyses predict similar results.
- 1 April 2017
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 114, 281-295
Simplified Mathematical Model of a novel ‘Closed Loop Two-Phase Wicked Thermosyphon (CLTPWT)’
- 1 April 2017
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 114, 281-295
Simplified Mathematical Model of a novel ‘Closed Loop Two-Phase Wicked Thermosyphon (CLTPWT)’
- 28 December 2012
- Published by Wiley in Journal of Heat Transfer
- Vol. 135 (2) , 021401
Charging Station of a Planar Miniature Heat Pipe Thermal Ground Plane
Thermal ground planes (TGPs) are planar, thin (thickness of 3 mm or less) heat pipes which use two-phase heat transfer. The objective is to utilize TGPs as thermal spreaders in several microelectronic cooling applications. TGPs are innovative high-performance, integrated systems able to operate at a high power density with a reduced weight and temperature gradient. Moreover, being able to dissipate large amounts of heat, they have very high effective axial thermal conductivities and can operate in high adverse gravitational fields due to nanoporous wicks. A key factor in the design of the TGP is evacuation prior to filling and introduction of the proper amount of working fluid (water) into the device. The major challenge of this work is to fill heat pipes with a total liquid volume of less than 1 ml, without being able to see into the device. The current filling station is an improvement over the current state of the art as it allows for accurate filling of microliter sized volumes. Tests were performed to validate performance of the system and to verify that little to no noncondensable gasses were introduced to the system. Careful calibration of the amount of liquid introduced is important. Therefore, calibration of the burettes utilized for a liquid fill range of 0.01 ml to 100 ml was important. The magnitude of the pressure inside the TGP device is also an important factor. Charging station validation demonstrated the capability of charging TGPs with accuracy of ±1.64 μl. Calibration curves for the burettes and error characterization curves for a range of liquid charging volumes will be presented and discussed in this paper.
- 28 December 2012
- Published by Wiley in Journal of Heat Transfer
- Vol. 135 (2) , 021401
Charging Station of a Planar Miniature Heat Pipe Thermal Ground Plane
Thermal ground planes (TGPs) are planar, thin (thickness of 3 mm or less) heat pipes which use two-phase heat transfer. The objective is to utilize TGPs as thermal spreaders in several microelectronic cooling applications. TGPs are innovative high-performance, integrated systems able to operate at a high power density with a reduced weight and temperature gradient. Moreover, being able to dissipate large amounts of heat, they have very high effective axial thermal conductivities and can operate in high adverse gravitational fields due to nanoporous wicks. A key factor in the design of the TGP is evacuation prior to filling and introduction of the proper amount of working fluid (water) into the device. The major challenge of this work is to fill heat pipes with a total liquid volume of less than 1 ml, without being able to see into the device. The current filling station is an improvement over the current state of the art as it allows for accurate filling of microliter sized volumes. Tests were performed to validate performance of the system and to verify that little to no noncondensable gasses were introduced to the system. Careful calibration of the amount of liquid introduced is important. Therefore, calibration of the burettes utilized for a liquid fill range of 0.01 ml to 100 ml was important. The magnitude of the pressure inside the TGP device is also an important factor. Charging station validation demonstrated the capability of charging TGPs with accuracy of ±1.64 μl. Calibration curves for the burettes and error characterization curves for a range of liquid charging volumes will be presented and discussed in this paper.
- 26 November 2010
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 20 (12)
A MEMS bubble pump for an electronic cooling device
- 26 November 2010
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 20 (12)
A MEMS bubble pump for an electronic cooling device
- 20 December 2009
- Published by American Chemical Society (ACS)
- p. 49-64
Vertical Integration of Nanotechnology Education
- 20 December 2009
- Published by American Chemical Society (ACS)
- p. 49-64
Vertical Integration of Nanotechnology Education
- 1 January 2005
- Published by ASME International
- p. 737-742
Operating Ranges of the Planar Loop Heat Pipe Under Non-Vacuum Conditions
As the trend of high throughput in small packages continues, the heat dissipation becomes a very critical design issue in electronic devices and spacecrafts. The two phase loop heat pipe utilizes the latent heat of working fluid. It consists of an evaporator, compensation chamber, condenser, and liquid and vapor line. The primary wick used as a core part to circulate the working fluid is located in the evaporator. The planar loop heat pipe uses coherent porous silicon (CPS) wick as opposed to the conventional cylindrical configuration, which uses a sintered amorphous metal wick. The clear evaporator machined from Pyrex glass and transparent silicone tubes were utilized to monitor the complex phenomena which occur in the evaporator. Tests were conducted under the non-vacuum condition without a secondary wick. DI-water was used as a working fluid. Like an open loop test previously conducted, there was an operating range in which the liquid could be properly pumped from the compensation chamber to the vapor line under the pumping motion. In this device, more than 6 Watts could be convected from the evaporator to the ambient. Therefore circulation was not observed until powers greater than 6 Watts. There was a circulation of working fluid occurring due to energy transport within the loop when the input power was from 7.94 Watts to 17.6 Watts. The quantity of heat transportation to the loop was calculated by acquiring the empirical heat transfer coefficient. From this calculation it was found that, roughly, 12.1 Watts was transported to the loop and 5.51 Watts was convected to the ambient from the evaporator itself when the applied power was 15.27 Watts. This paper was also originally published as part of the Proceedings of the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems.
- 1 January 2005
- Published by ASME International
- p. 737-742
Operating Ranges of the Planar Loop Heat Pipe Under Non-Vacuum Conditions
As the trend of high throughput in small packages continues, the heat dissipation becomes a very critical design issue in electronic devices and spacecrafts. The two phase loop heat pipe utilizes the latent heat of working fluid. It consists of an evaporator, compensation chamber, condenser, and liquid and vapor line. The primary wick used as a core part to circulate the working fluid is located in the evaporator. The planar loop heat pipe uses coherent porous silicon (CPS) wick as opposed to the conventional cylindrical configuration, which uses a sintered amorphous metal wick. The clear evaporator machined from Pyrex glass and transparent silicone tubes were utilized to monitor the complex phenomena which occur in the evaporator. Tests were conducted under the non-vacuum condition without a secondary wick. DI-water was used as a working fluid. Like an open loop test previously conducted, there was an operating range in which the liquid could be properly pumped from the compensation chamber to the vapor line under the pumping motion. In this device, more than 6 Watts could be convected from the evaporator to the ambient. Therefore circulation was not observed until powers greater than 6 Watts. There was a circulation of working fluid occurring due to energy transport within the loop when the input power was from 7.94 Watts to 17.6 Watts. The quantity of heat transportation to the loop was calculated by acquiring the empirical heat transfer coefficient. From this calculation it was found that, roughly, 12.1 Watts was transported to the loop and 5.51 Watts was convected to the ambient from the evaporator itself when the applied power was 15.27 Watts. This paper was also originally published as part of the Proceedings of the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems.
- 1 January 2005
- Published by Begell House Inc. Publishers in Annual Review of Heat Transfer
- Vol. 14 (14) , 313-333
MICROSCALE HEAT PIPES
- 1 January 2005
- Published by Begell House Inc. Publishers in Annual Review of Heat Transfer
- Vol. 14 (14) , 313-333
MICROSCALE HEAT PIPES
- 1 April 1999
- Published by Elsevier in International Journal of Heat and Fluid Flow
- Vol. 20 (2) , 149-157
Developing convective heat transfer in deep rectangular microchannels
- 1 April 1999
- Published by Elsevier in International Journal of Heat and Fluid Flow
- Vol. 20 (2) , 149-157
Developing convective heat transfer in deep rectangular microchannels
- 1 November 1993
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 20 (6) , 771-781
Using fiber optics to tap the sun's power
- 1 November 1993
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 20 (6) , 771-781
Using fiber optics to tap the sun's power