Ahmed Shuja
Ahmed Shuja has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Frank M. Gerner
Department of Mechanical & Materials Engineering, University of Cincinnati, Cincinnati, OH 45221, USA
1 shared publication - Frank M. Gerner
Microscale Heat Transfer Laboratory, Department of Mechanical & Materials Engineering, College of Engineering and Applied Science, University of Cincinnati, 565 Rhodes Hall, Cincinnati, OH 45220, USA
1 shared publication H. Thurman Henderson
University of Cincinnati, Cincinnati, OH
1 shared publicationJunwoo Suh
University of Cincinnati, Cincinnati, OH
1 shared publication- Karthik S. Remella
Department of Mechanical & Materials Engineering, University of Cincinnati, Cincinnati, OH 45221, USA
1 shared publication Praveen Medis
University of Cincinnati, Cincinnati, OH
1 shared publication
Latest Publications
- 28 February 2017
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (6) , 062901
Mathematical Modeling of Novel Two-Phase Heat Transfer Device for Thermal Management of Light Emitting Diodes
The paper introduces a novel two-phase heat transfer device (TPHTD) which is employed in the thermal management of light emitting diodes (LEDs). The heat transfer device structurally resembles a conventional loop heat pipe (LHP) without a compensation chamber, but operates very differently from it. The device is comprised of a central evaporator package and a circular coil that acts as a heat exchanger loop. The working fluid leaving the evaporator has a two-phase mixture quality of approximately 0.2. Having introduced the device, the paper delineates a mathematical model for predicting its thermal performance. The primary objective of the model is to provide a fundamental understanding of the operation of the device. A one-dimensional thermal resistance model (TRM) is utilized in modeling the evaporator. The paper presents a detailed discussion on obtaining these resistances from experiments conducted on the device. A correlation for the external heat transfer coefficient of the heat exchanger loop is proposed based on experiments and is found to be in good agreement with literature. The model predicts performance parameters such as board temperature, two-phase mixture quality, and saturation and subcooled temperatures (Tsat and Tsc) of the working fluid for different input thermal powers (Qtot). Based on experimental evidence, it is concluded that the majority of Qtot (∼75%) is utilized in phase change of the working fluid, and the rest reheats the working fluid from a lower subcooled temperature (Tsc) to the saturation temperature (Tsat) of the evaporator.
- 28 February 2017
- Published by Wiley in Journal of Heat Transfer
- Vol. 139 (6) , 062901
Mathematical Modeling of Novel Two-Phase Heat Transfer Device for Thermal Management of Light Emitting Diodes
The paper introduces a novel two-phase heat transfer device (TPHTD) which is employed in the thermal management of light emitting diodes (LEDs). The heat transfer device structurally resembles a conventional loop heat pipe (LHP) without a compensation chamber, but operates very differently from it. The device is comprised of a central evaporator package and a circular coil that acts as a heat exchanger loop. The working fluid leaving the evaporator has a two-phase mixture quality of approximately 0.2. Having introduced the device, the paper delineates a mathematical model for predicting its thermal performance. The primary objective of the model is to provide a fundamental understanding of the operation of the device. A one-dimensional thermal resistance model (TRM) is utilized in modeling the evaporator. The paper presents a detailed discussion on obtaining these resistances from experiments conducted on the device. A correlation for the external heat transfer coefficient of the heat exchanger loop is proposed based on experiments and is found to be in good agreement with literature. The model predicts performance parameters such as board temperature, two-phase mixture quality, and saturation and subcooled temperatures (Tsat and Tsc) of the working fluid for different input thermal powers (Qtot). Based on experimental evidence, it is concluded that the majority of Qtot (∼75%) is utilized in phase change of the working fluid, and the rest reheats the working fluid from a lower subcooled temperature (Tsc) to the saturation temperature (Tsat) of the evaporator.
- 1 January 2005
- Published by ASME International
- p. 737-742
Operating Ranges of the Planar Loop Heat Pipe Under Non-Vacuum Conditions
As the trend of high throughput in small packages continues, the heat dissipation becomes a very critical design issue in electronic devices and spacecrafts. The two phase loop heat pipe utilizes the latent heat of working fluid. It consists of an evaporator, compensation chamber, condenser, and liquid and vapor line. The primary wick used as a core part to circulate the working fluid is located in the evaporator. The planar loop heat pipe uses coherent porous silicon (CPS) wick as opposed to the conventional cylindrical configuration, which uses a sintered amorphous metal wick. The clear evaporator machined from Pyrex glass and transparent silicone tubes were utilized to monitor the complex phenomena which occur in the evaporator. Tests were conducted under the non-vacuum condition without a secondary wick. DI-water was used as a working fluid. Like an open loop test previously conducted, there was an operating range in which the liquid could be properly pumped from the compensation chamber to the vapor line under the pumping motion. In this device, more than 6 Watts could be convected from the evaporator to the ambient. Therefore circulation was not observed until powers greater than 6 Watts. There was a circulation of working fluid occurring due to energy transport within the loop when the input power was from 7.94 Watts to 17.6 Watts. The quantity of heat transportation to the loop was calculated by acquiring the empirical heat transfer coefficient. From this calculation it was found that, roughly, 12.1 Watts was transported to the loop and 5.51 Watts was convected to the ambient from the evaporator itself when the applied power was 15.27 Watts. This paper was also originally published as part of the Proceedings of the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems.
- 1 January 2005
- Published by ASME International
- p. 737-742
Operating Ranges of the Planar Loop Heat Pipe Under Non-Vacuum Conditions
As the trend of high throughput in small packages continues, the heat dissipation becomes a very critical design issue in electronic devices and spacecrafts. The two phase loop heat pipe utilizes the latent heat of working fluid. It consists of an evaporator, compensation chamber, condenser, and liquid and vapor line. The primary wick used as a core part to circulate the working fluid is located in the evaporator. The planar loop heat pipe uses coherent porous silicon (CPS) wick as opposed to the conventional cylindrical configuration, which uses a sintered amorphous metal wick. The clear evaporator machined from Pyrex glass and transparent silicone tubes were utilized to monitor the complex phenomena which occur in the evaporator. Tests were conducted under the non-vacuum condition without a secondary wick. DI-water was used as a working fluid. Like an open loop test previously conducted, there was an operating range in which the liquid could be properly pumped from the compensation chamber to the vapor line under the pumping motion. In this device, more than 6 Watts could be convected from the evaporator to the ambient. Therefore circulation was not observed until powers greater than 6 Watts. There was a circulation of working fluid occurring due to energy transport within the loop when the input power was from 7.94 Watts to 17.6 Watts. The quantity of heat transportation to the loop was calculated by acquiring the empirical heat transfer coefficient. From this calculation it was found that, roughly, 12.1 Watts was transported to the loop and 5.51 Watts was convected to the ambient from the evaporator itself when the applied power was 15.27 Watts. This paper was also originally published as part of the Proceedings of the ASME 2005 Pacific Rim Technical Conference and Exhibition on Integration and Packaging of MEMS, NEMS, and Electronic Systems.