Joyce J. B. C. van Beers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Joyce J. B. C. van Beers has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jan Damoiseaux
Central Diagnostic Laboratory, Maastricht University Medical Center, Maastricht, The Netherlands
5 shared publications Christopher Krause
Institute for Experimental Immunology, EUROIMMUN Medizinische Labordiagnostika AG, Seekamp 31, 23560, Lübeck, Germany
1 shared publication- Douwe de Boer
Unit of Clinical Chemistry, Central Diagnostic Laboratory, Maastricht University Medical Centre+, Maastricht; and
1 shared publication E. A. M. Beckers
Department of Internal Medicine, Subdivision Hematology, Maastricht University Medical Center, Maastricht, the Netherlands
1 shared publicationGer H Koek
Department of Internal Medicine, Division of Gastroenterology and Hepatology, Maastricht University Medical Center, Maastricht, The Netherlands
1 shared publicationH. M. H. Spronk
Laboratory for Clinical Thrombosis and Haemostasis, Department of Internal Medicine, Cardiovascular Research Institute Maastricht, Maastricht University Medical Center, Maastricht, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 5 September 2024
- Published by MDPI AG in Antibodies
- Vol. 13 (3) , 73
Therapeutic Drug Monitoring of Infliximab and Adalimumab through Concentration and Anti-Drug Antibodies Assessment; Comparison of Sanquin Diagnostics and Theradiag Assays
Background: Therapeutic drug monitoring of biological Tumor Necrosis Factor (TNF)-alpha inhibitors is of critical importance. In this study, the performance of practically advantageous chemiluminescent immunoassays of Theradiag, assessing Infliximab and Adalimumab serum concentrations and anti-drug antibodies (ADA) against these biologics, were compared to the Enzyme-Linked Immuno-Sorbent Assays (ELISAs) from Sanquin Diagnostics. Methods: Leftover serum samples (n = 80 for each parameter) from patients treated with Infliximab or Adalimumab were collected. Correlation and agreement analyses for serum concentration and ADAs, respectively, were performed. Both Theradiag ADA assays, an assay targeting both free and bound ADAs and an assay targeting solely free ADAs, were investigated and compared to the Sanquin Diagnostics ADA assay, targeting both free and bound ADAs. Results: Strong positive correlations were observed between the biologic concentration assessment of Infliximab (Spearman’s Rho = 0.91) and Adalimumab (Spearman’s Rho = 0.94). However, there appeared to be significant bias in the Theradiag assay when compared to Sanquin (Infliximab median (Confidence Interval (CI)) = 2.1 (1.7–2.6) µg/mL; Adalimumab median (CI) = 0.8 (0.5–0.9) µg/mL). Agreement analyses showed moderate to good agreement for the Theradiag and Sanquin Diagnostics ADA assays, when detecting both free and bound ADAs, for Infliximab (Cohen’s k = 0.717) and Adalimumab (Cohen’s k = 0.802). In contrast, the Theradiag ADA assay detecting solely free ADAs had zero to poor agreement for Infliximab (Cohen’s k = 0.458) and Adalimumab (Cohen’s k = 0.119), respectively. Conclusions: This study demonstrated strong correlations and good agreement between the Theradiag and Sanquin Diagnostics assays measuring Infliximab and Adalimumab serum concentrations and ADAs, both free and bound, against these biologics. Discordance analyses showed significantly decreased drug concentrations in the solely free assays, indicating that the combined detection of free and bound ADAs better aligns with drug levels.
- 5 September 2024
- Published by MDPI AG in Antibodies
- Vol. 13 (3) , 73
Open AccessTherapeutic Drug Monitoring of Infliximab and Adalimumab through Concentration and Anti-Drug Antibodies Assessment; Comparison of Sanquin Diagnostics and Theradiag Assays
Background: Therapeutic drug monitoring of biological Tumor Necrosis Factor (TNF)-alpha inhibitors is of critical importance. In this study, the performance of practically advantageous chemiluminescent immunoassays of Theradiag, assessing Infliximab and Adalimumab serum concentrations and anti-drug antibodies (ADA) against these biologics, were compared to the Enzyme-Linked Immuno-Sorbent Assays (ELISAs) from Sanquin Diagnostics. Methods: Leftover serum samples (n = 80 for each parameter) from patients treated with Infliximab or Adalimumab were collected. Correlation and agreement analyses for serum concentration and ADAs, respectively, were performed. Both Theradiag ADA assays, an assay targeting both free and bound ADAs and an assay targeting solely free ADAs, were investigated and compared to the Sanquin Diagnostics ADA assay, targeting both free and bound ADAs. Results: Strong positive correlations were observed between the biologic concentration assessment of Infliximab (Spearman’s Rho = 0.91) and Adalimumab (Spearman’s Rho = 0.94). However, there appeared to be significant bias in the Theradiag assay when compared to Sanquin (Infliximab median (Confidence Interval (CI)) = 2.1 (1.7–2.6) µg/mL; Adalimumab median (CI) = 0.8 (0.5–0.9) µg/mL). Agreement analyses showed moderate to good agreement for the Theradiag and Sanquin Diagnostics ADA assays, when detecting both free and bound ADAs, for Infliximab (Cohen’s k = 0.717) and Adalimumab (Cohen’s k = 0.802). In contrast, the Theradiag ADA assay detecting solely free ADAs had zero to poor agreement for Infliximab (Cohen’s k = 0.458) and Adalimumab (Cohen’s k = 0.119), respectively. Conclusions: This study demonstrated strong correlations and good agreement between the Theradiag and Sanquin Diagnostics assays measuring Infliximab and Adalimumab serum concentrations and ADAs, both free and bound, against these biologics. Discordance analyses showed significantly decreased drug concentrations in the solely free assays, indicating that the combined detection of free and bound ADAs better aligns with drug levels.
- Open Access
- 29 August 2023
- Published by Elsevier in Journal of Immunological Methods
- Vol. 522, 113552
Identifying therapeutic monoclonal antibodies using target protein collision electrophoresis reflex assay to separate the wheat from the chaff
- 29 August 2023
- Published by Elsevier in Journal of Immunological Methods
- Vol. 522, 113552
Open AccessIdentifying therapeutic monoclonal antibodies using target protein collision electrophoresis reflex assay to separate the wheat from the chaff
- Open Access
- 13 April 2022
- Published by Elsevier in Journal of Translational Autoimmunity
- Vol. 5, 100155
Anti-Sm antibodies in the classification criteria of systemic lupus erythematosus
- 13 April 2022
- Published by Elsevier in Journal of Translational Autoimmunity
- Vol. 5, 100155
Open AccessAnti-Sm antibodies in the classification criteria of systemic lupus erythematosus
- Open Access
- 1 January 2022
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 7 (1) , 259-267
The Role of Autoantibodies in the Diagnosis of Autoimmune Liver Disease: Lessons Learned from Clinical Practice
Background: Primary biliary cholangitis (PBC), autoimmune hepatitis (AIH) and primary sclerosing cholangitis (PSC) are autoimmune liver diseases associated with distinct autoantibodies. Diagnosis is based upon clinical, serological, and histopathology findings. The role of autoantibodies in the diagnosis of these autoimmune liver diseases, with the focus on PBC and AIH, will be discussed. Content: When AIH or PBC is suspected, testing for multiple autoantibodies can be requested. In this mini-review, the different ways in which autoantibodies can be tested (indirect immunofluorescence and antigen-specific tests) in the context of PBC and AIH are discussed, as well as the pitfalls in interpreting the test results. Summary: For appropriate interpretation of test results, an important prerequisite is that the doctor knows which test is used in the laboratory of choice and that the laboratory specialist is aware of what the doctor wants to test for. Good communication between clinician and laboratory specialist can, therefore, aid in the diagnosis of autoimmune liver diseases.
- 1 January 2022
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 7 (1) , 259-267
Open AccessThe Role of Autoantibodies in the Diagnosis of Autoimmune Liver Disease: Lessons Learned from Clinical Practice
Background: Primary biliary cholangitis (PBC), autoimmune hepatitis (AIH) and primary sclerosing cholangitis (PSC) are autoimmune liver diseases associated with distinct autoantibodies. Diagnosis is based upon clinical, serological, and histopathology findings. The role of autoantibodies in the diagnosis of these autoimmune liver diseases, with the focus on PBC and AIH, will be discussed. Content: When AIH or PBC is suspected, testing for multiple autoantibodies can be requested. In this mini-review, the different ways in which autoantibodies can be tested (indirect immunofluorescence and antigen-specific tests) in the context of PBC and AIH are discussed, as well as the pitfalls in interpreting the test results. Summary: For appropriate interpretation of test results, an important prerequisite is that the doctor knows which test is used in the laboratory of choice and that the laboratory specialist is aware of what the doctor wants to test for. Good communication between clinician and laboratory specialist can, therefore, aid in the diagnosis of autoimmune liver diseases.
- Open Access
- 16 January 2021
- Published by MDPI AG in Biomolecules
- Vol. 11 (1) , 116
Immune Monitoring upon Treatment with Biologics in Sjögren’s Syndrome: The What, Where, When, and How
Over the years, a wide variety of therapeutic antibodies has been successfully introduced in the auto-immunology clinic, and many more are on the way. Many of these treatments address either a pathogenic circulating molecule or a cell-bound molecule. Whereas addressing the former target results in neutralization of the soluble factor and binding to the latter target either inhibits cellular function or induces selective cell death. If this targeted molecule or cell is part of the immune system, this therapy evokes a state of immunodeficiency with infections as a possible consequence. Therefore, immune monitoring is needed to prevent such adverse side effects of immunotherapy. In this paper, different immunotherapies used in Sjögren’s syndrome, as well as different approaches to monitoring the immune system, are discussed.
- 16 January 2021
- Published by MDPI AG in Biomolecules
- Vol. 11 (1) , 116
Open AccessImmune Monitoring upon Treatment with Biologics in Sjögren’s Syndrome: The What, Where, When, and How
Over the years, a wide variety of therapeutic antibodies has been successfully introduced in the auto-immunology clinic, and many more are on the way. Many of these treatments address either a pathogenic circulating molecule or a cell-bound molecule. Whereas addressing the former target results in neutralization of the soluble factor and binding to the latter target either inhibits cellular function or induces selective cell death. If this targeted molecule or cell is part of the immune system, this therapy evokes a state of immunodeficiency with infections as a possible consequence. Therefore, immune monitoring is needed to prevent such adverse side effects of immunotherapy. In this paper, different immunotherapies used in Sjögren’s syndrome, as well as different approaches to monitoring the immune system, are discussed.
- Open Access
- 21 September 2018
- Published by Springer Nature in Autoimmunity Highlights
- Vol. 9 (1) , 8
Performance analysis of automated evaluation of antinuclear antibody indirect immunofluorescent tests in a routine setting
Indirect immunofluorescence (IIF) on the human epithelial cell-line HEp-2 (or derivatives) serves as the gold standard in antinuclear antibody (ANA) screening. IIF, and its evaluation, is a labor-intensive method, making ANA testing a major challenge for present clinical laboratories. Nowadays, several automated ANA pattern recognition systems are on the market. In the current study, the EUROPattern Suite is evaluated for its use in daily practice in a routine setting. A total of 1033 consecutive routine samples was used to screen for ANA. Results (positive/negative ANA screening, pattern identification and titer) were compared between software-generated results (EUROPattern) and visual interpretation (observer) of automatically acquired digital images. Considering the visual interpretation as reference, a relative sensitivity of 99.3% and a relative specificity of 88.9% were obtained for negative and positive discrimination by the software (EPa). A good agreement between visual and software-based interpretation was observed with respect to pattern recognition (mean kappa: for 7 patterns: 0.7). Interestingly, EPa software distinguished more patterns per positive sample than the observer (on average 1.5 and 1.2, respectively). Finally, a concordance of 99.3% was observed within the range of 1 titer step difference between EPa and observer. The ANA IIF results reported by the EPa software are in very good agreement with the results reported by the observer with respect to being negative/positive, pattern recognition and titer, making automated ANA IIF evaluation an objective and time-efficient tool for routine testing.
- 21 September 2018
- Published by Springer Nature in Autoimmunity Highlights
- Vol. 9 (1) , 8
Open AccessPerformance analysis of automated evaluation of antinuclear antibody indirect immunofluorescent tests in a routine setting
Indirect immunofluorescence (IIF) on the human epithelial cell-line HEp-2 (or derivatives) serves as the gold standard in antinuclear antibody (ANA) screening. IIF, and its evaluation, is a labor-intensive method, making ANA testing a major challenge for present clinical laboratories. Nowadays, several automated ANA pattern recognition systems are on the market. In the current study, the EUROPattern Suite is evaluated for its use in daily practice in a routine setting. A total of 1033 consecutive routine samples was used to screen for ANA. Results (positive/negative ANA screening, pattern identification and titer) were compared between software-generated results (EUROPattern) and visual interpretation (observer) of automatically acquired digital images. Considering the visual interpretation as reference, a relative sensitivity of 99.3% and a relative specificity of 88.9% were obtained for negative and positive discrimination by the software (EPa). A good agreement between visual and software-based interpretation was observed with respect to pattern recognition (mean kappa: for 7 patterns: 0.7). Interestingly, EPa software distinguished more patterns per positive sample than the observer (on average 1.5 and 1.2, respectively). Finally, a concordance of 99.3% was observed within the range of 1 titer step difference between EPa and observer. The ANA IIF results reported by the EPa software are in very good agreement with the results reported by the observer with respect to being negative/positive, pattern recognition and titer, making automated ANA IIF evaluation an objective and time-efficient tool for routine testing.
- 29 February 2016
- Published by Wiley in Vox Sanguinis
- Vol. 111 (1) , 33-42
Increased coagulation and fibrinolytic potential of solvent–detergent plasma: a comparative study between Omniplasma and fresh frozen plasma
Background and objectives: In this study, differences in levels of proteins involved in coagulation and fibrinolysis were compared between fresh frozen (quarantine plasma) and Omniplasma. Furthermore, thawing conditions and plasma stability after thawing were studied.Materials and Methods: 10 Omniplasma and 10 quarantine plasma units were used to study different procoagulation, anticoagulation and fibrinolytic parameters. Analysis took place at different time‐points during plasma storage at 2–6°C.Results: At baseline, significant reduced levels of factor V, free protein S, α2‐antiplasmin and tPA‐induced ROTEM lysis time were observed in Omniplasma as compared to quarantine plasma. Moreover, thrombin generation, IXa‐AT complex levels and factor XIa were significantly increased in Omniplasma. The majority of the parameters studied remained stable in Omniplasma 48 h after thawing, with the exception of factor VIII (decrease) and IXa‐AT (increase).Conclusion: Our results suggest an increased coagulation potential, presumingly as a result of contact activation during the production process and also, an increased fibrinolytic potential in Omniplasma.The stability of Omniplasma, based upon the different parameters studied, is comparable to Q‐plasma. A maximum post‐thawing time of 48 hfor Omniplasma can be suggested.
- 29 February 2016
- Published by Wiley in Vox Sanguinis
- Vol. 111 (1) , 33-42
Increased coagulation and fibrinolytic potential of solvent–detergent plasma: a comparative study between Omniplasma and fresh frozen plasma
Background and objectives: In this study, differences in levels of proteins involved in coagulation and fibrinolysis were compared between fresh frozen (quarantine plasma) and Omniplasma. Furthermore, thawing conditions and plasma stability after thawing were studied.Materials and Methods: 10 Omniplasma and 10 quarantine plasma units were used to study different procoagulation, anticoagulation and fibrinolytic parameters. Analysis took place at different time‐points during plasma storage at 2–6°C.Results: At baseline, significant reduced levels of factor V, free protein S, α2‐antiplasmin and tPA‐induced ROTEM lysis time were observed in Omniplasma as compared to quarantine plasma. Moreover, thrombin generation, IXa‐AT complex levels and factor XIa were significantly increased in Omniplasma. The majority of the parameters studied remained stable in Omniplasma 48 h after thawing, with the exception of factor VIII (decrease) and IXa‐AT (increase).Conclusion: Our results suggest an increased coagulation potential, presumingly as a result of contact activation during the production process and also, an increased fibrinolytic potential in Omniplasma.The stability of Omniplasma, based upon the different parameters studied, is comparable to Q‐plasma. A maximum post‐thawing time of 48 hfor Omniplasma can be suggested.