MTMagdalini Tozakidou

Magdalini Tozakidou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Magdalini Tozakidou has a total of 31 co-authors. Here are the top co-authors by number of shared publications:

  • Kay U. Petersen

    Department of Psychiatry and Psychotherapy, University Hospital Tübingen, Tübingen, Germany

    3 shared publications
  • Eilin Jopp-Van Well

    Department of Forensic Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

    2 shared publications
  • Jochen Herrmann

    Section of Pediatric Radiology, Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

    2 shared publications
  • Jochen Herrmann

    Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Section of Pediatric Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

    2 shared publications
  • Klaus Püschel

    Department of Forensic Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany

    2 shared publications
  • Sebastian Schindera

    Department of Radiology, Cantonal Hospital Aarau, Aarau, Switzerland

    2 shared publications

Latest Publications

  • Open Access

    Hepatic Artery Delineation on Ultrasound Volumes Comparing B-Flow and Color Doppler for Postoperative Monitoring of Pediatric Liver Transplants

    by Elena Dammann, Leonhard Steinmeister, Michael Groth, Uta Herden, Lutz Fischer, Florian Brinkert, Jan Beime, Magdalini Tozakidou, Peter Bannas, Jochen Herrmann

    (1) Background: Accurate hepatic artery (HA) depiction following pediatric liver transplantation (LT) is essential for graft surveillance but challenging on ultrasound (US). This study assesses if improved HA delineation can be achieved by recording two-dimensional US volumes in Color Doppler (CD) and B-flow technique. (2) Methods: Of 42 consecutive LT, 37 cases were included, and HA delineation was retrospectively rated using a four-point score (0 = HA not detectable, 3 = HA fully detectable, separable from portal vein) within 48 h post-LT (U1) and before discharge (U2). (3) Results: Adding B-flow compared with CD alone showed superior results at neohilar (U1: 2.2 ± 1.0 vs. 1.1 ± 0.8, p < 0.0001; U2: 2.5 ± 0.8 vs. 1.5 ± 0.9, p < 0.0001) and segmental levels (U1: 2.8 ± 0.6 vs. 0.6 ± 0.8, p < 0.0001; U2: 2.8 ± 0.6 vs. 0.7 ± 0.5, p < 0.0001). (4) Conclusions: Standardized US volume recordings combining B-flow and CD can effectively delineate the HA along its vascular course in pediatric LT. The technique should be further evaluated as a standard monitoring instrument to rule out vascular complications after LT.


  • Open Access

    CT of the medial clavicular epiphysis for forensic age estimation: hands up?

    by Magdalini Tozakidou, Rieke L. Meister, Lennart Well, Kay U. Petersen, Sebastian Schindera, Eilin Jopp-Van Well, Klaus Püschel, Jochen Herrmann

    Purpose: The aim of this study was to assess the impact of arm position in computed tomography (CT) of the clavicle performed for forensic age estimation on clavicular position, image noise, and radiation dose. Methods and materials: Forty-seven CT scans of the medial clavicular epiphysis performed for forensic age estimation were conducted with either hands and arms held upwards (CTHU, 28 persons) or positioned at the body (CTHD, 19 persons). Presets were identical for both positions (70 mAs/140 kVp; Brilliance iCT, Philips). Each CT scan was reconstructed with an iterative algorithm (i-Dose 4) and evaluated at the middle of the sternoclavicular joint. Clavicular angle was measured on a.p. topograms in relation to a horizontal line. Quantitative image noise was measured in air at the level of medial clavicular epiphysis. Effective dose and scan length were recorded. Results: Hands-up position compared with hands-down position resulted in a lower lateral body diameter (CTHU 41.1 ± 3.6 cm vs. CTHD 44.6 ± 3.1 cm; P = 0.03), a reduced quantitative image noise (CTHU: 39.5 ± 9.2; CTHD: 46.2 ± 8.3; P = 0.02), and lower CTDIvol (5.1 ± 1.4 mGy vs. 6.7 ± 1.8 mGy; P = 0.001). Scan length was longer in patients examined with hands up (HU: 8.5 ± 3.4 cm; HD: 6.2 ± 2.1 cm; P = 0.006). Mean effective dose for CTHU was 0.79 ± 0.32 mSv compared with 0.95 ± 0.38 mSv in CTHD (P = 0.12). Clavicular angle was 17° ± 6° in patients with hands down and 32° ± 7° in patients with hands up (P < 0.001). Conclusion: By elevated arm positioning, the image quality of clavicular CT scans can be improved while maintaining radiation dose compared with hands down. Clavicular position differs according to the hand position. Thus, positioning patients with elevated hands is advisable for forensic clavicular CT examinations, but multiplanar CT reconstructions should be adjusted to clavicular position and scan length should be reduced to a minimum.


  • Comparison of different iterative CT reconstruction techniques and filtered back projection for assessment of the medial clavicular epiphysis in forensic age estimation

    by Magdalini Tozakidou, Ilze Apine, Kay U. Petersen, Julius Matthias Weinrich, Sebastian Schindera, Eilin Jopp-Van Well, Klaus Püschel, Jochen Herrmann

    To assess the impact of iterative reconstruction and filtered back projection (FBP) on image quality in computed tomography (CT)-based forensic age estimation of the medial clavicular epiphysis.


  • Open Access

    Persistence of post‐operative color Doppler abnormalities is linked to reduced graft survival in pediatric patients after liver transplantation

    by Jochen Herrmann, Magdalini Tozakidou, Jasmin Busch, Uta Herden, Lutz Fischer, Michael Groth, Kay U. Petersen, Knut Helmke

    Color Doppler US is a readily available imaging modality for the evaluation of liver transplants. The aim of our study was to evaluate the temporal course of color Doppler US findings in children after LTX and to investigate the effect of resolving and persisting abnormalities during follow‐up on long‐term outcome. All children who underwent LTX during January 2000 until December 2003 (155 LTX in 137 patients, 75 male and 62 female; mean age at LTX 4.1 ± 4.8 years; range, 0.1‐16.3 years) were retrospectively evaluated. Following a predefined ultrasound protocol with prospective documentation, intraoperative, post‐operative, and follow‐up examinations were evaluated for color Doppler abnormalities. The time of occurrence and temporal course of the findings were recorded. Graft survival rates and graft survival times were compared. Abnormal color Doppler US examinations were noted in 98 of 155 grafts during the entire observational period (63.2%). In 57 of 98 grafts (58.2%), abnormalities were limited to the perioperative period (30 days after LTX; 37/98 LTX, 37.8%) showed reduced survival compared with regular courses (graft survival rate 62.2% vs 80.7%, P = .047), indicating underlying organ‐specific alterations. Standardized longitudinal evaluation during the perioperative and the follow‐up period can enhance the prognostic capabilities of color Doppler US in children following LTX.


  • Open Access

    Systematic Radiation Dose Reduction in Cervical Spine CT of Human Cadaveric Specimens: How Low Can We Go?

    by M. Tozakidou, C. Reisinger, D. Harder, J. Lieb, Z. Szucs-Farkas, M. Müller-Gerbl, U. Studler, S. Schindera, A. Hirschmann

    BACKGROUND AND PURPOSE: While the use of cervical spine CT in trauma settings has increased, the balance between image quality and dose reduction remains a concern. The purpose of our study was to compare the image quality of CT of the cervical spine of cadaveric specimens at different radiation dose levels. MATERIALS AND METHODS: The cervical spine of 4 human cadavers (mean body mass index; 30.5 ± 5.2 kg/m2; range, 24–36 kg/m2) was examined using different reference tube current–time products (45, 75, 105, 135, 150, 165, 195, 275, 355 mAs) and a tube voltage of 120 kV(peak). Data were reconstructed with filtered back-projection and iterative reconstruction. Qualitative image noise and morphologic characteristics of bony structures were quantified on a Likert scale. Quantitative image noise was measured. Statistics included analysis of variance and the Tukey test. RESULTS: Compared with filtered back-projection, iterative reconstruction provided significantly lower qualitative (mean noise score: iterative reconstruction = 2.10/filtered back-projection = 2.18; P = .003) and quantitative (mean SD of Hounsfield units in air: iterative reconstruction = 30.2/filtered back-projection = 51.8; P < .001) image noise. Image noise increased as the radiation dose decreased. Qualitative image noise at levels C1–4 was rated as either “no noise” or as “acceptable noise.” Any shoulder position was at level C5 and caused more artifacts at lower levels. When we analyzed all spinal levels, scores for morphologic characteristics revealed no significant differences between 105 and 355 mAs (P = .555), but they were worse in scans at 75 mAs (P = .025). CONCLUSIONS: Clinically acceptable image quality of cervical spine CTs for evaluation of bony structures of cadaveric specimens with different body habitus can be achieved with a reference mAs of 105 at 120 kVp with iterative reconstruction. Pull-down of shoulders during acquisition could improve image quality but may not be feasible in trauma patients with unknown injuries.