Andrej Kral
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Andrej Kral has a total of 244 co-authors. Here are the top co-authors by number of shared publications:
- Peter Baumhoff
Department of Experimental Otology, Hannover Medical School
22 shared publications - Peter Hubka
Department of Experimental Otology Hannover Medical School Hannover Germany
18 shared publications Jochen Tillein
MED-EL Medical Electronics GmbH
15 shared publications- Rüdiger Land
Institute for Audioneurotechnology, Department of Experimental Otology, Hannover Medical School
11 shared publications - Thomas Lenarz
Department of Otolaryngology, Hannover Medical School, Hannover, Germany
11 shared publications Thomas Lenarz
Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
10 shared publications
Latest Publications
- 6 November 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- p. 1-22
The Listening and Spoken Language Development in Deaf and Hard of Hearing Children in Early Intervention
Purpose: This longitudinal study examined the development of listening and spoken language skills in 322 deaf and hard of hearing children who participated in a multidisciplinary early intervention program. Method: Listening skill acquisition was assessed using the Functional Listening Index–Paediatric (3,911 assessments) in children from 0 to 6 years of age accessing the program between 2011 and 2022 and was analyzed against standardized language scores (1,015 assessments) measured using the Preschool Language Scale–Fourth/Fifth Edition and the Clinical Evaluation of Language Fundamentals Preschool–Third/Fourth Edition. Listening scores were compared with previously reported normative data for age-matched typically hearing controls. Results: Results indicated that listening scores significantly correlated with language scores with similar development trajectories. When listening and language scores were normalized using z scores to enable accurate comparison, listening scores proved more sensitive to the effects of hearing loss. Time in the early intervention program, diagnosed additional needs, language background of the family, and age at commencement of intervention were found to be significant factors influencing outcomes. Commencement of early intervention before 5 months of age resulted in the highest scores when compared with 20 months after intervention. There was no interaction found for mean bilateral hearing thresholds on listening or language outcomes, indicating that the range of audiological devices available is providing appropriate levels of access to sound for children to achieve similar results regardless of type of device required. Conclusion: These results suggest that listening measures can provide complementary information on skill development that standard language scores do not incorporate.
- 6 November 2026
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- p. 1-22
The Listening and Spoken Language Development in Deaf and Hard of Hearing Children in Early Intervention
Purpose: This longitudinal study examined the development of listening and spoken language skills in 322 deaf and hard of hearing children who participated in a multidisciplinary early intervention program. Method: Listening skill acquisition was assessed using the Functional Listening Index–Paediatric (3,911 assessments) in children from 0 to 6 years of age accessing the program between 2011 and 2022 and was analyzed against standardized language scores (1,015 assessments) measured using the Preschool Language Scale–Fourth/Fifth Edition and the Clinical Evaluation of Language Fundamentals Preschool–Third/Fourth Edition. Listening scores were compared with previously reported normative data for age-matched typically hearing controls. Results: Results indicated that listening scores significantly correlated with language scores with similar development trajectories. When listening and language scores were normalized using z scores to enable accurate comparison, listening scores proved more sensitive to the effects of hearing loss. Time in the early intervention program, diagnosed additional needs, language background of the family, and age at commencement of intervention were found to be significant factors influencing outcomes. Commencement of early intervention before 5 months of age resulted in the highest scores when compared with 20 months after intervention. There was no interaction found for mean bilateral hearing thresholds on listening or language outcomes, indicating that the range of audiological devices available is providing appropriate levels of access to sound for children to achieve similar results regardless of type of device required. Conclusion: These results suggest that listening measures can provide complementary information on skill development that standard language scores do not incorporate.
- Open Access
- 1 July 2026
- Published by Elsevier in Zeitschrift für Medizinische Physik
Determination of long-range resistance from high resolution impedance spectroscopy in human cadaveric heads
- 1 July 2026
- Published by Elsevier in Zeitschrift für Medizinische Physik
Open AccessDetermination of long-range resistance from high resolution impedance spectroscopy in human cadaveric heads
- Open Access
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
The Failure Index as Marker of the Neural Health Profile in MED-EL CI Users: A Retrospective Analysis
Cochlear implants (CIs) enable hearing via direct electrical stimulation of the spiral ganglion neurons (SGN). Outcomes with a CI depend, in part, on the number and excitability of the SGNs. In an animal model, we introduced the Failure Index (FI) as an electrically-evoked compound action potential (eCAP)-derived marker of cochlear health. The FI informs about the presence, site, and size of SGN lesions. Here, we translated the FI to clinical recordings from human MED-EL CI users. In this retrospective study, we included patient data recorded between 2016 and 2024 from 199 ears with postlingual hearing loss and 79 ears with prelingual hearing loss. The averaged FI values over all contacts of the array were stable within the analysis period (3 rd month to 1 st year postoperatively). The FI increased with age and was elevated in etiologies associated with higher SGN loss. Using 3D reconstruction from cone-beam computed tomography scans, we confirmed that the FI was independent of electrode-to-modiolus distance (0.1–2.5 mm). The FI showed individual patterns along the array, with maxima usually found at basal contacts, corresponding to reduced neural health at high-frequency cochlear regions. In a selected group of postlingual-deaf ears, we found higher correlation coefficients between speech-perception scores and the FI compared to other eCAP-derived markers (i.e., threshold, slope, and amplitude). These results were in line with the hypothesis that the FI may serve as a clinical tool to identify implanted ears with reduced neural health and to identify contacts stimulating areas of reduced SGN survival and integrity.
- 1 January 2026
- Published by SAGE Publications in Trends in Hearing
- Vol. 30
Open AccessThe Failure Index as Marker of the Neural Health Profile in MED-EL CI Users: A Retrospective Analysis
Cochlear implants (CIs) enable hearing via direct electrical stimulation of the spiral ganglion neurons (SGN). Outcomes with a CI depend, in part, on the number and excitability of the SGNs. In an animal model, we introduced the Failure Index (FI) as an electrically-evoked compound action potential (eCAP)-derived marker of cochlear health. The FI informs about the presence, site, and size of SGN lesions. Here, we translated the FI to clinical recordings from human MED-EL CI users. In this retrospective study, we included patient data recorded between 2016 and 2024 from 199 ears with postlingual hearing loss and 79 ears with prelingual hearing loss. The averaged FI values over all contacts of the array were stable within the analysis period (3 rd month to 1 st year postoperatively). The FI increased with age and was elevated in etiologies associated with higher SGN loss. Using 3D reconstruction from cone-beam computed tomography scans, we confirmed that the FI was independent of electrode-to-modiolus distance (0.1–2.5 mm). The FI showed individual patterns along the array, with maxima usually found at basal contacts, corresponding to reduced neural health at high-frequency cochlear regions. In a selected group of postlingual-deaf ears, we found higher correlation coefficients between speech-perception scores and the FI compared to other eCAP-derived markers (i.e., threshold, slope, and amplitude). These results were in line with the hypothesis that the FI may serve as a clinical tool to identify implanted ears with reduced neural health and to identify contacts stimulating areas of reduced SGN survival and integrity.
- Open Access
The Failure Index as marker of cochlear health in MED-EL CI users: Anatomy, demographics, and speech correlations
Cochlear implants (CIs) enable hearing with the deafened ear, via direct, electrical stimulation of the spiral ganglion neurons (SGN). Thus, the outcome depends on the number and excitability of the SGNs. We recently established the electrically-evoked compound action potential (eCAP)-derived Failure Index (FI) as cochlear-health marker in the animal model. The FI informs about the presence, site, and size of a SGN lesion. Here, we translated the FI to clinical recordings of MED-EL CI users. For the retrospective study, we selected patient data from the database of the German Hearing Center Hannover recorded 2017 to 2024. We included 199 post-lingually and 79 pre-lingually deafened ears. Averaged FIs over all contacts of a CI were stable within the analysis period (3 rd month to 1 st year postoperatively). The FI increased with age and was elevated for etiologies associated with higher SGN loss. Utilizing 3D information from cone beam-computed tomography scans, we confirmed that the FI was independent of distance (0.1-2.5 mm) to the modiolus. The FI showed individual patterns along the array with maxima usually at basal contacts, corresponding to elevated SGN loss at high frequencies. In a selected group of post-lingually deaf ears, we confirmed the correlation of the FI with speech perception in quiet and in noise (n=28, r 2 =0.12-0.55). Thus, we propose the FI as promising clinical tool to identify CI-implanted ears with reduced neural health and contacts close to areas of SGN loss. Thereby, it can serve to guide speech-processor fitting to optimize CI outcomes.
Open AccessThe Failure Index as marker of cochlear health in MED-EL CI users: Anatomy, demographics, and speech correlations
Cochlear implants (CIs) enable hearing with the deafened ear, via direct, electrical stimulation of the spiral ganglion neurons (SGN). Thus, the outcome depends on the number and excitability of the SGNs. We recently established the electrically-evoked compound action potential (eCAP)-derived Failure Index (FI) as cochlear-health marker in the animal model. The FI informs about the presence, site, and size of a SGN lesion. Here, we translated the FI to clinical recordings of MED-EL CI users. For the retrospective study, we selected patient data from the database of the German Hearing Center Hannover recorded 2017 to 2024. We included 199 post-lingually and 79 pre-lingually deafened ears. Averaged FIs over all contacts of a CI were stable within the analysis period (3 rd month to 1 st year postoperatively). The FI increased with age and was elevated for etiologies associated with higher SGN loss. Utilizing 3D information from cone beam-computed tomography scans, we confirmed that the FI was independent of distance (0.1-2.5 mm) to the modiolus. The FI showed individual patterns along the array with maxima usually at basal contacts, corresponding to elevated SGN loss at high frequencies. In a selected group of post-lingually deaf ears, we confirmed the correlation of the FI with speech perception in quiet and in noise (n=28, r 2 =0.12-0.55). Thus, we propose the FI as promising clinical tool to identify CI-implanted ears with reduced neural health and contacts close to areas of SGN loss. Thereby, it can serve to guide speech-processor fitting to optimize CI outcomes.
- Open Access
- 26 September 2025
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 45 (47)
Origins of the Auditory Brainstem Response in Mice Using Source Localization of Topographic Multichannel EEG
The auditory brainstem response (ABR) is a critical tool for assessing auditory brainstem function in biomedical mouse models. Remarkably, despite its importance, the origins of ABR waves specific to mice remain poorly identified. Here, we used EEG source reconstruction to reevaluate the mouse-specific ABR origins. We recorded the topography of ABRs using high-density EEG from the skull of adult mice of either sex combined with parallel multielectrode recordings in the auditory cortex. Individual ABR waves showed a series of distinct spatial topographies across the skull. Wave I’ was strongly lateralized, supporting its auditory nerve origin. Waves II/III were also lateralized but had a more frontal distribution, supporting an origin in the cochlear nucleus and olivary complex. A distinct shift in wave IV topography showed focused activity directly above the inferior colliculus (IC). Source localization with beamforming supported the origin of wave IV and V in the IC. In addition, the slow IC wave, P 0 , temporally overlapped with responses in the auditory cortex. We identify ABR wave IV as a marker of IC activity, separating earlier brainstem contributions (cochlear nucleus, olivary complex) from later thalamic and cortical components. This finding improves the anatomical specificity of the mouse ABR as a noninvasive marker in biomedical mouse models.
- 26 September 2025
- Published by Society for Neuroscience in Journal of Neuroscience
- Vol. 45 (47)
Open AccessOrigins of the Auditory Brainstem Response in Mice Using Source Localization of Topographic Multichannel EEG
The auditory brainstem response (ABR) is a critical tool for assessing auditory brainstem function in biomedical mouse models. Remarkably, despite its importance, the origins of ABR waves specific to mice remain poorly identified. Here, we used EEG source reconstruction to reevaluate the mouse-specific ABR origins. We recorded the topography of ABRs using high-density EEG from the skull of adult mice of either sex combined with parallel multielectrode recordings in the auditory cortex. Individual ABR waves showed a series of distinct spatial topographies across the skull. Wave I’ was strongly lateralized, supporting its auditory nerve origin. Waves II/III were also lateralized but had a more frontal distribution, supporting an origin in the cochlear nucleus and olivary complex. A distinct shift in wave IV topography showed focused activity directly above the inferior colliculus (IC). Source localization with beamforming supported the origin of wave IV and V in the IC. In addition, the slow IC wave, P 0 , temporally overlapped with responses in the auditory cortex. We identify ABR wave IV as a marker of IC activity, separating earlier brainstem contributions (cochlear nucleus, olivary complex) from later thalamic and cortical components. This finding improves the anatomical specificity of the mouse ABR as a noninvasive marker in biomedical mouse models.
- Open Access
- 13 August 2025
- Published by Elsevier in Hearing Research
- Vol. 467, 109401
Sensorimotor contingencies in congenital hearing loss: The critical first nine months
- 13 August 2025
- Published by Elsevier in Hearing Research
- Vol. 467, 109401
Open AccessSensorimotor contingencies in congenital hearing loss: The critical first nine months
- 18 April 2025
- Published by Elsevier in Hearing Research
- Vol. 461, 109281
Editorial, Hear Res 2024
- Top Cited PapersOpen Access
- 17 March 2025
- Published by SAGE Publications in Trends in Hearing
- Vol. 29
Limitations on Temporal Processing by Cochlear Implant Users: A Compilation of Viewpoints
Cochlear implant (CI) users are usually poor at using timing information to detect changes in either pitch or sound location. This deficit occurs even for listeners with good speech perception and even when the speech processor is bypassed to present simple, idealized stimuli to one or more electrodes. The present article presents seven expert opinion pieces on the likely neural bases for these limitations, the extent to which they are modifiable by sensory experience and training, and the most promising ways to overcome them in future. The article combines insights from physiology and psychophysics in cochlear-implanted humans and animals, highlights areas of agreement and controversy, and proposes new experiments that could resolve areas of disagreement.
- 17 March 2025
- Published by SAGE Publications in Trends in Hearing
- Vol. 29
Top Cited PapersOpen AccessLimitations on Temporal Processing by Cochlear Implant Users: A Compilation of Viewpoints
Cochlear implant (CI) users are usually poor at using timing information to detect changes in either pitch or sound location. This deficit occurs even for listeners with good speech perception and even when the speech processor is bypassed to present simple, idealized stimuli to one or more electrodes. The present article presents seven expert opinion pieces on the likely neural bases for these limitations, the extent to which they are modifiable by sensory experience and training, and the most promising ways to overcome them in future. The article combines insights from physiology and psychophysics in cochlear-implanted humans and animals, highlights areas of agreement and controversy, and proposes new experiments that could resolve areas of disagreement.
- Open Access
- 20 February 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (4) , 476-484
Surgical Transcanal Procedure for Injection of Cells and Substances into the Human Cochlear Modiolus
Introduction: Cochlear implants (CIs) enhance hearing by stimulating spiral ganglion neurons (SGNs) but are less effective in individuals with compromised SGN functionality. Advances in regenerative medicine suggest that local delivery of medical drugs or cell therapy could regenerate the auditory nerve. This study evaluates a minimally invasive technique for precise delivery of cell-sized beads, simulating cell therapy, into the cochlear modiolus of human temporal bones. Methods: Ten fresh-frozen human temporal bone specimens were used. Five bones served to establish the injection trajectory using a tungsten rod probe, and the remaining five for injecting microbeads into the modiolus. The surgical procedure involved accessing the middle ear via the external ear canal, performing a cochleostomy at the first cochlear turn, and drilling into the modiolus. Beads were injected into the modiolus using a Hamilton syringe connected to an injection pump, followed by micro-computed tomography imaging and histological assessment. Results: Accurate placement of the tungsten rod probe within the modiolus was achieved in four out of five bones. Microbead injections indicated 89 to 97% retention within the modiolus, with minimal leakage. The technique showed consistent trajectory with low variability. Conclusion: The study demonstrates the feasibility of a minimally invasive, precise injection method for delivering and retaining cell-sized beads into the cochlear modiolus. This technique enables future local delivery of medical drugs or cell therapy drugs aimed at hearing restoration, benefiting both current CI users and CI candidates. Further research is necessary to evaluate precision, reproducibility, and long-term outcomes of the procedure.
- 20 February 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (4) , 476-484
Open AccessSurgical Transcanal Procedure for Injection of Cells and Substances into the Human Cochlear Modiolus
Introduction: Cochlear implants (CIs) enhance hearing by stimulating spiral ganglion neurons (SGNs) but are less effective in individuals with compromised SGN functionality. Advances in regenerative medicine suggest that local delivery of medical drugs or cell therapy could regenerate the auditory nerve. This study evaluates a minimally invasive technique for precise delivery of cell-sized beads, simulating cell therapy, into the cochlear modiolus of human temporal bones. Methods: Ten fresh-frozen human temporal bone specimens were used. Five bones served to establish the injection trajectory using a tungsten rod probe, and the remaining five for injecting microbeads into the modiolus. The surgical procedure involved accessing the middle ear via the external ear canal, performing a cochleostomy at the first cochlear turn, and drilling into the modiolus. Beads were injected into the modiolus using a Hamilton syringe connected to an injection pump, followed by micro-computed tomography imaging and histological assessment. Results: Accurate placement of the tungsten rod probe within the modiolus was achieved in four out of five bones. Microbead injections indicated 89 to 97% retention within the modiolus, with minimal leakage. The technique showed consistent trajectory with low variability. Conclusion: The study demonstrates the feasibility of a minimally invasive, precise injection method for delivering and retaining cell-sized beads into the cochlear modiolus. This technique enables future local delivery of medical drugs or cell therapy drugs aimed at hearing restoration, benefiting both current CI users and CI candidates. Further research is necessary to evaluate precision, reproducibility, and long-term outcomes of the procedure.
- Open Access
- 14 December 2024
- Published by Elsevier in Hearing Research
- Vol. 456, 109167
Auditory working memory in noise in cochlear implant users: Insights from behavioural and neuronal measures
- 14 December 2024
- Published by Elsevier in Hearing Research
- Vol. 456, 109167
Open AccessAuditory working memory in noise in cochlear implant users: Insights from behavioural and neuronal measures