Krishnapillai Girish Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Krishnapillai Girish Kumar has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
Sonia Sam
Cochin Univ Sci & Technol, Dept Appl Chem, Kochi 22, India
10 shared publications- Unni Sivasankaran
Department of Applied Chemistry, Cochin University of Science and Technology, Kochi-22, Kerala, India
10 shared publications Manna Rachel Mathew
Department of Applied Chemistry, Cochin University of Science and Technology, Kochi, India
9 shared publicationsSanu K. Anand
Department of Applied Chemistry, Cochin University of Science and Technology, Kochi, India
8 shared publicationsDivya Thomas
Department of Applied Chemistry, Cochin University of Science and Technology, Kochi, India
7 shared publicationsShalini Menon
Department of Applied Chemistry, Cochin University of Science and Technology, Kochi 682022, India
7 shared publications
Latest Publications
- 1 April 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (4) , 047520
Poly(tannic acid)- Electrochemically Reduced Graphene Oxide Nanocomposite Based Voltammetric Sensor for the Simultaneous Determination of L-dopa and Tyramine
A highly efficient voltammetric sensor for L-dopa and tyramine (TYM) has been developed based on a nanocomposite of poly(tannic acid) (p(TA)) and electrochemically reduced graphene oxide (rGO). The nanocomposite-modified electrode- p(TA)-rGO/GCE has been prepared using an electropolymerization procedure and is characterized by several analytical techniques. At the modified electrode, well-resolved peaks with enhanced peak current for L-dopa and TYM were obtained at lower overpotentials. Under optimized analytical conditions, the sensor has been used for the simultaneous determination of L-dopa in two dynamic ranges from 7.00 × 10−6 M–2.00 × 10−6 M and 1.00 × 10−6 M–1.00 × 10−7 M and TYM in the ranges from 8.00 × 10−6 M–2.00 × 10−6 M and 1.00 × 10−6 M–6.00 × 10−8 M. The proposed sensor offered high sensitivity with a limit of detection of 1.26 × 10−8 M for L-dopa and 4.73 × 10−9 M for TYM. The mechanistic aspects of the electro oxidation of the analytes were examined. The validity of the sensor has been assessed by the determination of L-dopa and TYM in artificial physiological samples and satisfactory results were obtained.
- 1 April 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (4) , 047520
Poly(tannic acid)- Electrochemically Reduced Graphene Oxide Nanocomposite Based Voltammetric Sensor for the Simultaneous Determination of L-dopa and Tyramine
A highly efficient voltammetric sensor for L-dopa and tyramine (TYM) has been developed based on a nanocomposite of poly(tannic acid) (p(TA)) and electrochemically reduced graphene oxide (rGO). The nanocomposite-modified electrode- p(TA)-rGO/GCE has been prepared using an electropolymerization procedure and is characterized by several analytical techniques. At the modified electrode, well-resolved peaks with enhanced peak current for L-dopa and TYM were obtained at lower overpotentials. Under optimized analytical conditions, the sensor has been used for the simultaneous determination of L-dopa in two dynamic ranges from 7.00 × 10−6 M–2.00 × 10−6 M and 1.00 × 10−6 M–1.00 × 10−7 M and TYM in the ranges from 8.00 × 10−6 M–2.00 × 10−6 M and 1.00 × 10−6 M–6.00 × 10−8 M. The proposed sensor offered high sensitivity with a limit of detection of 1.26 × 10−8 M for L-dopa and 4.73 × 10−9 M for TYM. The mechanistic aspects of the electro oxidation of the analytes were examined. The validity of the sensor has been assessed by the determination of L-dopa and TYM in artificial physiological samples and satisfactory results were obtained.
- 1 November 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (11) , 117516
PolyCitrulline Modified Glassy Carbon Electrode as a Voltammetric Sensor for the Simultaneous Determination of Metabolic Syndrome Biomarkers-Uric Acid and Tyramine
This article describes the development of a simple and sensitive voltammetric sensor for the simultaneous determination of Uric acid (UA) and Tyramine (TYM), which act as metabolic syndrome (Mts) biomarkers. The electropolymer of the naturally occurring amino acid citrulline (Cit) has been employed as the electrode modifier in this sensor. Glassy carbon electrode modified with poly citrulline has been characterized with the aid of techniques such as scanning electron microscopy (SEM) and SEM-energy dispersive X-ray analysis, surface area calculations and electrochemical impedance spectroscopy. Studies were carried out to optimize parameters like the cycles of polymerisation, supporting electrolyte and its pH. The sensor which offers fast determination of the analytes using square wave voltammetry possesses a limit of detection 1.32 × 10−8 M and 4.20 × 10−8 M for UA and TYM, respectively. The applicability of the sensor in body fluids has been proved through spike recovery analysis in artificial blood serum and urine samples. Interference on the voltammetric signals created by some dominant coexisting species of the analytes was found to be tolerable.
- 1 November 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (11) , 117516
PolyCitrulline Modified Glassy Carbon Electrode as a Voltammetric Sensor for the Simultaneous Determination of Metabolic Syndrome Biomarkers-Uric Acid and Tyramine
This article describes the development of a simple and sensitive voltammetric sensor for the simultaneous determination of Uric acid (UA) and Tyramine (TYM), which act as metabolic syndrome (Mts) biomarkers. The electropolymer of the naturally occurring amino acid citrulline (Cit) has been employed as the electrode modifier in this sensor. Glassy carbon electrode modified with poly citrulline has been characterized with the aid of techniques such as scanning electron microscopy (SEM) and SEM-energy dispersive X-ray analysis, surface area calculations and electrochemical impedance spectroscopy. Studies were carried out to optimize parameters like the cycles of polymerisation, supporting electrolyte and its pH. The sensor which offers fast determination of the analytes using square wave voltammetry possesses a limit of detection 1.32 × 10−8 M and 4.20 × 10−8 M for UA and TYM, respectively. The applicability of the sensor in body fluids has been proved through spike recovery analysis in artificial blood serum and urine samples. Interference on the voltammetric signals created by some dominant coexisting species of the analytes was found to be tolerable.
- 18 August 2024
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 55 (2) , 449-465
Copper-decorated poly(3-amino-5-mercapto-1,2,4-triazole)-modified glassy carbon electrode-based electrochemical sensor for the simultaneous determination of L-Dopa and Vanillylmandelic acid—an expeditious tool for monitoring neuroblastoma and hepatocellular carcinoma
- 18 August 2024
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 55 (2) , 449-465
Copper-decorated poly(3-amino-5-mercapto-1,2,4-triazole)-modified glassy carbon electrode-based electrochemical sensor for the simultaneous determination of L-Dopa and Vanillylmandelic acid—an expeditious tool for monitoring neuroblastoma and hepatocellular carcinoma
- 29 July 2024
- Published by Springer Nature in Journal of Analysis and Testing
- Vol. 9 (2) , 222-231
Development of a Voltammetric Sensor for the Selective Determination of Tumour Biomarker-Vanillylmandelic Acid
- 29 July 2024
- Published by Springer Nature in Journal of Analysis and Testing
- Vol. 9 (2) , 222-231
Development of a Voltammetric Sensor for the Selective Determination of Tumour Biomarker-Vanillylmandelic Acid
- 12 April 2024
- Published by Springer Nature in Ionics
- Vol. 30 (6) , 3521-3539
polycalconcarboxylic acid/electrochemically reduced graphene oxide-modified glassy carbon electrode-based voltammetric sensor for the simultaneous determination of dopamine and tyrosine
- 12 April 2024
- Published by Springer Nature in Ionics
- Vol. 30 (6) , 3521-3539
polycalconcarboxylic acid/electrochemically reduced graphene oxide-modified glassy carbon electrode-based voltammetric sensor for the simultaneous determination of dopamine and tyrosine
- 1 January 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (1) , 017509
A Poly(L-Arginine)-Based Electrochemical Sensor for Simultaneous Determination of Uric Acid, Tryptophan, and Hypoxanthine
This study presents the development of an efficient and cost-effective voltammetric sensor for the individual and simultaneous determination of uric acid (UA), tryptophan (Try) and hypoxanthine (HX), the three important biomarkers in the human body. The sensor consists of glassy carbon electrode (GCE) modified with the conducting layer of poly(L-Arginine) (p-Arg) prepared by the electropolymerisation of L-Arginine using cyclic voltammetry. p-Arg modified GCE (p-Arg/GCE) provided well-resolved and improved electrooxidation responses for UA, Try, and HX due to the greater electrocatalytic activity and fast electron transfer ability of the polymer layer. The fabricated sensor was characterised using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDX), Atomic Force Microscopy (AFM), Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FTIR), Electrochemical Impedance Spectroscopy (EIS) and electroactive surface area calculations. Under optimal analytical conditions, determination of the three analytes was possible over wide linear ranges with the limit of detection of 1.97 × 10−8 M, 4.43 × 10−8 M, and 8.44 × 10−9 M, respectively for UA, Try, and HX. Practical utility of the sensor was successfully verified in synthetic urine and blood serum samples and determination of Try and HX was carried out in dietary supplements and commercially available samples of tea and coffee, respectively.
- 1 January 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (1) , 017509
A Poly(L-Arginine)-Based Electrochemical Sensor for Simultaneous Determination of Uric Acid, Tryptophan, and Hypoxanthine
This study presents the development of an efficient and cost-effective voltammetric sensor for the individual and simultaneous determination of uric acid (UA), tryptophan (Try) and hypoxanthine (HX), the three important biomarkers in the human body. The sensor consists of glassy carbon electrode (GCE) modified with the conducting layer of poly(L-Arginine) (p-Arg) prepared by the electropolymerisation of L-Arginine using cyclic voltammetry. p-Arg modified GCE (p-Arg/GCE) provided well-resolved and improved electrooxidation responses for UA, Try, and HX due to the greater electrocatalytic activity and fast electron transfer ability of the polymer layer. The fabricated sensor was characterised using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDX), Atomic Force Microscopy (AFM), Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy (ATR-FTIR), Electrochemical Impedance Spectroscopy (EIS) and electroactive surface area calculations. Under optimal analytical conditions, determination of the three analytes was possible over wide linear ranges with the limit of detection of 1.97 × 10−8 M, 4.43 × 10−8 M, and 8.44 × 10−9 M, respectively for UA, Try, and HX. Practical utility of the sensor was successfully verified in synthetic urine and blood serum samples and determination of Try and HX was carried out in dietary supplements and commercially available samples of tea and coffee, respectively.
- 1 December 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (12) , 127504
Simultaneous Determination of Serotonin and Tryptamine Using Polyglutamic Acid-Silver Nanoparticles Composite Film Modified Glassy Carbon Electrode
Serotonin (ST), chemically 5-hydroxy tryptamine, is a neurotransmitter which mediates a series of central and peripheral functions in the human body and has a crucial role in gastrointestinal and psychiatric disorders. Tryptamine (Tryp) is also a neurotransmitter, mainly found in protein-rich foods, beverages and other fermented foods. The accumulation of higher concentrations of Tryp is harmful to human health. So, it is important to determine both ST and Tryp in our body. A polyglutamic acid (pGlu)-Silver Nanoparticles (AgNPs) composite film modified Glassy Carbon Electrode (pGlu-AgNPs/GCE) has been developed for the simultaneous determination of ST and Tryp. The incorporation of AgNPs with pGlu makes the sensor more efficient and reliable for the voltammetric sensing of ST and Tryp. Experimental parameters were optimised and, the sensor showed a linear concentration range for the determination of ST and Tryp from 1.00 × 10–5 M to 7.00 × 10–7 M and 1.00 × 10–5 M to 9.00 × 10–7 M, respectively. The electrooxidation of ST at pGlu-AgNPs/GCE was found to be diffusion controlled, whereas adsorption controlled electrooxidation was found for Tryp. The applicability of the sensor in determining ST and Tryp has been checked in artificial physiological fluids.
- 1 December 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (12) , 127504
Simultaneous Determination of Serotonin and Tryptamine Using Polyglutamic Acid-Silver Nanoparticles Composite Film Modified Glassy Carbon Electrode
Serotonin (ST), chemically 5-hydroxy tryptamine, is a neurotransmitter which mediates a series of central and peripheral functions in the human body and has a crucial role in gastrointestinal and psychiatric disorders. Tryptamine (Tryp) is also a neurotransmitter, mainly found in protein-rich foods, beverages and other fermented foods. The accumulation of higher concentrations of Tryp is harmful to human health. So, it is important to determine both ST and Tryp in our body. A polyglutamic acid (pGlu)-Silver Nanoparticles (AgNPs) composite film modified Glassy Carbon Electrode (pGlu-AgNPs/GCE) has been developed for the simultaneous determination of ST and Tryp. The incorporation of AgNPs with pGlu makes the sensor more efficient and reliable for the voltammetric sensing of ST and Tryp. Experimental parameters were optimised and, the sensor showed a linear concentration range for the determination of ST and Tryp from 1.00 × 10–5 M to 7.00 × 10–7 M and 1.00 × 10–5 M to 9.00 × 10–7 M, respectively. The electrooxidation of ST at pGlu-AgNPs/GCE was found to be diffusion controlled, whereas adsorption controlled electrooxidation was found for Tryp. The applicability of the sensor in determining ST and Tryp has been checked in artificial physiological fluids.
- 19 October 2023
- Published by Wiley in ChemistrySelect
- Vol. 8 (39)
Ascorbic Acid‐Capped Copper Nanoclusters: A Turn‐On Fluorescence Sensor for Biliverdin
A simple and facile turn‐on fluorescence sensor has been developed for the effective determination of an important bile pigment‐ Biliverdin (BVD), using ascorbic acid capped copper nanoclusters (AA CuNCs). This yellow colored, biocompatible material exhibits emission maximum at 445 nm on an excitation wavelength of 365 nm. The fluorescence intensity of AA CuNCs was enhanced efficiently in presence of BVD within the linear range 1.00×10 −5 M to 2.00×10 −6 M with a limit of detection 2.88×10 −7 M. An aggregation induced emission enhancement (AIEE) mechanism was suggested for the sensor. Practical utility of the proposed sensor has been validated in artificial urine and blood serum.
- 19 October 2023
- Published by Wiley in ChemistrySelect
- Vol. 8 (39)
Ascorbic Acid‐Capped Copper Nanoclusters: A Turn‐On Fluorescence Sensor for Biliverdin
A simple and facile turn‐on fluorescence sensor has been developed for the effective determination of an important bile pigment‐ Biliverdin (BVD), using ascorbic acid capped copper nanoclusters (AA CuNCs). This yellow colored, biocompatible material exhibits emission maximum at 445 nm on an excitation wavelength of 365 nm. The fluorescence intensity of AA CuNCs was enhanced efficiently in presence of BVD within the linear range 1.00×10 −5 M to 2.00×10 −6 M with a limit of detection 2.88×10 −7 M. An aggregation induced emission enhancement (AIEE) mechanism was suggested for the sensor. Practical utility of the proposed sensor has been validated in artificial urine and blood serum.