Unni Sivasankaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Unni Sivasankaran has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Krishnapillai Girish Kumar
Cochin University of Science and Technology, Department of Applied Chemistry, Cochin University of Science and Technology, Kalamassery, Kochi, Kerala, 682022, INDIA
10 shared publications Krishnapillai Girish Kumar
6 shared publicationsAmmu Rosin Jose
Department of Applied Chemistry, Cochin University of Science and Technology, Kochi 682022, India
5 shared publications- Hanna Radecka
Polish Academy of Sciences in Olsztyn
3 shared publications - Jerzy Radecki
Institute of Animal Reproduction and Food Research, Polish Academy of Sciences, Tuwima 10, 10-748 Olsztyn, Poland
3 shared publications Shalini Menon
Department of Applied Chemistry, Cochin University of Science and Technology, Kochi, 22, India
3 shared publications
Latest Publications
- Open Access
- 1 October 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 321
Ultrasensitive electrochemical sensing of phosphate in water mediated by a dipicolylamine-zinc(II) complex
- 1 October 2020
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 321
Open AccessUltrasensitive electrochemical sensing of phosphate in water mediated by a dipicolylamine-zinc(II) complex
- 1 April 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 285, 536-545
Electrochemical sensing of sulfate in aqueous solution with a cyclopeptide-dipyrromethene-Cu(II) or Co(II) complex attached to a gold electrode
- 1 April 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 285, 536-545
Electrochemical sensing of sulfate in aqueous solution with a cyclopeptide-dipyrromethene-Cu(II) or Co(II) complex attached to a gold electrode
- 11 February 2019
- Published by Wiley in Luminescence
- Vol. 34 (2) , 243-248
Copper nanoclusters: an efficient fluorescence sensing platform for quinoline yellow
Fluorescence quenching behavior of artificial food colorant quinoline yellow (QY), on interaction with l‐cysteine stabilized copper nanoclusters (l‐Cys‐CuNCs) is investigated in this work. For this purpose, l‐cysteine stabilized CuNCs were synthesized and characterized using various analytical techniques. Results demonstrated that the synthesized probe (size ~2 nm) had very promising optical features such as bright blue fluorescence, significant quantum yield and excellent photostability. l‐Cys‐CuNCs can function as a fluorescence sensor by selectively sensing QY among other yellow colorants, giving a detection limit as low as 0.11 μM. The developed sensor exhibited a linear concentration range from 5.50 to 0.20 μM. The developed fluorescence assay was successfully applied for testing commercial samples, thereby making this sensing strategy significant for quality control of food stuffs.
- 11 February 2019
- Published by Wiley in Luminescence
- Vol. 34 (2) , 243-248
Copper nanoclusters: an efficient fluorescence sensing platform for quinoline yellow
Fluorescence quenching behavior of artificial food colorant quinoline yellow (QY), on interaction with l‐cysteine stabilized copper nanoclusters (l‐Cys‐CuNCs) is investigated in this work. For this purpose, l‐cysteine stabilized CuNCs were synthesized and characterized using various analytical techniques. Results demonstrated that the synthesized probe (size ~2 nm) had very promising optical features such as bright blue fluorescence, significant quantum yield and excellent photostability. l‐Cys‐CuNCs can function as a fluorescence sensor by selectively sensing QY among other yellow colorants, giving a detection limit as low as 0.11 μM. The developed sensor exhibited a linear concentration range from 5.50 to 0.20 μM. The developed fluorescence assay was successfully applied for testing commercial samples, thereby making this sensing strategy significant for quality control of food stuffs.
- 19 January 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (2) , B92-B94
Communication—Electrochemical Sensing of Synthetic Antioxidant Propyl Gallate: A Cost Effective Strategy Using Nanoparticles
Nanoparticles based quantification methods are convenient for food analysis, but incur a substantial cost. Consequently, the present study proposes a cost-effective technique for the voltammetric determination of the synthetic phenolic antioxidant propyl gallate (PG) using nickel nanoparticles modified glassy carbon electrode. Modified surface enhances the oxidation peak current and showed a reduction in peak potential. Under optimized experimental conditions, two linear ranges could be observed from 1.0 × 10−3 to 4.0 × 10−4 M and 3.0 × 10−4 to 2.0 × 10−6 M. Developed method was also applied in commercial food samples and the results were in agreement with those obtained from spectrophotometric method.
- 19 January 2019
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (2) , B92-B94
Communication—Electrochemical Sensing of Synthetic Antioxidant Propyl Gallate: A Cost Effective Strategy Using Nanoparticles
Nanoparticles based quantification methods are convenient for food analysis, but incur a substantial cost. Consequently, the present study proposes a cost-effective technique for the voltammetric determination of the synthetic phenolic antioxidant propyl gallate (PG) using nickel nanoparticles modified glassy carbon electrode. Modified surface enhances the oxidation peak current and showed a reduction in peak potential. Under optimized experimental conditions, two linear ranges could be observed from 1.0 × 10−3 to 4.0 × 10−4 M and 3.0 × 10−4 to 2.0 × 10−6 M. Developed method was also applied in commercial food samples and the results were in agreement with those obtained from spectrophotometric method.
- 2 November 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (14) , B746-B752
Biopolymer Based Electrochemical Sensor for Ponceau 4R: An Insight into Electrochemical Kinetics
Utility of biopolymer [poly(L-Cysteine)] modified glassy carbon electrode for the determination of Ponceau 4R (P4R), a food colorant, was explored during the present study. On the probe [poly(L-Cys)/GCE], P4R behaved as perfectly reversible redox system with Epa = 0.031 V and Epc = −0.001 V (ΔEp = 0.032 V). Significant decrease in the oxidation potential and remarkable increase in the current response of P4R on biopolymer modified GCE attests the excellent electron transfer capacity of the modified electrode towards the oxidation of P4R. Under optimal conditions, anodic peak current of P4R showed a linear behavior in the range 1.0 × 10−5 to 1.0 × 10−6 M, with minimum detectable concentration of 3.73 × 10−8 M. Kinetic parameters viz., charge transfer coefficient (α) and heterogeneous rate constant (ks) have also been determined. Chronocoulometry was employed to calculate saturated adsorption capacity and diffusion coefficient (D) and values obtained were 5.54 × 10−9 mol cm−2 and 2.93 × 10−6 cm2 s−1, respectively. Applicability of designed sensor was demonstrated in commercial soft drink samples.
- 2 November 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (14) , B746-B752
Biopolymer Based Electrochemical Sensor for Ponceau 4R: An Insight into Electrochemical Kinetics
Utility of biopolymer [poly(L-Cysteine)] modified glassy carbon electrode for the determination of Ponceau 4R (P4R), a food colorant, was explored during the present study. On the probe [poly(L-Cys)/GCE], P4R behaved as perfectly reversible redox system with Epa = 0.031 V and Epc = −0.001 V (ΔEp = 0.032 V). Significant decrease in the oxidation potential and remarkable increase in the current response of P4R on biopolymer modified GCE attests the excellent electron transfer capacity of the modified electrode towards the oxidation of P4R. Under optimal conditions, anodic peak current of P4R showed a linear behavior in the range 1.0 × 10−5 to 1.0 × 10−6 M, with minimum detectable concentration of 3.73 × 10−8 M. Kinetic parameters viz., charge transfer coefficient (α) and heterogeneous rate constant (ks) have also been determined. Chronocoulometry was employed to calculate saturated adsorption capacity and diffusion coefficient (D) and values obtained were 5.54 × 10−9 mol cm−2 and 2.93 × 10−6 cm2 s−1, respectively. Applicability of designed sensor was demonstrated in commercial soft drink samples.
- 1 March 2018
- Published by Elsevier in Analytical Biochemistry
- Vol. 544, 1-6
Selective recognition of creatinine – Development of a colorimetric sensor
- 1 March 2018
- Published by Elsevier in Analytical Biochemistry
- Vol. 544, 1-6
Selective recognition of creatinine – Development of a colorimetric sensor
- 1 January 2018
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 188, 113-119
Biothiols induced colour change of silver nanoparticles: A colorimetric sensing strategy
- 1 January 2018
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 188, 113-119
Biothiols induced colour change of silver nanoparticles: A colorimetric sensing strategy
- 12 April 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (6) , B292-B297
Poly (Bromophenol Blue)-Gold Nanoparticle Composite: An Efficient Electrochemical Sensing Platform for Uric Acid
A simple voltammetric sensor has been developed for direct determination of important biomarker uric acid (UA) based on poly bromophenol blue - gold nanoparticles composite modified glassy carbon electrode. Scanning electron microscopy, atomic force microscopy and various electrochemical techniques were used for characterization of modified electrode surface. The electro-oxidation of UA in 0.1 M NaOH was excellently catalyzed by modified electrode. The anodic peak corresponding to the oxidation of UA was observed at a potential of −105 mV by Square wave voltammetry (SWV). The oxidation peak current was increased linearly on increasing the concentration of UA in the range 1.0 × 10−3 to 2.0 × 10−5 M (R2 = 0.994) with a limit of detection 2.2 × 10−6 M. The proposed method was effectively applied to determine Uric acid in artificial blood serum and urine samples. The developed sensor would be a potential alternative tool for UA determination in biological samples.
- 12 April 2017
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 164 (6) , B292-B297
Poly (Bromophenol Blue)-Gold Nanoparticle Composite: An Efficient Electrochemical Sensing Platform for Uric Acid
A simple voltammetric sensor has been developed for direct determination of important biomarker uric acid (UA) based on poly bromophenol blue - gold nanoparticles composite modified glassy carbon electrode. Scanning electron microscopy, atomic force microscopy and various electrochemical techniques were used for characterization of modified electrode surface. The electro-oxidation of UA in 0.1 M NaOH was excellently catalyzed by modified electrode. The anodic peak corresponding to the oxidation of UA was observed at a potential of −105 mV by Square wave voltammetry (SWV). The oxidation peak current was increased linearly on increasing the concentration of UA in the range 1.0 × 10−3 to 2.0 × 10−5 M (R2 = 0.994) with a limit of detection 2.2 × 10−6 M. The proposed method was effectively applied to determine Uric acid in artificial blood serum and urine samples. The developed sensor would be a potential alternative tool for UA determination in biological samples.