Tobias Speidel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tobias Speidel has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Volker Rasche
Department of Internal Medicine II, Ulm University Medical Center, Ulm, Germany
5 shared publications - Patrick Metze
Department of Internal Medicine II, Ulm University Medical Center, Ulm, Germany
3 shared publications - Ambros Johannes Beer
Department of Nuclear Medicine, University Hospital Ulm, 89081 Ulm, Germany
1 shared publication - Bernd Manfred Muehling
Department of Thoracic and Vascular Surgery, University of Ulm, Ulm, Germany
1 shared publication - Catharina Silvia Lisson
Department of Diagnostic and Interventional Radiology, University Hospital of Ulm, Albert-Einstein-Allee 23, 89081 Ulm, Germany
1 shared publication - Dominik Buckert
Department of Internal Medicine II, University Medical Center, 89081 Ulm, Germany
1 shared publication
Latest Publications
- Open Access
- 16 August 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (16) , 1787
From Phantoms to Patients: Improved Fusion and Voxel-Wise Analysis of Diffusion-Weighted Imaging and FDG-Positron Emission Tomography in Positron Emission Tomography/Magnetic Resonance Imaging for Combined Metabolic–Diffusivity Index (cDMI)
Hybrid positron emission tomography/magnetic resonance imaging (PET/MR) opens new possibilities in multimodal multiparametric (m2p) image analyses. But even the simultaneous acquisition of positron emission tomography (PET) and magnetic resonance imaging (MRI) does not guarantee perfect voxel-by-voxel co-registration due to organs and distortions, especially in diffusion-weighted imaging (DWI), which would be, however, crucial to derive biologically meaningful information. Thus, our aim was to optimize fusion and voxel-wise analyses of DWI and standardized uptake values (SUVs) using a novel software for m2p analyses. Using research software, we evaluated the precision of image co-registration and voxel-wise analyses including the rigid and elastic 3D registration of DWI and [18F]-Fluorodeoxyglucose (FDG)-PET from an integrated PET/MR system. We analyzed DWI distortions with a volume-preserving constraint in three different 3D-printed phantom models. A total of 12 PET/MR-DWI clinical datasets (bronchial carcinoma patients) were referenced to the T1 weighted-DIXON sequence. Back mapping of scatterplots and voxel-wise registration was performed and compared to the non-optimized datasets. Fusion was rated using a 5-point Likert scale. Using the 3D-elastic co-registration algorithm, geometric shapes were restored in phantom measurements; the measured ADC values did not change significantly (F = 1.12, p = 0.34). Reader assessment showed a significant improvement in fusion precision for DWI and morphological landmarks in the 3D-registered datasets (4.3 ± 0.2 vs. 4.6 ± 0.2, p = 0.009). Most pronounced differences were noted for the chest wall (p = 0.006), tumor (p = 0.007), and skin contour (p = 0.014). Co-registration increased the number of plausible ADC and SUV combinations by 25%. The volume-preserving elastic 3D registration of DWI significantly improved the precision of fusion with anatomical sequences in phantom and clinical datasets. The research software allowed for a voxel-wise analysis and visualization of [18F]FDG-PET/MR data as a “combined diffusivity–metabolic index” (cDMI). The clinical value of the optimized PET/MR biomarker can thus be tested in future PET/MR studies.
- 16 August 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (16) , 1787
Open AccessFrom Phantoms to Patients: Improved Fusion and Voxel-Wise Analysis of Diffusion-Weighted Imaging and FDG-Positron Emission Tomography in Positron Emission Tomography/Magnetic Resonance Imaging for Combined Metabolic–Diffusivity Index (cDMI)
Hybrid positron emission tomography/magnetic resonance imaging (PET/MR) opens new possibilities in multimodal multiparametric (m2p) image analyses. But even the simultaneous acquisition of positron emission tomography (PET) and magnetic resonance imaging (MRI) does not guarantee perfect voxel-by-voxel co-registration due to organs and distortions, especially in diffusion-weighted imaging (DWI), which would be, however, crucial to derive biologically meaningful information. Thus, our aim was to optimize fusion and voxel-wise analyses of DWI and standardized uptake values (SUVs) using a novel software for m2p analyses. Using research software, we evaluated the precision of image co-registration and voxel-wise analyses including the rigid and elastic 3D registration of DWI and [18F]-Fluorodeoxyglucose (FDG)-PET from an integrated PET/MR system. We analyzed DWI distortions with a volume-preserving constraint in three different 3D-printed phantom models. A total of 12 PET/MR-DWI clinical datasets (bronchial carcinoma patients) were referenced to the T1 weighted-DIXON sequence. Back mapping of scatterplots and voxel-wise registration was performed and compared to the non-optimized datasets. Fusion was rated using a 5-point Likert scale. Using the 3D-elastic co-registration algorithm, geometric shapes were restored in phantom measurements; the measured ADC values did not change significantly (F = 1.12, p = 0.34). Reader assessment showed a significant improvement in fusion precision for DWI and morphological landmarks in the 3D-registered datasets (4.3 ± 0.2 vs. 4.6 ± 0.2, p = 0.009). Most pronounced differences were noted for the chest wall (p = 0.006), tumor (p = 0.007), and skin contour (p = 0.014). Co-registration increased the number of plausible ADC and SUV combinations by 25%. The volume-preserving elastic 3D registration of DWI significantly improved the precision of fusion with anatomical sequences in phantom and clinical datasets. The research software allowed for a voxel-wise analysis and visualization of [18F]FDG-PET/MR data as a “combined diffusivity–metabolic index” (cDMI). The clinical value of the optimized PET/MR biomarker can thus be tested in future PET/MR studies.
- Open Access
- 9 June 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Design and Analysis of Field-of-View Independent k-Space Trajectories for Magnetic Resonance Imaging
This manuscript describes a method of three-dimensional k-space sampling that is based on a generalised form of the previously introduced “Seiffert Spirals,” which exploits the equality between undersampling and the reconstruction of a field of view which is larger than what is represented by the primary sampling density, leading to an imaging approach that does not require any prior commitment to an imaging field of view. The concept of reconstructing arbitrary FOVs based on a low-coherently sampled k-space is demonstrated analytically by simulations of the corresponding point spread functions and by an analysis of the noise power spectrum of undersampled datasets. In-vivo images highlight the feasibility of the presented approach by reconstructing white noise governed images from an undersampled datasets with a smaller encoded FOV. Beneficial properties are especially given by an artefact behaviour, which is widely comparable to the introduction of white noise in the image domain. Furthermore, these aliasing properties provide a promising precondition for the combination with non-linear reconstruction techniques such as Compressed Sensing. All presented results show dominant low-coherent aliasing properties, leading to a noise-like aliasing behaviour, which enables parameterization of the imaging sequence according to a given resolution and scan-time, without the need for FOV considerations.
- 9 June 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessDesign and Analysis of Field-of-View Independent k-Space Trajectories for Magnetic Resonance Imaging
This manuscript describes a method of three-dimensional k-space sampling that is based on a generalised form of the previously introduced “Seiffert Spirals,” which exploits the equality between undersampling and the reconstruction of a field of view which is larger than what is represented by the primary sampling density, leading to an imaging approach that does not require any prior commitment to an imaging field of view. The concept of reconstructing arbitrary FOVs based on a low-coherently sampled k-space is demonstrated analytically by simulations of the corresponding point spread functions and by an analysis of the noise power spectrum of undersampled datasets. In-vivo images highlight the feasibility of the presented approach by reconstructing white noise governed images from an undersampled datasets with a smaller encoded FOV. Beneficial properties are especially given by an artefact behaviour, which is widely comparable to the introduction of white noise in the image domain. Furthermore, these aliasing properties provide a promising precondition for the combination with non-linear reconstruction techniques such as Compressed Sensing. All presented results show dominant low-coherent aliasing properties, leading to a noise-like aliasing behaviour, which enables parameterization of the imaging sequence according to a given resolution and scan-time, without the need for FOV considerations.
- 2 August 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (3) , 236-244
Sliding window reduced FOV reconstruction for real-time cardiac imaging
- 2 August 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (3) , 236-244
Sliding window reduced FOV reconstruction for real-time cardiac imaging
- 20 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (8) , 1833-1840
Efficient 3D Low-Discrepancy ${k}$ -Space Sampling Using Highly Adaptable Seiffert SpiralsThe overall duration of acquiring a Nyquist sampled 3D dataset can be significantly shortened by enhancing the efficiency of ${k}$ -space sampling. This can be achieved by increasing the coverage of ${k}$ -space for every trajectory interleave. Furthermore, acceleration is possible by making use of advantageous undersampling properties. In this paper, a versatile 3D center-out ${k}$ -space trajectory based on Jacobian elliptic functions (Seiffert’s spiral) is presented. The trajectory leads to a low-discrepancy coverage of ${k}$ -space using a considerably reduced number of readouts compared with other approaches. Such a coverage is achieved for any number of interleaves, and, therefore, even single-shot trajectories can be constructed to be combined with, for example, hyperpolarized media. Furthermore, acceleration is achievable due to non-coherent undersampling properties of the trajectory in combination with non-linear reconstruction techniques like compressed sensing (CS). Simulations of point-spread functions and discrepancy evaluations compare Seiffert’s spiral to the established 3D cones approach. Imaging capabilities are evaluated by comparison of in vivo knee images using Nyquist and undersampled datasets in combination with CS reconstructions.
- 20 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (8) , 1833-1840
Efficient 3D Low-Discrepancy ${k}$ -Space Sampling Using Highly Adaptable Seiffert SpiralsThe overall duration of acquiring a Nyquist sampled 3D dataset can be significantly shortened by enhancing the efficiency of ${k}$ -space sampling. This can be achieved by increasing the coverage of ${k}$ -space for every trajectory interleave. Furthermore, acceleration is possible by making use of advantageous undersampling properties. In this paper, a versatile 3D center-out ${k}$ -space trajectory based on Jacobian elliptic functions (Seiffert’s spiral) is presented. The trajectory leads to a low-discrepancy coverage of ${k}$ -space using a considerably reduced number of readouts compared with other approaches. Such a coverage is achieved for any number of interleaves, and, therefore, even single-shot trajectories can be constructed to be combined with, for example, hyperpolarized media. Furthermore, acceleration is achievable due to non-coherent undersampling properties of the trajectory in combination with non-linear reconstruction techniques like compressed sensing (CS). Simulations of point-spread functions and discrepancy evaluations compare Seiffert’s spiral to the established 3D cones approach. Imaging capabilities are evaluated by comparison of in vivo knee images using Nyquist and undersampled datasets in combination with CS reconstructions.
- 9 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (2) , 473-479
Quasi-Random Single-Point Imaging Using Low-Discrepancy $k$ -Space SamplingMR imaging of short relaxation times spin systems has been a widely discussed topic with serious clinical applications and led to the emergence of fast imaging ultra-short echo-time sequences. Nevertheless, these sequences suffer from image blurring due to the related sampling point spread function and are highly prone to imaging artefacts arising from e.g. chemical shifts or magnetic susceptibilities. In this work, we present a concept of spherical quasi-random single-point imaging. The approach is highly accelerateable due to intrinsic undersampling properties and capable of strong metal artefact suppression. Imaging acceleration is achieved by sampling of quasirandom points in k-space, based on a low-discrepancy sequence, and a combination with non-linear optimisation reconstruction techniques (Compressed Sensing). The presented low-discrepancy trajectory shows ideal noise-like undersampling properties for the combination with Compressed Sensing (CS), leading to denoised images with excellent metal artefact reduction. Using eight-fold undersampling, acquisition times of few minutes can be achieved for volume acquisitions.
- 9 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 37 (2) , 473-479
Quasi-Random Single-Point Imaging Using Low-Discrepancy $k$ -Space SamplingMR imaging of short relaxation times spin systems has been a widely discussed topic with serious clinical applications and led to the emergence of fast imaging ultra-short echo-time sequences. Nevertheless, these sequences suffer from image blurring due to the related sampling point spread function and are highly prone to imaging artefacts arising from e.g. chemical shifts or magnetic susceptibilities. In this work, we present a concept of spherical quasi-random single-point imaging. The approach is highly accelerateable due to intrinsic undersampling properties and capable of strong metal artefact suppression. Imaging acceleration is achieved by sampling of quasirandom points in k-space, based on a low-discrepancy sequence, and a combination with non-linear optimisation reconstruction techniques (Compressed Sensing). The presented low-discrepancy trajectory shows ideal noise-like undersampling properties for the combination with Compressed Sensing (CS), leading to denoised images with excellent metal artefact reduction. Using eight-fold undersampling, acquisition times of few minutes can be achieved for volume acquisitions.