Patrick Metze
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Patrick Metze has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Volker Rasche
Department of Internal Medicine II, Ulm University Medical Center, Ulm, Germany
9 shared publications - Hao Li
Core Facility Small Animal Imaging, Ulm University, Ulm, Germany
4 shared publications Steffen Just
Department of Internal Medicine II, Ulm University Medical Center, Ulm, Germany
3 shared publications- Tobias Speidel
Department of Internal Medicine II, University Hospital of Ulm, Ulm, Germany
3 shared publications - Wolfgang Rottbauer
Ulm University Heart Center
3 shared publications Alireza Abaei
Core Facility Small Animal Imaging, Ulm University, Ulm, Germany
2 shared publications
Latest Publications
- Open Access
- 23 January 2024
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 113, 102340
Multi-network approach for image segmentation in non-contrast enhanced cardiac 3D MRI of arrhythmic patients
- 23 January 2024
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 113, 102340
Open AccessMulti-network approach for image segmentation in non-contrast enhanced cardiac 3D MRI of arrhythmic patients
- Open Access
- 9 June 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Design and Analysis of Field-of-View Independent k-Space Trajectories for Magnetic Resonance Imaging
This manuscript describes a method of three-dimensional k-space sampling that is based on a generalised form of the previously introduced “Seiffert Spirals,” which exploits the equality between undersampling and the reconstruction of a field of view which is larger than what is represented by the primary sampling density, leading to an imaging approach that does not require any prior commitment to an imaging field of view. The concept of reconstructing arbitrary FOVs based on a low-coherently sampled k-space is demonstrated analytically by simulations of the corresponding point spread functions and by an analysis of the noise power spectrum of undersampled datasets. In-vivo images highlight the feasibility of the presented approach by reconstructing white noise governed images from an undersampled datasets with a smaller encoded FOV. Beneficial properties are especially given by an artefact behaviour, which is widely comparable to the introduction of white noise in the image domain. Furthermore, these aliasing properties provide a promising precondition for the combination with non-linear reconstruction techniques such as Compressed Sensing. All presented results show dominant low-coherent aliasing properties, leading to a noise-like aliasing behaviour, which enables parameterization of the imaging sequence according to a given resolution and scan-time, without the need for FOV considerations.
- 9 June 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessDesign and Analysis of Field-of-View Independent k-Space Trajectories for Magnetic Resonance Imaging
This manuscript describes a method of three-dimensional k-space sampling that is based on a generalised form of the previously introduced “Seiffert Spirals,” which exploits the equality between undersampling and the reconstruction of a field of view which is larger than what is represented by the primary sampling density, leading to an imaging approach that does not require any prior commitment to an imaging field of view. The concept of reconstructing arbitrary FOVs based on a low-coherently sampled k-space is demonstrated analytically by simulations of the corresponding point spread functions and by an analysis of the noise power spectrum of undersampled datasets. In-vivo images highlight the feasibility of the presented approach by reconstructing white noise governed images from an undersampled datasets with a smaller encoded FOV. Beneficial properties are especially given by an artefact behaviour, which is widely comparable to the introduction of white noise in the image domain. Furthermore, these aliasing properties provide a promising precondition for the combination with non-linear reconstruction techniques such as Compressed Sensing. All presented results show dominant low-coherent aliasing properties, leading to a noise-like aliasing behaviour, which enables parameterization of the imaging sequence according to a given resolution and scan-time, without the need for FOV considerations.
- Open Access
- 8 April 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (8) , 2088
Real-Time Spiral CMR Is Superior to Conventional Segmented Cine-Imaging for Left-Ventricular Functional Assessment in Patients with Arrhythmia
(1) Background: Segmented Cartesian Cardiovascular magnetic resonance (CMR) often fails to deliver robust assessment of cardiac function in patients with arrhythmia. We aimed to assess the performance of a tiny golden-angle spiral real-time CMR sequence at 1.5 T for left-ventricular (LV) volumetry in patients with irregular heart rhythm; (2) Methods: We validated the real-time sequence against the standard breath-hold segmented Cartesian sequence in 32 patients, of whom 11 presented with arrhythmia. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were assessed. In arrhythmic patients, real-time and standard Cartesian acquisitions were compared against a reference echocardiographic modality; (3) Results: In patients with sinus rhythm, good agreements and correlations were found between the segmented and real-time methods, with only minor, non-significant underestimation of EDV for the real-time sequence (135.95 ± 30 mL vs. 137.15 ± 31, p = 0.164). In patients with arrhythmia, spiral real-time CMR yielded superior image quality to the conventional segmented imaging, allowing for excellent agreement with the reference echocardiographic volumetry. In contrast, in this cohort, standard Cartesian CMR showed significant underestimation of LV-ESV (106.72 ± 63.51 mL vs. 125.47 ± 72.41 mL, p = 0.026) and overestimation of LVEF (42.96 ± 10.81% vs. 39.02 ± 11.72%, p = 0.039); (4) Conclusions: Real-time spiral CMR improves image quality in arrhythmic patients, allowing reliable assessment of LV volumetry.
- 8 April 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (8) , 2088
Open AccessReal-Time Spiral CMR Is Superior to Conventional Segmented Cine-Imaging for Left-Ventricular Functional Assessment in Patients with Arrhythmia
(1) Background: Segmented Cartesian Cardiovascular magnetic resonance (CMR) often fails to deliver robust assessment of cardiac function in patients with arrhythmia. We aimed to assess the performance of a tiny golden-angle spiral real-time CMR sequence at 1.5 T for left-ventricular (LV) volumetry in patients with irregular heart rhythm; (2) Methods: We validated the real-time sequence against the standard breath-hold segmented Cartesian sequence in 32 patients, of whom 11 presented with arrhythmia. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were assessed. In arrhythmic patients, real-time and standard Cartesian acquisitions were compared against a reference echocardiographic modality; (3) Results: In patients with sinus rhythm, good agreements and correlations were found between the segmented and real-time methods, with only minor, non-significant underestimation of EDV for the real-time sequence (135.95 ± 30 mL vs. 137.15 ± 31, p = 0.164). In patients with arrhythmia, spiral real-time CMR yielded superior image quality to the conventional segmented imaging, allowing for excellent agreement with the reference echocardiographic volumetry. In contrast, in this cohort, standard Cartesian CMR showed significant underestimation of LV-ESV (106.72 ± 63.51 mL vs. 125.47 ± 72.41 mL, p = 0.026) and overestimation of LVEF (42.96 ± 10.81% vs. 39.02 ± 11.72%, p = 0.039); (4) Conclusions: Real-time spiral CMR improves image quality in arrhythmic patients, allowing reliable assessment of LV volumetry.
- Open Access
- 4 March 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Non-Uniform Self-Gating in 2D Lung Imaging
Purpose: To adapt the non-uniform Self-Gating (nuSG) method and compare it to established self-gating approaches for lung imaging in uniform and highly irregular respiratory patterns.Methods: Six healthy volunteers underwent free breathing lung MRI using a radial tiny golden angle ultrashort echo-time sequence. Acquisitions were performed with the volunteer breathing as uniformly as possible and with a deliberately non-uniform respiratory pattern. The acquired data was reconstructed with the nuSG method, previously introduced for cardiac imaging and imaging of the temporomandibular joint (TMJ) and compared to established k-space based and image-based self-gating approaches. Residual motion blur, SNR and functional values were assessed and compared to reference breath-hold acquisitions.Results: nuSG is capable of reconstructing high-quality images for uniform and non-uniform breathing patterns and is furthermore capable of resolving motion in cases where additional motion is superimposed or no clear motion surrogate exists. Derived functional values do not differ significantly from other image-based gated reconstructions - and in the case of non-uniform respiratory patterns replicate the reference BH values.Conclusion: Image based approaches are computationally more demanding but yield better results in all aspects. In scenarios with a direct surrogate for respiratory motion (i.e. the lung-liver interface) the extraction of a one-dimensional navigator is sufficient. When there is no direct surrogate for the motion of the target structure available (e.g., considerable through-plane motion or a different source of motion), the two-dimensional correlation-based measure used in nuSG is able to track the motion more accurately.
- 4 March 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessNon-Uniform Self-Gating in 2D Lung Imaging
Purpose: To adapt the non-uniform Self-Gating (nuSG) method and compare it to established self-gating approaches for lung imaging in uniform and highly irregular respiratory patterns.Methods: Six healthy volunteers underwent free breathing lung MRI using a radial tiny golden angle ultrashort echo-time sequence. Acquisitions were performed with the volunteer breathing as uniformly as possible and with a deliberately non-uniform respiratory pattern. The acquired data was reconstructed with the nuSG method, previously introduced for cardiac imaging and imaging of the temporomandibular joint (TMJ) and compared to established k-space based and image-based self-gating approaches. Residual motion blur, SNR and functional values were assessed and compared to reference breath-hold acquisitions.Results: nuSG is capable of reconstructing high-quality images for uniform and non-uniform breathing patterns and is furthermore capable of resolving motion in cases where additional motion is superimposed or no clear motion surrogate exists. Derived functional values do not differ significantly from other image-based gated reconstructions - and in the case of non-uniform respiratory patterns replicate the reference BH values.Conclusion: Image based approaches are computationally more demanding but yield better results in all aspects. In scenarios with a direct surrogate for respiratory motion (i.e. the lung-liver interface) the extraction of a one-dimensional navigator is sufficient. When there is no direct surrogate for the motion of the target structure available (e.g., considerable through-plane motion or a different source of motion), the two-dimensional correlation-based measure used in nuSG is able to track the motion more accurately.
- 1 October 2021
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 82, 24-30
Tiny golden angle stack-of-stars (tygaSoS) free-breathing functional lung imaging
- 1 October 2021
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 82, 24-30
Tiny golden angle stack-of-stars (tygaSoS) free-breathing functional lung imaging
- Open Access
- 23 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Quantification of Biventricular Myocardial Strain Using CMR Feature Tracking: Reproducibility in Small Animals
Myocardial strain is a well‐validated parameter for evaluating myocardial contraction. Cardiovascular magnetic resonance myocardial feature tracking (CMR‐FT) is a novel method for the quantitative measurements of myocardial strain from routine cine acquisitions. In this study, we investigated the influence of temporal resolution on tracking accuracy of CMR‐FT and the intraobserver, interobserver, and interstudy reproducibilities for biventricular strain analysis in mice from self‐gated CMR at 11.7 T. 12 constitutive nexilin knockout (Nexn‐KO) mice, heterozygous (Het, N = 6) and wild‐type (WT, N = 6), were measured with a well‐established self‐gating sequence twice within two weeks. CMR‐FT measures of biventricular global and segmental strain parameters were derived. Interstudy, intraobserver, and interobserver reproducibilities were investigated. For the assessment of the impact of the temporal resolution for the outcome in CMR‐FT, highly oversampled semi‐4 chamber and midventricular short‐axis data were acquired and reconstructed with 10 to 80 phases per cardiac cycle. A generally reduced biventricular myocardial strain was observed in Nexn‐KO Het mice. Excellent intraobserver and interobserver reproducibility was achieved in all global strains (ICC range from 0.76 to 0.99), where global right ventricle circumferential strain (RCSSAX) showed an only good interobserver reproducibility (ICC 0.65, 0.11‐0.89). For interstudy reproducibility, left ventricle longitudinal strain (LLSLAX) was the most reproducible measure of strain (ICC 0.90, 0.71‐0.97). The left ventricle radial strain (LRSSAX) (ICC 0.50, 0.10‐0.83) showed fair reproducibility and RCSSAX (ICC 0.36, 0.14‐0.74) showed only poor reproducibility. In general, compared with global strains, the segmental strains showed relatively lower reproducibility. A minimal temporal resolution of 20 phases per cardiac cycle appeared sufficient for CMR‐FT strain analysis. The analysis of myocardial strain from high‐resolution self‐gated cine images by CMR‐FT provides a highly reproducible method for assessing myocardial contraction in small rodent animals. Especially, global LV longitudinal and circumferential strain revealed excellent reproducibility of intra‐ and interobserver and interstudy measurements.
- 23 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Open AccessQuantification of Biventricular Myocardial Strain Using CMR Feature Tracking: Reproducibility in Small Animals
Myocardial strain is a well‐validated parameter for evaluating myocardial contraction. Cardiovascular magnetic resonance myocardial feature tracking (CMR‐FT) is a novel method for the quantitative measurements of myocardial strain from routine cine acquisitions. In this study, we investigated the influence of temporal resolution on tracking accuracy of CMR‐FT and the intraobserver, interobserver, and interstudy reproducibilities for biventricular strain analysis in mice from self‐gated CMR at 11.7 T. 12 constitutive nexilin knockout (Nexn‐KO) mice, heterozygous (Het, N = 6) and wild‐type (WT, N = 6), were measured with a well‐established self‐gating sequence twice within two weeks. CMR‐FT measures of biventricular global and segmental strain parameters were derived. Interstudy, intraobserver, and interobserver reproducibilities were investigated. For the assessment of the impact of the temporal resolution for the outcome in CMR‐FT, highly oversampled semi‐4 chamber and midventricular short‐axis data were acquired and reconstructed with 10 to 80 phases per cardiac cycle. A generally reduced biventricular myocardial strain was observed in Nexn‐KO Het mice. Excellent intraobserver and interobserver reproducibility was achieved in all global strains (ICC range from 0.76 to 0.99), where global right ventricle circumferential strain (RCSSAX) showed an only good interobserver reproducibility (ICC 0.65, 0.11‐0.89). For interstudy reproducibility, left ventricle longitudinal strain (LLSLAX) was the most reproducible measure of strain (ICC 0.90, 0.71‐0.97). The left ventricle radial strain (LRSSAX) (ICC 0.50, 0.10‐0.83) showed fair reproducibility and RCSSAX (ICC 0.36, 0.14‐0.74) showed only poor reproducibility. In general, compared with global strains, the segmental strains showed relatively lower reproducibility. A minimal temporal resolution of 20 phases per cardiac cycle appeared sufficient for CMR‐FT strain analysis. The analysis of myocardial strain from high‐resolution self‐gated cine images by CMR‐FT provides a highly reproducible method for assessing myocardial contraction in small rodent animals. Especially, global LV longitudinal and circumferential strain revealed excellent reproducibility of intra‐ and interobserver and interstudy measurements.
- 2 August 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (3) , 236-244
Sliding window reduced FOV reconstruction for real-time cardiac imaging
- 2 August 2020
- Published by Elsevier in Zeitschrift für Medizinische Physik
- Vol. 30 (3) , 236-244
Sliding window reduced FOV reconstruction for real-time cardiac imaging
- Open Access
- 10 June 2020
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 8
Technical Aspects of in vivo Small Animal CMR Imaging
Cardiovascular magnetic resonance (CMR) imaging has become an accurate and versatile imaging modality to visualize the cardiovascular system in normal or abnormal conditions. In preclinical research, small rodent animal models of human cardiovascular diseases are frequently used to investigate the basic underlying mechanism of normal and abnormal cardiac function and for monitoring the disease progression under therapy. Technical improvements have enabled the transfer of CMR to small animal research, and as such made this non-invasive technique available to provide insights into cardiac morphology, function, perfusion, and pathophysiology in small animal cardiac disease models. This article reviews the basic technical approaches to in vivo small animal magnetic resonance imaging and its variants for the most promising applications.
- 10 June 2020
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 8
Open AccessTechnical Aspects of in vivo Small Animal CMR Imaging
Cardiovascular magnetic resonance (CMR) imaging has become an accurate and versatile imaging modality to visualize the cardiovascular system in normal or abnormal conditions. In preclinical research, small rodent animal models of human cardiovascular diseases are frequently used to investigate the basic underlying mechanism of normal and abnormal cardiac function and for monitoring the disease progression under therapy. Technical improvements have enabled the transfer of CMR to small animal research, and as such made this non-invasive technique available to provide insights into cardiac morphology, function, perfusion, and pathophysiology in small animal cardiac disease models. This article reviews the basic technical approaches to in vivo small animal magnetic resonance imaging and its variants for the most promising applications.
- Open Access
- 29 March 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (7) , e4300
Feasibility of real‐time cardiac MRI in mice using tiny golden angle radial sparse
Cardiovascular magnetic resonance imaging has proven valuable for the assessment of structural and functional cardiac abnormalities. Even although it is an established imaging method in small animals, the long acquisition times of gated or self‐gated techniques still limit its widespread application. In this study, the application of tiny golden angle radial sparse MRI (tyGRASP) for real‐time cardiac imaging was tested in 12 constitutive nexilin (Nexn) knock‐out (KO) mice, both heterozygous (Het, N = 6) and wild‐type (WT, N = 6), and the resulting functional parameters were compared with a well‐established self‐gating approach. Real‐time images were reconstructed for different temporal resolutions of between 16.8 and 79.8 ms per image. The suggested approach was additionally tested for dobutamine stress and qualitative first‐pass perfusion imaging. Measurements were repeated twice within 2 weeks for reproducibility assessment. In direct comparison with the high‐quality, self‐gated technique, the real‐time approach did not show any significant differences in global function parameters for acquisition times below 50 ms (rest) and 31.5 ms (stress). Compared with WT, the end‐diastolic volume (EDV) and end‐systolic volume (ESV) were markedly higher (P < 0.05) and the ejection fraction (EF) was significantly lower in the Het Nexn‐KO mice at rest (P < 0.001). For the stress investigation, a clear decrease of EDV and ESV, and an increase in EF, but maintained stroke volume, could be observed in both groups. Combined with ECG‐triggering, tyGRASP provided first‐pass perfusion data with a temporal resolution of one image per heartbeat, allowing the quantitative assessment of upslope curves in the blood‐pool and myocardium. Excellent inter‐study reproducibility was achieved in all the functional parameters. The tyGRASP is a valuable real‐time MRI technique for mice, which significantly reduces the scan time in preclinical cardiac functional imaging, providing sufficient image quality for deriving accurate functional parameters, and has the potential to investigate real‐time and beat‐to‐beat changes.
- 29 March 2020
- Published by Wiley in NMR in Biomedicine
- Vol. 33 (7) , e4300
Open AccessFeasibility of real‐time cardiac MRI in mice using tiny golden angle radial sparse
Cardiovascular magnetic resonance imaging has proven valuable for the assessment of structural and functional cardiac abnormalities. Even although it is an established imaging method in small animals, the long acquisition times of gated or self‐gated techniques still limit its widespread application. In this study, the application of tiny golden angle radial sparse MRI (tyGRASP) for real‐time cardiac imaging was tested in 12 constitutive nexilin (Nexn) knock‐out (KO) mice, both heterozygous (Het, N = 6) and wild‐type (WT, N = 6), and the resulting functional parameters were compared with a well‐established self‐gating approach. Real‐time images were reconstructed for different temporal resolutions of between 16.8 and 79.8 ms per image. The suggested approach was additionally tested for dobutamine stress and qualitative first‐pass perfusion imaging. Measurements were repeated twice within 2 weeks for reproducibility assessment. In direct comparison with the high‐quality, self‐gated technique, the real‐time approach did not show any significant differences in global function parameters for acquisition times below 50 ms (rest) and 31.5 ms (stress). Compared with WT, the end‐diastolic volume (EDV) and end‐systolic volume (ESV) were markedly higher (P < 0.05) and the ejection fraction (EF) was significantly lower in the Het Nexn‐KO mice at rest (P < 0.001). For the stress investigation, a clear decrease of EDV and ESV, and an increase in EF, but maintained stroke volume, could be observed in both groups. Combined with ECG‐triggering, tyGRASP provided first‐pass perfusion data with a temporal resolution of one image per heartbeat, allowing the quantitative assessment of upslope curves in the blood‐pool and myocardium. Excellent inter‐study reproducibility was achieved in all the functional parameters. The tyGRASP is a valuable real‐time MRI technique for mice, which significantly reduces the scan time in preclinical cardiac functional imaging, providing sufficient image quality for deriving accurate functional parameters, and has the potential to investigate real‐time and beat‐to‐beat changes.
- 20 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (8) , 1833-1840
Efficient 3D Low-Discrepancy ${k}$ -Space Sampling Using Highly Adaptable Seiffert SpiralsThe overall duration of acquiring a Nyquist sampled 3D dataset can be significantly shortened by enhancing the efficiency of ${k}$ -space sampling. This can be achieved by increasing the coverage of ${k}$ -space for every trajectory interleave. Furthermore, acceleration is possible by making use of advantageous undersampling properties. In this paper, a versatile 3D center-out ${k}$ -space trajectory based on Jacobian elliptic functions (Seiffert’s spiral) is presented. The trajectory leads to a low-discrepancy coverage of ${k}$ -space using a considerably reduced number of readouts compared with other approaches. Such a coverage is achieved for any number of interleaves, and, therefore, even single-shot trajectories can be constructed to be combined with, for example, hyperpolarized media. Furthermore, acceleration is achievable due to non-coherent undersampling properties of the trajectory in combination with non-linear reconstruction techniques like compressed sensing (CS). Simulations of point-spread functions and discrepancy evaluations compare Seiffert’s spiral to the established 3D cones approach. Imaging capabilities are evaluated by comparison of in vivo knee images using Nyquist and undersampled datasets in combination with CS reconstructions.
- 20 December 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (8) , 1833-1840
Efficient 3D Low-Discrepancy ${k}$ -Space Sampling Using Highly Adaptable Seiffert SpiralsThe overall duration of acquiring a Nyquist sampled 3D dataset can be significantly shortened by enhancing the efficiency of ${k}$ -space sampling. This can be achieved by increasing the coverage of ${k}$ -space for every trajectory interleave. Furthermore, acceleration is possible by making use of advantageous undersampling properties. In this paper, a versatile 3D center-out ${k}$ -space trajectory based on Jacobian elliptic functions (Seiffert’s spiral) is presented. The trajectory leads to a low-discrepancy coverage of ${k}$ -space using a considerably reduced number of readouts compared with other approaches. Such a coverage is achieved for any number of interleaves, and, therefore, even single-shot trajectories can be constructed to be combined with, for example, hyperpolarized media. Furthermore, acceleration is achievable due to non-coherent undersampling properties of the trajectory in combination with non-linear reconstruction techniques like compressed sensing (CS). Simulations of point-spread functions and discrepancy evaluations compare Seiffert’s spiral to the established 3D cones approach. Imaging capabilities are evaluated by comparison of in vivo knee images using Nyquist and undersampled datasets in combination with CS reconstructions.