MRMark O. Rikel

Mark O. Rikel

*This is an algorithmically generated author record based on publicly available information.

Mark O. Rikel has a total of 129 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantifying extended RE124 stacking faults in RE123 thin films using x-ray diffraction

    by Kai Walter, Mark Rikel, Martin Peterlechner, Manuela Erbe, Jens Hänisch, Bernhard Holzapfel

    Currently most optimizations of the superconducting properties of RE Ba 2 Cu 3 O 7- δ (REBCO, RE123) are done based on process parameters. Defect-density based methods offer a more direct way for such optimization due to the fact that the superconducting properties of a REBCO conductor emerge from its defect landscape. In this study, an x-ray diffraction (XRD) method will be presented that helps to determine the stacking fault density (SFD) of RE Ba 2 Cu 4 O 8 (RE124) stacking faults reasonably well. It is based on the fact that RE124 stacking faults introduce peak shifts and broadening to (00 l) reflections of RE123. Both quantities vary with the Miller index l , which enables the identification and quantification of these stacking faults. The method is tested using Sm123 thin film samples produced via chemical solution deposition (CSD). A Cu excess is used to facilitate the growth of extended Sm124 stacking faults through a high-temperature oxygenation. The resulting samples show exactly the behavior predicted by the presented theory. The SFDs determined via XRD are then cross-checked by transmission electron microscopy micrographs. It is found that the SFD from peak shift describes the majority of the samples to a sufficient degree of accuracy. Therefore, the presented method is applicable to quantify extended Re124 stacking faults in RE123 thin films.

  • Advances in XRD Characterization of 2G HTS Wire for Low-Temperature Magnet Applications

    by Mark O. Rikel, Vadim A. Amelichev, Anton V. Markelov, Pavel N. Degtyarenko, Aleksandr A. Adamenkov, Anton A. Kamenev

    Industrial 2G HTS wires optimized for low-temperature application are studied using XRD. We aim at understanding the origin of noticeable variation of the lift factor LF = J c (20K, 8T)/ J c (77 K, sf) with the final goal of narrowing down the statistical scatter of the performance in production wires. Two approaches are used - (1) the direct characterization of Y123 defect state through analysis of diffuse scattering effects and (2) quantification of YBCO nanostructure (contents of Y 2 O 3 precipitates, their size, strain state of Y 2 O 3 precipitates and Y123 matrix). Only weak correlations between the parameters extracted from XRD patterns and J c (20K, 8T) have been found. A rather complex strain state of Y123 with out-of-plane tension, anisotropic in-plane compression, and (likely) overall contraction is observed. Further plans are discussed.


  • Introduction to Bulk Firing Techniques

    by Mark O. Rikel, Frank N. Werfel

    HTS conductors for practical applications are made using three oxide compounds REBa2Cu3O7–x (RE-123; RE = Y or rare earth), (Bi,Pb)2Sr2Ca2Cu3O10+y and Bi2Sr2CaCu2O8+δ that have Tc above liquid nitrogen temperature. Except for chemical deposition technologies for thin films and coated conductors, other methods for producing technical superconductor wires use powders as a starting material for filament cores in powder-in-tube processing or as targets for sputtering. In addition, bulk materials directly produced from powders were also technologically exploited in certain key niche areas of power engineering. These include current leads, fault current limiting (FCL) devices and magnetic shielding. The low thermal conductivity of the HTS oxides coupled with the lack of joule heating below Tc essentially reduces the heat leakage during transporting power currents between ambient and liquid helium temperatures when compared with a conventional metallic copper leads or LTS leads (for current transfer from 4.2 K to 1.8 K). These components are usually in the form of an assembly of wires or tapes or large diameter rods or tubes. The bulk current leads were the first commercial application of HTS materials (Bock et al., 1995) and still occupy a small niche for special applications when extremely low thermal losses are required (Takeda et al., 2017). The very low thermal conductivities of bulk Y-123 (close to that of stainless steel) and particularly Bi-2223 (two to five times smaller depending on temperature) and Bi-2212 (an order of magnitude smaller) are the clear reasons for that (Ryan, 2003; Yamada, 1996).

  • Nucleation and mesostrain influence on percolating critical currents of solution derived YBa2Cu3O7 superconducting thin films

    by X. Obradors, F. Martínez-Julián, K. Zalamova, V.R. Vlad, A. Pomar, A. Palau, A. Llordés, H. Chen, M. Coll, S. Ricart, et al.


  • HTS Fault Current Limiters—First Commercial Devices for Distribution Level Grids in Europe

    by J. Bock, M. Bludau, R. Dommerque, A. Hobl, S. Kraemer, M. O. Rikel, S. Elschner

    Nexans SuperConductors GmbH (NSC) has successfully designed, built and tested the first two HTS Fault Current Limiter (FCL) systems on a commercial basis for two different application cases in Europe. Both systems are live in the customer grids since last quarter of 2009: The first one is installed in UK where it acts as a bus bar coupler in a MV grid. The second one is protecting the auxiliary supply of a brown coal power station in Germany. The superconducting components are based on bulk melt cast processed BSCCO-2212 material. NSC masters the full product chain for the new systems starting from raw material powder, via HTS tubes, FCL components and modules to the complete systems. For the second system, NSC has also integrated the ancillary equipment for cooling and has successfully commissioned the system at the customer site. Prior to field installation both systems were intensively tested at the independent and certified test lab IPH in Berlin. The paper gives an overview of both systems, reports on first experiences from field operation and depicts perspectives for the future.


  • Development of All-CSD Processes for Coated Conductors at Nexans: Limitations and Possible Solutions

    by M. O. Rikel, J. Ehrenberg, S. Mahachi, M. Klein, B. Hoppe, J. Schutz, J. Bock

    Nexans experience in developing all CSD processes for coated conductors with the YBCO/CGO/LZO/Ni-5% W RABITS architecture is summarized. The chosen CC architecture has a principal disadvantage that the next layer only clones, but more often deteriorates the out-of-plane texture of the previous layer (in average by ~ 20% for LZO). Depending on the quality of RABITS, this may increase the amount of grain boundaries (GBs) not transparent for the supercurrent close to the percolation limit for the current-breaking path, which explains low and poorly reproducible Jc. Modifying the buffer architecture by introducing CGO seed layer suppresses deterioration of the out-of-plane texture. Another approach, extending the range of acceptable grain misorientations by selective doping YBCO GBs with Ca is shown not possible using the current MOD-TFA process because of decomposition of initial Y123 to disordered Y124 and Y247 during pyrolysis of the second MOD layer. Possible ways of further development are discussed.


  • MOCVD and MOD of YBCO and Buffer Layers on Textured Metal Tapes

    by Oliver Stadel, Ruslan Yu. Muydinov, Günter Brauer, Mark O. Rikel, Jürgen Ehrenberg, Joachim Bock, Gunter Kotzyba, Rainer Nast, Wilfried Goldacker, Sergej V. Samoylenkov, et al.

    Different layer architectures produced by only MOD, only MOCVD and combinations of MOD buffers and MOCVD YBCO are presented. RTR MOCVD-YBCO layers obtained on MOD-CeO2/MOD-LZO/Ni5 at%W tapes demonstrate critical current densities up to 2 MA/cm2 at 77 K. On single LZO (50-100 nm) buffered Ni5 at%W tapes from Nexans Superconductors and on RTR MOCVD buffer layers critical current densities between 0.8 and 1.3 MA/cm are obtained. RTR MOD-LZO layers often show delamination during YBCO deposition. Preannealing treatment before YBCO deposition allows to avoid this. Tapes up to 10 m are produced by combination of MOD-LZO and RTR MOCVD-YBCO.


  • Effect of composition on the melting behaviour of Bi2212-Ag conductors

    by M O Rikel, S Arsac, E Soileux, J Ehrenberg, J Bock, K Marken, H Miao, C-E Bruzek, S Pavard, A Matsumoto, et al.


  • Studies of Precursor Composition Effect on Jc in Bi-2212/Ag Wires and Tapes

    by H. Miao, K. R. Marken, M. Meinesz, B. Czabaj, S. Hong, M. O. Rikel, J. Bock

    Efforts to increase critical current density (Jc) and engineering current density (JE) in round multifilament Bi‐2212/Ag wires have included studies of the effect of precursor composition. Variations in the cation ratios in the precursor have a number of effects on conductor processing and properties, including the melt temperature, the relative sharpness of the melting event, the crystallization behavior including secondary phase formation and growth, and the peak Jc and JE attainable. Multifilamentary wires and dip coated tapes made from four precursors with different cation ratios were studied using an experimental matrix of heat treatments that systematically varied melt temperature, cooling rate, annealing temperature, and annealing time. Average Jc and JE were determined for all samples. In addition two different levels of Ag additions were given to two of the cation ratios, and subjected to the same heat treatment matrix. The results showed a strong dependence of microstructure and Jc on cation ratio and heat treatment parameters, but not obviously on Ag addition in multifilament Bi‐2212/Ag wires. The highest JE of 1580 A/mm2 (Jc of 6140 A/mm2) at 4.2 K, 0 T and JE of 312 A/mm2 (Jc of 1160 A/mm2) at 20 K, 2 T were obtained in 0.81 mm wire with the precursor composition of Bi:Sr:Ca:Cu = 2.17:1.94:0.89:2.00.


  • Reactions between oxides and Ag-sheathed Bi2Sr2CaCu2Oxconductors

    by D E Wesolowski, M O Rikel, J Jiang, S Arsac, E E Hellstrom