Rangel Todorov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rangel Todorov has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Ilia Liondev
Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University of Sofia, 1000 Sofia, Bulgaria
7 shared publications - Ivet Dzhondrova
Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University of Sofia, 1000 Sofia, Bulgaria
7 shared publications - Nikolay Apostolov
Faculty of Dental Medicine, Medical University of Sofia, Sofia, Bulgaria
7 shared publications - Stefan Zlatev
CAD/CAM Center of Dental Medicine at the Research Institute, Medical University-Plovdiv, Plovdiv 4000, Bulgaria
6 shared publications - Bozhidar Yordanov
Med Univ Sofia, Fac Dent Med, Dept Prosthet Dent Med, Sofia, Bulgaria
4 shared publications - Dimitar Kirov
Department of Prosthetic Dental Medicine, Faculty of Dental Medicine, Medical University of Sofia, 1000 Sofia, Bulgaria
4 shared publications
Latest Publications
- Open Access
- 20 August 2026
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 52, 1-7
Comparative Evaluation of Spectrophotometric and Artificial Intelligence-Based Tooth Shade Determination
Aim: The aim of the present study was to evaluate the agreement between spectrophotometric tooth shade determination and an artificial intelligence-based method using standardized digital images of maxillary central incisors. Materials and Methods: A comparative clinical study was conducted on 25 patients aged between 18 and 30 years with intact natural dentition in the anterior maxillary region. A total of 50 teeth were examined, including the maxillary right central incisor 11 and the maxillary left central incisor 21. Tooth shade was determined using SpectroShade Micro II/SpectroShade according to the VITA Classical and VITA 3D-Master shade systems. Standardized digital photographs were obtained using a Canon EOS SL3 camera in manual mode with fixed exposure parameters. A grey card was included in each image for white balance standardization. The images were processed in Adobe Lightroom Classic software and subsequently analyzed using ChatGPT based on the GPT-5.5 Thinking model. Agreement between SpectroShade and ChatGPT was assessed by calculating the percentage of complete agreement and the unweighted Cohen’s kappa coefficient. Results: Complete agreement between SpectroShade and ChatGPT was observed in 32 out of 50 teeth for both shade systems, corresponding to an agreement rate of 64.0%. The Cohen’s kappa value was κ = 0.402 for VITA Classical and κ = 0.494 for VITA 3D-Master, indicating moderate agreement between the two methods. Conclusion: Within the limitations of the present study, the artificial intelligence-based method demonstrated moderate agreement with spectrophotometric shade determination. ChatGPT may be considered a potential auxiliary tool for tooth shade assessment when standardized photographic protocols are applied. However, it should not be regarded as a substitute for spectrophotometric evaluation.
- 20 August 2026
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 52, 1-7
Open AccessComparative Evaluation of Spectrophotometric and Artificial Intelligence-Based Tooth Shade Determination
Aim: The aim of the present study was to evaluate the agreement between spectrophotometric tooth shade determination and an artificial intelligence-based method using standardized digital images of maxillary central incisors. Materials and Methods: A comparative clinical study was conducted on 25 patients aged between 18 and 30 years with intact natural dentition in the anterior maxillary region. A total of 50 teeth were examined, including the maxillary right central incisor 11 and the maxillary left central incisor 21. Tooth shade was determined using SpectroShade Micro II/SpectroShade according to the VITA Classical and VITA 3D-Master shade systems. Standardized digital photographs were obtained using a Canon EOS SL3 camera in manual mode with fixed exposure parameters. A grey card was included in each image for white balance standardization. The images were processed in Adobe Lightroom Classic software and subsequently analyzed using ChatGPT based on the GPT-5.5 Thinking model. Agreement between SpectroShade and ChatGPT was assessed by calculating the percentage of complete agreement and the unweighted Cohen’s kappa coefficient. Results: Complete agreement between SpectroShade and ChatGPT was observed in 32 out of 50 teeth for both shade systems, corresponding to an agreement rate of 64.0%. The Cohen’s kappa value was κ = 0.402 for VITA Classical and κ = 0.494 for VITA 3D-Master, indicating moderate agreement between the two methods. Conclusion: Within the limitations of the present study, the artificial intelligence-based method demonstrated moderate agreement with spectrophotometric shade determination. ChatGPT may be considered a potential auxiliary tool for tooth shade assessment when standardized photographic protocols are applied. However, it should not be regarded as a substitute for spectrophotometric evaluation.
- Open Access
- 20 August 2026
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 52, 1-5
Contralateral shade comparison in anterior teeth
Digital shade determination was used to evaluate shade distribution and contralateral shade matching in the maxillary anterior teeth of 120 patients aged 18–30 years. Teeth 13, 12, 11, 21, 22 and 23 were scanned with 3Shape TRIOS 4 Wireless and classified according to VITA 3D-Master and VITA Classical. Of 720 planned tooth-level observations, 709 were valid; 11 were excluded because of scanning artifacts. The most frequent 3D-Master shades were 1M2 (51.6%), 2M3 (24.7%) and 0M3 (6.6%). The most frequent Classical shades were A1 (45.4%), A2 (30.3%) and A3 (8.6%). Confirmed contralateral matching was higher with VITA 3D-Master than with VITA Classical, reaching 65.0% for teeth 11–21. Complete matching in all three pairs occurred in 26.7% and 5.8% of patients, respectively. These findings show that contralateral teeth can support esthetic planning, but individual digital shade assessment remains necessary for predictable anterior restorations. This supports cautious use of contralateral reference teeth clinically.
- 20 August 2026
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 52, 1-5
Open AccessContralateral shade comparison in anterior teeth
Digital shade determination was used to evaluate shade distribution and contralateral shade matching in the maxillary anterior teeth of 120 patients aged 18–30 years. Teeth 13, 12, 11, 21, 22 and 23 were scanned with 3Shape TRIOS 4 Wireless and classified according to VITA 3D-Master and VITA Classical. Of 720 planned tooth-level observations, 709 were valid; 11 were excluded because of scanning artifacts. The most frequent 3D-Master shades were 1M2 (51.6%), 2M3 (24.7%) and 0M3 (6.6%). The most frequent Classical shades were A1 (45.4%), A2 (30.3%) and A3 (8.6%). Confirmed contralateral matching was higher with VITA 3D-Master than with VITA Classical, reaching 65.0% for teeth 11–21. Complete matching in all three pairs occurred in 26.7% and 5.8% of patients, respectively. These findings show that contralateral teeth can support esthetic planning, but individual digital shade assessment remains necessary for predictable anterior restorations. This supports cautious use of contralateral reference teeth clinically.
- Open Access
- 22 July 2026
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 52, 1-6
Tooth-Implant-Supported Mandibular Overdenture with Locator® Attachments. Case Report
Tooth-implant-supported removable dentures represent a controversial treatment modality because of the biomechanical differences between natural teeth and osseointegrated implants. This case report describes the prosthetic rehabilitation of an 85-year-old patient with Kennedy Class I mandibular edentulism using a tooth-implant-supported mandibular overdenture retained by two Locator® attachments over dental implants and one ball attachment over a natural mandibular canine. Two dental implants were placed in the anterior mandible and restored with Locator® attachments, while the remaining mandibular right canine was prepared and restored with a custom cement-retained ball attachment. A mandibular acrylic overdenture was fabricated and retained using both implant- and tooth-supported attachments. Clinical and radiographic follow-up evaluations performed at 12 and 24 months demonstrated stable peri-implant and periodontal conditions without detectable bone loss or signs of inflammation. The patient reported high satisfaction regarding denture retention, stability, function, and esthetics, and no mechanical complications were observed during the follow-up period. Within the limitations of this case report, the combined use of Locator® and ball attachments for a tooth-implant-supported mandibular overdenture demonstrated favorable short-term clinical outcomes and high patient satisfaction. Nevertheless, further long-term clinical studies are required to validate the predictability and long-term success of this treatment approach.
- 22 July 2026
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 52, 1-6
Open AccessTooth-Implant-Supported Mandibular Overdenture with Locator® Attachments. Case Report
Tooth-implant-supported removable dentures represent a controversial treatment modality because of the biomechanical differences between natural teeth and osseointegrated implants. This case report describes the prosthetic rehabilitation of an 85-year-old patient with Kennedy Class I mandibular edentulism using a tooth-implant-supported mandibular overdenture retained by two Locator® attachments over dental implants and one ball attachment over a natural mandibular canine. Two dental implants were placed in the anterior mandible and restored with Locator® attachments, while the remaining mandibular right canine was prepared and restored with a custom cement-retained ball attachment. A mandibular acrylic overdenture was fabricated and retained using both implant- and tooth-supported attachments. Clinical and radiographic follow-up evaluations performed at 12 and 24 months demonstrated stable peri-implant and periodontal conditions without detectable bone loss or signs of inflammation. The patient reported high satisfaction regarding denture retention, stability, function, and esthetics, and no mechanical complications were observed during the follow-up period. Within the limitations of this case report, the combined use of Locator® and ball attachments for a tooth-implant-supported mandibular overdenture demonstrated favorable short-term clinical outcomes and high patient satisfaction. Nevertheless, further long-term clinical studies are required to validate the predictability and long-term success of this treatment approach.
- Open Access
- 9 June 2026
- Published by Pensoft Publishers in Pharmacia
- Vol. 73
Dehydration and rehydration effects on natural tooth color
The aim of this study was to evaluate time-dependent changes in the color characteristics of intact maxillary anterior teeth during controlled dehydration and subsequent natural rehydration using spectrophotometric analysis. Thirty systemically healthy subjects aged 18–30 years with intact maxillary anterior teeth were included. Tooth color was measured using a spectrophotometer at baseline, during a 30-min dehydration phase, and during a 30-min passive rehydration phase. Color differences ( ΔE ) relative to baseline were calculated, and changes in L *, a *, and b * coordinates in the CIELAB system were analyzed. Dehydration resulted in a progressive increase in ΔE , reaching a maximum of 3.00 ± 1.62 at 30 min, accompanied by increased lightness and reduced chromaticity. During rehydration, ΔE values decreased steadily, approaching baseline levels by 60 min. The results demonstrate that tooth dehydration induces perceptible but largely reversible color changes, highlighting the importance of hydration control during clinical shade selection.
- 9 June 2026
- Published by Pensoft Publishers in Pharmacia
- Vol. 73
Open AccessDehydration and rehydration effects on natural tooth color
The aim of this study was to evaluate time-dependent changes in the color characteristics of intact maxillary anterior teeth during controlled dehydration and subsequent natural rehydration using spectrophotometric analysis. Thirty systemically healthy subjects aged 18–30 years with intact maxillary anterior teeth were included. Tooth color was measured using a spectrophotometer at baseline, during a 30-min dehydration phase, and during a 30-min passive rehydration phase. Color differences ( ΔE ) relative to baseline were calculated, and changes in L *, a *, and b * coordinates in the CIELAB system were analyzed. Dehydration resulted in a progressive increase in ΔE , reaching a maximum of 3.00 ± 1.62 at 30 min, accompanied by increased lightness and reduced chromaticity. During rehydration, ΔE values decreased steadily, approaching baseline levels by 60 min. The results demonstrate that tooth dehydration induces perceptible but largely reversible color changes, highlighting the importance of hydration control during clinical shade selection.
- Open Access
- 23 February 2026
- Published by Pensoft Publishers in Pharmacia
- Vol. 73, 1-7
Evaluation of tooth shade determination using spectrophotometry and intraoral scanning
This study aimed to assess the agreement between spectrophotometric and intraoral scanner-based tooth shade determination using the VITA Classical and VITA 3D-Master shade systems. Tooth shade was determined consecutively using a spectrophotometer and an intraoral scanner in 120 healthy adults. Measurements were performed on the vestibular surfaces of 709 maxillary anterior teeth. Shade outcomes were recorded according to the VITA Classical and VITA 3D-Master systems. Inter-method agreement was evaluated using percentage agreement, Cohen’s kappa coefficients, and Krippendorff’s α. Full categorical agreement was observed in 54.9% of measurements for the VITA 3D-Master system and in 62.3% for the VITA Classical system. Unweighted Cohen’s kappa indicated fair-to-moderate agreement. Weighted kappa for the VITA 3D-Master system demonstrated substantial agreement, indicating that most discrepancies occurred between adjacent shade categories. Intraoral scanner-based digital shade determination showed clinically acceptable agreement with spectrophotometric assessment. Most disagreements involved adjacent shade categories, supporting its use as a complementary method within digital workflows.
- 23 February 2026
- Published by Pensoft Publishers in Pharmacia
- Vol. 73, 1-7
Open AccessEvaluation of tooth shade determination using spectrophotometry and intraoral scanning
This study aimed to assess the agreement between spectrophotometric and intraoral scanner-based tooth shade determination using the VITA Classical and VITA 3D-Master shade systems. Tooth shade was determined consecutively using a spectrophotometer and an intraoral scanner in 120 healthy adults. Measurements were performed on the vestibular surfaces of 709 maxillary anterior teeth. Shade outcomes were recorded according to the VITA Classical and VITA 3D-Master systems. Inter-method agreement was evaluated using percentage agreement, Cohen’s kappa coefficients, and Krippendorff’s α. Full categorical agreement was observed in 54.9% of measurements for the VITA 3D-Master system and in 62.3% for the VITA Classical system. Unweighted Cohen’s kappa indicated fair-to-moderate agreement. Weighted kappa for the VITA 3D-Master system demonstrated substantial agreement, indicating that most discrepancies occurred between adjacent shade categories. Intraoral scanner-based digital shade determination showed clinically acceptable agreement with spectrophotometric assessment. Most disagreements involved adjacent shade categories, supporting its use as a complementary method within digital workflows.
- Open Access
- 9 December 2025
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 51, 1-4
Spectrophotometric analysis of color stability of mandibular anterior teeth after placement of a fixed retainer
Introduction: The growing social importance of dental aesthetics has led to increased demand for orthodontic treatments that deliver not only functional but also highly aesthetic outcomes. Following orthodontic therapy, fixed retention appliances are commonly used; however, their potential impact on tooth color remains insufficiently investigated. Aim: To evaluate color changes in mandibular anterior teeth after the placement of a fixed retainer using spectrophotometric analysis. Materials and methods: The study included 20 patients (aged 18–35 years) who had completed orthodontic treatment with fixed appliances. Color measurements were taken using the Vita EasyShade V spectrophotometer. A triple-stranded stainless steel orthodontic wire (American Orthodontics) was bonded to the lingual surfaces of teeth 33–43 using a light-cured adhesive (GC Ortho Connect Flow). Immediately after retainer placement, color measurements were repeated, and the changes were quantitatively evaluated using ΔE values calculated according to the CIELAB color coordinates. Results: The mean ΔE values were 0.75 ± 0.2 for central incisors, 0.8 ± 0.3 for lateral incisors, and 1.2 ± 0.4 for canines. All values remained below the clinical perceptibility threshold (ΔE < 1.5), indicating no significant aesthetic alteration. Conclusion: The findings confirm that the evaluated retention appliance does not cause clinically perceptible changes in tooth color and can be considered suitable for use in aesthetically sensitive areas.
- 9 December 2025
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 51, 1-4
Open AccessSpectrophotometric analysis of color stability of mandibular anterior teeth after placement of a fixed retainer
Introduction: The growing social importance of dental aesthetics has led to increased demand for orthodontic treatments that deliver not only functional but also highly aesthetic outcomes. Following orthodontic therapy, fixed retention appliances are commonly used; however, their potential impact on tooth color remains insufficiently investigated. Aim: To evaluate color changes in mandibular anterior teeth after the placement of a fixed retainer using spectrophotometric analysis. Materials and methods: The study included 20 patients (aged 18–35 years) who had completed orthodontic treatment with fixed appliances. Color measurements were taken using the Vita EasyShade V spectrophotometer. A triple-stranded stainless steel orthodontic wire (American Orthodontics) was bonded to the lingual surfaces of teeth 33–43 using a light-cured adhesive (GC Ortho Connect Flow). Immediately after retainer placement, color measurements were repeated, and the changes were quantitatively evaluated using ΔE values calculated according to the CIELAB color coordinates. Results: The mean ΔE values were 0.75 ± 0.2 for central incisors, 0.8 ± 0.3 for lateral incisors, and 1.2 ± 0.4 for canines. All values remained below the clinical perceptibility threshold (ΔE < 1.5), indicating no significant aesthetic alteration. Conclusion: The findings confirm that the evaluated retention appliance does not cause clinically perceptible changes in tooth color and can be considered suitable for use in aesthetically sensitive areas.
- 8 July 2025
- Published by Peytchinski Publishing Ltd. in Journal of IMAB – Annual Proceeding (Scientific Papers)
- Vol. 31 (3) , 6322-6326
COLOR CHARACTERISTICS OF THE ANTERIOR TEETH IN DENTAL STUDENTS
Introduction: Tooth color is a key determinant of dental aesthetics and critically influences patient satisfaction. Traditional shade matching is subjective and inconsistent, while spectrophotometry offers standardized, reproducible, and objective measurements. Defining the natural color profiles of anterior teeth in young adults is essential for predictable and high-quality esthetic restorations. The purpose of this study is to analyze the color characteristics of the maxillary central incisors, lateral incisors, and canines in a population of young adults aged 18–21 using a spectrophotometer (Spectroshade; MHT Optic Research). Materials and Methods: Color measurements were conducted on 153 dental students aged 18–21 years using the SpectroShade Micro spectrophotometer. The teeth examined were maxillary central (11, 21), lateral incisors (12, 22) and canines (13, 23). VITA Classical shades were matched and subsequently converted to CIELAB values (L*, a*, b*). Statistical analysis included mean, SD, and one-way ANOVA (α = 0.05). Results: The central incisors had the highest L* (lightness) values, indicating greater brightness. Canines presented significantly higher b* values, reflecting more pronounced yellowness. Statistically significant differences (p < 0.05) were observed among the tooth groups. Conclusion: Color parameters of anterior teeth vary significantly between tooth types in young adults. These findings are valuable for aesthetic restorative procedures and provide a reference for shade selection in this age group.
- 8 July 2025
- Published by Peytchinski Publishing Ltd. in Journal of IMAB – Annual Proceeding (Scientific Papers)
- Vol. 31 (3) , 6322-6326
COLOR CHARACTERISTICS OF THE ANTERIOR TEETH IN DENTAL STUDENTS
Introduction: Tooth color is a key determinant of dental aesthetics and critically influences patient satisfaction. Traditional shade matching is subjective and inconsistent, while spectrophotometry offers standardized, reproducible, and objective measurements. Defining the natural color profiles of anterior teeth in young adults is essential for predictable and high-quality esthetic restorations. The purpose of this study is to analyze the color characteristics of the maxillary central incisors, lateral incisors, and canines in a population of young adults aged 18–21 using a spectrophotometer (Spectroshade; MHT Optic Research). Materials and Methods: Color measurements were conducted on 153 dental students aged 18–21 years using the SpectroShade Micro spectrophotometer. The teeth examined were maxillary central (11, 21), lateral incisors (12, 22) and canines (13, 23). VITA Classical shades were matched and subsequently converted to CIELAB values (L*, a*, b*). Statistical analysis included mean, SD, and one-way ANOVA (α = 0.05). Results: The central incisors had the highest L* (lightness) values, indicating greater brightness. Canines presented significantly higher b* values, reflecting more pronounced yellowness. Statistically significant differences (p < 0.05) were observed among the tooth groups. Conclusion: Color parameters of anterior teeth vary significantly between tooth types in young adults. These findings are valuable for aesthetic restorative procedures and provide a reference for shade selection in this age group.
- 24 July 2024
- Published by Peytchinski Publishing Ltd. in Journal of IMAB – Annual Proceeding (Scientific Papers)
- Vol. 30 (3) , 5658-5663
EVALUATION OF CANDIDA SPP. ADHERENCE TO 3D-PRINTED AND HEAT-CURED PMMA RESIN DENTURES
Introduction: Despite the progress of additive manufacturing, there are different opinions regarding microbial adhesion on the surface of 3D printed dentures and the biocompatiability of the materials. The purpose of this in-vivo study was to determine the presence of Candida species in the saliva, oral mucosa and on dentures of patients wearing heat-cured polymethylmethacrylate (PMMA) and 3D-printed prosthetic appliances after a three-month period of observation. Materials and methods: The clinical study included 40 edentulous patients, divided into two groups - first group (A) –wearing conventional dentures and second group (B) – wearing 3D printed dentures. It was used chrom agar Candida (Bio Merieux) for identification and quantity assessment of the presence of Candida spp. and spectrophotometric analysis using VITEK MS (Bio Merieux). Results: After three months of wearing the dentures, Candida spp was not isolated in the saliva in 60% of patients in group A and 70% of group B, with no statistically significant difference between the results before the treatment and after the third month. In the third month, Candida spp was isolated from the oral mucosa of 20% of group A and in group B – 10%, with no significant difference between the groups (p<0.05). No Candida spp was isolated from 90% of denture surfaces in both groups. Conclusion: The adhesion of Candida spp. to 3D printed dentures is not higher than conventional dentures made from heat-curing resin. Also, there is no difference between the amount of Candida spp. in the saliva, oral mucosa and denture surfaces.
- 24 July 2024
- Published by Peytchinski Publishing Ltd. in Journal of IMAB – Annual Proceeding (Scientific Papers)
- Vol. 30 (3) , 5658-5663
EVALUATION OF CANDIDA SPP. ADHERENCE TO 3D-PRINTED AND HEAT-CURED PMMA RESIN DENTURES
Introduction: Despite the progress of additive manufacturing, there are different opinions regarding microbial adhesion on the surface of 3D printed dentures and the biocompatiability of the materials. The purpose of this in-vivo study was to determine the presence of Candida species in the saliva, oral mucosa and on dentures of patients wearing heat-cured polymethylmethacrylate (PMMA) and 3D-printed prosthetic appliances after a three-month period of observation. Materials and methods: The clinical study included 40 edentulous patients, divided into two groups - first group (A) –wearing conventional dentures and second group (B) – wearing 3D printed dentures. It was used chrom agar Candida (Bio Merieux) for identification and quantity assessment of the presence of Candida spp. and spectrophotometric analysis using VITEK MS (Bio Merieux). Results: After three months of wearing the dentures, Candida spp was not isolated in the saliva in 60% of patients in group A and 70% of group B, with no statistically significant difference between the results before the treatment and after the third month. In the third month, Candida spp was isolated from the oral mucosa of 20% of group A and in group B – 10%, with no significant difference between the groups (p<0.05). No Candida spp was isolated from 90% of denture surfaces in both groups. Conclusion: The adhesion of Candida spp. to 3D printed dentures is not higher than conventional dentures made from heat-curing resin. Also, there is no difference between the amount of Candida spp. in the saliva, oral mucosa and denture surfaces.
- Open Access
- 7 January 2023
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 49, 14-19
Comparison of the color characteristics of central incisors among dental students
Introduction: Shade determination in dental medicine is a key factor in achieving optimal aesthetic results, particularly in the restoration of central incisors, which often poses challenges in clinical practice. The use of modern devices, such as the Vita EasyShade V spectrophotometer developed by the German company Vita Zahnfabrik, significantly enhances the quality of dental work. This device enables more precise and objective shade determination, leading to better results and increased satisfaction for both patients and dentists. Aim: The aim of this study is to compare the color characteristics of teeth in two groups of subjects
- 7 January 2023
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 49, 14-19
Open AccessComparison of the color characteristics of central incisors among dental students
Introduction: Shade determination in dental medicine is a key factor in achieving optimal aesthetic results, particularly in the restoration of central incisors, which often poses challenges in clinical practice. The use of modern devices, such as the Vita EasyShade V spectrophotometer developed by the German company Vita Zahnfabrik, significantly enhances the quality of dental work. This device enables more precise and objective shade determination, leading to better results and increased satisfaction for both patients and dentists. Aim: The aim of this study is to compare the color characteristics of teeth in two groups of subjects
- Open Access
- 7 January 2023
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 49, 7-13
Mechanical Properties of Nylon Denture Base Materials: A Literature Review
A wide range of thermoplastic materials for the fabrication of removable partial dentures (RPDs) is available for use in the everyday dental practice. The success of the prosthetic treatment depends on the properties of the selected denture base material. Thermoplastic polyamides, also known as nylons, are one of the four major groups of flexible materials used for treating partially edentulous patients with removable partial dentures.The aim of the current review was to evaluate and compare the advantages and disadvantages between the different types of thermoplastic materials available and conventional polymethyl-methacrylate (PMMA) dentures in regards to their mechanical properties. A literature review was conducted using PubMed, Web of Science, Google Scholar, MDPI Open Access Journals and Wiley Online Library. There was no restriction on the date of publishing and language of publications. The keywords used for conducting the search were combinations of the following: “nylon dentures”, “flexible dentures”, “polyamide”, “mechanical properties” and “PMMA”.Currently flexible polyamide is considered an alternative to the conventional acrylic resins due to its aesthetic and functional characteristics and physicochemical qualities. These materials can be used in denture fabrication in some cases such as severe undercuts, repeated fracture of conventional PMMA dentures, in aesthetic-concerned patients, those who have allergy to other denture base materials, and in patients where a thinner, more easily adaptable denture base material has to be used.Although polyamides offer some clear advantages over the conventional PMMA resins, the question about their longevity and overall mechanical properties remains a topic of discussion.
- 7 January 2023
- Published by Pensoft Publishers in Problems of Dental Medicine
- Vol. 49, 7-13
Open AccessMechanical Properties of Nylon Denture Base Materials: A Literature Review
A wide range of thermoplastic materials for the fabrication of removable partial dentures (RPDs) is available for use in the everyday dental practice. The success of the prosthetic treatment depends on the properties of the selected denture base material. Thermoplastic polyamides, also known as nylons, are one of the four major groups of flexible materials used for treating partially edentulous patients with removable partial dentures.The aim of the current review was to evaluate and compare the advantages and disadvantages between the different types of thermoplastic materials available and conventional polymethyl-methacrylate (PMMA) dentures in regards to their mechanical properties. A literature review was conducted using PubMed, Web of Science, Google Scholar, MDPI Open Access Journals and Wiley Online Library. There was no restriction on the date of publishing and language of publications. The keywords used for conducting the search were combinations of the following: “nylon dentures”, “flexible dentures”, “polyamide”, “mechanical properties” and “PMMA”.Currently flexible polyamide is considered an alternative to the conventional acrylic resins due to its aesthetic and functional characteristics and physicochemical qualities. These materials can be used in denture fabrication in some cases such as severe undercuts, repeated fracture of conventional PMMA dentures, in aesthetic-concerned patients, those who have allergy to other denture base materials, and in patients where a thinner, more easily adaptable denture base material has to be used.Although polyamides offer some clear advantages over the conventional PMMA resins, the question about their longevity and overall mechanical properties remains a topic of discussion.