NANikolay Apostolov

Nikolay Apostolov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nikolay Apostolov has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Evaluation of Spectrophotometric and Artificial Intelligence-Based Tooth Shade Determination

    by Ilia Liondev, Nikolay Apostolov, Rangel Todorov

    Aim: The aim of the present study was to evaluate the agreement between spectrophotometric tooth shade determination and an artificial intelligence-based method using standardized digital images of maxillary central incisors. Materials and Methods: A comparative clinical study was conducted on 25 patients aged between 18 and 30 years with intact natural dentition in the anterior maxillary region. A total of 50 teeth were examined, including the maxillary right central incisor 11 and the maxillary left central incisor 21. Tooth shade was determined using SpectroShade Micro II/SpectroShade according to the VITA Classical and VITA 3D-Master shade systems. Standardized digital photographs were obtained using a Canon EOS SL3 camera in manual mode with fixed exposure parameters. A grey card was included in each image for white balance standardization. The images were processed in Adobe Lightroom Classic software and subsequently analyzed using ChatGPT based on the GPT-5.5 Thinking model. Agreement between SpectroShade and ChatGPT was assessed by calculating the percentage of complete agreement and the unweighted Cohen’s kappa coefficient. Results: Complete agreement between SpectroShade and ChatGPT was observed in 32 out of 50 teeth for both shade systems, corresponding to an agreement rate of 64.0%. The Cohen’s kappa value was κ = 0.402 for VITA Classical and κ = 0.494 for VITA 3D-Master, indicating moderate agreement between the two methods. Conclusion: Within the limitations of the present study, the artificial intelligence-based method demonstrated moderate agreement with spectrophotometric shade determination. ChatGPT may be considered a potential auxiliary tool for tooth shade assessment when standardized photographic protocols are applied. However, it should not be regarded as a substitute for spectrophotometric evaluation.

  • Open Access

    Dehydration and rehydration effects on natural tooth color

    by Ilia Liondev, Ivet Dzhondrova, Dimitar Kirov, Todor Uzunov, Nikolay Apostolov, Aleksandar Naydenov, Rangel Todorov

    The aim of this study was to evaluate time-dependent changes in the color characteristics of intact maxillary anterior teeth during controlled dehydration and subsequent natural rehydration using spectrophotometric analysis. Thirty systemically healthy subjects aged 18–30 years with intact maxillary anterior teeth were included. Tooth color was measured using a spectrophotometer at baseline, during a 30-min dehydration phase, and during a 30-min passive rehydration phase. Color differences ( ΔE ) relative to baseline were calculated, and changes in L *, a *, and b * coordinates in the CIELAB system were analyzed. Dehydration resulted in a progressive increase in ΔE , reaching a maximum of 3.00 ± 1.62 at 30 min, accompanied by increased lightness and reduced chromaticity. During rehydration, ΔE values decreased steadily, approaching baseline levels by 60 min. The results demonstrate that tooth dehydration induces perceptible but largely reversible color changes, highlighting the importance of hydration control during clinical shade selection.

  • Open Access

    Effect of Printing Orientation on the Dimensional Accuracy of 3D-Printed Denture Base

    by Ivet Dzhondrova, Ilia Liondev, Todor Bogdanov, Todor Uzunov, Nickolay Apostolov, Rangel Todorov, Dimitar Kirov

    Additive manufacturing is now an integral part of digital prosthodontic workflows, and although stereolithography (SLA) is widely used for denture base fabrication, the dimensional accuracy of printed dentures remains highly dependent on manufacturing parameters, particularly build orientation. This study evaluated the influence of build orientation on the trueness and precision of SLA-printed maxillary and mandibular denture bases. Thirty complete denture bases were fabricated using SLA and divided into three groups according to build orientation: 0°, 45°, and 90° (n = 10). The intaglio surfaces of the printed dentures were scanned and compared with their corresponding digital reference models using three-dimensional inspection software. Trueness was quantified using root mean square error (RMSE) and directional deviations, while precision was assessed based on the variability of RMSE values within each group. Statistical analysis was performed using one-way ANOVA and Tukey’s post hoc test (p ≤ 0.05). Build orientation significantly affected the trueness of maxillary denture bases, with dentures printed at 90° demonstrating the lowest RMSE values. No statistically significant differences in trueness were observed among build orientations for mandibular denture bases. Precision was not influenced by build orientation for maxillary dentures, whereas mandibular dentures printed at 90° exhibited significantly greater variability compared with 0° and 45°. Build orientation is a critical factor influencing the dimensional accuracy of SLA-printed denture bases in an arch-dependent manner. Optimizing build orientation may enhance both accuracy and reproducibility, thereby improving the predictability and clinical reliability of additively manufactured denture bases.


  • Open Access

    Evaluation of tooth shade determination using spectrophotometry and intraoral scanning

    by Ilia Liondev, Ivet Dzhondrova, Dimitar Kirov, Todor Uzunov, Nikolay Apostolov, Rangel Todorov

    This study aimed to assess the agreement between spectrophotometric and intraoral scanner-based tooth shade determination using the VITA Classical and VITA 3D-Master shade systems. Tooth shade was determined consecutively using a spectrophotometer and an intraoral scanner in 120 healthy adults. Measurements were performed on the vestibular surfaces of 709 maxillary anterior teeth. Shade outcomes were recorded according to the VITA Classical and VITA 3D-Master systems. Inter-method agreement was evaluated using percentage agreement, Cohen’s kappa coefficients, and Krippendorff’s α. Full categorical agreement was observed in 54.9% of measurements for the VITA 3D-Master system and in 62.3% for the VITA Classical system. Unweighted Cohen’s kappa indicated fair-to-moderate agreement. Weighted kappa for the VITA 3D-Master system demonstrated substantial agreement, indicating that most discrepancies occurred between adjacent shade categories. Intraoral scanner-based digital shade determination showed clinically acceptable agreement with spectrophotometric assessment. Most disagreements involved adjacent shade categories, supporting its use as a complementary method within digital workflows.

  • Open Access

    The Influence of Different Cleaning Methods on the Surface Roughness of “ThermoSens” Denture Base Material

    by Rumen Radev, Nikolay Apostolov, Elka Radeva, Mariana Yankova

    The increased use of flexible dentures in the daily dental practice requires additional research regarding how different disinfection protocols affect the dentures surface characteristics. The aim of this study was to evaluate how different cleaning techniques under varying conditions affect the surface roughness (Ra) of “ThermoSens” denture base material. Forty flexible denture specimens with dimensions ø 10 mm were fabricated. They were divided into ten groups (T1-T10) depending on which disinfection method was used. All the specimens were immersed in artificial saliva over the course of 30 days and were cleaned using accessible products (soap, toothpaste, Protefix and Corega tablets). Each test body was then analyzed in four different surface areas using atomic force microscopy (AFM), the results were statistically prepared using IBM SPSS Statistics 26, Excel 2015 and EdrawMax 7. The control group (T1) showed the lowest Ra with average value of 17.4 nm. The use of cleaning tablets Protefix daily (T5) yielded mean values of 46.8 nm, which is more than double than that of the control group. The highest roughness was observed when using a soft brush and toothpaste daily (T8), five times higher (mean 100.6 nm) than that of the control group. The surface roughness of flexible denture base material “ThermoSens” significantly changes depending on the different cleaning protocol used.

  • SHEAR BOND STRENGTH OF LITHIUM DISILICATE AND HYBRID CERAMIC WITH THREE TYPES OF LUTING CEMENT (A PILOT STUDY)

    by Mariana Yankova, Rumen Radev, Todor Uzunov, Nikolay Apostolov, Elka Radeva

    The present pilot study aimed to determine the bond strength between dentin and two types of ceramics cemented using three types of luting agents. The purpose of this pilot study was to determine the bond strength between dentin and two types of ceramics cemented using three types of luting agents. Materials and Methods: Seventy-two dentin discs were prepared from extracted teeth with intact dental crowns. Ceramic cylinders of two types, lithium disilicate (IPS emax CAD) and hybrid Ceramic (Vita Enamic), were cut and sintered to dimensions of 6/6 mm. Test specimens (dentin – cement – ceramic) were distributed into six groups (n = 12), depending on the ceramic material used and the cement used for adhesive fixation (eCEMENT, Variolink Esthetic DC, Panavia V5). They were subjected to shear bond strength testing. The results were statistically analyzed using IBM SPSS Statistics 26 with a significance level of 0.05. Results: In Vita Enamic, the highest shear bond strength was observed with Panavia V5 cement (18.87±0.89 MPa), followed by Variolink Esthetic DC (14.03±4.45 MPa) and e-CEMENT (11.40±5.19 MPa) (p < 0.05). In IPS emax CAD, the best bond was again with Panavia V5 cement (17.53±3.39 MPa), followed by Variolink Esthetic DC (17.30±4.49 MPa) and eCEMENT (14.33±5.27 MPa), however without statistical significance (p > 0.05). Conclusions: Within the limitation of the presented study, the composite cement Panavia V5 demonstrates better adhesive properties than the other two types of cement.

  • EFFECT OF DIFFERENT CLEANING PROTOCOLS ON THE HARDNESS OF FLEXIBLE DENTURE BASE MATERIAL "THERMOSENS”

    by Rumen Radev, Nikolay Apostolov, Elka Radeva

    Introduction. The growing use of flexible dentures in everyday dental practice calls for further studies on how various disinfection methods influence their mechanical properties, particularly their hardness. Purpose. The aim of the study was to evaluate how different cleaning techniques under varying conditions affect the hardness (HVN) of the "ThermoSens" denture base material. Materials and Methods. Forty flexible denture samples, measuring 10 mm in width and 3 mm in height, were made and grouped into ten sets (T1-T10) based on the disinfection method applied. For 30 days, all samples were submerged in artificial saliva and cleaned with common products (soap, toothpaste, Protefix, and Corega tablets). Each sample was then evaluated in five surface areas using the Vickers hardness test, with the data statistically analyzed using IBM SPSS Statistics 26, Excel 2015, and EdrawMax 7. Results. No statistically significant difference was found between the individual groups using different disinfection methods and protocols compared to the control group. Only in group 2, daily cleaning with Corega tablets (9.3 HVN) resulted in a statistically significant increase in hardness compared to the control group.When comparing experimental group 2 with the other groups, a statistically significant difference was found with all groups except group 3 (9.0 HVN) and group 4 (9.1 HVN). Groups 2, 3, and 4 exhibited the highest hardness. Conclusion. The use of different conventional cleaning methods does not alter the hardness of the flexible ThermoSens denture base material.


  • SURFACE COLONIZATION OF CANDIDA SPP. IN CONVENTIONAL AND DOUBLE-LAYER COMPLETE DENTURES - A PILOT STUDY

    by Mariana Yankova, Bozhidar Yordanov, Nickolay Apostolov, Stefan Zlatev, Mariana Dimova- Gabrovska

    Background: The scientific interest in dominant Candida species colonizing the surface of conventional and double-layer dentures (D-LCDs) is still topical. Numerous studies are comparing fungal colonization in both types of removable dentures. Aim: Performing a comparative analysis of the colonization of Candida spp. on the dentures surfaces of the conventional (CCDs) and the double-layer dentures (soft-lined) complete dentures (D-LCDs) over six months, placing them under the same intraoral in vivo conditions. Methods: For isolating Candida spp., specimens were obtained from inner denture surfaces using two sterile swabs, one for the upper complete denture (n=28) and one for the lower complete denture (n=28). The culture-based Candida detection method with CHROM agar was used to identify Candida species. Results: In the third month after dentures delivery C. Albicans is the predominant Candida spp. found on both types of complete dentures surface and isolated in 46 % of the patients with conventional complete dentures and 43 % with double-layer dentures (p>0.05). In the sixth month of the finished prosthetic treatment, combinations of C. Albicans and non-albicans Candida, predominantly C. Tropicalis, C. Glabrata and C. Parapsilosis, were found in 43 % of D-LCDs and 45 % of CCDs (p>0.05). Conclusion: There was no difference in colonization based on the different materials used for denture fabrication. However, there is a significant proportional change for all studied Candida spp. over the period (3-6 months after delivery), irrespective of the denture material used.


  • COLONIZATION OF CANDIDA SPP. IN PATIENTS TREATED WITH PARTIAL DENTURES "THERMOSENS"

    by Rumen Radev, Mariana Yankova, Elka Radeva, Nikolay Apostolov

    Introduction. One of the commonly encountered pathologies in the oral cavity when using removable dentures is denture stomatitis, attributed to Candida spp. colonization on the denture surface. Aim. Determination of the type and quantity of Candida spp. on the mucosal and denture surfaces in patients treated with "ThermoSens" partial dentures before and after treatment. Materials and Methods. Thirty patients were prosthetically treated and divided into 2 groups. In the first group (n=20), treatment was performed with "ThermoSens" partial dentures, while in the second (control) group, patients were treated with conventional dentures (n=10). Swabs were taken from the mucosal and denture surfaces. The samples were tested for quantitative and qualitative differentiation of Candida spp. before prosthetic treatment, at the first and third month after prosthetic treatment. The data was statistically processed using SPSS Statistics 26. Results. No statistically significant difference was observed regarding the quantitative accumulation of Candida spp. on the denture and mucosal surfaces between the two groups of patients (p>5%), measured at 1 month and 3 months after prosthetic treatment. It was found that the predominant Candida spp. in both groups of patients was Candida albicans. Conclusion. Although no statistically significant difference was observed in the two test groups regarding the number of colonies of Candida spp., the main group showed a tendency for a more significant increase in their number (up to 105 CFU/ml) on the denture surfaces at the third month after prosthetic treatment, which may be a presumption for the development of denture stomatitis.


  • Open Access

    Clinical Approach in Prosthetic Treatment With 3D‐Printed Implant‐Retained Removable Denture: DENTCA System

    by Aleksandar Naydenov, Nikolay Apostolov, Rumen Radev

    The aim of this study is to present a method that optimizes clinical and laboratory workflow in the fabrication of implant‐supported removable dentures by combining conventional and digital protocols. A 73‐year‐old patient came to our clinic for treatment of a completely edentulous lower jaw. Two Neodent Helix GM implants were placed in the canine regions and a removable denture with Locator GM Novaloc retention elements was fabricated. The DENTCA system was used for impressions, border molding, and to determine both occlusovertical dimension (OVD) and reproducible, physiological position of lower jaw (RPPLJ) in a single clinical visit. In result, we have fabricated a removable denture with implant retention in just two appointments. We can conclude that DENTCA system is a reliable method that allows fabrication of implant‐retained removable denture in two clinical visits. The registration of the prosthetic field boundaries, OVD and RPPLJ, combined with CAD technologies, represents a contemporary and accurate method. It takes less time, and expenses are reduced both for the dentist and the patient.