Eric Sean Davis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eric Sean Davis has a total of 89 co-authors. Here are the top co-authors by number of shared publications:
- Cristian Pantea
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
14 shared publications Cristian Pantea
9 shared publications- John Greenhall
Los Alamos National Laboratory
7 shared publications - Dipen N. Sinha
Los Alamos National Laboratory
6 shared publications Dipen N. Sinha
Acoustics and Sensors Team, Material Physics and Applications (MPA-11), Los Alamos National Laboratory, NM 87545, USA
5 shared publications- Vamshi Krishna Chillara
MPA-11,Los Alamos National Laboratory,Los Alamos,NM,USA
4 shared publications
Latest Publications
- Open Access
- 2 October 2026
- Published by Elsevier in Composites Part B: Engineering
- Vol. 329
Multidisciplinary investigation of the stability and functional performance of sustainable advanced coating
- 2 October 2026
- Published by Elsevier in Composites Part B: Engineering
- Vol. 329
Open AccessMultidisciplinary investigation of the stability and functional performance of sustainable advanced coating
- Open Access
- 8 September 2026
- Published by Office of Scientific and Technical Information (OSTI)
Real Time, In-line Monitoring of Hanford Tank Wastes
- 8 September 2026
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessReal Time, In-line Monitoring of Hanford Tank Wastes
- Open Access
- 5 September 2026
- Published by Elsevier in SSRN Electronic Journal
Enabling Additive Manufacturing of Reactors for Highly Sensitive Electrochemical Systems
Additive manufacturing enables rapid fabrication of customized electrochemical reactors; however, residual species from photopolymer resins can leach into electrolytes and interfere with sensitive electrochemical measurements. Here, we evaluate two commercial stereolithography resins and develop an enhanced post-processing strategy to minimize resin-derived contamination. Platinum electrodes exposed to two different resins processed according to manufacturer recommendations exhibited electrochemically active surface area losses of 45% and 10%, respectively, after 160 CV cycles. An optimized protocol combining solvent extraction with additional UV and thermal curing reduced these losses to 15% and 4.5%, respectively. Importantly, the enhanced treatment maintained the mechanical stability of printed materials during exposure to acidic, alkaline, and aqueous environments. Finally, the optimized approach enabled fabrication of a custom electrochemical reactor incorporating targeted acoustic stimulation, demonstrating the applicability of SLA manufacturing to highly sensitive and customized electrochemical platforms.
- 5 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnabling Additive Manufacturing of Reactors for Highly Sensitive Electrochemical Systems
Additive manufacturing enables rapid fabrication of customized electrochemical reactors; however, residual species from photopolymer resins can leach into electrolytes and interfere with sensitive electrochemical measurements. Here, we evaluate two commercial stereolithography resins and develop an enhanced post-processing strategy to minimize resin-derived contamination. Platinum electrodes exposed to two different resins processed according to manufacturer recommendations exhibited electrochemically active surface area losses of 45% and 10%, respectively, after 160 CV cycles. An optimized protocol combining solvent extraction with additional UV and thermal curing reduced these losses to 15% and 4.5%, respectively. Importantly, the enhanced treatment maintained the mechanical stability of printed materials during exposure to acidic, alkaline, and aqueous environments. Finally, the optimized approach enabled fabrication of a custom electrochemical reactor incorporating targeted acoustic stimulation, demonstrating the applicability of SLA manufacturing to highly sensitive and customized electrochemical platforms.
- Open Access
- 24 February 2026
- Published by Elsevier in SSRN Electronic Journal
Enhanced Oxygen Evolution in Nickel-Based Catalysts via Acoustic Stimulation
Nickel-based electrocatalysts remain one of the key materials for industrial alkaline water electrolysis applications. However, the tradeoff between high current densities and durability remains a challenge for these materials, mainly due to the slow deactivation of Ni electrodes over time. Herein, we report that through the introduction of externally-applied acoustic stimulation, the electrochemical activity of Ni electrocatalysts for the oxygen evolution reaction (OER) can not only be significantly improved but also recovered for deactivated Ni electrodes. The conditioning of Ni electrodes via acoustic stimulation improved OER current density by 36%. OER activity was recovered by up to 34% from aged Ni electrodes using on-demand acoustic excitations. Our results show that the observed improvement and recovery of activity are a result of a thinner, reactivated NiOxHy catalyst layer. The demonstrated ability to improve and recover OER activity from Ni-based electrocatalysts will enable alkaline electrolyzer systems to operate at higher current densities by mitigating their degradation, significantly extending their operational lifecycle.
- 24 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnhanced Oxygen Evolution in Nickel-Based Catalysts via Acoustic Stimulation
Nickel-based electrocatalysts remain one of the key materials for industrial alkaline water electrolysis applications. However, the tradeoff between high current densities and durability remains a challenge for these materials, mainly due to the slow deactivation of Ni electrodes over time. Herein, we report that through the introduction of externally-applied acoustic stimulation, the electrochemical activity of Ni electrocatalysts for the oxygen evolution reaction (OER) can not only be significantly improved but also recovered for deactivated Ni electrodes. The conditioning of Ni electrodes via acoustic stimulation improved OER current density by 36%. OER activity was recovered by up to 34% from aged Ni electrodes using on-demand acoustic excitations. Our results show that the observed improvement and recovery of activity are a result of a thinner, reactivated NiOxHy catalyst layer. The demonstrated ability to improve and recover OER activity from Ni-based electrocatalysts will enable alkaline electrolyzer systems to operate at higher current densities by mitigating their degradation, significantly extending their operational lifecycle.
- Open Access
Data-Driven Tailoring Optimization of Thermoset Polymers Using Ultrasonics and Machine Learning
Thermoset polymers are highly demanded for their structural robustness, thermal stability, and chemical resistance. Tailoring the properties of these polymers for high-performance applications is often preferred to designing brand-new polymers. However, the traditional destructive techniques used to characterize their properties as a function of manufacturing parameters are expensive and time-consuming. A novel non-destructive, data-driven method leveraging ultrasonics and machine learning techniques to tailor the properties of thermosets as a function of the manufacturing parameters is demonstrated. Thermoset epoxy samples with varying curing temperatures (15–40 °C) and curing agent amounts (±40%) were manufactured and tested. Their curing kinetics were monitored by determining the sound speed in the material in real time, while the longitudinal modulus of the samples was determined post-cure. Machine learning models were developed using a k-nearest neighbors algorithm. These models were implemented to predict the curing and final elastic properties using the manufacturing parameters, i.e., stoichiometry and curing temperature, and vice versa. Understanding and modeling how these parameters affect the cure kinetics and final properties will allow for efficient and reliable optimization of thermoset tailoring and manufacturing.
Open AccessData-Driven Tailoring Optimization of Thermoset Polymers Using Ultrasonics and Machine Learning
Thermoset polymers are highly demanded for their structural robustness, thermal stability, and chemical resistance. Tailoring the properties of these polymers for high-performance applications is often preferred to designing brand-new polymers. However, the traditional destructive techniques used to characterize their properties as a function of manufacturing parameters are expensive and time-consuming. A novel non-destructive, data-driven method leveraging ultrasonics and machine learning techniques to tailor the properties of thermosets as a function of the manufacturing parameters is demonstrated. Thermoset epoxy samples with varying curing temperatures (15–40 °C) and curing agent amounts (±40%) were manufactured and tested. Their curing kinetics were monitored by determining the sound speed in the material in real time, while the longitudinal modulus of the samples was determined post-cure. Machine learning models were developed using a k-nearest neighbors algorithm. These models were implemented to predict the curing and final elastic properties using the manufacturing parameters, i.e., stoichiometry and curing temperature, and vice versa. Understanding and modeling how these parameters affect the cure kinetics and final properties will allow for efficient and reliable optimization of thermoset tailoring and manufacturing.
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (2) , 154-168
Noninvasive Fluid-Level Sensing in Pipelines Using Ultrasonic Techniques
Accurate fluid level assessment in sealed pipelines is crucial in waste-water treatment and petrochemical plants, among others. The traditional pulse-echo time-of-flight measurements using ultrasound sensors to measure the fluid level are challenging for low fill levels due to signal contamination with multiple echoes and the resonances in the pipe wall. Though signal-processing strategies such as baseline subtraction and narrow-band filtering away from the pipe resonance frequencies improve pulse-echo measurements, low-fill level detection remains challenging. In this work, we identify these limitations of the pulse-echo technique and propose a resonance-based ultrasonic technique that is accurate and sensitive even at low-fill levels. This technique relies on the attenuation of pipe resonances in the presence of fluid, which is validated numerically using time-domain finite element simulations and experimentally performing resonance measurements on a fluid-filled pipe using an array of transducers. However, the pulse-echo and resonance techniques demand precise calibration with the pipe system before use. To mitigate the need for calibration, we propose a wedge-based phased array imaging technique based on the total focusing method (TFM) for fluid-level sensing. We discuss the challenges in wedge selection and array positioning and numerically validate the efficiency of TFM to provide better visualization of low fluid levels by employing a strategy to filter the image artifacts selectively. The presented ultrasonic techniques have significant industrial importance for applications requiring noninvasive fluid-level measurements.
- 3 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (2) , 154-168
Noninvasive Fluid-Level Sensing in Pipelines Using Ultrasonic Techniques
Accurate fluid level assessment in sealed pipelines is crucial in waste-water treatment and petrochemical plants, among others. The traditional pulse-echo time-of-flight measurements using ultrasound sensors to measure the fluid level are challenging for low fill levels due to signal contamination with multiple echoes and the resonances in the pipe wall. Though signal-processing strategies such as baseline subtraction and narrow-band filtering away from the pipe resonance frequencies improve pulse-echo measurements, low-fill level detection remains challenging. In this work, we identify these limitations of the pulse-echo technique and propose a resonance-based ultrasonic technique that is accurate and sensitive even at low-fill levels. This technique relies on the attenuation of pipe resonances in the presence of fluid, which is validated numerically using time-domain finite element simulations and experimentally performing resonance measurements on a fluid-filled pipe using an array of transducers. However, the pulse-echo and resonance techniques demand precise calibration with the pipe system before use. To mitigate the need for calibration, we propose a wedge-based phased array imaging technique based on the total focusing method (TFM) for fluid-level sensing. We discuss the challenges in wedge selection and array positioning and numerically validate the efficiency of TFM to provide better visualization of low fluid levels by employing a strategy to filter the image artifacts selectively. The presented ultrasonic techniques have significant industrial importance for applications requiring noninvasive fluid-level measurements.
- Open Access
- 4 October 2024
- Published by Elsevier in Machine Learning with Applications
- Vol. 18
Noninvasive pressure monitoring using acoustic resonance spectroscopy and machine learning
- 4 October 2024
- Published by Elsevier in Machine Learning with Applications
- Vol. 18
Open AccessNoninvasive pressure monitoring using acoustic resonance spectroscopy and machine learning
- Open Access
On the Generalizability of Time-of-Flight Convolutional Neural Networks for Noninvasive Acoustic Measurements
Bulk wave acoustic time-of-flight (ToF) measurements in pipes and closed containers can be hindered by guided waves with similar arrival times propagating in the container wall, especially when a low excitation frequency is used to mitigate sound attenuation from the material. Convolutional neural networks (CNNs) have emerged as a new paradigm for obtaining accurate ToF in non-destructive evaluation (NDE) and have been demonstrated for such complicated conditions. However, the generalizability of ToF-CNNs has not been investigated. In this work, we analyze the generalizability of the ToF-CNN for broader applications, given limited training data. We first investigate the CNN performance with respect to training dataset size and different training data and test data parameters (container dimensions and material properties). Furthermore, we perform a series of tests to understand the distribution of data parameters that need to be incorporated in training for enhanced model generalizability. This is investigated by training the model on a set of small- and large-container datasets regardless of the test data. We observe that the quantity of data partitioned for training must be of a good representation of the entire sets and sufficient to span through the input space. The result of the network also shows that the learning model with the training data on small containers delivers a sufficiently stable result on different feature interactions compared to the learning model with the training data on large containers. To check the robustness of the model, we tested the trained model to predict the ToF of different sound speed mediums, which shows excellent accuracy. Furthermore, to mimic real experimental scenarios, data are augmented by adding noise. We envision that the proposed approach will extend the applications of CNNs for ToF prediction in a broader range.
Open AccessOn the Generalizability of Time-of-Flight Convolutional Neural Networks for Noninvasive Acoustic Measurements
Bulk wave acoustic time-of-flight (ToF) measurements in pipes and closed containers can be hindered by guided waves with similar arrival times propagating in the container wall, especially when a low excitation frequency is used to mitigate sound attenuation from the material. Convolutional neural networks (CNNs) have emerged as a new paradigm for obtaining accurate ToF in non-destructive evaluation (NDE) and have been demonstrated for such complicated conditions. However, the generalizability of ToF-CNNs has not been investigated. In this work, we analyze the generalizability of the ToF-CNN for broader applications, given limited training data. We first investigate the CNN performance with respect to training dataset size and different training data and test data parameters (container dimensions and material properties). Furthermore, we perform a series of tests to understand the distribution of data parameters that need to be incorporated in training for enhanced model generalizability. This is investigated by training the model on a set of small- and large-container datasets regardless of the test data. We observe that the quantity of data partitioned for training must be of a good representation of the entire sets and sufficient to span through the input space. The result of the network also shows that the learning model with the training data on small containers delivers a sufficiently stable result on different feature interactions compared to the learning model with the training data on large containers. To check the robustness of the model, we tested the trained model to predict the ToF of different sound speed mediums, which shows excellent accuracy. Furthermore, to mimic real experimental scenarios, data are augmented by adding noise. We envision that the proposed approach will extend the applications of CNNs for ToF prediction in a broader range.