Vamshi Krishna Chillara
Vamshi Krishna Chillara has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Cliff J. Lissenden
15 shared publicationsCristian Pantea
Acoustics and Sensors Team, Materials Physics and Applications (MPA-11), Los Alamos National Laboratory, NM 87545, USA
10 shared publications- Cristian Pantea
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
9 shared publications Dipen N. Sinha
Acoustics and Sensors Team, Materials Physics and Applications (MPA-11), Los Alamos National Laboratory, USA 87545
7 shared publications- Eric Sean Davis
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
4 shared publications Hwanjeong Cho
Department of Engineering Science and Mechanics 2 , Penn State, University Park, Pennsylvania 16802, USA
4 shared publications
Latest Publications
- 26 October 2022
- Published by Elsevier in Ultrasonics
- Vol. 128, 106878
Specific resonance mode enhancement and suppression using non-uniform polarization of piezoelectric wafers: Theory and experiments
- 26 October 2022
- Published by Elsevier in Ultrasonics
- Vol. 128, 106878
Specific resonance mode enhancement and suppression using non-uniform polarization of piezoelectric wafers: Theory and experiments
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (4) , 1392-1398
Multilevel Frequency-Specific Information Storage Using Engineered Electromechanical Resonances in Piezoelectric Wafer Arrays
Multilevel information storage methods have the potential for increasing storage density and improving information security through obfuscation. Taking inspiration from the color quick response codes, we have developed a method for encoding layers of information in an array of thin piezoelectric wafers. Information storage is accomplished by altering the size of the circular polarization domain of individual wafers to engineer the response of the electromechanical resonances. By using this approach, we can store one layer of information per electromechanical resonance. In this study, we experimentally demonstrate this approach on a 20-element piezoelectric wafer array with up to two layers of information storage using binary encoding. We first discuss the relevant theory behind the proposed approach and the method for designing the polarization profiles for these wafer arrays to enable multilevel information storage. The effect of the size of the polarization domain on the strength of the electromechanical resonances and optimal size to enhance/suppress these resonances is discussed. Last, we describe how the proposed approach could be used to encode four or more layers of frequency-specific information. The proposed technology finds application in embedded barcodes, product tags, tamper-evident seals, and other secure applications such as shipping sensitive materials/containers.
- 25 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (4) , 1392-1398
Multilevel Frequency-Specific Information Storage Using Engineered Electromechanical Resonances in Piezoelectric Wafer Arrays
Multilevel information storage methods have the potential for increasing storage density and improving information security through obfuscation. Taking inspiration from the color quick response codes, we have developed a method for encoding layers of information in an array of thin piezoelectric wafers. Information storage is accomplished by altering the size of the circular polarization domain of individual wafers to engineer the response of the electromechanical resonances. By using this approach, we can store one layer of information per electromechanical resonance. In this study, we experimentally demonstrate this approach on a 20-element piezoelectric wafer array with up to two layers of information storage using binary encoding. We first discuss the relevant theory behind the proposed approach and the method for designing the polarization profiles for these wafer arrays to enable multilevel information storage. The effect of the size of the polarization domain on the strength of the electromechanical resonances and optimal size to enhance/suppress these resonances is discussed. Last, we describe how the proposed approach could be used to encode four or more layers of frequency-specific information. The proposed technology finds application in embedded barcodes, product tags, tamper-evident seals, and other secure applications such as shipping sensitive materials/containers.
- Open Access
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 2, 17-29
Tuning the Relative Strengths of Electromechanical Resonances Using Non-Uniform Polarization of Piezoelectric Wafers
A free piezoelectric disc with uniform polarization shows multiple radial modes of vibration that occur in the low-frequency range. The strength of these radial mode resonances is fixed and reduces with increasing frequency or mode number. In this article, we show that piezoelectric wafers can be designed with appropriate non-uniform polarization profiles to selectively excite single or any combination of multiple radial modes with an additional capability of altering the relative strengths of electromechanical resonances that is not possible with uniform polarization. We first discuss the theory behind our approach based on a Fourier-Bessel expansion technique. Then, we present several examples demonstrating the capability of tuning the relative strengths of electromechanical resonances in a piezoelectric disc using axisymmetric, non-uniform polarization profiles. The methodology presented in this article finds application in the design of single element transducers with multi-frequency operation, frequency-tuned sensors/receivers, collimated beam sources for underwater acoustics, and other non-traditional applications such as information storage.
- 10 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 2, 17-29
Open AccessTuning the Relative Strengths of Electromechanical Resonances Using Non-Uniform Polarization of Piezoelectric Wafers
A free piezoelectric disc with uniform polarization shows multiple radial modes of vibration that occur in the low-frequency range. The strength of these radial mode resonances is fixed and reduces with increasing frequency or mode number. In this article, we show that piezoelectric wafers can be designed with appropriate non-uniform polarization profiles to selectively excite single or any combination of multiple radial modes with an additional capability of altering the relative strengths of electromechanical resonances that is not possible with uniform polarization. We first discuss the theory behind our approach based on a Fourier-Bessel expansion technique. Then, we present several examples demonstrating the capability of tuning the relative strengths of electromechanical resonances in a piezoelectric disc using axisymmetric, non-uniform polarization profiles. The methodology presented in this article finds application in the design of single element transducers with multi-frequency operation, frequency-tuned sensors/receivers, collimated beam sources for underwater acoustics, and other non-traditional applications such as information storage.
- 1 July 2021
- Published by Elsevier in Ultrasonics
- Vol. 114, 106422
The effect of a transducer’s spatial averaging on an elastodynamic guided wave’s wavenumber spectrum
- 1 July 2021
- Published by Elsevier in Ultrasonics
- Vol. 114, 106422
The effect of a transducer’s spatial averaging on an elastodynamic guided wave’s wavenumber spectrum
- Open Access
- 7 May 2021
- Published by Morressier GmbH
Engineering the electromechanical response of piezoelectric transducers: some challenging applications
Piezoelectric transducers are widely used for ultrasonic applications both as actuators to excite and as sensors to receive vibration/wave response. The electromechanical characteristics of the piezoelectric transducers dictate their choice for specific applications. These can be tuned in several ways ranging from modifying the geometry and material properties of the element to
- 7 May 2021
- Published by Morressier GmbH
Open AccessEngineering the electromechanical response of piezoelectric transducers: some challenging applications
Piezoelectric transducers are widely used for ultrasonic applications both as actuators to excite and as sensors to receive vibration/wave response. The electromechanical characteristics of the piezoelectric transducers dictate their choice for specific applications. These can be tuned in several ways ranging from modifying the geometry and material properties of the element to
- Open Access
- 4 May 2021
- Published by ASME International in Journal of Vibration and Acoustics
- Vol. 143 (6)
On the Bandwidth and Beam Profile Characteristics of a Simple Low-Frequency Collimated Ultrasound Beam Source
We numerically investigate the bandwidth and collimation characteristics of ultrasound beams generated by a simple collimated ultrasound beam source that consists of a piezoelectric disk operated near its radial mode resonances. We simulate the ultrasound beam generated in a fluid medium as a function of the excitation frequency for two cases: (1) free piezoelectric disk that corresponds to zero-traction along the lateral edge and (2) fixed piezoelectric disk that corresponds to zero-displacement along the lateral edge. We present and discuss the physical mechanism underpinning the frequency-dependent collimation and bandwidth properties of the ultrasound beams. We observe that the collimated beam generated by the free disk repeatedly lengthens/shortens and also extends/retracts sidelobes with increasing frequency. Alternatively, fixing the piezoelectric disk results in a consistent beam profile shape across a broad range of frequencies. This facilitates generating broadband signals such as a Gaussian pulse or chirp, which are common in ultrasound imaging. Thus, the fixed piezoelectric disk finds application as a collimated ultrasound beam source in a wide range of applications including medical ultrasound imaging, scanning acoustic microscopy, sonar detection, and other nondestructive ultrasound inspection techniques.
- 4 May 2021
- Published by ASME International in Journal of Vibration and Acoustics
- Vol. 143 (6)
Open AccessOn the Bandwidth and Beam Profile Characteristics of a Simple Low-Frequency Collimated Ultrasound Beam Source
We numerically investigate the bandwidth and collimation characteristics of ultrasound beams generated by a simple collimated ultrasound beam source that consists of a piezoelectric disk operated near its radial mode resonances. We simulate the ultrasound beam generated in a fluid medium as a function of the excitation frequency for two cases: (1) free piezoelectric disk that corresponds to zero-traction along the lateral edge and (2) fixed piezoelectric disk that corresponds to zero-displacement along the lateral edge. We present and discuss the physical mechanism underpinning the frequency-dependent collimation and bandwidth properties of the ultrasound beams. We observe that the collimated beam generated by the free disk repeatedly lengthens/shortens and also extends/retracts sidelobes with increasing frequency. Alternatively, fixing the piezoelectric disk results in a consistent beam profile shape across a broad range of frequencies. This facilitates generating broadband signals such as a Gaussian pulse or chirp, which are common in ultrasound imaging. Thus, the fixed piezoelectric disk finds application as a collimated ultrasound beam source in a wide range of applications including medical ultrasound imaging, scanning acoustic microscopy, sonar detection, and other nondestructive ultrasound inspection techniques.
- Open Access
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (6) , 2251-2258
Noninvasive Acoustic Measurements in Cylindrical Shell Containers
Acoustic time-of-flight (ToF) measurements enable noninvasive material characterization, acoustic imaging, and defect detection and are commonly used in industrial process control, biomedical devices, and national security. When characterizing a fluid contained in a cylinder or pipe, ToF measurements are hampered by guided waves, which propagate around the cylindrical shell walls and obscure the waves propagating through the interrogated fluid. We present a technique for overcoming this limitation based on a broadband linear chirp excitation and cross correlation detection. By using broadband excitation, we exploit the dispersion of the guided waves, wherein different frequencies propagate at different velocities, thus distorting the guided wave signal while leaving the bulk wave signal in the fluid unperturbed. We demonstrate the measurement technique experimentally and using numerical simulation. We characterize the technique performance in terms of measurement error, signal-to-noise-ratio, and resolution as a function of the linear chirp center frequency and bandwidth. We discuss the physical phenomena behind the guided bulk wave interactions and how to utilize these phenomena to optimize the measurements in the fluid.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (6) , 2251-2258
Open AccessNoninvasive Acoustic Measurements in Cylindrical Shell Containers
Acoustic time-of-flight (ToF) measurements enable noninvasive material characterization, acoustic imaging, and defect detection and are commonly used in industrial process control, biomedical devices, and national security. When characterizing a fluid contained in a cylinder or pipe, ToF measurements are hampered by guided waves, which propagate around the cylindrical shell walls and obscure the waves propagating through the interrogated fluid. We present a technique for overcoming this limitation based on a broadband linear chirp excitation and cross correlation detection. By using broadband excitation, we exploit the dispersion of the guided waves, wherein different frequencies propagate at different velocities, thus distorting the guided wave signal while leaving the bulk wave signal in the fluid unperturbed. We demonstrate the measurement technique experimentally and using numerical simulation. We characterize the technique performance in terms of measurement error, signal-to-noise-ratio, and resolution as a function of the linear chirp center frequency and bandwidth. We discuss the physical phenomena behind the guided bulk wave interactions and how to utilize these phenomena to optimize the measurements in the fluid.
- Open Access
Multi-Level Information Storage Using Engineered Electromechanical Resonances of Piezoelectric Wafers: A Concept Piezoelectric Quick Response (PQR) Code
A piezoelectric-based method for information storage is presented. It involves engineering the polarization profiles of multiple piezoelectric wafers to enhance/suppress specific electromechanical resonances. These enhanced/suppressed resonances can be used to represent multiple frequency-dependent bits, thus enabling multi-level information storage. This multi-level information storage is demonstrated by achieving three information states for a ternary encoding. Using the three information states, we present an approach to encode and decode information from a 2-by-3 array of piezoelectric wafers that we refer to as a concept Piezoelectric Quick Response (PQR) code. The scaling relation between the number of wafers used and the cumulative number of information states that can be achieved with the proposed methodology is briefly discussed. Potential applications of this methodology include tamper-evident devices, embedded product tags in manufacturing/inventory tracking, and additional layers of security with existing information storage technologies.
Open AccessMulti-Level Information Storage Using Engineered Electromechanical Resonances of Piezoelectric Wafers: A Concept Piezoelectric Quick Response (PQR) Code
A piezoelectric-based method for information storage is presented. It involves engineering the polarization profiles of multiple piezoelectric wafers to enhance/suppress specific electromechanical resonances. These enhanced/suppressed resonances can be used to represent multiple frequency-dependent bits, thus enabling multi-level information storage. This multi-level information storage is demonstrated by achieving three information states for a ternary encoding. Using the three information states, we present an approach to encode and decode information from a 2-by-3 array of piezoelectric wafers that we refer to as a concept Piezoelectric Quick Response (PQR) code. The scaling relation between the number of wafers used and the cumulative number of information states that can be achieved with the proposed methodology is briefly discussed. Potential applications of this methodology include tamper-evident devices, embedded product tags in manufacturing/inventory tracking, and additional layers of security with existing information storage technologies.
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (4) , 1328-1346
A Physics-Based Signal Processing Approach for Noninvasive Ultrasonic Characterization of Multiphase Oil–Water–Gas Flows in a Pipe
A signal processing technique is presented for determining the composition of multiphase oil-water-gas flow in a pipe using noninvasive ultrasonic speed of sound measurements from a transmitter-receiver pair bonded to diametrically opposite sides of a pipe. A linear chirp excitation is used to send broadband ultrasonic energy that propagates in two paths from transmitter to receiver as: 1) a wave through the pipe-wall and then the multiphase mixture and 2) ultrasonic guided waves along the pipe-wall in the circumferential direction. As the ultrasonic attenuation of the multiphase mixture increases, the amplitude of the signal through the fluid mixture decreases relative to that of circumferential guided waves, making it difficult to determine the time-of-arrival of the fluid-path signal and hence the speed of sound in the mixture. The proposed signal processing technique overcomes this challenge by using a) a guided wave subtraction approach to suppress the strength of guided wave signals relative to the fluid-path signal and b) a Gaussian reconstruction approach for synthetic enhancement of the fluid-path signal by output signal reconstruction at frequencies corresponding to peak transmission of ultrasonic energy. The efficacy of the technique is demonstrated using experiments carried out in a field-scale flow loop with varying compositions of oil-water-gas mixtures. It is shown that the proposed approach can enhance the signal detectability by approximately 20 dB in comparison to the traditional approach that does not utilize guided wave subtraction and also improves the gas tolerance of composition measurements up to 20%.
- 25 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (4) , 1328-1346
A Physics-Based Signal Processing Approach for Noninvasive Ultrasonic Characterization of Multiphase Oil–Water–Gas Flows in a Pipe
A signal processing technique is presented for determining the composition of multiphase oil-water-gas flow in a pipe using noninvasive ultrasonic speed of sound measurements from a transmitter-receiver pair bonded to diametrically opposite sides of a pipe. A linear chirp excitation is used to send broadband ultrasonic energy that propagates in two paths from transmitter to receiver as: 1) a wave through the pipe-wall and then the multiphase mixture and 2) ultrasonic guided waves along the pipe-wall in the circumferential direction. As the ultrasonic attenuation of the multiphase mixture increases, the amplitude of the signal through the fluid mixture decreases relative to that of circumferential guided waves, making it difficult to determine the time-of-arrival of the fluid-path signal and hence the speed of sound in the mixture. The proposed signal processing technique overcomes this challenge by using a) a guided wave subtraction approach to suppress the strength of guided wave signals relative to the fluid-path signal and b) a Gaussian reconstruction approach for synthetic enhancement of the fluid-path signal by output signal reconstruction at frequencies corresponding to peak transmission of ultrasonic energy. The efficacy of the technique is demonstrated using experiments carried out in a field-scale flow loop with varying compositions of oil-water-gas mixtures. It is shown that the proposed approach can enhance the signal detectability by approximately 20 dB in comparison to the traditional approach that does not utilize guided wave subtraction and also improves the gas tolerance of composition measurements up to 20%.