Kamrul Hasan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kamrul Hasan has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Hasanul Aziz
Department of Computer Science, Marquette University, Milwaukee, WI, United States
2 shared publications - Ishrak Islam Zarif
Department of Computer Science, Marquette University, Milwaukee, WI, United States
2 shared publications - M. M. A. Hashem
Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna, Bangladesh
2 shared publications - Mahmudul Hasan
Stony Brook University, Stony Brook, NY, USA
2 shared publications - Richard Reed Love
Affiliation Amader Gram, Rampal, Bangladesh
2 shared publications - Sheikh Iqbal Ahamed
Department of Computer Science, Marquette University, Milwaukee, WI 53233, USA
2 shared publications
Latest Publications
- 16 February 2023
- Published by Taylor & Francis in International Journal of Human–Computer Interaction
- Vol. 40 (4) , 965-985
Design Recommendations towards Developing a Smartphone-Based Point-of-Care Tool for Rural Bangladeshi Users
Smartphone enhances healthcare support for everyone, from local to remote patients. Recent advancements in smartphone sensors redefine their usage and the prospect of remote point-of-care tools (e.g., blood diagnostic devices), especially for low-resource settings. This paper studies the sufferings of rural people due to the limited healthcare facilities and figures out the implications. The proliferation of smartphone users suggests converting many smartphones into point-of-care diagnosis devices would be a life-saving decision. Previous studies showed smartphone’s built-in camera captures physiological features (e.g., hemoglobin) from fingertip videos captured under different lights. So, we created a mobile application and attachments (light sources) to record fingertip videos for hemoglobin level calculation. Then we collected feedback on how the rural users interacted with the application. Finally, we applied qualitative and quantitative analysis to investigate their answers. Their invaluable feedback reflected the implications of various aspects of a smartphone-based point-of-care tool. The findings unveil how rural-area people can receive a smartphone's blood diagnostic services. Our results will facilitate mobile health application designers and developers to build a smartphone-based point-of-care tool for any rural area people.
- 16 February 2023
- Published by Taylor & Francis in International Journal of Human–Computer Interaction
- Vol. 40 (4) , 965-985
Design Recommendations towards Developing a Smartphone-Based Point-of-Care Tool for Rural Bangladeshi Users
Smartphone enhances healthcare support for everyone, from local to remote patients. Recent advancements in smartphone sensors redefine their usage and the prospect of remote point-of-care tools (e.g., blood diagnostic devices), especially for low-resource settings. This paper studies the sufferings of rural people due to the limited healthcare facilities and figures out the implications. The proliferation of smartphone users suggests converting many smartphones into point-of-care diagnosis devices would be a life-saving decision. Previous studies showed smartphone’s built-in camera captures physiological features (e.g., hemoglobin) from fingertip videos captured under different lights. So, we created a mobile application and attachments (light sources) to record fingertip videos for hemoglobin level calculation. Then we collected feedback on how the rural users interacted with the application. Finally, we applied qualitative and quantitative analysis to investigate their answers. Their invaluable feedback reflected the implications of various aspects of a smartphone-based point-of-care tool. The findings unveil how rural-area people can receive a smartphone's blood diagnostic services. Our results will facilitate mobile health application designers and developers to build a smartphone-based point-of-care tool for any rural area people.
- Open Access
- 11 November 2021
- Published by Bangladesh Academy of Sciences in Chattagram Maa-O-Shishu Hospital Medical College Journal
- Vol. 20 (2) , 28-31
Space Closure Rate in Mandibular Canine Retraction by Elastomeric Power Chain: A Clinical Trial
Background : On a daily basis, orthodontic patients present with malocclusions and orofacial imbalance. Often times, teeth must be extracted in order to obtain proper esthetics, occlusion, and stability as well as extraction of teeth is often a need to close residual space, after the initial decrowding and aligning. Pre adjusted fixed orthodontic appliances commonly utilize sliding mechanics for space closure with different types of force delivery systems. A variety of materials have been used as force delivery systems to close spaces between teeth as in the case of canine retraction after the extraction of premolars. Elastomeric auxiliaries are relatively consistent in producing tooth movements. The purpose of the study to evaluate the rate of mandibular canine retraction by elastomeric power chain. Materials and methods : This obervational study was designed as split mouth study. A total number of 20 patients (40 quadrants),who required canine retraction into first premolar extraction sites as part of their orthodontic treatment in the Department of Orthodontics, BSMMU as study population. The quadrants were affixed by elastomeric power chain (Dentaurum) with 200gm force measured by Correx Tension Gauge. Space closure was measured by means of direct measurement from the mesial surface of mesial wing of the 2nd premolar bracket and the distal surface of distal wing of the canine bracket with digital Vernier Calipers. Results: Mean space closer rate in mandibular canine retraction was 0.99 ± 0.08 mm/month in elastomeric power chain method with p valueConclusion : This study revealed that space closer rate in mandibular canine retraction was 0.99 ± 0.08 mm/month by elastomeric power chain. Chatt Maa Shi Hosp Med Coll J; Vol.20 (2); July 2021; Page 28-31
- 11 November 2021
- Published by Bangladesh Academy of Sciences in Chattagram Maa-O-Shishu Hospital Medical College Journal
- Vol. 20 (2) , 28-31
Open AccessSpace Closure Rate in Mandibular Canine Retraction by Elastomeric Power Chain: A Clinical Trial
Background : On a daily basis, orthodontic patients present with malocclusions and orofacial imbalance. Often times, teeth must be extracted in order to obtain proper esthetics, occlusion, and stability as well as extraction of teeth is often a need to close residual space, after the initial decrowding and aligning. Pre adjusted fixed orthodontic appliances commonly utilize sliding mechanics for space closure with different types of force delivery systems. A variety of materials have been used as force delivery systems to close spaces between teeth as in the case of canine retraction after the extraction of premolars. Elastomeric auxiliaries are relatively consistent in producing tooth movements. The purpose of the study to evaluate the rate of mandibular canine retraction by elastomeric power chain. Materials and methods : This obervational study was designed as split mouth study. A total number of 20 patients (40 quadrants),who required canine retraction into first premolar extraction sites as part of their orthodontic treatment in the Department of Orthodontics, BSMMU as study population. The quadrants were affixed by elastomeric power chain (Dentaurum) with 200gm force measured by Correx Tension Gauge. Space closure was measured by means of direct measurement from the mesial surface of mesial wing of the 2nd premolar bracket and the distal surface of distal wing of the canine bracket with digital Vernier Calipers. Results: Mean space closer rate in mandibular canine retraction was 0.99 ± 0.08 mm/month in elastomeric power chain method with p valueConclusion : This study revealed that space closer rate in mandibular canine retraction was 0.99 ± 0.08 mm/month by elastomeric power chain. Chatt Maa Shi Hosp Med Coll J; Vol.20 (2); July 2021; Page 28-31
- Open Access
- 8 April 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (4) , e16806
Noninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations
Background: There is worldwide demand for an affordable hemoglobin measurement solution, which is a particularly urgent need in developing countries. The smartphone, which is the most penetrated device in both rich and resource-constrained areas, would be a suitable choice to build this solution. Consideration of a smartphone-based hemoglobin measurement tool is compelling because of the possibilities for an affordable, portable, and reliable point-of-care tool by leveraging the camera capacity, computing power, and lighting sources of the smartphone. However, several smartphone-based hemoglobin measurement techniques have encountered significant challenges with respect to data collection methods, sensor selection, signal analysis processes, and machine-learning algorithms. Therefore, a comprehensive analysis of invasive, minimally invasive, and noninvasive methods is required to recommend a hemoglobin measurement process using a smartphone device. Objective: In this study, we analyzed existing invasive, minimally invasive, and noninvasive approaches for blood hemoglobin level measurement with the goal of recommending data collection techniques, signal extraction processes, feature calculation strategies, theoretical foundation, and machine-learning algorithms for developing a noninvasive hemoglobin level estimation point-of-care tool using a smartphone. Methods: We explored research papers related to invasive, minimally invasive, and noninvasive hemoglobin level measurement processes. We investigated the challenges and opportunities of each technique. We compared the variation in data collection sites, biosignal processing techniques, theoretical foundations, photoplethysmogram (PPG) signal and features extraction process, machine-learning algorithms, and prediction models to calculate hemoglobin levels. This analysis was then used to recommend realistic approaches to build a smartphone-based point-of-care tool for hemoglobin measurement in a noninvasive manner. Results: The fingertip area is one of the best data collection sites from the body, followed by the lower eye conjunctival area. Near-infrared (NIR) light-emitting diode (LED) light with wavelengths of 850 nm, 940 nm, and 1070 nm were identified as potential light sources to receive a hemoglobin response from living tissue. PPG signals from fingertip videos, captured under various light sources, can provide critical physiological clues. The features of PPG signals captured under 1070 nm and 850 nm NIR LED are considered to be the best signal combinations following a dual-wavelength theoretical foundation. For error metrics presentation, we recommend the mean absolute percentage error, mean squared error, correlation coefficient, and Bland-Altman plot. Conclusions: We addressed the challenges of developing an affordable, portable, and reliable point-of-care tool for hemoglobin measurement using a smartphone. Leveraging the smartphone’s camera capacity, computing power, and lighting sources, we define specific recommendations for practical point-of-care solution development. We further provide recommendations to resolve several long-standing research questions, including how to capture a signal using a smartphone camera, select the best body site for signal collection, and overcome noise issues in the smartphone-captured signal. We also describe the process of extracting a signal’s features after capturing the signal based on fundamental theory. The list of machine-learning algorithms provided will be useful for processing PPG features. These recommendations should be valuable for future investigators seeking to build a reliable and affordable hemoglobin prediction model using a smartphone.
- 8 April 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (4) , e16806
Open AccessNoninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations
Background: There is worldwide demand for an affordable hemoglobin measurement solution, which is a particularly urgent need in developing countries. The smartphone, which is the most penetrated device in both rich and resource-constrained areas, would be a suitable choice to build this solution. Consideration of a smartphone-based hemoglobin measurement tool is compelling because of the possibilities for an affordable, portable, and reliable point-of-care tool by leveraging the camera capacity, computing power, and lighting sources of the smartphone. However, several smartphone-based hemoglobin measurement techniques have encountered significant challenges with respect to data collection methods, sensor selection, signal analysis processes, and machine-learning algorithms. Therefore, a comprehensive analysis of invasive, minimally invasive, and noninvasive methods is required to recommend a hemoglobin measurement process using a smartphone device. Objective: In this study, we analyzed existing invasive, minimally invasive, and noninvasive approaches for blood hemoglobin level measurement with the goal of recommending data collection techniques, signal extraction processes, feature calculation strategies, theoretical foundation, and machine-learning algorithms for developing a noninvasive hemoglobin level estimation point-of-care tool using a smartphone. Methods: We explored research papers related to invasive, minimally invasive, and noninvasive hemoglobin level measurement processes. We investigated the challenges and opportunities of each technique. We compared the variation in data collection sites, biosignal processing techniques, theoretical foundations, photoplethysmogram (PPG) signal and features extraction process, machine-learning algorithms, and prediction models to calculate hemoglobin levels. This analysis was then used to recommend realistic approaches to build a smartphone-based point-of-care tool for hemoglobin measurement in a noninvasive manner. Results: The fingertip area is one of the best data collection sites from the body, followed by the lower eye conjunctival area. Near-infrared (NIR) light-emitting diode (LED) light with wavelengths of 850 nm, 940 nm, and 1070 nm were identified as potential light sources to receive a hemoglobin response from living tissue. PPG signals from fingertip videos, captured under various light sources, can provide critical physiological clues. The features of PPG signals captured under 1070 nm and 850 nm NIR LED are considered to be the best signal combinations following a dual-wavelength theoretical foundation. For error metrics presentation, we recommend the mean absolute percentage error, mean squared error, correlation coefficient, and Bland-Altman plot. Conclusions: We addressed the challenges of developing an affordable, portable, and reliable point-of-care tool for hemoglobin measurement using a smartphone. Leveraging the smartphone’s camera capacity, computing power, and lighting sources, we define specific recommendations for practical point-of-care solution development. We further provide recommendations to resolve several long-standing research questions, including how to capture a signal using a smartphone camera, select the best body site for signal collection, and overcome noise issues in the smartphone-captured signal. We also describe the process of extracting a signal’s features after capturing the signal based on fundamental theory. The list of machine-learning algorithms provided will be useful for processing PPG features. These recommendations should be valuable for future investigators seeking to build a reliable and affordable hemoglobin prediction model using a smartphone.
- Open Access
- 26 October 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Noninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations (Preprint)
BACKGROUND There is worldwide demand for an affordable hemoglobin measurement solution, which is a particularly urgent need in developing countries. The smartphone, which is the most penetrated device in both rich and resource-constrained areas, would be a suitable choice to build this solution. Consideration of a smartphone-based hemoglobin measurement tool is compelling because of the possibilities for an affordable, portable, and reliable point-of-care tool by leveraging the camera capacity, computing power, and lighting sources of the smartphone. However, several smartphone-based hemoglobin measurement techniques have encountered significant challenges with respect to data collection methods, sensor selection, signal analysis processes, and machine-learning algorithms. Therefore, a comprehensive analysis of invasive, minimally invasive, and noninvasive methods is required to recommend a hemoglobin measurement process using a smartphone device. OBJECTIVE In this study, we analyzed existing invasive, minimally invasive, and noninvasive approaches for blood hemoglobin level measurement with the goal of recommending data collection techniques, signal extraction processes, feature calculation strategies, theoretical foundation, and machine-learning algorithms for developing a noninvasive hemoglobin level estimation point-of-care tool using a smartphone. METHODS We explored research papers related to invasive, minimally invasive, and noninvasive hemoglobin level measurement processes. We investigated the challenges and opportunities of each technique. We compared the variation in data collection sites, biosignal processing techniques, theoretical foundations, photoplethysmogram (PPG) signal and features extraction process, machine-learning algorithms, and prediction models to calculate hemoglobin levels. This analysis was then used to recommend realistic approaches to build a smartphone-based point-of-care tool for hemoglobin measurement in a noninvasive manner. RESULTS The fingertip area is one of the best data collection sites from the body, followed by the lower eye conjunctival area. Near-infrared (NIR) light-emitting diode (LED) light with wavelengths of 850 nm, 940 nm, and 1070 nm were identified as potential light sources to receive a hemoglobin response from living tissue. PPG signals from fingertip videos, captured under various light sources, can provide critical physiological clues. The features of PPG signals captured under 1070 nm and 850 nm NIR LED are considered to be the best signal combinations following a dual-wavelength theoretical foundation. For error metrics presentation, we recommend the mean absolute percentage error, mean squared error, correlation coefficient, and Bland-Altman plot. CONCLUSIONS We addressed the challenges of developing an affordable, portable, and reliable point-of-care tool for hemoglobin measurement using a smartphone. Leveraging the smartphone’s camera capacity, computing power, and lighting sources, we define specific recommendations for practical point-of-care solution development. We further provide recommendations to resolve several long-standing research questions, including how to capture a signal using a smartphone camera, select the best body site for signal collection, and overcome noise issues in the smartphone-captured signal. We also describe the process of extracting a signal’s features after capturing the signal based on fundamental theory. The list of machine-learning algorithms provided will be useful for processing PPG features. These recommendations should be valuable for future investigators seeking to build a reliable and affordable hemoglobin prediction model using a smartphone.
- 26 October 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessNoninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations (Preprint)
BACKGROUND There is worldwide demand for an affordable hemoglobin measurement solution, which is a particularly urgent need in developing countries. The smartphone, which is the most penetrated device in both rich and resource-constrained areas, would be a suitable choice to build this solution. Consideration of a smartphone-based hemoglobin measurement tool is compelling because of the possibilities for an affordable, portable, and reliable point-of-care tool by leveraging the camera capacity, computing power, and lighting sources of the smartphone. However, several smartphone-based hemoglobin measurement techniques have encountered significant challenges with respect to data collection methods, sensor selection, signal analysis processes, and machine-learning algorithms. Therefore, a comprehensive analysis of invasive, minimally invasive, and noninvasive methods is required to recommend a hemoglobin measurement process using a smartphone device. OBJECTIVE In this study, we analyzed existing invasive, minimally invasive, and noninvasive approaches for blood hemoglobin level measurement with the goal of recommending data collection techniques, signal extraction processes, feature calculation strategies, theoretical foundation, and machine-learning algorithms for developing a noninvasive hemoglobin level estimation point-of-care tool using a smartphone. METHODS We explored research papers related to invasive, minimally invasive, and noninvasive hemoglobin level measurement processes. We investigated the challenges and opportunities of each technique. We compared the variation in data collection sites, biosignal processing techniques, theoretical foundations, photoplethysmogram (PPG) signal and features extraction process, machine-learning algorithms, and prediction models to calculate hemoglobin levels. This analysis was then used to recommend realistic approaches to build a smartphone-based point-of-care tool for hemoglobin measurement in a noninvasive manner. RESULTS The fingertip area is one of the best data collection sites from the body, followed by the lower eye conjunctival area. Near-infrared (NIR) light-emitting diode (LED) light with wavelengths of 850 nm, 940 nm, and 1070 nm were identified as potential light sources to receive a hemoglobin response from living tissue. PPG signals from fingertip videos, captured under various light sources, can provide critical physiological clues. The features of PPG signals captured under 1070 nm and 850 nm NIR LED are considered to be the best signal combinations following a dual-wavelength theoretical foundation. For error metrics presentation, we recommend the mean absolute percentage error, mean squared error, correlation coefficient, and Bland-Altman plot. CONCLUSIONS We addressed the challenges of developing an affordable, portable, and reliable point-of-care tool for hemoglobin measurement using a smartphone. Leveraging the smartphone’s camera capacity, computing power, and lighting sources, we define specific recommendations for practical point-of-care solution development. We further provide recommendations to resolve several long-standing research questions, including how to capture a signal using a smartphone camera, select the best body site for signal collection, and overcome noise issues in the smartphone-captured signal. We also describe the process of extracting a signal’s features after capturing the signal based on fundamental theory. The list of machine-learning algorithms provided will be useful for processing PPG features. These recommendations should be valuable for future investigators seeking to build a reliable and affordable hemoglobin prediction model using a smartphone.
- 1 April 2019
- Published by Elsevier in Patient Education and Counseling
- Vol. 102 (4) , 701-708
Smartphone-based prenatal education for parents with preterm birth risk factors
- 1 April 2019
- Published by Elsevier in Patient Education and Counseling
- Vol. 102 (4) , 701-708
Smartphone-based prenatal education for parents with preterm birth risk factors