Hasanul Aziz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hasanul Aziz has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Richard Reed Love
Affiliation Amader Gram, Rampal, Bangladesh
3 shared publications - Sheikh Iqbal Ahamed
Department of Computer Science, Marquette University, Milwaukee, WI 53233, USA
3 shared publications - Ishrak Islam Zarif
Department of Computer Science, Marquette University, Milwaukee, WI, United States
2 shared publications - Kamrul Hasan
Department of Computer Science, Vanderbilt University, Nashville, TN, USA
2 shared publications - M. M. A. Hashem
Department of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna, Bangladesh
2 shared publications - Mahmudul Hasan
Stony Brook University, Stony Brook, NY, USA
2 shared publications
Latest Publications
- Open Access
- 8 April 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (4) , e16806
Noninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations
Background: There is worldwide demand for an affordable hemoglobin measurement solution, which is a particularly urgent need in developing countries. The smartphone, which is the most penetrated device in both rich and resource-constrained areas, would be a suitable choice to build this solution. Consideration of a smartphone-based hemoglobin measurement tool is compelling because of the possibilities for an affordable, portable, and reliable point-of-care tool by leveraging the camera capacity, computing power, and lighting sources of the smartphone. However, several smartphone-based hemoglobin measurement techniques have encountered significant challenges with respect to data collection methods, sensor selection, signal analysis processes, and machine-learning algorithms. Therefore, a comprehensive analysis of invasive, minimally invasive, and noninvasive methods is required to recommend a hemoglobin measurement process using a smartphone device. Objective: In this study, we analyzed existing invasive, minimally invasive, and noninvasive approaches for blood hemoglobin level measurement with the goal of recommending data collection techniques, signal extraction processes, feature calculation strategies, theoretical foundation, and machine-learning algorithms for developing a noninvasive hemoglobin level estimation point-of-care tool using a smartphone. Methods: We explored research papers related to invasive, minimally invasive, and noninvasive hemoglobin level measurement processes. We investigated the challenges and opportunities of each technique. We compared the variation in data collection sites, biosignal processing techniques, theoretical foundations, photoplethysmogram (PPG) signal and features extraction process, machine-learning algorithms, and prediction models to calculate hemoglobin levels. This analysis was then used to recommend realistic approaches to build a smartphone-based point-of-care tool for hemoglobin measurement in a noninvasive manner. Results: The fingertip area is one of the best data collection sites from the body, followed by the lower eye conjunctival area. Near-infrared (NIR) light-emitting diode (LED) light with wavelengths of 850 nm, 940 nm, and 1070 nm were identified as potential light sources to receive a hemoglobin response from living tissue. PPG signals from fingertip videos, captured under various light sources, can provide critical physiological clues. The features of PPG signals captured under 1070 nm and 850 nm NIR LED are considered to be the best signal combinations following a dual-wavelength theoretical foundation. For error metrics presentation, we recommend the mean absolute percentage error, mean squared error, correlation coefficient, and Bland-Altman plot. Conclusions: We addressed the challenges of developing an affordable, portable, and reliable point-of-care tool for hemoglobin measurement using a smartphone. Leveraging the smartphone’s camera capacity, computing power, and lighting sources, we define specific recommendations for practical point-of-care solution development. We further provide recommendations to resolve several long-standing research questions, including how to capture a signal using a smartphone camera, select the best body site for signal collection, and overcome noise issues in the smartphone-captured signal. We also describe the process of extracting a signal’s features after capturing the signal based on fundamental theory. The list of machine-learning algorithms provided will be useful for processing PPG features. These recommendations should be valuable for future investigators seeking to build a reliable and affordable hemoglobin prediction model using a smartphone.
- 8 April 2021
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 9 (4) , e16806
Open AccessNoninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations
Background: There is worldwide demand for an affordable hemoglobin measurement solution, which is a particularly urgent need in developing countries. The smartphone, which is the most penetrated device in both rich and resource-constrained areas, would be a suitable choice to build this solution. Consideration of a smartphone-based hemoglobin measurement tool is compelling because of the possibilities for an affordable, portable, and reliable point-of-care tool by leveraging the camera capacity, computing power, and lighting sources of the smartphone. However, several smartphone-based hemoglobin measurement techniques have encountered significant challenges with respect to data collection methods, sensor selection, signal analysis processes, and machine-learning algorithms. Therefore, a comprehensive analysis of invasive, minimally invasive, and noninvasive methods is required to recommend a hemoglobin measurement process using a smartphone device. Objective: In this study, we analyzed existing invasive, minimally invasive, and noninvasive approaches for blood hemoglobin level measurement with the goal of recommending data collection techniques, signal extraction processes, feature calculation strategies, theoretical foundation, and machine-learning algorithms for developing a noninvasive hemoglobin level estimation point-of-care tool using a smartphone. Methods: We explored research papers related to invasive, minimally invasive, and noninvasive hemoglobin level measurement processes. We investigated the challenges and opportunities of each technique. We compared the variation in data collection sites, biosignal processing techniques, theoretical foundations, photoplethysmogram (PPG) signal and features extraction process, machine-learning algorithms, and prediction models to calculate hemoglobin levels. This analysis was then used to recommend realistic approaches to build a smartphone-based point-of-care tool for hemoglobin measurement in a noninvasive manner. Results: The fingertip area is one of the best data collection sites from the body, followed by the lower eye conjunctival area. Near-infrared (NIR) light-emitting diode (LED) light with wavelengths of 850 nm, 940 nm, and 1070 nm were identified as potential light sources to receive a hemoglobin response from living tissue. PPG signals from fingertip videos, captured under various light sources, can provide critical physiological clues. The features of PPG signals captured under 1070 nm and 850 nm NIR LED are considered to be the best signal combinations following a dual-wavelength theoretical foundation. For error metrics presentation, we recommend the mean absolute percentage error, mean squared error, correlation coefficient, and Bland-Altman plot. Conclusions: We addressed the challenges of developing an affordable, portable, and reliable point-of-care tool for hemoglobin measurement using a smartphone. Leveraging the smartphone’s camera capacity, computing power, and lighting sources, we define specific recommendations for practical point-of-care solution development. We further provide recommendations to resolve several long-standing research questions, including how to capture a signal using a smartphone camera, select the best body site for signal collection, and overcome noise issues in the smartphone-captured signal. We also describe the process of extracting a signal’s features after capturing the signal based on fundamental theory. The list of machine-learning algorithms provided will be useful for processing PPG features. These recommendations should be valuable for future investigators seeking to build a reliable and affordable hemoglobin prediction model using a smartphone.
- Open Access
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1385-1396
Automated Cardiac Pulse Cycle Analysis From Photoplethysmogram (PPG) Signals Generated From Fingertip Videos Captured Using a Smartphone to Measure Blood Hemoglobin Levels
Two billion people are affected by hemoglobin (Hgb) related diseases. Usual clinical assessments of hemoglobin are conducted by analyzing venipuncture-obtained blood samples in laboratories. A non-invasive, cheap, point-of-care, and accurate hemoglobin test is needed everywhere. Our group has developed a non-invasive hemoglobin (Hgb) measurement system using 10-second Smartphone videos of the index fingertips. Custom hardware sets were used to illuminate the fingers. We tested four lighting conditions with wavelengths in the near-infrared spectrum suggested by the absorption properties of two primary components of blood-oxygenated hemoglobin and plasma. We found a strong linear correlation between our measured and laboratory-measured hemoglobin levels in 167 patients with a mean absolute percentage error (MAPE) of 5%. In our initial analysis, critical tasks were performed manually. Now, using the same data, we have automated or modified all the steps. For female subjects, we found a MAPE of 5.34% and MSE of 0.49. The new analyses, however, have suggested inexplicable inconsistencies in our results, which we attribute to laboratory measurement errors reflected in a non-normative distribution of hemoglobin levels in our studied patients, as well as excess noise in the specific signals we measured in the videos. Based on these encouraging results, and the promise of greater accuracy with our revised hardware and software tools, we now propose a rigorous validation study to demonstrate that this approach to hemoglobin measurement is appropriate for general clinical application.
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (5) , 1385-1396
Open AccessAutomated Cardiac Pulse Cycle Analysis From Photoplethysmogram (PPG) Signals Generated From Fingertip Videos Captured Using a Smartphone to Measure Blood Hemoglobin Levels
Two billion people are affected by hemoglobin (Hgb) related diseases. Usual clinical assessments of hemoglobin are conducted by analyzing venipuncture-obtained blood samples in laboratories. A non-invasive, cheap, point-of-care, and accurate hemoglobin test is needed everywhere. Our group has developed a non-invasive hemoglobin (Hgb) measurement system using 10-second Smartphone videos of the index fingertips. Custom hardware sets were used to illuminate the fingers. We tested four lighting conditions with wavelengths in the near-infrared spectrum suggested by the absorption properties of two primary components of blood-oxygenated hemoglobin and plasma. We found a strong linear correlation between our measured and laboratory-measured hemoglobin levels in 167 patients with a mean absolute percentage error (MAPE) of 5%. In our initial analysis, critical tasks were performed manually. Now, using the same data, we have automated or modified all the steps. For female subjects, we found a MAPE of 5.34% and MSE of 0.49. The new analyses, however, have suggested inexplicable inconsistencies in our results, which we attribute to laboratory measurement errors reflected in a non-normative distribution of hemoglobin levels in our studied patients, as well as excess noise in the specific signals we measured in the videos. Based on these encouraging results, and the promise of greater accuracy with our revised hardware and software tools, we now propose a rigorous validation study to demonstrate that this approach to hemoglobin measurement is appropriate for general clinical application.
- Open Access
- 26 October 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Noninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations (Preprint)
BACKGROUND There is worldwide demand for an affordable hemoglobin measurement solution, which is a particularly urgent need in developing countries. The smartphone, which is the most penetrated device in both rich and resource-constrained areas, would be a suitable choice to build this solution. Consideration of a smartphone-based hemoglobin measurement tool is compelling because of the possibilities for an affordable, portable, and reliable point-of-care tool by leveraging the camera capacity, computing power, and lighting sources of the smartphone. However, several smartphone-based hemoglobin measurement techniques have encountered significant challenges with respect to data collection methods, sensor selection, signal analysis processes, and machine-learning algorithms. Therefore, a comprehensive analysis of invasive, minimally invasive, and noninvasive methods is required to recommend a hemoglobin measurement process using a smartphone device. OBJECTIVE In this study, we analyzed existing invasive, minimally invasive, and noninvasive approaches for blood hemoglobin level measurement with the goal of recommending data collection techniques, signal extraction processes, feature calculation strategies, theoretical foundation, and machine-learning algorithms for developing a noninvasive hemoglobin level estimation point-of-care tool using a smartphone. METHODS We explored research papers related to invasive, minimally invasive, and noninvasive hemoglobin level measurement processes. We investigated the challenges and opportunities of each technique. We compared the variation in data collection sites, biosignal processing techniques, theoretical foundations, photoplethysmogram (PPG) signal and features extraction process, machine-learning algorithms, and prediction models to calculate hemoglobin levels. This analysis was then used to recommend realistic approaches to build a smartphone-based point-of-care tool for hemoglobin measurement in a noninvasive manner. RESULTS The fingertip area is one of the best data collection sites from the body, followed by the lower eye conjunctival area. Near-infrared (NIR) light-emitting diode (LED) light with wavelengths of 850 nm, 940 nm, and 1070 nm were identified as potential light sources to receive a hemoglobin response from living tissue. PPG signals from fingertip videos, captured under various light sources, can provide critical physiological clues. The features of PPG signals captured under 1070 nm and 850 nm NIR LED are considered to be the best signal combinations following a dual-wavelength theoretical foundation. For error metrics presentation, we recommend the mean absolute percentage error, mean squared error, correlation coefficient, and Bland-Altman plot. CONCLUSIONS We addressed the challenges of developing an affordable, portable, and reliable point-of-care tool for hemoglobin measurement using a smartphone. Leveraging the smartphone’s camera capacity, computing power, and lighting sources, we define specific recommendations for practical point-of-care solution development. We further provide recommendations to resolve several long-standing research questions, including how to capture a signal using a smartphone camera, select the best body site for signal collection, and overcome noise issues in the smartphone-captured signal. We also describe the process of extracting a signal’s features after capturing the signal based on fundamental theory. The list of machine-learning algorithms provided will be useful for processing PPG features. These recommendations should be valuable for future investigators seeking to build a reliable and affordable hemoglobin prediction model using a smartphone.
- 26 October 2019
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessNoninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations (Preprint)
BACKGROUND There is worldwide demand for an affordable hemoglobin measurement solution, which is a particularly urgent need in developing countries. The smartphone, which is the most penetrated device in both rich and resource-constrained areas, would be a suitable choice to build this solution. Consideration of a smartphone-based hemoglobin measurement tool is compelling because of the possibilities for an affordable, portable, and reliable point-of-care tool by leveraging the camera capacity, computing power, and lighting sources of the smartphone. However, several smartphone-based hemoglobin measurement techniques have encountered significant challenges with respect to data collection methods, sensor selection, signal analysis processes, and machine-learning algorithms. Therefore, a comprehensive analysis of invasive, minimally invasive, and noninvasive methods is required to recommend a hemoglobin measurement process using a smartphone device. OBJECTIVE In this study, we analyzed existing invasive, minimally invasive, and noninvasive approaches for blood hemoglobin level measurement with the goal of recommending data collection techniques, signal extraction processes, feature calculation strategies, theoretical foundation, and machine-learning algorithms for developing a noninvasive hemoglobin level estimation point-of-care tool using a smartphone. METHODS We explored research papers related to invasive, minimally invasive, and noninvasive hemoglobin level measurement processes. We investigated the challenges and opportunities of each technique. We compared the variation in data collection sites, biosignal processing techniques, theoretical foundations, photoplethysmogram (PPG) signal and features extraction process, machine-learning algorithms, and prediction models to calculate hemoglobin levels. This analysis was then used to recommend realistic approaches to build a smartphone-based point-of-care tool for hemoglobin measurement in a noninvasive manner. RESULTS The fingertip area is one of the best data collection sites from the body, followed by the lower eye conjunctival area. Near-infrared (NIR) light-emitting diode (LED) light with wavelengths of 850 nm, 940 nm, and 1070 nm were identified as potential light sources to receive a hemoglobin response from living tissue. PPG signals from fingertip videos, captured under various light sources, can provide critical physiological clues. The features of PPG signals captured under 1070 nm and 850 nm NIR LED are considered to be the best signal combinations following a dual-wavelength theoretical foundation. For error metrics presentation, we recommend the mean absolute percentage error, mean squared error, correlation coefficient, and Bland-Altman plot. CONCLUSIONS We addressed the challenges of developing an affordable, portable, and reliable point-of-care tool for hemoglobin measurement using a smartphone. Leveraging the smartphone’s camera capacity, computing power, and lighting sources, we define specific recommendations for practical point-of-care solution development. We further provide recommendations to resolve several long-standing research questions, including how to capture a signal using a smartphone camera, select the best body site for signal collection, and overcome noise issues in the smartphone-captured signal. We also describe the process of extracting a signal’s features after capturing the signal based on fundamental theory. The list of machine-learning algorithms provided will be useful for processing PPG features. These recommendations should be valuable for future investigators seeking to build a reliable and affordable hemoglobin prediction model using a smartphone.