Micaela Cunha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Micaela Cunha has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Michael Beuve
Université Claude Bernard Lyon 1
7 shared publications Etienne Testa
B Department of Radiation Sciences , Université de Lyon , Lyon , France
5 shared publications- Marco Pinto
Ludwig-Maximilians-Universität München
3 shared publications - Paulo Crespo
LIP - Laboratório de Instrumentação e Física Experimental de Partículas, Coimbra, Portugal
3 shared publications - Brigida Costa Ferreira
Instituto de Biofísica e Engenharia Biomédica (IBEB), Faculdade de Ciências, Universidade de Lisboa
2 shared publications - Caterina Monini
Université Grenoble-Alpes, CNRS/IN2P3
2 shared publications
Latest Publications
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Multiscale modeling for radiation protection and cancer treatment : from nanodosimetry to cell response
Modélisation multi-échelle pour la radioprotection et le traitement du cancer : de la nanodosimétrie à la réponse cellulaire: L'interaction des rayonnements ionisants avec le vivant est marquée par des phénomènes stochastiques importants aussi bien en termes de dosimétrie physique que des effets biologiques induits. Cette thèse aborde trois problématiques de la thérapie et de l'estimation du risque des radiations pour la santé, à l'aide d'outils de modélisation et de simulations Monte Carlo. En effet, des calculs de l'énergie spécifique dans des volumes de différentes tailles ont montré que les amplitudes des fluctuations dépendent fortement de la taille de la cible. Elles sont particulièrement grandes dans le cas des cibles nanométriques. À partir de ces calculs, une étude sur la taille des dosimètres implantables pour le monitorage des traitements de radiothérapie a montré que des dimensions au moins micrométriques sont nécessaires pour assurer des mesures fiables. Les mêmes calculs ont permis l'analyse des effets de faibles doses d'irradiation, notamment la compatibilité de différentes tailles de cibles avec des données expérimentales d'aberrations chromosomiques. Les résultats suggèrent que l'activation du réseau mitochondrial peut être liée au déclenchement de mécanismes de radiorésistance dans les cellules CAL51. Finalement, un nouveau modèle (NanOx) de prédiction de l'efficacité de l'hadronthérapie (radiothérapie par faisceaux d'ions) est présenté et appliqué à la lignée cellulaire V79. Ce modèle est complètement stochastique et intègre les calculs de dosimétrie à plusieurs échelles pour modéliser des effets locaux et non locaux pouvant correspondre respectivement à des lésions de l'ADN et à un stress oxydatif
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Multiscale modeling for radiation protection and cancer treatment : from nanodosimetry to cell response
Modélisation multi-échelle pour la radioprotection et le traitement du cancer : de la nanodosimétrie à la réponse cellulaire: L'interaction des rayonnements ionisants avec le vivant est marquée par des phénomènes stochastiques importants aussi bien en termes de dosimétrie physique que des effets biologiques induits. Cette thèse aborde trois problématiques de la thérapie et de l'estimation du risque des radiations pour la santé, à l'aide d'outils de modélisation et de simulations Monte Carlo. En effet, des calculs de l'énergie spécifique dans des volumes de différentes tailles ont montré que les amplitudes des fluctuations dépendent fortement de la taille de la cible. Elles sont particulièrement grandes dans le cas des cibles nanométriques. À partir de ces calculs, une étude sur la taille des dosimètres implantables pour le monitorage des traitements de radiothérapie a montré que des dimensions au moins micrométriques sont nécessaires pour assurer des mesures fiables. Les mêmes calculs ont permis l'analyse des effets de faibles doses d'irradiation, notamment la compatibilité de différentes tailles de cibles avec des données expérimentales d'aberrations chromosomiques. Les résultats suggèrent que l'activation du réseau mitochondrial peut être liée au déclenchement de mécanismes de radiorésistance dans les cellules CAL51. Finalement, un nouveau modèle (NanOx) de prédiction de l'efficacité de l'hadronthérapie (radiothérapie par faisceaux d'ions) est présenté et appliqué à la lignée cellulaire V79. Ce modèle est complètement stochastique et intègre les calculs de dosimétrie à plusieurs échelles pour modéliser des effets locaux et non locaux pouvant correspondre respectivement à des lésions de l'ADN et à un stress oxydatif
- Open Access
- 7 November 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Cell survival prediction in hadrontherapy with the NanOx biophysical model
Biophysical models are useful tools for predicting the biological effects of ionizing radiation. From a practical point of view, these models can help clinicians to optimize the radiation absorbed dose delivered to patients in particle therapy. The biophysical model NanOx was recently developed to predict cell survival fractions in the context of radiotherapy. The model takes into account the stochastic nature of radiation at different levels and considers as well the accumulation of radio-induced oxidative stress in cells caused by reactive chemical species. We show in this work how the general formalism of NanOx is adapted to hadrontherapy applications. We then use NanOx to compute the cell survival fractions for three cell lines (V79, CHO-K1 and HSG) in response to carbon ions of different energies, and benchmark the predictions against experimental data. The results attest that NanOx provides a good description of both the overkill effect and the evolution of the shoulders of cell survival curves with linear energy transfer.
- 7 November 2022
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 10
Open AccessCell survival prediction in hadrontherapy with the NanOx biophysical model
Biophysical models are useful tools for predicting the biological effects of ionizing radiation. From a practical point of view, these models can help clinicians to optimize the radiation absorbed dose delivered to patients in particle therapy. The biophysical model NanOx was recently developed to predict cell survival fractions in the context of radiotherapy. The model takes into account the stochastic nature of radiation at different levels and considers as well the accumulation of radio-induced oxidative stress in cells caused by reactive chemical species. We show in this work how the general formalism of NanOx is adapted to hadrontherapy applications. We then use NanOx to compute the cell survival fractions for three cell lines (V79, CHO-K1 and HSG) in response to carbon ions of different energies, and benchmark the predictions against experimental data. The results attest that NanOx provides a good description of both the overkill effect and the evolution of the shoulders of cell survival curves with linear energy transfer.
- Open Access
Study of the Influence of NanOx Parameters
NanOx is a new biophysical model that aims at predicting the biological effect of ions in the context of hadron therapy. It integrates the fully-stochastic nature of ionizing radiation both at micrometric and nanometric scales and also takes into account the production and diffusion of reactive chemical species. In order to further characterize the new framework, we discuss the meaning and relevance of most of the NanOx parameters by evaluating their influence on the linear-quadratic coefficient and on the dose deposited to achieve 10% or 1% of cell survival, or , as a function of LET. We perform a theoretical study in which variations in the input parameters are propagated into the model predictions for HSG, V79 and CHO-K1 cells irradiated by monoenergetic protons and carbon ions. We conclude that, in the current version of NanOx, the modeling of a specific cell line relies on five parameters, which have to be adjusted to several experimental measurements: the average cellular nuclear radius, the linear-quadratic coefficients describing photon irradiations and the values associated with two carbon ions of intermediate and high-LET values. This may have interesting implications toward a clinical application of the new biophysical model.Open AccessStudy of the Influence of NanOx Parameters
NanOx is a new biophysical model that aims at predicting the biological effect of ions in the context of hadron therapy. It integrates the fully-stochastic nature of ionizing radiation both at micrometric and nanometric scales and also takes into account the production and diffusion of reactive chemical species. In order to further characterize the new framework, we discuss the meaning and relevance of most of the NanOx parameters by evaluating their influence on the linear-quadratic coefficient and on the dose deposited to achieve 10% or 1% of cell survival, or , as a function of LET. We perform a theoretical study in which variations in the input parameters are propagated into the model predictions for HSG, V79 and CHO-K1 cells irradiated by monoenergetic protons and carbon ions. We conclude that, in the current version of NanOx, the modeling of a specific cell line relies on five parameters, which have to be adjusted to several experimental measurements: the average cellular nuclear radius, the linear-quadratic coefficients describing photon irradiations and the values associated with two carbon ions of intermediate and high-LET values. This may have interesting implications toward a clinical application of the new biophysical model. - 20 November 2017
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 94 (1) , 54-61
Relationship between radioadaptive response and individual radiosensitivity to low doses of gamma radiation: an extended study of chromosome damage in blood lymphocytes of three donors
Purpose: Our study aimed at evaluating: 1) whether well-established variability in radioadaptive response (AR) in various donor blood lymphocytes might be attributed to inter-individual differences in radiosensitivity to different low dose levels; 2) whether AR is reproducibly present over time in the lymphocytes of AR-positive individuals. Experimental procedure: Whole blood samples of three donors were exposed to low doses (2–30 cGy) of γ-radiation alone (G0 phase) or followed by a 1 Gy challenge dose (late S/early G2 phase), and chromosome aberration were scored to assess the dose-response relationship and adaptive response, correspondingly. Three experiments were performed on blood samples of the same donors at six month intervals. Results: Significant differences in dose response relationship for blood lymphocytes were found among individuals. In most cases, the donors exhibited initial low-dose hypersensitivity (HRS) followed by an increase in radioresistance (IRR). AR could be successfully induced by some particular priming doses in the lymphocytes of each donor; however, the doses resulting in a protective response were quite different for all three donors. These protective doses could equally belong to either HRS or IRR region on the individual dose-response curves. In most cases, no clear AR outcome dependence on the priming dose was found at all. Moreover, pre-exposure to the same low dose could result in opposite effects in the lymphocytes of the same donor in different experiments. Conclusions: AR variability in human lymphocytes is not attributed to variation in radiosensitivity among individuals and is more drastic than was believed. It seems doubtful that AR is a universal phenomenon which has a consistent impact on the effects of radiation exposure on humans.
- 20 November 2017
- Published by Taylor & Francis in International Journal of Radiation Biology
- Vol. 94 (1) , 54-61
Relationship between radioadaptive response and individual radiosensitivity to low doses of gamma radiation: an extended study of chromosome damage in blood lymphocytes of three donors
Purpose: Our study aimed at evaluating: 1) whether well-established variability in radioadaptive response (AR) in various donor blood lymphocytes might be attributed to inter-individual differences in radiosensitivity to different low dose levels; 2) whether AR is reproducibly present over time in the lymphocytes of AR-positive individuals. Experimental procedure: Whole blood samples of three donors were exposed to low doses (2–30 cGy) of γ-radiation alone (G0 phase) or followed by a 1 Gy challenge dose (late S/early G2 phase), and chromosome aberration were scored to assess the dose-response relationship and adaptive response, correspondingly. Three experiments were performed on blood samples of the same donors at six month intervals. Results: Significant differences in dose response relationship for blood lymphocytes were found among individuals. In most cases, the donors exhibited initial low-dose hypersensitivity (HRS) followed by an increase in radioresistance (IRR). AR could be successfully induced by some particular priming doses in the lymphocytes of each donor; however, the doses resulting in a protective response were quite different for all three donors. These protective doses could equally belong to either HRS or IRR region on the individual dose-response curves. In most cases, no clear AR outcome dependence on the priming dose was found at all. Moreover, pre-exposure to the same low dose could result in opposite effects in the lymphocytes of the same donor in different experiments. Conclusions: AR variability in human lymphocytes is not attributed to variation in radiosensitivity among individuals and is more drastic than was believed. It seems doubtful that AR is a universal phenomenon which has a consistent impact on the effects of radiation exposure on humans.
- 23 January 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (4) , 1248-1268
NanOx, a new model to predict cell survival in the context of particle therapy
Particle therapy is increasingly attractive for the treatment of tumors and the number of facilities offering it is rising worldwide. Due to the well-known enhanced effectiveness of ions, it is of utmost importance to plan treatments with great care to ensure tumor killing and healthy tissues sparing. Hence, the accurate quantification of the relative biological effectiveness (RBE) of ions, used in the calculation of the biological dose, is critical. Nevertheless, the RBE is a complex function of many parameters and its determination requires modeling. The approaches currently used have allowed particle therapy to thrive, but still show some shortcomings. We present herein a short description of a new theoretical framework, NanOx, to calculate cell survival in the context of particle therapy. It gathers principles from existing approaches, while addressing some of their weaknesses. NanOx is a multiscale model that takes the stochastic nature of radiation at nanometric and micrometric scales fully into account, integrating also the chemical aspects of radiation-matter interaction. The latter are included in the model by means of a chemical specific energy, determined from the production of reactive chemical species induced by irradiation. Such a production represents the accumulation of oxidative stress and sublethal damage in the cell, potentially generating non-local lethal events in NanOx. The complementary local lethal events occur in a very localized region and can, alone, lead to cell death. Both these classes of events contribute to cell death. The comparison between experimental data and model predictions for the V79 cell line show a good agreement. In particular, the dependence of the typical shoulders of cell survival curves on linear energy transfer are well described, but also the effectiveness of different ions, including the overkill effect. These results required the adjustment of a number of parameters compatible with the application of the model in a clinical scenario thereby showing the potential of NanOx. Said parameters are discussed in detail in this paper.
- 23 January 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (4) , 1248-1268
NanOx, a new model to predict cell survival in the context of particle therapy
Particle therapy is increasingly attractive for the treatment of tumors and the number of facilities offering it is rising worldwide. Due to the well-known enhanced effectiveness of ions, it is of utmost importance to plan treatments with great care to ensure tumor killing and healthy tissues sparing. Hence, the accurate quantification of the relative biological effectiveness (RBE) of ions, used in the calculation of the biological dose, is critical. Nevertheless, the RBE is a complex function of many parameters and its determination requires modeling. The approaches currently used have allowed particle therapy to thrive, but still show some shortcomings. We present herein a short description of a new theoretical framework, NanOx, to calculate cell survival in the context of particle therapy. It gathers principles from existing approaches, while addressing some of their weaknesses. NanOx is a multiscale model that takes the stochastic nature of radiation at nanometric and micrometric scales fully into account, integrating also the chemical aspects of radiation-matter interaction. The latter are included in the model by means of a chemical specific energy, determined from the production of reactive chemical species induced by irradiation. Such a production represents the accumulation of oxidative stress and sublethal damage in the cell, potentially generating non-local lethal events in NanOx. The complementary local lethal events occur in a very localized region and can, alone, lead to cell death. Both these classes of events contribute to cell death. The comparison between experimental data and model predictions for the V79 cell line show a good agreement. In particular, the dependence of the typical shoulders of cell survival curves on linear energy transfer are well described, but also the effectiveness of different ions, including the overkill effect. These results required the adjustment of a number of parameters compatible with the application of the model in a clinical scenario thereby showing the potential of NanOx. Said parameters are discussed in detail in this paper.
- 26 December 2015
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 55 (1) , 31-40
Modeling cell response to low doses of photon irradiation: Part 2—application to radiation-induced chromosomal aberrations in human carcinoma cells
The biological phenomena observed at low doses of ionizing radiation (adaptive response, bystander effects, genomic instability, etc.) are still not well understood. While at high irradiation doses, cellular death may be directly linked to DNA damage, at low doses, other cellular structures may be involved in what are known as non-(DNA)-targeted effects. Mitochondria, in particular, may play a crucial role through their participation in a signaling network involving oxygen/nitrogen radical species. According to the size of the implicated organelles, the fluctuations in the energy deposited into these target structures may impact considerably the response of cells to low doses of ionizing irradiation. Based on a recent simulation of these fluctuations, a theoretical framework was established to have further insight into cell responses to low doses of photon irradiation, namely the triggering of radioresistance mechanisms by energy deposition into specific targets. Three versions of a model are considered depending on the target size and on the number of targets that need to be activated by energy deposition to trigger radioresistance mechanisms. These model versions are applied to the fraction of radiation-induced chromosomal aberrations measured at low doses in human carcinoma cells (CAL51). For this cell line, it was found in the present study that the mechanisms of radioresistance could not be triggered by the activation of a single small target (nanometric size, 100 nm), but could instead be triggered by the activation of a large target (micrometric, \({10}\,\upmu \hbox {m}\)) or by the activation of a great number of small targets. The mitochondria network, viewed either as a large target or as a set of small units, might be concerned by these low-dose effects.- 26 December 2015
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 55 (1) , 31-40
Modeling cell response to low doses of photon irradiation: Part 2—application to radiation-induced chromosomal aberrations in human carcinoma cells
The biological phenomena observed at low doses of ionizing radiation (adaptive response, bystander effects, genomic instability, etc.) are still not well understood. While at high irradiation doses, cellular death may be directly linked to DNA damage, at low doses, other cellular structures may be involved in what are known as non-(DNA)-targeted effects. Mitochondria, in particular, may play a crucial role through their participation in a signaling network involving oxygen/nitrogen radical species. According to the size of the implicated organelles, the fluctuations in the energy deposited into these target structures may impact considerably the response of cells to low doses of ionizing irradiation. Based on a recent simulation of these fluctuations, a theoretical framework was established to have further insight into cell responses to low doses of photon irradiation, namely the triggering of radioresistance mechanisms by energy deposition into specific targets. Three versions of a model are considered depending on the target size and on the number of targets that need to be activated by energy deposition to trigger radioresistance mechanisms. These model versions are applied to the fraction of radiation-induced chromosomal aberrations measured at low doses in human carcinoma cells (CAL51). For this cell line, it was found in the present study that the mechanisms of radioresistance could not be triggered by the activation of a single small target (nanometric size, 100 nm), but could instead be triggered by the activation of a large target (micrometric, \({10}\,\upmu \hbox {m}\)) or by the activation of a great number of small targets. The mitochondria network, viewed either as a large target or as a set of small units, might be concerned by these low-dose effects.- 20 November 2015
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 55 (1) , 19-30
Modeling cell response to low doses of photon irradiation—Part 1: on the origin of fluctuations
Intra- and inter-individual variability is a well-known aspect of biological responses of cells observed at low doses of radiation, whichever the phenomenon considered (adaptive response, bystander effects, genomic instability, etc.). There is growing evidence that low-dose phenomena are related to cell mechanisms other than DNA damage and misrepair, meaning that other cellular structures may play a crucial role. Therefore, in this study, a series of calculations at low doses was carried out to study the distribution of specific energies from different irradiation doses (3, 10 and 30 cGy) in targets of different sizes (0.1, 1 and \(10\, \upmu \hbox {m}\)) corresponding to the dimensions of different cell structures. The results obtained show a strong dependence of the probability distributions of specific energies on the target size: targets with dimensions comparable to those of the cell show a Gaussian-like distribution, whereas very small targets are very likely to not be hit. A statistical analysis showed that the level of fluctuations in the fraction of aberrant cells is only related to the fraction of aberrant cells and the number of irradiated cells, regardless of, for instance, the heterogeneity in cell response.- 20 November 2015
- Published by Springer Nature in Radiation and Environmental Biophysics
- Vol. 55 (1) , 19-30
Modeling cell response to low doses of photon irradiation—Part 1: on the origin of fluctuations
Intra- and inter-individual variability is a well-known aspect of biological responses of cells observed at low doses of radiation, whichever the phenomenon considered (adaptive response, bystander effects, genomic instability, etc.). There is growing evidence that low-dose phenomena are related to cell mechanisms other than DNA damage and misrepair, meaning that other cellular structures may play a crucial role. Therefore, in this study, a series of calculations at low doses was carried out to study the distribution of specific energies from different irradiation doses (3, 10 and 30 cGy) in targets of different sizes (0.1, 1 and \(10\, \upmu \hbox {m}\)) corresponding to the dimensions of different cell structures. The results obtained show a strong dependence of the probability distributions of specific energies on the target size: targets with dimensions comparable to those of the cell show a Gaussian-like distribution, whereas very small targets are very likely to not be hit. A statistical analysis showed that the level of fluctuations in the fraction of aberrant cells is only related to the fraction of aberrant cells and the number of irradiated cells, regardless of, for instance, the heterogeneity in cell response.- 1 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Preliminary characterization of the external proton beam from a PET cyclotron for use in neutron and proton radiobiology and other dosimetric studies
Different cyclotron models capable of accelerating protons up to 20MeV have been worldwide installed. Although their purpose is mainly positron emission tomography (PET) radioisotope production, they are equipped with several beam lines suitable for scientific research. Each beam line may typically deliver proton currents up to 150 μA (1×10 15 particles/s). Radiobiological and dosimetric studies can be performed using these beam lines, which may contribute to further improve ion therapy and material radiation hardness results, among other applications. We report experimental results aiming at characterizing the proton beam achievable outside a PET cyclotron. In addition, we simulate this experimental setup by using Geant4. We show that simulation is consistent with previous published experimental data and with our first-measured results. These point to a beam angular spreading which may be utilized to establish an irradiation setup within the bunker. We estimate that the dose achievable with such setup may span 4-orders-of-magnitude, useful in radiobiology, ranging from 10mGy to 100 Gy. Finally, we show by simulation that neutron and γ-ray dose on a realistic, in-bunker target is negligible down to at most the 1% level. Further quantification for lower levels is ongoing.
- 1 February 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Preliminary characterization of the external proton beam from a PET cyclotron for use in neutron and proton radiobiology and other dosimetric studies
Different cyclotron models capable of accelerating protons up to 20MeV have been worldwide installed. Although their purpose is mainly positron emission tomography (PET) radioisotope production, they are equipped with several beam lines suitable for scientific research. Each beam line may typically deliver proton currents up to 150 μA (1×10 15 particles/s). Radiobiological and dosimetric studies can be performed using these beam lines, which may contribute to further improve ion therapy and material radiation hardness results, among other applications. We report experimental results aiming at characterizing the proton beam achievable outside a PET cyclotron. In addition, we simulate this experimental setup by using Geant4. We show that simulation is consistent with previous published experimental data and with our first-measured results. These point to a beam angular spreading which may be utilized to establish an irradiation setup within the bunker. We estimate that the dose achievable with such setup may span 4-orders-of-magnitude, useful in radiobiology, ranging from 10mGy to 100 Gy. Finally, we show by simulation that neutron and γ-ray dose on a realistic, in-bunker target is negligible down to at most the 1% level. Further quantification for lower levels is ongoing.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 4296-4302
Dose-free monitoring of radiotherapy treatments with scattered photons: First experimental results at a 6-MV Linac
Radiotherapy (RT) is nowadays, after surgery, among the most commonly used treatment regarding cancer. For predicted clinical outcomes it is of importance assuring that the treatment plan is correctly delivered without dose deviations, namely target underdosage and/or organ-at-risk overdosage. For that, a new multi-pixel imaging technique for real-time dose verification during photon RT has been proposed (RTmon). First scanned, single-pixel experimental results are presented here. The principle of operation of RTmon relies on the detection of scattered photons emitted perpendicularly to the beam direction. The first experimental results were obtained with a collimated γ-ray detector operated under a 6-MV clinical linac beam. A large contaminating background originating from the head of the linac was found. We show that its mitigation is possible by (1) using appropriate shielding, (2) decreasing the scintillator volume pointing towards out-of-field, background-prone regions, and (3) optimizing the collimation by means of detector positioning and differential signal sampling. Simulation and experimental data showed that multiple scattering inside a phantom target constitutes an additional source of background that increases along the beam direction due to momentum conservation in collisions between the incoming photons and target electrons. This second source of background can be reduced effectively by optimizing the distance between the collimated detector and the beam axis, at the expense of decreased collimation sensitivity. Despite the harsh therapeutic irradiation conditions, background and noise suppression by appropriate shielding and differential signal sampling renders the scanned experimental results quite similar to those obtained by means of Geant4 simulations. Such experimental results suggest therefore that this detector system may be useful for real-time dose verification in external X-ray radiotherapy.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 4296-4302
Dose-free monitoring of radiotherapy treatments with scattered photons: First experimental results at a 6-MV Linac
Radiotherapy (RT) is nowadays, after surgery, among the most commonly used treatment regarding cancer. For predicted clinical outcomes it is of importance assuring that the treatment plan is correctly delivered without dose deviations, namely target underdosage and/or organ-at-risk overdosage. For that, a new multi-pixel imaging technique for real-time dose verification during photon RT has been proposed (RTmon). First scanned, single-pixel experimental results are presented here. The principle of operation of RTmon relies on the detection of scattered photons emitted perpendicularly to the beam direction. The first experimental results were obtained with a collimated γ-ray detector operated under a 6-MV clinical linac beam. A large contaminating background originating from the head of the linac was found. We show that its mitigation is possible by (1) using appropriate shielding, (2) decreasing the scintillator volume pointing towards out-of-field, background-prone regions, and (3) optimizing the collimation by means of detector positioning and differential signal sampling. Simulation and experimental data showed that multiple scattering inside a phantom target constitutes an additional source of background that increases along the beam direction due to momentum conservation in collisions between the incoming photons and target electrons. This second source of background can be reduced effectively by optimizing the distance between the collimated detector and the beam axis, at the expense of decreased collimation sensitivity. Despite the harsh therapeutic irradiation conditions, background and noise suppression by appropriate shielding and differential signal sampling renders the scanned experimental results quite similar to those obtained by means of Geant4 simulations. Such experimental results suggest therefore that this detector system may be useful for real-time dose verification in external X-ray radiotherapy.