TKTakahiro Konishi

Takahiro Konishi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Takahiro Konishi has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Validation of Simplified Renal Dosimetry Protocols for 177Lu-DOTATATE Therapy Using the IDAC-dose Software

    by Anji Yokouchi, Takayuki Shibutani, Takahiro Konishi, Hiroto Yoneyama, Hajime Ichikawa, Hiroshi Wakabayashi

    Validation of Simplified Renal Dosimetry Protocols for 177Lu-DOTATATE Therapy Using the IDAC-dose Software - Molecular Imaging and Radionuclide Therapy


  • Metal artifact reduction for improving quantitative SPECT/CT imaging

    by Takahiro Konishi, Takayuki Shibutani, Koichi Okuda, Hiroto Yoneyama, Riku Moribe, Masahisa Onoguchi, Kenichi Nakajima, Seigo Kinuya

    Objective This study aimed to evaluate the effect of the metal artifact reduction (MAR) method on quantitative single-photon emission computed tomography (SPECT)/computed tomography (CT) to reveal the usefulness of MAR in patients with metal implants. Methods We performed a phantom experiment simulating patients with artificial hip prostheses using SPECT/CT equipped with the iterative MAR (iMAR). The phantom was filled with Tc-99m solution (29.5 kBq/mL). For the CT scan conditions, tube current time products were applied to obtain volume CT dose indexes (CTDIvols) of 1.4, 2.8, and 5.6 mGy. Six types of quantitative SPECT images were reconstructed using data from different doses of CT processed with and without iMAR for CT attenuation correction. Thirty circular regions of interest (ROIs) were placed in each of the dark-band artifact areas, the white-streak artifact areas, and the non-artifact areas. We calculated radioactivity concentrations from quantitative SPECT images with and without iMAR to evaluate the quantitative accuracy. The differences of the effect of iMAR with different CT doses were also evaluated. Results The results obtained using CT data with a CTDIvol of 2.8 mGy are described below. For quantitative SPECT data without iMAR, we observed the underestimation of radioactivity concentration in the dark-band artifact areas and overestimation in the white-streak artifact areas. We observed quantification errors ranging from − 41.1% to + 20.0% without iMAR, depending on the ROI localization. When iMAR was used, these errors were reduced to a range of − 22.8% to + 14.2%. The mean absolute error from the true value in the artifact regions was also significantly reduced from 4.00 to 1.74 kBq/mL. In the non-artifact areas, the radioactivity concentrations obtained from the quantitative SPECT data with and without iMAR were equivalent to the true value and did not differ significantly between the two conditions. Similar results were observed for procedures with CTDIvols of 1.4 and 5.6 mGy. Conclusions This study indicated that iMAR could improve the quantitative accuracy of SPECT/CT independent of the CT dose. iMAR can serve as a practicable technique for quantitative SPECT/CT in patients with metal implants.


  • Open Access

    Ability of artificial intelligence to diagnose coronary artery stenosis using hybrid images of coronary computed tomography angiography and myocardial perfusion SPECT

    by Hiroto Yoneyama, Kenichi Nakajima, Junichi Taki, Hiroshi Wakabayashi, Shinro Matsuo, Takahiro Konishi, Koichi Okuda, Takayuki Shibutani, Masahisa Onoguchi, Seigo Kinuya

    Detecting culprit coronary arteries in patients with ischemia using only myocardial perfusion single-photon emission computed tomography (SPECT) can be challenging. This study aimed to improve the detection of culprit regions using an artificial neural network (ANN) to analyze hybrid images of coronary computed tomography angiography (CCTA) and myocardial perfusion SPECT. This study enrolled 59 patients with stable coronary artery disease (CAD) who had been assessed by coronary angiography within 60 days of myocardial perfusion SPECT. Two nuclear medicine physicians interpreted the myocardial perfusion SPECT and hybrid images with four grades of confidence, then drew regions on polar maps to identify culprit coronary arteries. The gold standard was determined by the consensus of two other nuclear cardiology specialist based on coronary angiography findings and clinical information. The ability to detect culprit coronary arteries was compared among experienced nuclear cardiologists and the ANN. Receiver operating characteristics (ROC) curves were analyzed and areas under the ROC curves (AUC) were determined. Using hybrid images, observer A detected CAD in the right (RCA), left anterior descending (LAD), and left circumflex (LCX) coronary arteries with 83.6%, 89.3%, and 94.4% accuracy, respectively and observer B did so with 72.9%, 84.2%, and 89.3%, respectively. The ANN was 79.1%, 89.8%, and 89.3% accurate for each coronary artery. Diagnostic accuracy was comparable between the ANN and experienced nuclear medicine physicians. The AUC was significantly improved using hybrid images in the RCA region (observer A: from 0.715 to 0.835, p = 0.0031; observer B: from 0.771 to 0.843, p = 0.042). To detect culprit coronary arteries in perfusion defects of the inferior wall without using hybrid images was problematic because the perfused areas of the LCX and RCA varied among individuals. Hybrid images of CCTA and myocardial perfusion SPECT are useful for detecting culprit coronary arteries. Diagnoses using artificial intelligence are comparable to that by nuclear medicine physicians.


  • IQ-SPECT for thallium-201 myocardial perfusion imaging: effect of normal databases on quantification

    by Takahiro Konishi, Kenichi Nakajima, Koichi Okuda, Hiroto Yoneyama, Shinro Matsuo, Takayuki Shibutani, Masahisa Onoguchi, Seigo Kinuya

    Although IQ-single-photon emission computed tomography (SPECT) provides rapid acquisition and attenuation-corrected images, the unique technology may create characteristic distribution different from the conventional imaging. This study aimed to compare the diagnostic performance of IQ-SPECT using Japanese normal databases (NDBs) with that of the conventional SPECT for thallium-201 (201Tl) myocardial perfusion imaging (MPI).


  • Open Access

    Organ Atrophy Induced by Sorafenib and Sunitinib – Quantitative Computed Tomography (CT) Evaluation of the Pancreas, Thyroid Gland and Spleen

    by Hiroaki Takahashi, Katsuhiro Nasu, Manabu Minami, Takahiro Kojima, Hiroyuki Nishiyama, Toshitaka Ishiguro, Takahiro Konishi

    BACKGROUND:To evaluate organ atrophy induced by sorafenib and sunitinib, we retrospectively reviewed the CT scans of renal cell carcinoma (RCC) patients receiving molecular targeted therapy (MTT) using sorafenib or sunitinib, and performed volumetric...