Chengwei Fan
Chengwei Fan has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Gang Chen
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
3 shared publications Yufei Teng
State Grid Sichuan Electric Power Research Institute, Chengdu, China
3 shared publications- Zhen Chen
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
3 shared publications - Baorui Chen
State Grid Sichuan Electric Power Research Institute, Chengdu 610041, China
2 shared publications - Deqiang Gan
Zhejiang University
2 shared publications Gang Chen
State Grid Sichuan Electric Power Research Institute Chengdu China
2 shared publications
Latest Publications
- Open Access
- 26 March 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (7) , 3638
A New Method for Constructing the Static-Voltage-Stability Boundary with a Conversion Strategy
The static-voltage-stability region (SVSR) is an effective tool for monitoring the safe operation of grid voltage. Rapidly obtaining the static-voltage-stability-region boundary (SVSRB) of a power system is crucial for the application of SVSR technology. First, this paper reveals the mechanisms underlying the failure scenarios that may occur with conventional boundary tracking methods. Then, an improved method incorporating curve extrapolation and correction conversion strategies is proposed, which enhances the efficiency of constructing the SVSRB. Furthermore, the analytical expression of the SVSRB is derived from the intermediate information obtained during the predictor stage. Finally, simulation examples based on a simple power system, the IEEE 3-machine, 9-bus power system and IEEE 300-bus power system were developed to verify the accuracy and efficiency of the proposed method.
- 26 March 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (7) , 3638
Open AccessA New Method for Constructing the Static-Voltage-Stability Boundary with a Conversion Strategy
The static-voltage-stability region (SVSR) is an effective tool for monitoring the safe operation of grid voltage. Rapidly obtaining the static-voltage-stability-region boundary (SVSRB) of a power system is crucial for the application of SVSR technology. First, this paper reveals the mechanisms underlying the failure scenarios that may occur with conventional boundary tracking methods. Then, an improved method incorporating curve extrapolation and correction conversion strategies is proposed, which enhances the efficiency of constructing the SVSRB. Furthermore, the analytical expression of the SVSRB is derived from the intermediate information obtained during the predictor stage. Finally, simulation examples based on a simple power system, the IEEE 3-machine, 9-bus power system and IEEE 300-bus power system were developed to verify the accuracy and efficiency of the proposed method.
- Open Access
Inverse Characteristic Locus Method for Power System Low-Frequency Oscillation Control and Optimal Design
Recent results indicate that the characteristic locus method provides a convenient approach for analyzing power system low-frequency stability. In this study, an enhanced version of the method, referred to as the inverse characteristic locus method, is introduced. By inverting the similarity matrix of the loop transfer function matrix of the system, a more reliable and accurate stability metric is obtained. The proposed method is applied to assess the impact of changes in wind turbine generator (WTG) dynamics and system operating conditions on stability. Simulation results demonstrate that variations in system operating conditions exert a greater influence on stability compared to changes in WTG dynamics.
Open AccessInverse Characteristic Locus Method for Power System Low-Frequency Oscillation Control and Optimal Design
Recent results indicate that the characteristic locus method provides a convenient approach for analyzing power system low-frequency stability. In this study, an enhanced version of the method, referred to as the inverse characteristic locus method, is introduced. By inverting the similarity matrix of the loop transfer function matrix of the system, a more reliable and accurate stability metric is obtained. The proposed method is applied to assess the impact of changes in wind turbine generator (WTG) dynamics and system operating conditions on stability. Simulation results demonstrate that variations in system operating conditions exert a greater influence on stability compared to changes in WTG dynamics.
- Open Access
- 23 July 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2238-2247
An optimizated additional damping control for suppressing ultra‐low frequency oscillation suppression based on SVC
The ultra‐low frequency oscillation (ULFO) imposes an emerging stability challenge to the high proportion of hydropower grids. To suppress ULFO without reducing the primary frequency regulation of the hydro governor, a novel idea to exploit the voltage regulation effect of load is implemented. First, the additional damping controller is designed and configured in static var compensator (SVC), and the frequency analysis model considering the configuration of SVC as well as damping controller is established. Based on the model, the specific influence of SVC and controller on ULFO is analysed through eigenvalue calculation. In addition, the influence of various load models and SVC location on the damping level are further studied. Consequently, a parameter optimization design method for SVC additional damping control is proposed, it is modelled as the optimization problem of damping ratio in ULFO mode under multi‐operation conditions, which is solved by a particle swarm optimization algorithm. Finally, the effectiveness of the designed SVC additional damping controller is verified in the improved four‐machine two‐area power system and the actual power grid in China.
- 23 July 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (14) , 2238-2247
Open AccessAn optimizated additional damping control for suppressing ultra‐low frequency oscillation suppression based on SVC
The ultra‐low frequency oscillation (ULFO) imposes an emerging stability challenge to the high proportion of hydropower grids. To suppress ULFO without reducing the primary frequency regulation of the hydro governor, a novel idea to exploit the voltage regulation effect of load is implemented. First, the additional damping controller is designed and configured in static var compensator (SVC), and the frequency analysis model considering the configuration of SVC as well as damping controller is established. Based on the model, the specific influence of SVC and controller on ULFO is analysed through eigenvalue calculation. In addition, the influence of various load models and SVC location on the damping level are further studied. Consequently, a parameter optimization design method for SVC additional damping control is proposed, it is modelled as the optimization problem of damping ratio in ULFO mode under multi‐operation conditions, which is solved by a particle swarm optimization algorithm. Finally, the effectiveness of the designed SVC additional damping controller is verified in the improved four‐machine two‐area power system and the actual power grid in China.
- Open Access
- 7 September 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (18) , 7316
Research on Damping Control Index of Ultra-Low-Frequency Oscillation in Hydro-Dominant Power Systems
In recent years, ultra-low-frequency oscillation (ULFO) is a prominent problem in power systems of dominant hydropower. In order to suppress ULFO, the most effective strategy is the governor parameters optimization to improve the system damping within the ultra-low-frequency band. However, no explicit standard has been established to stipulate the level of system damping for ULFO suppression. In this paper, the key factors that affect the amplitude and damping of ULFO are firstly analyzed. Then, the design principle of the damping control index of ULFO is put forward. According to it, a damping control index is proposed. After that, a case of ULFO in an actual power system proves the rationality of the proposed index. Finally, the application of the index in the Southwest China Power Grid illustrates its effectiveness and feasibility.
- 7 September 2020
- Published by MDPI AG in Sustainability
- Vol. 12 (18) , 7316
Open AccessResearch on Damping Control Index of Ultra-Low-Frequency Oscillation in Hydro-Dominant Power Systems
In recent years, ultra-low-frequency oscillation (ULFO) is a prominent problem in power systems of dominant hydropower. In order to suppress ULFO, the most effective strategy is the governor parameters optimization to improve the system damping within the ultra-low-frequency band. However, no explicit standard has been established to stipulate the level of system damping for ULFO suppression. In this paper, the key factors that affect the amplitude and damping of ULFO are firstly analyzed. Then, the design principle of the damping control index of ULFO is put forward. According to it, a damping control index is proposed. After that, a case of ULFO in an actual power system proves the rationality of the proposed index. Finally, the application of the index in the Southwest China Power Grid illustrates its effectiveness and feasibility.
- Open Access
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 88085-88092
Frequency Oscillation Analysis of Power System With Multiple Governor Deadbands
In recent years, the ultra-low frequency oscillation of power system is one of the most concerned frequency stability problem. The governor deadband are considered as one of the main influences. However, the existing methods can only deal with single deadband segment. As for a multi-machine system with multiple deadband segments, it lacks the analysis method for frequency oscillation. To solve this problem, this paper first define the extended description function applied to nonlinear composite system according to the principle of traditional description function method. The extended description function can quantify the relationship of input and output of a system with multiple nonlinear segments. Then, based on the uniform frequency model of multiple governors, the turbines and governors of hydro and thermal power units with different deadband widths are equivalent to one extended description function. The locus of minus reciprocal of the extended description function with oscillation amplitude and the Nyquist curve of the generator are plotted on the complex plane for the analysis of system stability. Next, the critical oscillation amplitude of disturbance to trigger the system frequency oscillation is calculated according to the point of intersection of both curves. Finally, the simulation results show that the critical oscillation amplitude can reflect the stability of system. The change of deadband width is positively correlated with the critical oscillation amplitude. The appropriate setting of deadband and configuration of hydro-thermal generation are effective measures to suppress the ultra-low frequency oscillation while retain the ability of frequency regulation.
- 7 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 88085-88092
Open AccessFrequency Oscillation Analysis of Power System With Multiple Governor Deadbands
In recent years, the ultra-low frequency oscillation of power system is one of the most concerned frequency stability problem. The governor deadband are considered as one of the main influences. However, the existing methods can only deal with single deadband segment. As for a multi-machine system with multiple deadband segments, it lacks the analysis method for frequency oscillation. To solve this problem, this paper first define the extended description function applied to nonlinear composite system according to the principle of traditional description function method. The extended description function can quantify the relationship of input and output of a system with multiple nonlinear segments. Then, based on the uniform frequency model of multiple governors, the turbines and governors of hydro and thermal power units with different deadband widths are equivalent to one extended description function. The locus of minus reciprocal of the extended description function with oscillation amplitude and the Nyquist curve of the generator are plotted on the complex plane for the analysis of system stability. Next, the critical oscillation amplitude of disturbance to trigger the system frequency oscillation is calculated according to the point of intersection of both curves. Finally, the simulation results show that the critical oscillation amplitude can reflect the stability of system. The change of deadband width is positively correlated with the critical oscillation amplitude. The appropriate setting of deadband and configuration of hydro-thermal generation are effective measures to suppress the ultra-low frequency oscillation while retain the ability of frequency regulation.
- Open Access
- 10 October 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (20) , 4216
A Data Segmentation-Based Ensemble Classification Method for Power System Transient Stability Status Prediction with Imbalanced Data
In recent years, machine learning methods have shown the great potential for real-time transient stability status prediction (TSSP) application. However, most existing studies overlook the imbalanced data problem in TSSP. To address this issue, a novel data segmentation-based ensemble classification (DSEC) method for TSSP is proposed in this paper. Firstly, the effects of the imbalanced data problem on the decision boundary and classification performance of TSSP are investigated in detail. Then, a three-step DSEC method is presented. In the first step, the data segmentation strategy is utilized for dividing the stable samples into multiple non-overlapping stable subsets, ensuring that the samples in each stable subset are not more than the unstable ones, then each stable subset is combined with the unstable set into a training subset. For the second step, an AdaBoost classifier is built based on each training subset. In the final step, decision values from each AdaBoost classifier are aggregated for determining the transient stability status. The experiments are conducted on the Northeast Power Coordinating Council 140-bus system and the simulation results indicate that the proposed approach can significantly improve the classification performance of TSSP with imbalanced data.
- 10 October 2019
- Published by MDPI AG in Applied Sciences
- Vol. 9 (20) , 4216
Open AccessA Data Segmentation-Based Ensemble Classification Method for Power System Transient Stability Status Prediction with Imbalanced Data
In recent years, machine learning methods have shown the great potential for real-time transient stability status prediction (TSSP) application. However, most existing studies overlook the imbalanced data problem in TSSP. To address this issue, a novel data segmentation-based ensemble classification (DSEC) method for TSSP is proposed in this paper. Firstly, the effects of the imbalanced data problem on the decision boundary and classification performance of TSSP are investigated in detail. Then, a three-step DSEC method is presented. In the first step, the data segmentation strategy is utilized for dividing the stable samples into multiple non-overlapping stable subsets, ensuring that the samples in each stable subset are not more than the unstable ones, then each stable subset is combined with the unstable set into a training subset. For the second step, an AdaBoost classifier is built based on each training subset. In the final step, decision values from each AdaBoost classifier are aggregated for determining the transient stability status. The experiments are conducted on the Northeast Power Coordinating Council 140-bus system and the simulation results indicate that the proposed approach can significantly improve the classification performance of TSSP with imbalanced data.
- 10 September 2019
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (2)
Solution of dynamic power flow technique considering governor nonlinearity
An improved dynamic power flow (DPF) model considering governor nonlinearity is presented. The proposed DPF model is intended for the analysis of post‐contingency power flow after primary frequency regulation. During the regulation process, the governors play an important role while it is difficult to involve the nonlinear segments in the static method. So in this paper, the governor model with amplitude‐limit and deadband is simplified and included in DPF model. Using the describing function method, the effect of deadband is equivalent to an increment of regulation coefficient. The amplitude‐limit is handled by iterative correction. Applying the algorithm to a three‐node system, a case study of load variation proves the effectiveness of the algorithm. Simulations on a practical grid in southern China further demonstrates the practicability and applicability. The algorithm enhances the accuracy of post‐contingency power flow analysis and provides effective analysis for the static security of power system.
- 10 September 2019
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 30 (2)
Solution of dynamic power flow technique considering governor nonlinearity
An improved dynamic power flow (DPF) model considering governor nonlinearity is presented. The proposed DPF model is intended for the analysis of post‐contingency power flow after primary frequency regulation. During the regulation process, the governors play an important role while it is difficult to involve the nonlinear segments in the static method. So in this paper, the governor model with amplitude‐limit and deadband is simplified and included in DPF model. Using the describing function method, the effect of deadband is equivalent to an increment of regulation coefficient. The amplitude‐limit is handled by iterative correction. Applying the algorithm to a three‐node system, a case study of load variation proves the effectiveness of the algorithm. Simulations on a practical grid in southern China further demonstrates the practicability and applicability. The algorithm enhances the accuracy of post‐contingency power flow analysis and provides effective analysis for the static security of power system.
- Open Access
Optimization Strategy of SVC for Eliminating Electromagnetic Oscillation in Weak Networking Power Systems
The central Tibet AC interconnection project (CTAIP), which connects the Tibet power grid and the Sichuan power grid through a long distance transmission line of more than 1400 km, has a significant problem of voltage regulation. In order to improve the voltage regulation performance, six sets of ±60 Mvar static VAR compensators (SVC) were installed in the CTAIP. However, the SVCs may lead to electromagnetic oscillation below 50 Hz while improving voltage regulation capability. In this paper, the electromagnetic oscillation modes and the sensitivity of control parameters of SVC are analyzed. Then, the characteristics and influencing factors of the oscillation are discussed. It was found that there is an inherent electromagnetic oscillation mode below 50 Hz in the ultra-long distance transmission system. The employ of SVCs weaken the damping of this mode. Large proportional gain and integral gain (PI) parameters of SVCs can improve the voltage regulation performance, but weaken the electromagnetic oscillation mode damping. Therefore, a suppression method based on SVC PI parameters optimization is proposed to damp the oscillation. The essential of this method is to use the rising time of voltage response and setting time of SVCs as performance indicators of voltage regulation, and take the damping level of the electromagnetic oscillation mode as the performance index of SVC electromagnetic oscillation suppression ability. Combining the two indicators to form a comprehensive optimization index function, an intelligent optimization algorithm is applied. The process of SVC parameter optimization and the steps of multi-SVC parameter optimization in large power grids is proposed. Finally, PSCAD and real-time digital simulation (RTDS) simulation results verified the correctness of the proposed method. The optimization strategy was applied to CTAIP. The artificial grounding short circuit experimental results proved the effectiveness of the proposed strategy.
Open AccessOptimization Strategy of SVC for Eliminating Electromagnetic Oscillation in Weak Networking Power Systems
The central Tibet AC interconnection project (CTAIP), which connects the Tibet power grid and the Sichuan power grid through a long distance transmission line of more than 1400 km, has a significant problem of voltage regulation. In order to improve the voltage regulation performance, six sets of ±60 Mvar static VAR compensators (SVC) were installed in the CTAIP. However, the SVCs may lead to electromagnetic oscillation below 50 Hz while improving voltage regulation capability. In this paper, the electromagnetic oscillation modes and the sensitivity of control parameters of SVC are analyzed. Then, the characteristics and influencing factors of the oscillation are discussed. It was found that there is an inherent electromagnetic oscillation mode below 50 Hz in the ultra-long distance transmission system. The employ of SVCs weaken the damping of this mode. Large proportional gain and integral gain (PI) parameters of SVCs can improve the voltage regulation performance, but weaken the electromagnetic oscillation mode damping. Therefore, a suppression method based on SVC PI parameters optimization is proposed to damp the oscillation. The essential of this method is to use the rising time of voltage response and setting time of SVCs as performance indicators of voltage regulation, and take the damping level of the electromagnetic oscillation mode as the performance index of SVC electromagnetic oscillation suppression ability. Combining the two indicators to form a comprehensive optimization index function, an intelligent optimization algorithm is applied. The process of SVC parameter optimization and the steps of multi-SVC parameter optimization in large power grids is proposed. Finally, PSCAD and real-time digital simulation (RTDS) simulation results verified the correctness of the proposed method. The optimization strategy was applied to CTAIP. The artificial grounding short circuit experimental results proved the effectiveness of the proposed strategy.
- Open Access
A Two-Stage Feature Selection Method for Power System Transient Stability Status Prediction
Transient stability status prediction (TSSP) plays an important role in situational awareness of power system stability. One of the main challenges of TSSP is the high-dimensional input feature analysis. In this paper, a novel two-stage feature selection method is proposed to handle this problem. In the first stage, the relevance between features and classes is measured by normalized mutual information (NMI), and the features are ranked based on the NMI values. Then, a predefined number of top-ranked features are selected to form the strongly relevant feature subset, and the remaining features are described as the weakly relevant feature subset, which can be utilized as the prior knowledge for the next stage. In the second stage, the binary particle swarm optimization is adopted as the search algorithm for feature selection, and a new particle encoding method that considers both population diversity and prior knowledge is presented. In addition, taking the imbalanced characteristics of TSSP into consideration, an improved fitness function for TSSP feature selection is proposed. The effectiveness of the proposed method is corroborated on the Northeast Power Coordinating Council (NPCC) 140-bus system.
Open AccessA Two-Stage Feature Selection Method for Power System Transient Stability Status Prediction
Transient stability status prediction (TSSP) plays an important role in situational awareness of power system stability. One of the main challenges of TSSP is the high-dimensional input feature analysis. In this paper, a novel two-stage feature selection method is proposed to handle this problem. In the first stage, the relevance between features and classes is measured by normalized mutual information (NMI), and the features are ranked based on the NMI values. Then, a predefined number of top-ranked features are selected to form the strongly relevant feature subset, and the remaining features are described as the weakly relevant feature subset, which can be utilized as the prior knowledge for the next stage. In the second stage, the binary particle swarm optimization is adopted as the search algorithm for feature selection, and a new particle encoding method that considers both population diversity and prior knowledge is presented. In addition, taking the imbalanced characteristics of TSSP into consideration, an improved fitness function for TSSP feature selection is proposed. The effectiveness of the proposed method is corroborated on the Northeast Power Coordinating Council (NPCC) 140-bus system.
- 3 May 2018
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 846, 82-120
Experimental study and modelling of unsteady aerodynamic forces and moment on flat plate in high amplitude pitch ramp motion
This paper examines the unsteady lift, drag and moment coefficients experienced by a thin airfoil in high-amplitude pitch ramp motion. Experiments have been carried out in a wind tunnel at moderate Reynolds number ( $Re\approx 1.45\times 10^{4}$ ), using a rigid flat-plate model. Forces and moments have been measured for reduced pitch rates ranging from 0.01 to 0.18, four maximum pitch angles ( $30^{\circ },45^{\circ },60^{\circ },90^{\circ }$ ) and different pivot axis locations between the leading and the trailing edge. Results confirm that for reduced pitch rates lower than 0.03, the unsteady aerodynamics is limited to a stall delay effect. For higher pitch rates, the unsteady response is dominated by a buildup of the circulation, which increases with the pitch rate and the absolute distance between the pivot axis and the $3/4$ -chord location. This circulatory effect induces an overshoot in the normal force and moment coefficients, which is slightly reduced for a flat plate with a finite aspect ratio close to 8 in comparison with the two-dimensional configuration. A new time-dependent model has been tested for both the normal force and moment coefficients. It is mainly based on the superposition of step responses, using the Wagner function and a time-varying input that accounts for the nonlinear variation of the steady aerodynamics, the pivot point location and an additional circulation which depends on the pitch rate. When compared with experiments, it gives satisfactory results for $0^{\circ }$ to $90^{\circ }$ pitch ramp motion and captures the main effect of reduced pitch rate and pivot point location.- 3 May 2018
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 846, 82-120
Experimental study and modelling of unsteady aerodynamic forces and moment on flat plate in high amplitude pitch ramp motion
This paper examines the unsteady lift, drag and moment coefficients experienced by a thin airfoil in high-amplitude pitch ramp motion. Experiments have been carried out in a wind tunnel at moderate Reynolds number ( $Re\approx 1.45\times 10^{4}$ ), using a rigid flat-plate model. Forces and moments have been measured for reduced pitch rates ranging from 0.01 to 0.18, four maximum pitch angles ( $30^{\circ },45^{\circ },60^{\circ },90^{\circ }$ ) and different pivot axis locations between the leading and the trailing edge. Results confirm that for reduced pitch rates lower than 0.03, the unsteady aerodynamics is limited to a stall delay effect. For higher pitch rates, the unsteady response is dominated by a buildup of the circulation, which increases with the pitch rate and the absolute distance between the pivot axis and the $3/4$ -chord location. This circulatory effect induces an overshoot in the normal force and moment coefficients, which is slightly reduced for a flat plate with a finite aspect ratio close to 8 in comparison with the two-dimensional configuration. A new time-dependent model has been tested for both the normal force and moment coefficients. It is mainly based on the superposition of step responses, using the Wagner function and a time-varying input that accounts for the nonlinear variation of the steady aerodynamics, the pivot point location and an additional circulation which depends on the pitch rate. When compared with experiments, it gives satisfactory results for $0^{\circ }$ to $90^{\circ }$ pitch ramp motion and captures the main effect of reduced pitch rate and pivot point location.