Palangadan Rajesh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Palangadan Rajesh has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Chirathodi Vayalappil Muraleedharan
Sree Chitra Tirunal Institute for Medical Sciences and Technology
4 shared publications - Harikrishna Varma
Sree Chitra Tirunal Institute for Medical Sciences and Technology (SCTIMST)
4 shared publications - Manoj Komath
Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology (SCTIMST), Trivandrum, Kerala, India
4 shared publications Harikrishna Varma
Bioceramics Laboratory, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala 695012, India
3 shared publicationsNimmy Mohan
Bioceramics Laboratory, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala 695012, India
2 shared publications- Sukumaran Anil
Dental Research Cell, Dr. D. Y. Patil Dental College & Hospital, Dr. D. Y. Patil Vidyapeeth (deemed to be University), Pimpri, Pune, India
2 shared publications
Latest Publications
- 1 November 2016
- Published by Elsevier in Ceramics International
- Vol. 42 (15) , 17259-17268
Hydroxyapatite scaffolds constituting highly oriented crystals derived from synthetic precursors by hydrothermal reactions
- 1 November 2016
- Published by Elsevier in Ceramics International
- Vol. 42 (15) , 17259-17268
Hydroxyapatite scaffolds constituting highly oriented crystals derived from synthetic precursors by hydrothermal reactions
- 24 June 2015
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 18 (4) , 666-677
Combined Treatment Effects Using Bioactive‐Coated Implants and Ceramic Granulate in a Rabbit Femoral Condyle Model
Within the limitations of this study, it can be concluded that silicon substitution in HA favors bone regeneration compared with HA, especially when used as bone substitute material. Further studies using different healing periods will elucidate the resorption pattern of HASi granules in comparison with HA.
- 24 June 2015
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 18 (4) , 666-677
Combined Treatment Effects Using Bioactive‐Coated Implants and Ceramic Granulate in a Rabbit Femoral Condyle Model
Within the limitations of this study, it can be concluded that silicon substitution in HA favors bone regeneration compared with HA, especially when used as bone substitute material. Further studies using different healing periods will elucidate the resorption pattern of HASi granules in comparison with HA.
- 1 July 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (5) , 2899-2904
Pulsed laser deposition of hydroxyapatite on nanostructured titanium towards drug eluting implants
- 1 July 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (5) , 2899-2904
Pulsed laser deposition of hydroxyapatite on nanostructured titanium towards drug eluting implants
- 18 April 2013
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 28 (6) , 849-858
Pulsed laser deposition and in vitro characteristics of triphasic – HASi composition on titanium
Pulsed laser deposition was used to deposit bioactive triphasic glass-ceramic composition (HASi) over titanium substrate using dense HASi target. Bioactive glass compositions are considered the most useful synthetic materials for immediate bone attachment because of its bioresorption, osteoconduction and osteointegration characteristics under in vivo conditions. The disadvantage of its brittleness associated with bioactive glass-ceramics has prompted its coating over metallic implants for the combination of duo mechanical and bioactive properties. The hard HASi target was able to undergo laser ablation under ambient gas pressure without bulk erosion of the target. Laser deposition was found to be efficient in depositing triphasic composition for immediate bone integration. The target and deposits were analyzed for the phase, composition and microstructural characteristics by means of X-ray diffraction, Fourier transform infrared spectroscopy, energy-dispersive X-ray analysis and scanning electron microscopy. Simultaneously, the adherent nature and mechanical behaviour of deposits were confirmed by scratch test and micro-indentation methods. Further, the in vitro dissolution and bioactivity were assessed by soaking in simulated body fluid followed by elemental analysis using inductively coupled plasma spectroscopy. The deposits were found to be cell-friendly, which was indicated by the phenomenology of stem cells under in vitro conditions.
- 18 April 2013
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 28 (6) , 849-858
Pulsed laser deposition and in vitro characteristics of triphasic – HASi composition on titanium
Pulsed laser deposition was used to deposit bioactive triphasic glass-ceramic composition (HASi) over titanium substrate using dense HASi target. Bioactive glass compositions are considered the most useful synthetic materials for immediate bone attachment because of its bioresorption, osteoconduction and osteointegration characteristics under in vivo conditions. The disadvantage of its brittleness associated with bioactive glass-ceramics has prompted its coating over metallic implants for the combination of duo mechanical and bioactive properties. The hard HASi target was able to undergo laser ablation under ambient gas pressure without bulk erosion of the target. Laser deposition was found to be efficient in depositing triphasic composition for immediate bone integration. The target and deposits were analyzed for the phase, composition and microstructural characteristics by means of X-ray diffraction, Fourier transform infrared spectroscopy, energy-dispersive X-ray analysis and scanning electron microscopy. Simultaneously, the adherent nature and mechanical behaviour of deposits were confirmed by scratch test and micro-indentation methods. Further, the in vitro dissolution and bioactivity were assessed by soaking in simulated body fluid followed by elemental analysis using inductively coupled plasma spectroscopy. The deposits were found to be cell-friendly, which was indicated by the phenomenology of stem cells under in vitro conditions.
- 1 May 2012
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 134 (1) , 464-477
Enhancement of wettability and antibiotic loading/release of hydroxyapatite thin film modified by 100MeV Ag7+ ion irradiation
- 1 May 2012
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 134 (1) , 464-477
Enhancement of wettability and antibiotic loading/release of hydroxyapatite thin film modified by 100MeV Ag7+ ion irradiation
- 22 November 2011
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 23 (2) , 339-348
Preparation and analysis of chemically gradient functional bioceramic coating formed by pulsed laser deposition
Bioactive ceramic coatings based on calcium phosphates yield better functionality in the human body for a variety of metallic implant devices including orthopaedic and dental prostheses. In the present study chemically and hence functionally gradient bioceramic coating was obtained by pulsed laser deposition method. Calcium phosphate bioactive ceramic coatings based on hydroxyapatite (HA) and tricalcium phosphate (TCP) were deposited over titanium substrate to produce gradation in physico-chemical characteristics and in vitro dissolution behaviour. Sintered targets of HA and α-TCP were deposited in a multi target laser deposition system. The obtained deposits were characterized by X-ray diffraction, fourier transform infrared spectroscopy, scanning electron microscopy and energy dispersive X-ray analysis. Inductively coupled plasma spectroscopy was used to estimate the in vitro dissolution behaviour of coatings. The variation in mechanical property of the gradient layer was evaluated through scratch test and micro-indentation hardness. The bioactivity was examined in vitro with respect to the ability of HA layer to form on the surface as a result of contact with simulated body fluid. It could be inferred that chemically gradient functional bioceramic coating can be produced by laser deposition of multiple sintered targets with variable chemical composition.
- 22 November 2011
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 23 (2) , 339-348
Preparation and analysis of chemically gradient functional bioceramic coating formed by pulsed laser deposition
Bioactive ceramic coatings based on calcium phosphates yield better functionality in the human body for a variety of metallic implant devices including orthopaedic and dental prostheses. In the present study chemically and hence functionally gradient bioceramic coating was obtained by pulsed laser deposition method. Calcium phosphate bioactive ceramic coatings based on hydroxyapatite (HA) and tricalcium phosphate (TCP) were deposited over titanium substrate to produce gradation in physico-chemical characteristics and in vitro dissolution behaviour. Sintered targets of HA and α-TCP were deposited in a multi target laser deposition system. The obtained deposits were characterized by X-ray diffraction, fourier transform infrared spectroscopy, scanning electron microscopy and energy dispersive X-ray analysis. Inductively coupled plasma spectroscopy was used to estimate the in vitro dissolution behaviour of coatings. The variation in mechanical property of the gradient layer was evaluated through scratch test and micro-indentation hardness. The bioactivity was examined in vitro with respect to the ability of HA layer to form on the surface as a result of contact with simulated body fluid. It could be inferred that chemically gradient functional bioceramic coating can be produced by laser deposition of multiple sintered targets with variable chemical composition.
- 20 May 2011
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 22 (7) , 1671-1679
Laser surface modification of titanium substrate for pulsed laser deposition of highly adherent hydroxyapatite
Biomedical implant devices made out of titanium and its alloys are benefited by a modified surface or a bioactive coating to enhance bone bonding ability and to function effectively in vivo for the intended period of time. In this respect hydroxyapatite coating developed through pulsed laser deposition is a promising approach. Since the success of the bioactive ceramic coated implant depends mainly on the substrate-coating strength; an attempt has been made to produce micro patterned surface structure on titanium substrate for adherent hydroxyapatite coating. A pulsed Nd-YAG laser beam (355 nm) with 10 Hz repetition rate was used for surface treatment of titanium as well as hydroxyapatite deposition. The unfocussed laser beam was used to modify the substrate surface with 500–18,000 laser pulses while keeping the polished substrate in water. Hydroxyapatite deposition was done in a vacuum deposition chamber at 400°C with the focused laser beam under 1 × 10−3 mbar oxygen pressure. Deposits were analyzed to understand the physico-chemical, morphological and mechanical characteristics. The obtained substrate and coating surface morphology indicates that laser treatment method can provide controlled micro-topography. Scratch test analysis and microindentation hardness values of coating on laser treated substrate indicate higher mechanical adhesion with respect to coatings on untreated substrates.
- 20 May 2011
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 22 (7) , 1671-1679
Laser surface modification of titanium substrate for pulsed laser deposition of highly adherent hydroxyapatite
Biomedical implant devices made out of titanium and its alloys are benefited by a modified surface or a bioactive coating to enhance bone bonding ability and to function effectively in vivo for the intended period of time. In this respect hydroxyapatite coating developed through pulsed laser deposition is a promising approach. Since the success of the bioactive ceramic coated implant depends mainly on the substrate-coating strength; an attempt has been made to produce micro patterned surface structure on titanium substrate for adherent hydroxyapatite coating. A pulsed Nd-YAG laser beam (355 nm) with 10 Hz repetition rate was used for surface treatment of titanium as well as hydroxyapatite deposition. The unfocussed laser beam was used to modify the substrate surface with 500–18,000 laser pulses while keeping the polished substrate in water. Hydroxyapatite deposition was done in a vacuum deposition chamber at 400°C with the focused laser beam under 1 × 10−3 mbar oxygen pressure. Deposits were analyzed to understand the physico-chemical, morphological and mechanical characteristics. The obtained substrate and coating surface morphology indicates that laser treatment method can provide controlled micro-topography. Scratch test analysis and microindentation hardness values of coating on laser treated substrate indicate higher mechanical adhesion with respect to coatings on untreated substrates.
- 1 April 2011
- Published by Springer Nature in Bulletin of Materials Science
- Vol. 34 (2) , 389-399
Formation of hydroxyapatite coating on titanium at 200°C through pulsed laser deposition followed by hydrothermal treatment
- 1 April 2011
- Published by Springer Nature in Bulletin of Materials Science
- Vol. 34 (2) , 389-399
Formation of hydroxyapatite coating on titanium at 200°C through pulsed laser deposition followed by hydrothermal treatment
- 14 January 2011
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 22 (3) , 497-505
Pulsed laser deposition of hydroxyapatite on titanium substrate with titania interlayer
Pulsed laser deposition (PLD) has been used to deposit hydroxyapatite (HA) ceramic over titanium substrate with an interlayer of titania. PLD has been identified as a potential candidate for bioceramic coatings over metallic substrates to be used as orthopedic and dental implants because of better process control and preservation of phase identity of the coating component. However, direct deposition of hydroxyapatite on titanium at elevated temperature results in the formation of natural oxide layer along with some perovskites like calcium titanate at the interface. This leads to easy debonding of ceramic layer from the metal and thereby affecting the adhesion strength. In the present study, adherent and stable HA coating over Ti6Al4V was achieved with the help of an interlayer of titania. The interlayer was made to a submicron level and HA was deposited consecutively to a thickness of around one micron by exposing to laser ablation at a substrate temperature of 400°C. The deposited phase was identified to be phase pure HA by X-ray diffraction, scanning electron microscopy, energy dispersive X-ray analysis, and inductively coupled plasma spectrometry. The mechanical behavior of coating evaluated by scratch test indicates that the adhesion strength of HA coating was improved with the presence of titania interlayer.
- 14 January 2011
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 22 (3) , 497-505
Pulsed laser deposition of hydroxyapatite on titanium substrate with titania interlayer
Pulsed laser deposition (PLD) has been used to deposit hydroxyapatite (HA) ceramic over titanium substrate with an interlayer of titania. PLD has been identified as a potential candidate for bioceramic coatings over metallic substrates to be used as orthopedic and dental implants because of better process control and preservation of phase identity of the coating component. However, direct deposition of hydroxyapatite on titanium at elevated temperature results in the formation of natural oxide layer along with some perovskites like calcium titanate at the interface. This leads to easy debonding of ceramic layer from the metal and thereby affecting the adhesion strength. In the present study, adherent and stable HA coating over Ti6Al4V was achieved with the help of an interlayer of titania. The interlayer was made to a submicron level and HA was deposited consecutively to a thickness of around one micron by exposing to laser ablation at a substrate temperature of 400°C. The deposited phase was identified to be phase pure HA by X-ray diffraction, scanning electron microscopy, energy dispersive X-ray analysis, and inductively coupled plasma spectrometry. The mechanical behavior of coating evaluated by scratch test indicates that the adhesion strength of HA coating was improved with the presence of titania interlayer.