CMChirathodi Vayalappil Muraleedharan

Chirathodi Vayalappil Muraleedharan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chirathodi Vayalappil Muraleedharan has a total of 99 co-authors. Here are the top co-authors by number of shared publications:

  • Roy Joseph

    Medical Devices Engineering, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Biomedical Technology Wing, Poojapura, Thiruvananthapuram, Kerala, 695012, INDIA

    5 shared publications
  • G. S. Bhuvaneshwar

    Division of Artificial Organs, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences & Technology, Thiruvananthapuram, India

    4 shared publications
  • Manoj Komath

    Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology (SCTIMST), Trivandrum, Kerala, India

    4 shared publications
  • Palangadan Rajesh

    Bioceramic Laboratory, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, Kerala, India

    4 shared publications
  • Adathala Rajeev

    Department of Medical Devices Engineering, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum, India

    3 shared publications
  • Harikrishna Varma

    Sree Chitra Tirunal Institute for Medical Sciences and Technology (SCTIMST)

    3 shared publications

Latest Publications

  • Impact of design optimization on cyclic loading performance of novel pedicle screw and comparison with control device: a bilayer model simulation study

    by Arvind Kumar Prajapati, Harikrishna Varma Parimanathukovilakom Ramavarma, Gurunathan Saravana Kumar, Chirathody Vayalappil Muraleedharan, Roy Joseph, Payanam Ramachandra Umashankar

    This study investigates the fatigue behaviour of a novel pedicle screw design, comparing its performance with a control device using the finite element method. Pedicle screw-based treatments are standard methods in spinal fusion procedures. However, complications such as screw loosening and breakage occur in both osteoporotic and non-osteoporotic patients, often due to high bone-implant interface stress and fatigue failure. A novel pedicle screw was designed, and its performance was compared with a control device. A cylindrical bone model of human vertebrae was developed with lamina and cortico-cancellous properties, and the screws were assigned properties of medical grade titanium alloy. The outer surfaces of the screw head model were constrained, and a time varying moment simulating clinical conditions was applied at a distance from the screw head. Stress and strain on the bone model, safety factor, life, and fatigue sensitivity on the screws were determined. Results indicate that the von Mises stress on the bone models was reduced for the novel design, and it performed better in terms of life than the control device. The novel design also provided a greater safety factor than the control device, which is likely to improve pedicle screw life. These findings suggest that the novel screw design enhances performance, potentially leading to better patient outcomes. The study offers valuable insights for researchers developing spinal pedicle screws and evaluating their cyclic performance using finite element analysis.


  • Open Access

    A novel pedicle screw design to maximize screw-bone interface strength using finite element analysis and design of experiment techniques

    by Arvind Kumar Prajapati, Parimanathukovilakom Ramavarma Harikrishna Varma, Gurunathan Saravana Kumar, Chirathody Vayalappil Muraleedharan, Ganesh Divakar

    Study Design: Basic study.Purpose: This study aimed to utilize finite element (FE) analysis and design of experiment (DoE) techniques to propose and optimize a novel pedicle screw design and compare its pull-out force with that of a control device.Overview of Literature: Pedicle screw-based fixation is the gold-standard treatment for spine diseases, particularly in fusion procedures. However, pedicle screw loosening and breakage still occur in osteoporotic and non-osteoporotic patients. This research investigates screw design modifications to enhance screw-bone interface strength and reduce the likelihood of loosening.Methods: We conceptualized a novel pedicle screw considering vertebral bone morphology and strength differences. A validated FE model was developed and used in conjunction with DoE to determine the screwŐšs optimum geometrical parameters. The FE model was validated through simulation and laboratory experiments using the control device. The optimized thread profiles for cortical bone and cancellous bone were determined, with pull-out force as the primary factor for screw design evaluation.Results: FE analysis results for the control device closely matched experimental results, with less than 5% difference. The chosen unique pitch/depth ratio showed maximum pull-out force for cortical bone, while DoE enabled the optimization of design parameters for cancellous bone. The optimized pedicle screw exhibited a 15% increase in pull-out force compared to the control device.Conclusions: The study proposes a novel pedicle screw design with better pull-out strength than the control device. Combining FE analysis with DoE is an effective approach for screw design optimization, reducing the need for extensive prototyping tests. A two-variable analysis suffices for optimizing cortical bone design parameters, while a multi-variable analysis is more effective for optimizing cancellous bone design parameters.


  • Top Cited Papers

    Digital health: trends, opportunities and challenges in medical devices, pharma and bio-technology

    by Naresh Kasoju, N. S. Remya, Renjith Sasi, S. Sujesh, Biju Soman, C. Kesavadas, C. V. Muraleedharan, P. R. Harikrishna Varma, Sanjay Behari

    Digital health interventions refer to the use of digital technology and connected devices to improve health outcomes and healthcare delivery. This includes telemedicine, electronic health records, wearable devices, mobile health applications, and other forms of digital health technology. To this end, several research and developmental activities in various fields are gaining momentum. For instance, in the medical devices sector, several smart biomedical materials and medical devices that are digitally enabled are rapidly being developed and introduced into clinical settings. In the pharma and allied sectors, digital health-focused technologies are widely being used through various stages of drug development, viz. computer-aided drug design, computational modeling for predictive toxicology, and big data analytics for clinical trial management. In the biotechnology and bioengineering fields, investigations are rapidly growing focus on digital health, such as omics biology, synthetic biology, systems biology, big data and personalized medicine. Though digital health-focused innovations are expanding the horizons of health in diverse ways, here the development in the fields of medical devices, pharmaceutical technologies and biotech sectors, with emphasis on trends, opportunities and challenges are reviewed. A perspective on the use of digital health in the Indian context is also included.


  • Open Access

    Preclinical evaluation of hydrogel sealed fluropassivated indigenous vascular prosthesis

    by Madathipat Unnikrishnan, P.R. Umashankar, Sidharth Viswanathan, Ajay Savlania, Roy Joseph, C.V. Muraleedharan, Vivek Agrawal, Sachin J. Shenoy, Lissy K. Krishnan, P.V. Mohanan, et al.

    Background & objectives: Polyethylene terephthalate (PET) graft, designed and developed at our institute for vascular reconstruction, is porous to promote optimal incorporation and neointima formation, requiring pre-clotting or biomodification by sealing the pores before implantation. The objective of this study was to characterize, test and perform preclinical evaluation of hydrogel (alginate dialdehyde cross-linked gelatin) sealed fluoropassivated PET vascular prosthesis in pig model, so as to avoid pre-clotting, for its safety and efficacy before employing the indigenous and less expensive graft for clinical use. Methods: Hydrogel sealed, fluoropassivated PET vascular prosthesis were tested for haemocompatibility and toxicity followed by small animal toxicology tests and in vivo experiments in pigs receiving implantation at thoracic aorta. All 33 animals received test as well as control grafts with a plan for phased explantation at 2, 12 and 26 weeks. All animals underwent completion angiogram at the end of procedure as well as before graft explantation. Results: Haemocompatibility tests for haemolysis and toxicity tests showed no adverse events in tested mice and rabbits. Completion angiogram showed intact anastamosis and patent graft in each animal in post-operative period and at explantation. Gross and histopathological examination showed well-encapsulated grafts, clean glistening neointima and no evidence of thrombus in both test and control grafts. Interpretation & conclusions: Hydrogel sealed, fluoropassivated PET vascular prosthesis was found non-toxic, haemocompatible and remained patent in in vivo studies at planned intervals.

  • TTK Chitra tilting disc heart valve model TC2: An assessment of fatigue life and durability

    by Nn Subhash, Adathala Rajeev, Sreedharan Sujesh, Cv Muraleedharan

    Average age group of heart valve replacement in India and most of the Third World countries is below 30 years. Hence, the valve for such patients need to be designed to have a service life of 50 years or more which corresponds to 2000 million cycles of operation. The purpose of this study was to assess the structural performance of the TTK Chitra tilting disc heart valve model TC2 and thereby address its durability. The TC2 model tilting disc heart valves were assessed to evaluate the risks connected with potential structural failure modes. To be more specific, the studies covered the finite element analysis–based fatigue life prediction and accelerated durability testing of the tilting disc heart valves for nine different valve sizes. First, finite element analysis–based fatigue life prediction showed that all nine valve sizes were in the infinite life region. Second, accelerated durability test showed that all nine valve sizes remained functional for 400 million cycles under experimental conditions. The study ensures the continued function of TC2 model tilting disc heart valves over duration in excess of 50 years. The results imply that the TC2 model valve designs are structurally safe, reliable and durable.


  • Experimental and Numerical Study of Stenotic Flows

    by S. M. Abdul Khader, Rajeev, Anurag Ayachit, Raghuvir Pai, C. V. Muraleedharan, M. Zubair, V. R. K. Rao


  • Open Access

    The making of indigenous vascular prosthesis

    by Madathipat Unnikrishnan, Sidharth Viswanathan, K. Balasubramaniam, C.V. Muraleedharan, Arthur Vijayan Lal, P.V. Mohanan, Meera Mohanty, Tirur Raman Kapilamoorthy

    Background & objectives: Vascular illnesses are on the rise in India, due to increase in lifestyle diseases and demographic transition, requiring intervention to save life, organ or limbs using vascular prosthesis. The aim of this study was to develop indigenous large diameter vascular graft for treatment of patients with vascular pathologies. Methods: The South India Textile Research Association, at Coimbatore, Tamil Nadu, India, developed seamless woven polyester (Polyethylene terephthalate) graft at its research wing. Further characterization and testing followed by clinical trials were conducted at Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram, Kerala, India. Fifteen in vivo experiments were carried out in 1992-1994 in pigs as animal model. Controlled (phase I) clinical trial in ten patients was performed along with control graft. Thereafter, phase II trial involved 22 patients who underwent multi-centre clinical trial in four centres across India. Results: Laboratory testing showed that polyester graft was non-toxic, non-leeching and non-haemolytic with preserved long-term quality, further confirming in pigs by implanting in thoracic aorta, comparable to control Dacron grafts. Perigraft incorporation and smooth neointima formation which are prime features of excellent healing characteristics, were noted at explantation at planned intervals. Subsequently in the phase I and II clinical trials, all patients had excellent recovery without mortality or device-related adverse events. Patients receiving the test graft were followed up for 10 and 5 years, respectively. Serial clinical, duplex scans and CT angiograms performed periodically confirmed excellent graft performance. Interpretation & conclusions: Indigenously developed Chitra vascular graft was comparable to commercially available Dacron graft, ready for clinical use at affordable cost to patients as against costly imported grafts.


  • Open Access

    Cardiovascular haemodynamics: Advancement of numerical and experimental diagnostic tools

    by Yosry Morsi, Leif Hellevik, Aike Qiao, Muraleedharan C Vayalappil, Jiyuan Tu, William Yang

  • Evaluation of Polypropylene Hollow-Fiber Prototype Bioreactor for Bioartificial Liver

    by Anwar Azad Palakkan, Deepa K. Raj, Jose Rojan, Sajin Raj R.G., P.R. Anil Kumar, C.V. Muraleedharan, T.V. Kumary

    Hepatocytes in high density are a requisite for the functional performance of complex devices such as bioartificial liver (BAL). In addition to high cell number, efficient mass transfer is also a key parameter in such devices. High-density culture of cells and efficient mass transfer can be achieved in BAL with hollow-fiber-based bioreactors. Even though different types of hollow fibers have been tried in a BAL, prospects of using polypropylene hollow fibers are not well evaluated. In this study, a prototype of bioreactor with polypropylene hollow fibers was fabricated and evaluated for cytotoxicity and hepatocyte function. High density of HepG2/adult hepatocyte cultures was used to evaluate polypropylene hollow fiber to support the biochemical activities (albumin and urea production), ammonia detoxification, and gene expression and to provide effective oxygenation. The results confirmed that a polypropylene hollow-fiber prototype bioreactor is able to provide efficient oxygenation and supported hepatocyte functions in a high-density culture.