Vivian P. Kamphuis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Vivian P. Kamphuis has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Jos J. M. Westenberg
Department of Radiology Feinberg School of Medicine, Northwestern University, Chicago, USA
4 shared publications- Mohammed S. M. Elbaz
Department of Radiology Northwestern University Feinberg School of Medicine Chicago IL USA
4 shared publications Albert de Roos
From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.).
3 shared publicationsArno A. W. Roest
From the Department of Pediatrics, Division of Pediatric Cardiology (V.P.K., A.A.W.R.), Department of Radiology (P.J.v.d.B., L.J.M.K., A.d.R., H.J.L., J.J.M.W.), and Department of Cardiology (N.A.M., J.J.B.), Leiden University Medical Center, Albinusdreef 2, 2333 ZA, Leiden, the Netherlands; Netherlands Heart Institute, Utrecht, the Netherlands (V.P.K.); and Pie Medical Imaging BV, Maastricht, the Netherlands (J.P.A.).
3 shared publications- Nico Blom
Willem-Alexander Children's Hospital - Leiden University Medical Center; Department of Pediatric Cardiology; Albinusdreef 2, Leiden, the Netherlands
3 shared publications - Arend Derk Jan Ten Harkel
Department of Pediatric Cardiology, Willem Alexander Children’s Hospital, Leiden University Medical Center, Leiden, The Netherlands
2 shared publications
Latest Publications
- Open Access
- 1 June 2019
- Published by Elsevier in International Journal of Cardiology
- Vol. 285, 32-39
Electrical remodeling after percutaneous atrial septal defect closure in pediatric and adult patients
- 1 June 2019
- Published by Elsevier in International Journal of Cardiology
- Vol. 285, 32-39
Open AccessElectrical remodeling after percutaneous atrial septal defect closure in pediatric and adult patients
- Open Access
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 43-11
Stress increases intracardiac 4D flow cardiovascular magnetic resonance -derived energetics and vorticity and relates to VO2max in Fontan patients
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 43-11
Open AccessStress increases intracardiac 4D flow cardiovascular magnetic resonance -derived energetics and vorticity and relates to VO2max in Fontan patients
- 1 January 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 290 (1) , 70-78
Automated Cardiac Valve Tracking for Flow Quantification with Four-dimensional Flow MRI
Four-dimensional flow MRI with automated cardiac valve tracking reduces analysis time and improves reliability of valvular flow quantification compared with manual valve tracking in patients with acquired or congenital heart disease and in healthy volunteers. Purpose To compare four-dimensional flow MRI with automated valve tracking to manual valve tracking in patients with acquired or congenital heart disease and healthy volunteers. Materials and Methods In this retrospective study, data were collected from 114 patients and 46 volunteers who underwent four-dimensional flow MRI at 1.5 T or 3.0 T from 2006 through 2017. Among the 114 patients, 33 had acquired and 81 had congenital heart disease (median age, 17 years; interquartile range [IQR], 13–49 years), 51 (45%) were women, and 63 (55%) were men. Among the 46 volunteers (median age, 28 years; IQR, 22–36 years), there were 19 (41%) women and 27 (59%) men. Two orthogonal cine views of each valve were used for valve tracking. Wilcoxon signed-rank test was used to compare analysis times, net forward volumes (NFVs), and regurgitant fractions. Intra- and interobserver variability was tested by using intraclass correlation coefficients (ICCs). Results Analysis time was shorter for automated versus manual tracking ...
- 1 January 2019
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 290 (1) , 70-78
Automated Cardiac Valve Tracking for Flow Quantification with Four-dimensional Flow MRI
Four-dimensional flow MRI with automated cardiac valve tracking reduces analysis time and improves reliability of valvular flow quantification compared with manual valve tracking in patients with acquired or congenital heart disease and in healthy volunteers. Purpose To compare four-dimensional flow MRI with automated valve tracking to manual valve tracking in patients with acquired or congenital heart disease and healthy volunteers. Materials and Methods In this retrospective study, data were collected from 114 patients and 46 volunteers who underwent four-dimensional flow MRI at 1.5 T or 3.0 T from 2006 through 2017. Among the 114 patients, 33 had acquired and 81 had congenital heart disease (median age, 17 years; interquartile range [IQR], 13–49 years), 51 (45%) were women, and 63 (55%) were men. Among the 46 volunteers (median age, 28 years; IQR, 22–36 years), there were 19 (41%) women and 27 (59%) men. Two orthogonal cine views of each valve were used for valve tracking. Wilcoxon signed-rank test was used to compare analysis times, net forward volumes (NFVs), and regurgitant fractions. Intra- and interobserver variability was tested by using intraclass correlation coefficients (ICCs). Results Analysis time was shorter for automated versus manual tracking ...
- 1 January 2019
- Published by Elsevier in Journal of Electrocardiology
- Vol. 52, 53-58
Electrocardiographic characteristics before and after correction of right-sided congenital heart defects in children and its relation to prognosis
- 1 January 2019
- Published by Elsevier in Journal of Electrocardiology
- Vol. 52, 53-58
Electrocardiographic characteristics before and after correction of right-sided congenital heart defects in children and its relation to prognosis
- Open Access
- 29 January 2018
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 19 (5) , 587-588
Direct assessment of tricuspid regurgitation by 4D flow cardiovascular magnetic resonance in a patient with Ebstein’s anomaly
A patient with Ebstein’s anomaly, a rare congenital heart disease in which the septal and posterior leaflets of the tricuspid valve are located more apically (Panel A, stylized representation of the tricuspid valve leaflets with the septal leaflet indicated by an arrow, RV: right ventricle, LV: left ventricle), in sinus rhythm, underwent cardiovascular magnetic resonance (CMR) imaging including state-of-the-art whole-heart 4D flow CMR.
- 29 January 2018
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 19 (5) , 587-588
Open AccessDirect assessment of tricuspid regurgitation by 4D flow cardiovascular magnetic resonance in a patient with Ebstein’s anomaly
A patient with Ebstein’s anomaly, a rare congenital heart disease in which the septal and posterior leaflets of the tricuspid valve are located more apically (Panel A, stylized representation of the tricuspid valve leaflets with the septal leaflet indicated by an arrow, RV: right ventricle, LV: left ventricle), in sinus rhythm, underwent cardiovascular magnetic resonance (CMR) imaging including state-of-the-art whole-heart 4D flow CMR.
- Open Access
- 6 January 2018
- Published by Elsevier in Journal of Electrocardiology
- Vol. 51 (3) , 490-495
Normal values of the ventricular gradient and QRS-T angle, derived from the pediatric electrocardiogram
- 6 January 2018
- Published by Elsevier in Journal of Electrocardiology
- Vol. 51 (3) , 490-495
Open AccessNormal values of the ventricular gradient and QRS-T angle, derived from the pediatric electrocardiogram
- Open Access
- 5 January 2018
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 34 (6) , 905-920
Scan–rescan reproducibility of diastolic left ventricular kinetic energy, viscous energy loss and vorticity assessment using 4D flow MRI: analysis in healthy subjects
The aim of the current study was to assess the scan–rescan reproducibility of left ventricular (LV) kinetic energy (KE), viscous energy loss (EL) and vorticity during diastole from four-dimensional flow magnetic resonance imaging (4D flow MRI) in healthy subjects. Twelve volunteers (age 27 ± 3 years) underwent whole-heart 4D flow MRI twice in one session. In-scan consistency was evaluated by correlation between KE and EL. ELindex was computed to measure the amount of EL relative to KE over diastole. Scan–rescan analysis was performed to test reproducibility of volumetric measurements of KE, EL, ELindex and vorticity in the LV over early (E) and late (A) diastolic filling. In-scan consistency between KE and EL was strong-excellent (E-filling scan1: r = 0.92, P < 0.001; scan2: ρ = 0.96, P < 0.001 and A-filling scan1: ρ = 0.87, P < 0.001; scan2: r = 0.99, P < 0.001). For the majority of subjects (10 out of 12), KE and EL measures showed good to strong reproducibility. However, with a wide range of agreement [intraclass correlation (ICC): 0.64–0.95] and coefficients of variation (CV) ≤ 25%. ELindex showed strong reproducibility for all 12 subjects with a strong ICC (0.94, P < 0.001) and a CV of 9%. Scan–rescan reproducibility of volumetric vorticity showed good–excellent ICCs (0.83–0.95) with CVs ≤ 11%. In conclusion, the current study shows strong–excellent in-scan consistency and overall good agreement between scans for 4D flow MRI assessment of left ventricular kinetic energy, energy loss and vorticity over diastole. However, substantial differences between the scans were also found in some parameters in two out of twelve subjects. Strong reproducibility was found in the dimensionless ELindex, which measures the amount of viscous energy loss relative to the average kinetic energy over diastole.
- 5 January 2018
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 34 (6) , 905-920
Open AccessScan–rescan reproducibility of diastolic left ventricular kinetic energy, viscous energy loss and vorticity assessment using 4D flow MRI: analysis in healthy subjects
The aim of the current study was to assess the scan–rescan reproducibility of left ventricular (LV) kinetic energy (KE), viscous energy loss (EL) and vorticity during diastole from four-dimensional flow magnetic resonance imaging (4D flow MRI) in healthy subjects. Twelve volunteers (age 27 ± 3 years) underwent whole-heart 4D flow MRI twice in one session. In-scan consistency was evaluated by correlation between KE and EL. ELindex was computed to measure the amount of EL relative to KE over diastole. Scan–rescan analysis was performed to test reproducibility of volumetric measurements of KE, EL, ELindex and vorticity in the LV over early (E) and late (A) diastolic filling. In-scan consistency between KE and EL was strong-excellent (E-filling scan1: r = 0.92, P < 0.001; scan2: ρ = 0.96, P < 0.001 and A-filling scan1: ρ = 0.87, P < 0.001; scan2: r = 0.99, P < 0.001). For the majority of subjects (10 out of 12), KE and EL measures showed good to strong reproducibility. However, with a wide range of agreement [intraclass correlation (ICC): 0.64–0.95] and coefficients of variation (CV) ≤ 25%. ELindex showed strong reproducibility for all 12 subjects with a strong ICC (0.94, P < 0.001) and a CV of 9%. Scan–rescan reproducibility of volumetric vorticity showed good–excellent ICCs (0.83–0.95) with CVs ≤ 11%. In conclusion, the current study shows strong–excellent in-scan consistency and overall good agreement between scans for 4D flow MRI assessment of left ventricular kinetic energy, energy loss and vorticity over diastole. However, substantial differences between the scans were also found in some parameters in two out of twelve subjects. Strong reproducibility was found in the dimensionless ELindex, which measures the amount of viscous energy loss relative to the average kinetic energy over diastole.
- Open Access
- 30 September 2017
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 34 (3) , 441-442
Biventricular vortex ring formation corresponds to regions of highest intraventricular viscous energy loss in a Fontan patient: analysis by 4D Flow MRI
- 30 September 2017
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 34 (3) , 441-442
Open AccessBiventricular vortex ring formation corresponds to regions of highest intraventricular viscous energy loss in a Fontan patient: analysis by 4D Flow MRI
- Open Access
- 22 June 2017
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 47 (2) , 511-522
In‐scan and scan–rescan assessment of LV in‐ and outflow volumes by 4D flow MRI versus 2D planimetry
Purpose: To evaluate the in‐scan and scan–rescan consistency of left ventricular (LV) in‐ and outflow assessment from 1) 2D planimetry; 2) 4D flow magnetic resonance imaging (MRI) with retrospective valve tracking, and 3) 4D flow MRI with particle tracing.Materials and Methods: Ten healthy volunteers (age 27 ± 3 years) underwent multislice cine short‐axis planimetry and whole‐heart 4D flow MRI on a 3T MRI scanner twice with repositioning between the scans. LV in‐ and outflow was compared from 1) 2D planimetry; 2) 4D flow MRI with retrospective valve tracking over the mitral valve (MV) and aortic valve (AV), and 3) 4D flow MRI with particle tracing through forward and backward integration of velocity data.Results: In‐scan consistency between MV and AV flow volumes is excellent for both 4D flow MRI methods with r ≥ 0.95 (P ≤ 0.001). In‐scan AV and MV flow by retrospective valve tracking shows good to excellent correlations versus AV and MV flow by particle tracing (r ≥ 0.81, P ≤ 0.004). Scan–rescan SV assessment by 2D planimetry shows excellent reproducibility (intraclass correlation [ICC] = 0.98, P < 0.001, coefficient of variation [CV] = 7%). Scan–rescan MV and AV flow volume assessment by retrospective valve tracking shows strong reproducibility (ICCs ≥ 0.89, P ≤ 0.05, CVs = 12%), as well as by forward and backward particle tracing (ICCs ≥ 0.90, P ≤ 0.001, CVs ≤ 11%). Multicomponent particle tracing shows good scan–rescan reproducibility (ICCs ≥ 0.81, P ≤ 0.007, CVs ≤ 16%).Conclusion: LV in‐ and outflow assessment by 2D planimetry and 4D flow MRI with retrospective valve tracking and particle tracing show good in‐scan consistency and strong scan–rescan reproducibility, which indicates that both 4D flow MRI methods are reliable and can be used clinically.Level of Evidence: 2Technical Efficacy Stage: 2J. Magn. Reson. Imaging 2018;47:511–522.
- 22 June 2017
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 47 (2) , 511-522
Open AccessIn‐scan and scan–rescan assessment of LV in‐ and outflow volumes by 4D flow MRI versus 2D planimetry
Purpose: To evaluate the in‐scan and scan–rescan consistency of left ventricular (LV) in‐ and outflow assessment from 1) 2D planimetry; 2) 4D flow magnetic resonance imaging (MRI) with retrospective valve tracking, and 3) 4D flow MRI with particle tracing.Materials and Methods: Ten healthy volunteers (age 27 ± 3 years) underwent multislice cine short‐axis planimetry and whole‐heart 4D flow MRI on a 3T MRI scanner twice with repositioning between the scans. LV in‐ and outflow was compared from 1) 2D planimetry; 2) 4D flow MRI with retrospective valve tracking over the mitral valve (MV) and aortic valve (AV), and 3) 4D flow MRI with particle tracing through forward and backward integration of velocity data.Results: In‐scan consistency between MV and AV flow volumes is excellent for both 4D flow MRI methods with r ≥ 0.95 (P ≤ 0.001). In‐scan AV and MV flow by retrospective valve tracking shows good to excellent correlations versus AV and MV flow by particle tracing (r ≥ 0.81, P ≤ 0.004). Scan–rescan SV assessment by 2D planimetry shows excellent reproducibility (intraclass correlation [ICC] = 0.98, P < 0.001, coefficient of variation [CV] = 7%). Scan–rescan MV and AV flow volume assessment by retrospective valve tracking shows strong reproducibility (ICCs ≥ 0.89, P ≤ 0.05, CVs = 12%), as well as by forward and backward particle tracing (ICCs ≥ 0.90, P ≤ 0.001, CVs ≤ 11%). Multicomponent particle tracing shows good scan–rescan reproducibility (ICCs ≥ 0.81, P ≤ 0.007, CVs ≤ 16%).Conclusion: LV in‐ and outflow assessment by 2D planimetry and 4D flow MRI with retrospective valve tracking and particle tracing show good in‐scan consistency and strong scan–rescan reproducibility, which indicates that both 4D flow MRI methods are reliable and can be used clinically.Level of Evidence: 2Technical Efficacy Stage: 2J. Magn. Reson. Imaging 2018;47:511–522.