John E. Gillam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
John E. Gillam has a total of 220 co-authors. Here are the top co-authors by number of shared publications:
- Magdalena Rafecas
Universität zu Lübeck
30 shared publications - Josep Francisco Oliver
Instituto de Fisica Corpuscular, Universidad de Valencia, Edificio Institutos de Paterna, Apartado de Correos 22085, E-46071 Valencia, Valencia, SPAIN
22 shared publications - Gabriela Llosa
Instituto de Física Corpuscular (IFIC), CSIC-UV, Valencia, Spain
15 shared publications - Carlos Lacasta
Centro Mixto Universidad de Valencia - CSIC
14 shared publications - Carles Solaz
Instituto de Fisica Corpuscular
11 shared publications I. Torres-Espallardo
11 shared publications
Latest Publications
- 25 January 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (3) , 034001
Denoising non-steady state dynamic PET data using a feed-forward neural network
The quality of reconstructed dynamic PET images, as well as the statistical reliability of the estimated pharmacokinetic parameters is often compromised by high levels of statistical noise, particularly at the voxel level. Many denoising strategies have been proposed, both in the temporal and spatial domain, which substantially improve the signal to noise ratio of the reconstructed dynamic images. However, although most filtering approaches are fairly successful in reducing the spatio-temporal inter-voxel variability, they may also average out or completely eradicate the critically important temporal signature of a transient neurotransmitter activation response that may be present in a non-steady state dynamic PET study. In this work, we explore an approach towards temporal denoising of non-steady state dynamic PET images using an artificial neural network, which was trained to identify the temporal profile of a time-activity curve, while preserving any potential activation response. We evaluated the performance of a feed-forward perceptron neural network to improve the signal to noise ratio of dynamic [ 11 C]raclopride activation studies and compared it with the widely used highly constrained back projection (HYPR) filter. Results on both simulated Geant4 Application for Tomographic Emission data of a realistic rat brain phantom and experimental animal data of a freely moving animal study showed that the proposed neural network can efficiently improve the noise characteristics of dynamic data in the temporal domain, while it can lead to a more reliable estimation of voxel-wise activation response in target region. In addition, improvements in signal-to-noise ratio achieved by denoising the dynamic data using the proposed neural network led to improved accuracy and precision of the estimated model parameters of the lp-ntPET model, compared to the HYPR filter. The performance of the proposed denoising approach strongly depends on the amount of noise in the dynamic PET data, with higher noise leading to substantially higher variability in the estimated parameters of the activation response. Overall, the feed-forward network led to a similar performance as the HYPR filter in terms of spatial denoising, but led to notable improvements in terms of temporal denoising, which in turn improved the estimation activation parameters.
- 25 January 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (3) , 034001
Denoising non-steady state dynamic PET data using a feed-forward neural network
The quality of reconstructed dynamic PET images, as well as the statistical reliability of the estimated pharmacokinetic parameters is often compromised by high levels of statistical noise, particularly at the voxel level. Many denoising strategies have been proposed, both in the temporal and spatial domain, which substantially improve the signal to noise ratio of the reconstructed dynamic images. However, although most filtering approaches are fairly successful in reducing the spatio-temporal inter-voxel variability, they may also average out or completely eradicate the critically important temporal signature of a transient neurotransmitter activation response that may be present in a non-steady state dynamic PET study. In this work, we explore an approach towards temporal denoising of non-steady state dynamic PET images using an artificial neural network, which was trained to identify the temporal profile of a time-activity curve, while preserving any potential activation response. We evaluated the performance of a feed-forward perceptron neural network to improve the signal to noise ratio of dynamic [ 11 C]raclopride activation studies and compared it with the widely used highly constrained back projection (HYPR) filter. Results on both simulated Geant4 Application for Tomographic Emission data of a realistic rat brain phantom and experimental animal data of a freely moving animal study showed that the proposed neural network can efficiently improve the noise characteristics of dynamic data in the temporal domain, while it can lead to a more reliable estimation of voxel-wise activation response in target region. In addition, improvements in signal-to-noise ratio achieved by denoising the dynamic data using the proposed neural network led to improved accuracy and precision of the estimated model parameters of the lp-ntPET model, compared to the HYPR filter. The performance of the proposed denoising approach strongly depends on the amount of noise in the dynamic PET data, with higher noise leading to substantially higher variability in the estimated parameters of the activation response. Overall, the feed-forward network led to a similar performance as the HYPR filter in terms of spatial denoising, but led to notable improvements in terms of temporal denoising, which in turn improved the estimation activation parameters.
- 1 July 2020
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 122, 103797
Semi-supervised labelling of the femur in a whole-body post-mortem CT database using deep learning
- 1 July 2020
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 122, 103797
Semi-supervised labelling of the femur in a whole-body post-mortem CT database using deep learning
- 28 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (6) , 1371-1383
Direct Estimation of Voxel-Wise Neurotransmitter Response Maps From Dynamic PET Data
Computational methods, such as the linear parametric neurotransmitter PET (lp-ntPET) method, have been developed to characterize the transient changes in radiotracer kinetics in the target tissue during endogenous neurotransmitter release. In this paper, we describe and evaluate a parametric reconstruction algorithm that uses an expectation maximization framework, along with the lp-ntPET model, to estimate the endogenous neurotransmitter response to stimuli directly from the measured PET data. Computer simulations showed that the proposed direct reconstruction method offers improved accuracy and precision for the estimated timing parameters of the neurotransmitter response at the voxel level (t d = 1±2 min, for activation onset bias and standard deviation) compared with conventional post reconstruction modeling (t d = 4±7 min). In addition, we applied the proposed direct parameter estimation methodology to a [ 11 C]raclopride displacement study of an awake rat and generated parametric maps illustrating the magnitude of ligand displacement from striatum. Although the estimated parametric maps of activation magnitude obtained from both direct and post reconstruction methodologies suffered from false positive activations, the proposed direct reconstruction framework offered more reliable parametric maps when the activation onset parameter was constrained.
- 28 November 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 38 (6) , 1371-1383
Direct Estimation of Voxel-Wise Neurotransmitter Response Maps From Dynamic PET Data
Computational methods, such as the linear parametric neurotransmitter PET (lp-ntPET) method, have been developed to characterize the transient changes in radiotracer kinetics in the target tissue during endogenous neurotransmitter release. In this paper, we describe and evaluate a parametric reconstruction algorithm that uses an expectation maximization framework, along with the lp-ntPET model, to estimate the endogenous neurotransmitter response to stimuli directly from the measured PET data. Computer simulations showed that the proposed direct reconstruction method offers improved accuracy and precision for the estimated timing parameters of the neurotransmitter response at the voxel level (t d = 1±2 min, for activation onset bias and standard deviation) compared with conventional post reconstruction modeling (t d = 4±7 min). In addition, we applied the proposed direct parameter estimation methodology to a [ 11 C]raclopride displacement study of an awake rat and generated parametric maps illustrating the magnitude of ligand displacement from striatum. Although the estimated parametric maps of activation magnitude obtained from both direct and post reconstruction methodologies suffered from false positive activations, the proposed direct reconstruction framework offered more reliable parametric maps when the activation onset parameter was constrained.
- Open Access
- 23 March 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (3) , 035032
Image-based modelling of residual blurring in motion corrected small animal PET imaging using motion dependent point spread functions
Optical motion tracking and motion compensation reconstruction algorithms enable the acquisition of quantitative measurements of brain function on conscious and freely moving rodents. However, motion corrected images often exhibit reduced resolution when compared with their stationary counterparts. This apparent loss of resolution can be attributed, among others, to jitter/noise in the measured motion estimates and brief periods of fast animal motion with insufficient motion sampling rate. In this paper we propose a novel methodology to experimentally characterise the residual blurring in the motion corrected images by measuring the motion-dependent point spread function (PSF) in image space using a point source rigidly attached on the moving object. We evaluated the proposed methodology using experimental phantom measurements acquired on the microPET Focus220 scanner. The motion dependent point spread function was extracted from the point source attached on the moving phantom, after motion correcting the images and modelling the point source in image space using an Expectation Maximisation algorithm as a weighted sum of two Gaussian distributions. Finally, the fitted blurring kernels were used within an iterative Lucy-Richardson algorithm to mitigate the deblurring in the motion corrected images. For motion typically encountered in an awake rat study, results showed that unprocessed motion corrected images suffer from lower resolution compared to a stationary acquisition. The shape of the measured blurring kernel, correlated well with the motion trajectory, while the width of the kernel was proportional to the speed/acceleration of the object. Post-processed images using the corresponding motion dependent blurring kernel appeared not only qualitatively, but also quantitatively (in terms of contrast) more similar to their stationary counterpart. We conclude that it is possible to experimentally measure the residual motion-dependent blurring kernel and use it within a post reconstruction deconvolution framework to improve resolution and quantification of motion corrected images.
- 23 March 2018
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 4 (3) , 035032
Open AccessImage-based modelling of residual blurring in motion corrected small animal PET imaging using motion dependent point spread functions
Optical motion tracking and motion compensation reconstruction algorithms enable the acquisition of quantitative measurements of brain function on conscious and freely moving rodents. However, motion corrected images often exhibit reduced resolution when compared with their stationary counterparts. This apparent loss of resolution can be attributed, among others, to jitter/noise in the measured motion estimates and brief periods of fast animal motion with insufficient motion sampling rate. In this paper we propose a novel methodology to experimentally characterise the residual blurring in the motion corrected images by measuring the motion-dependent point spread function (PSF) in image space using a point source rigidly attached on the moving object. We evaluated the proposed methodology using experimental phantom measurements acquired on the microPET Focus220 scanner. The motion dependent point spread function was extracted from the point source attached on the moving phantom, after motion correcting the images and modelling the point source in image space using an Expectation Maximisation algorithm as a weighted sum of two Gaussian distributions. Finally, the fitted blurring kernels were used within an iterative Lucy-Richardson algorithm to mitigate the deblurring in the motion corrected images. For motion typically encountered in an awake rat study, results showed that unprocessed motion corrected images suffer from lower resolution compared to a stationary acquisition. The shape of the measured blurring kernel, correlated well with the motion trajectory, while the width of the kernel was proportional to the speed/acceleration of the object. Post-processed images using the corresponding motion dependent blurring kernel appeared not only qualitatively, but also quantitatively (in terms of contrast) more similar to their stationary counterpart. We conclude that it is possible to experimentally measure the residual motion-dependent blurring kernel and use it within a post reconstruction deconvolution framework to improve resolution and quantification of motion corrected images.
- Open Access
- 1 February 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 809, 76-88
Monte-Carlo simulations and image reconstruction for novel imaging scenarios in emission tomography
- 1 February 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 809, 76-88
Open AccessMonte-Carlo simulations and image reconstruction for novel imaging scenarios in emission tomography
- 17 April 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (9) , N187-N208
Evaluation of resistive-plate-chamber-based TOF-PET applied to in-beam particle therapy monitoring
Particle therapy is a highly conformal radiotherapy technique which reduces the dose deposited to the surrounding normal tissues. In order to fully exploit its advantages, treatment monitoring is necessary to minimize uncertainties related to the dose delivery. Up to now, the only clinically feasible technique for the monitoring of therapeutic irradiation with particle beams is Positron Emission Tomography (PET). In this work we have compared a Resistive Plate Chamber (RPC)-based PET scanner with a scintillation-crystal-based PET scanner for this application. In general, the main advantages of the RPC-PET system are its excellent timing resolution, low cost, and the possibility of building large area systems. We simulated a partial-ring scanner based on an RPC prototype under construction within the Fondazione per Adroterapia Oncologica (TERA). For comparison with the crystal-based PET scanner we have chosen the geometry of a commercially available PET scanner, the Philips Gemini TF. The coincidence time resolution used in the simulations takes into account the current achievable values as well as expected improvements of both technologies. Several scenarios (including patient data) have been simulated to evaluate the performance of different scanners. Initial results have shown that the low sensitivity of the RPC hampers its application to hadron-beam monitoring, which has an intrinsically low positron yield compared to diagnostic PET. In addition, for in-beam PET there is a further data loss due to the partial ring configuration. In order to improve the performance of the RPC-based scanner, an improved version of the RPC detector (modifying the thickness of the gas and glass layers), providing a larger sensitivity, has been simulated and compared with an axially extended version of the crystal-based device. The improved version of the RPC shows better performance than the prototype, but the extended version of the crystal-based PET outperforms all other options.
- 17 April 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (9) , N187-N208
Evaluation of resistive-plate-chamber-based TOF-PET applied to in-beam particle therapy monitoring
Particle therapy is a highly conformal radiotherapy technique which reduces the dose deposited to the surrounding normal tissues. In order to fully exploit its advantages, treatment monitoring is necessary to minimize uncertainties related to the dose delivery. Up to now, the only clinically feasible technique for the monitoring of therapeutic irradiation with particle beams is Positron Emission Tomography (PET). In this work we have compared a Resistive Plate Chamber (RPC)-based PET scanner with a scintillation-crystal-based PET scanner for this application. In general, the main advantages of the RPC-PET system are its excellent timing resolution, low cost, and the possibility of building large area systems. We simulated a partial-ring scanner based on an RPC prototype under construction within the Fondazione per Adroterapia Oncologica (TERA). For comparison with the crystal-based PET scanner we have chosen the geometry of a commercially available PET scanner, the Philips Gemini TF. The coincidence time resolution used in the simulations takes into account the current achievable values as well as expected improvements of both technologies. Several scenarios (including patient data) have been simulated to evaluate the performance of different scanners. Initial results have shown that the low sensitivity of the RPC hampers its application to hadron-beam monitoring, which has an intrinsically low positron yield compared to diagnostic PET. In addition, for in-beam PET there is a further data loss due to the partial ring configuration. In order to improve the performance of the RPC-based scanner, an improved version of the RPC detector (modifying the thickness of the gas and glass layers), providing a larger sensitivity, has been simulated and compared with an axially extended version of the crystal-based device. The improved version of the RPC shows better performance than the prototype, but the extended version of the crystal-based PET outperforms all other options.
- 6 February 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (5) , 1845-1863
Noise evaluation of Compton camera imaging for proton therapy
Compton Cameras emerged as an alternative for real-time dose monitoring techniques for Particle Therapy (PT), based on the detection of prompt-gammas. As a consequence of the Compton scattering process, the gamma origin point can be restricted onto the surface of a cone (Compton cone). Through image reconstruction techniques, the distribution of the gamma emitters can be estimated, using cone-surfaces backprojections of the Compton cones through the image space, along with more sophisticated statistical methods to improve the image quality. To calculate the Compton cone required for image reconstruction, either two interactions, the last being photoelectric absorption, or three scatter interactions are needed. Because of the high energy of the photons in PT the first option might not be adequate, as the photon is not absorbed in general. However, the second option is less efficient. That is the reason to resort to spectral reconstructions, where the incoming γ energy is considered as a variable in the reconstruction inverse problem. Jointly with prompt gamma, secondary neutrons and scattered photons, not strongly correlated with the dose map, can also reach the imaging detector and produce false events. These events deteriorate the image quality. Also, high intensity beams can produce particle accumulation in the camera, which lead to an increase of random coincidences, meaning events which gather measurements from different incoming particles. The noise scenario is expected to be different if double or triple events are used, and consequently, the reconstructed images can be affected differently by spurious data. The aim of the present work is to study the effect of false events in the reconstructed image, evaluating their impact in the determination of the beam particle ranges. A simulation study that includes misidentified events (neutrons and random coincidences) in the final image of a Compton Telescope for PT monitoring is presented. The complete chain of detection, from the beam particle entering a phantom to the event classification, is simulated using FLUKA. The range determination is later estimated from the reconstructed image obtained from a two and three-event algorithm based on Maximum Likelihood Expectation Maximization. The neutron background and random coincidences due to a therapeutic-like time structure are analyzed for mono-energetic proton beams. The time structure of the beam is included in the simulations, which will affect the rate of particles entering the detector.
- 6 February 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (5) , 1845-1863
Noise evaluation of Compton camera imaging for proton therapy
Compton Cameras emerged as an alternative for real-time dose monitoring techniques for Particle Therapy (PT), based on the detection of prompt-gammas. As a consequence of the Compton scattering process, the gamma origin point can be restricted onto the surface of a cone (Compton cone). Through image reconstruction techniques, the distribution of the gamma emitters can be estimated, using cone-surfaces backprojections of the Compton cones through the image space, along with more sophisticated statistical methods to improve the image quality. To calculate the Compton cone required for image reconstruction, either two interactions, the last being photoelectric absorption, or three scatter interactions are needed. Because of the high energy of the photons in PT the first option might not be adequate, as the photon is not absorbed in general. However, the second option is less efficient. That is the reason to resort to spectral reconstructions, where the incoming γ energy is considered as a variable in the reconstruction inverse problem. Jointly with prompt gamma, secondary neutrons and scattered photons, not strongly correlated with the dose map, can also reach the imaging detector and produce false events. These events deteriorate the image quality. Also, high intensity beams can produce particle accumulation in the camera, which lead to an increase of random coincidences, meaning events which gather measurements from different incoming particles. The noise scenario is expected to be different if double or triple events are used, and consequently, the reconstructed images can be affected differently by spurious data. The aim of the present work is to study the effect of false events in the reconstructed image, evaluating their impact in the determination of the beam particle ranges. A simulation study that includes misidentified events (neutrons and random coincidences) in the final image of a Compton Telescope for PT monitoring is presented. The complete chain of detection, from the beam particle entering a phantom to the event classification, is simulated using FLUKA. The range determination is later estimated from the reconstructed image obtained from a two and three-event algorithm based on Maximum Likelihood Expectation Maximization. The neutron background and random coincidences due to a therapeutic-like time structure are analyzed for mono-energetic proton beams. The time structure of the beam is included in the simulations, which will affect the rate of particles entering the detector.
- 21 November 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (24) , 7587-7600
Towards optimal imaging with PET: anin silicofeasibility study
The efficacy of Positron Emission Tomography (PET) imaging relies fundamentally on the ability of the system to accurately identify true coincidence events. With existing systems, this is currently accomplished with an energy acceptance criterion followed by correction techniques to remove suspected false coincidence events. These corrections generally result in signal and contrast loss and thus limit the PET system's ability to achieve optimum image quality. A key property of annihilation radiation is that the photons are polarised with respect to each other. This polarisation correlation offers a potentially powerful discriminator, independent of energy, to accurately identify true events. In this proof of concept study, we investigate how photon polarisation information can be exploited in PET imaging by developing a method to discriminate true coincidences using the polarisation correlation of annihilation pairs. We implement this method using a Geant4 PET simulation of a GE Advance/Discovery LS system and demonstrate the potential advantages of the polarisation coincidence selection method over a standard energy criterion method. Current PET ring detectors are not capable of exploiting the polarisation correlation of the photon pairs. Compton PET systems, however are promising candidates for this application. We demonstrate the feasibility of a two-component Compton camera system in identifying true coincidences with Monte Carlo simulations. Our study demonstrates the potential of improving signal gain using polarisation, particularly for high photon emission rates. We also demonstrate the ability of the Compton camera at exploiting this polarisation correlation in PET.
- 21 November 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 59 (24) , 7587-7600
Towards optimal imaging with PET: anin silicofeasibility study
The efficacy of Positron Emission Tomography (PET) imaging relies fundamentally on the ability of the system to accurately identify true coincidence events. With existing systems, this is currently accomplished with an energy acceptance criterion followed by correction techniques to remove suspected false coincidence events. These corrections generally result in signal and contrast loss and thus limit the PET system's ability to achieve optimum image quality. A key property of annihilation radiation is that the photons are polarised with respect to each other. This polarisation correlation offers a potentially powerful discriminator, independent of energy, to accurately identify true events. In this proof of concept study, we investigate how photon polarisation information can be exploited in PET imaging by developing a method to discriminate true coincidences using the polarisation correlation of annihilation pairs. We implement this method using a Geant4 PET simulation of a GE Advance/Discovery LS system and demonstrate the potential advantages of the polarisation coincidence selection method over a standard energy criterion method. Current PET ring detectors are not capable of exploiting the polarisation correlation of the photon pairs. Compton PET systems, however are promising candidates for this application. We demonstrate the feasibility of a two-component Compton camera system in identifying true coincidences with Monte Carlo simulations. Our study demonstrates the potential of improving signal gain using polarisation, particularly for high photon emission rates. We also demonstrate the ability of the Compton camera at exploiting this polarisation correlation in PET.
- 1 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Feasibility of motion-corrected planar projection imaging of single photon emitters: A phantom study
The kinetics of single photon emitting macromolecules (e.g. antibodies) are typically slower than small molecules, necessitating long or repeat acquisitions. We previously proposed the use of motion tracking and limited angle tomographic reconstruction to characterise tracer kinetics over extended periods in awake rodents. In this study, we explored this approach by imaging a contrast phantom, moved with 6 degrees of freedom, using a prototype preclinical SPECT scanner with parallel-hole collimation and a fixed detector located at 0 and 90 degrees. The position of the phantom was tracked and data were acquired in list mode. Each event was motion-corrected and reconstructed using LM-MLEM. Planar projections were created by summing the reconstructed volume along the x-axis. Line profiles of the contrast phantom were compared for a planar reference projection and projections generated from the motion-free, motion-corrupted and motion-corrected reconstructions. Projections created from the motion-corrected agreed well with the planar reference projection of the stationary object and exhibited similar contrast. Whilst this initial study was limited to rigid motion, it demonstrates the feasibility of motion-corrected planar projections of a moving object.
- 1 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-3
Feasibility of motion-corrected planar projection imaging of single photon emitters: A phantom study
The kinetics of single photon emitting macromolecules (e.g. antibodies) are typically slower than small molecules, necessitating long or repeat acquisitions. We previously proposed the use of motion tracking and limited angle tomographic reconstruction to characterise tracer kinetics over extended periods in awake rodents. In this study, we explored this approach by imaging a contrast phantom, moved with 6 degrees of freedom, using a prototype preclinical SPECT scanner with parallel-hole collimation and a fixed detector located at 0 and 90 degrees. The position of the phantom was tracked and data were acquired in list mode. Each event was motion-corrected and reconstructed using LM-MLEM. Planar projections were created by summing the reconstructed volume along the x-axis. Line profiles of the contrast phantom were compared for a planar reference projection and projections generated from the motion-free, motion-corrupted and motion-corrected reconstructions. Projections created from the motion-corrected agreed well with the planar reference projection of the stationary object and exhibited similar contrast. Whilst this initial study was limited to rigid motion, it demonstrates the feasibility of motion-corrected planar projections of a moving object.
- 1 November 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 338, 77-88
A low energy bound atomic electron Compton scattering model for Geant4
- 1 November 2014
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 338, 77-88
A low energy bound atomic electron Compton scattering model for Geant4