Yanting Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yanting Han has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Ka Li
Medicine and Engineering Interdisciplinary Research Laboratory of Nursing & Materials, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
8 shared publications Zhe Yin
Department of Gastroenterology, Affiliated Tumor Hospital of Xinjiang Medical University 3 , Urumqi 830000
4 shared publications- Tingting Hu
Medicine and Engineering Interdisciplinary Research Laboratory of Nursing & Materials West China Hospital Sichuan University/West China School of Nursing Sichuan University Chengdu China
3 shared publications - Hongli Zhang
West China School of Nursing Sichuan University/West China Hospital Sichuan University Chengdu China scu.edu.cn
2 shared publications - Jinlian Hu
Department of Biomedical Engineering, City University of Hong Kong, Kowloon, China
2 shared publications Ka Li
Medicine and Engineering Interdisciplinary Research Laboratory of Nursing and Materials, West China Hospital Sichuan University Chengdu China
2 shared publications
Latest Publications
Bionic Protein Bond Constraint‐Reinforced and Enriched Multifunctional Hydrogel Coating for Invasive Medical Devices
Dual‐targeted strategies addressing both infection and trauma from invasive devices are imperative. Herein, we developed a bionic protein bond constraint strategy to construct multifunctional quaternary ammonium hydrogel coatings (BEAC). Inspired by the secondary bonds stabilizing the protein tertiary structure, BEAC was synthesized by integrating acryloyloxyethyl trimethylammonium chloride (DAC) with amide‐rich hydrophilic components. This architecture establishes bionic bond constraints via hydrogen bonding, ion‒dipole interactions, van der Waals forces, etc. The robust BEAC results in a 280% increase in tensile strength over that of the DAC, a low friction coefficient (0.08), and a tissue‐matching surface modulus (198.7 kPa). Furthermore, BEAC promotes the surface enrichment of quaternary ammonium, ensuring superior antifouling, with an antibacterial rate exceeding 99.6%. Consequently, BEAC‐modified nasogastric and urinary catheters significantly mitigate foreign body responses and infection risks through dual‐action protection. This work provides a promising strategy for designing multifunctional hydrogel coatings, with potential applications for various invasive devices.
Bionic Protein Bond Constraint‐Reinforced and Enriched Multifunctional Hydrogel Coating for Invasive Medical Devices
Dual‐targeted strategies addressing both infection and trauma from invasive devices are imperative. Herein, we developed a bionic protein bond constraint strategy to construct multifunctional quaternary ammonium hydrogel coatings (BEAC). Inspired by the secondary bonds stabilizing the protein tertiary structure, BEAC was synthesized by integrating acryloyloxyethyl trimethylammonium chloride (DAC) with amide‐rich hydrophilic components. This architecture establishes bionic bond constraints via hydrogen bonding, ion‒dipole interactions, van der Waals forces, etc. The robust BEAC results in a 280% increase in tensile strength over that of the DAC, a low friction coefficient (0.08), and a tissue‐matching surface modulus (198.7 kPa). Furthermore, BEAC promotes the surface enrichment of quaternary ammonium, ensuring superior antifouling, with an antibacterial rate exceeding 99.6%. Consequently, BEAC‐modified nasogastric and urinary catheters significantly mitigate foreign body responses and infection risks through dual‐action protection. This work provides a promising strategy for designing multifunctional hydrogel coatings, with potential applications for various invasive devices.
- 5 August 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (56)
An On‐Skin Visually Monitorable Gel‐Matrix Zinc–Ion Battery for Electrically Stimulated Wound Healing
Aqueous zinc‐ion batteries (ZIBs) feature intrinsic safety, low cost, and environmental compatibility, making them attractive for untapped cutting‐edge applications, such as the biomedicine area. Particularly, wearable medical power sources require stable electrical output, mechanical flexibility, and high biocompatibility. Herein, a stable and flexible gel‐matrix aqueous ZIB was designed as an on‐skin power source for electrically stimulated wound healing. The elaborately designed graded porous framework hydrogel electrolyte (GPF‐HGE) obtains high ionic conductivity (17.19 mS cm −1 ) and improved mechanical deformation tolerance (46 kPa and 205 J m −2 ) due to the porous framework formed in the solvent exchange process. Its transparency property, combined with an annular ring‐shaped electrode that generates an electric field aligned with the endogenous wound electric field, enables direct application to wound sites and real‐time visual monitoring. The assembled Zn|GPF‐HGE|I 2 @AC full cells show superior long‐term cycling stability accompanied by slight capacity fading, ensuring a steady energy supply for electrical stimulation (ES). Benefiting from its robust electrochemical stability and excellent biocompatibility, the obtained ES device can provide reliable electrical signals and promote wound healing through synergistic antibacterial and anti‐inflammatory effects. This work highlights the potential of aqueous ZIBs as advanced biomedical power sources beyond conventional energy storage applications.
- 5 August 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (56)
An On‐Skin Visually Monitorable Gel‐Matrix Zinc–Ion Battery for Electrically Stimulated Wound Healing
Aqueous zinc‐ion batteries (ZIBs) feature intrinsic safety, low cost, and environmental compatibility, making them attractive for untapped cutting‐edge applications, such as the biomedicine area. Particularly, wearable medical power sources require stable electrical output, mechanical flexibility, and high biocompatibility. Herein, a stable and flexible gel‐matrix aqueous ZIB was designed as an on‐skin power source for electrically stimulated wound healing. The elaborately designed graded porous framework hydrogel electrolyte (GPF‐HGE) obtains high ionic conductivity (17.19 mS cm −1 ) and improved mechanical deformation tolerance (46 kPa and 205 J m −2 ) due to the porous framework formed in the solvent exchange process. Its transparency property, combined with an annular ring‐shaped electrode that generates an electric field aligned with the endogenous wound electric field, enables direct application to wound sites and real‐time visual monitoring. The assembled Zn|GPF‐HGE|I 2 @AC full cells show superior long‐term cycling stability accompanied by slight capacity fading, ensuring a steady energy supply for electrical stimulation (ES). Benefiting from its robust electrochemical stability and excellent biocompatibility, the obtained ES device can provide reliable electrical signals and promote wound healing through synergistic antibacterial and anti‐inflammatory effects. This work highlights the potential of aqueous ZIBs as advanced biomedical power sources beyond conventional energy storage applications.
- Open Access
- 9 April 2026
- Published by AIP Publishing in APL Bioengineering
- Vol. 10 (2)
Research progress in flap temperature monitoring technologies and applications after transplantation
As a primary method for tissue repair and functional reconstruction, flap transplantation has achieved a clinical success rate of over 90%. However, the postoperative incidence of vascular crisis remains as high as 10%–30%, making it a leading cause of reoperation and disability. Flap temperature is a key indicator closely correlated with microcirculatory status, making its monitoring essential for the early detection of complications. This paper provides a systematic review of the physiological mechanisms underlying postoperative flap temperature, the characteristic temperature changes associated with venous and arterial crises, and the latest advancements in monitoring technologies. It comprehensively analyzes the principles, advantages, and limitations of various methods, including manual palpation, contact thermometry, infrared thermography, fiber optic sensing, and microwave thermometry. Furthermore, the review explores the application of intelligent technologies such as wearable sensors, artificial intelligence-driven predictive systems, implantable flexible devices, and multimodal fusion monitoring. Current challenges, including poor real-time performance, low precision, and a lack of standardization, are highlighted. Future development is directed toward precision, intelligence, and integration, with an emphasis on multidisciplinary collaboration to create more accurate, convenient, and intelligent monitoring systems. These advancements aim to achieve precise early warning and timely intervention, ultimately improving flap survival rates and patient outcomes.
- 9 April 2026
- Published by AIP Publishing in APL Bioengineering
- Vol. 10 (2)
Open AccessResearch progress in flap temperature monitoring technologies and applications after transplantation
As a primary method for tissue repair and functional reconstruction, flap transplantation has achieved a clinical success rate of over 90%. However, the postoperative incidence of vascular crisis remains as high as 10%–30%, making it a leading cause of reoperation and disability. Flap temperature is a key indicator closely correlated with microcirculatory status, making its monitoring essential for the early detection of complications. This paper provides a systematic review of the physiological mechanisms underlying postoperative flap temperature, the characteristic temperature changes associated with venous and arterial crises, and the latest advancements in monitoring technologies. It comprehensively analyzes the principles, advantages, and limitations of various methods, including manual palpation, contact thermometry, infrared thermography, fiber optic sensing, and microwave thermometry. Furthermore, the review explores the application of intelligent technologies such as wearable sensors, artificial intelligence-driven predictive systems, implantable flexible devices, and multimodal fusion monitoring. Current challenges, including poor real-time performance, low precision, and a lack of standardization, are highlighted. Future development is directed toward precision, intelligence, and integration, with an emphasis on multidisciplinary collaboration to create more accurate, convenient, and intelligent monitoring systems. These advancements aim to achieve precise early warning and timely intervention, ultimately improving flap survival rates and patient outcomes.
- Open Access
- 25 February 2026
- Published by AIP Publishing in APL Bioengineering
- Vol. 10 (1)
New concept in wound infection management: From bacterial eradication to microbiome modulation
Wound infection represents a significant challenge in clinical practice. Traditional wound management, targeting sterility and relying on strategies of broad-spectrum bactericidal activity and antibiotic dependence, achieves partial infection control but induces severe complications, including exacerbated bacterial resistance and skin microbiota dysbiosis. With the continuous advancement of microbiome research, a novel consensus has emerged: the key to wound healing lies not in the complete eradication of all microorganisms but in maintaining the dynamic balance of the microbial ecosystem. This review aims to elaborate on the paradigm shift from “bactericidal eradication” to “microbial modulation” in wound care, analyze the inherent limitations of conventional antibacterial strategies, and systematically summarize the critical roles of skin commensal microbiota in promoting wound healing through core mechanisms such as competitive inhibition, metabolic regulation, and immune modulation. Furthermore, it proposes that the core strategy of future wound care should focus on precision microbial modulation and discusses the application prospects of cutting-edge technologies, including probiotics, postbiotics, and individualized precision interventions. The innovative significance of this paradigm in wound dressing design is envisaged, emphasizing the development of novel materials integrating microbiota-specific regulatory capabilities and smart responsive functions. This work provides theoretical support for the precision prevention and control of wound infections, the improvement of healing quality, and technological innovation in the field of wound care.
- 25 February 2026
- Published by AIP Publishing in APL Bioengineering
- Vol. 10 (1)
Open AccessNew concept in wound infection management: From bacterial eradication to microbiome modulation
Wound infection represents a significant challenge in clinical practice. Traditional wound management, targeting sterility and relying on strategies of broad-spectrum bactericidal activity and antibiotic dependence, achieves partial infection control but induces severe complications, including exacerbated bacterial resistance and skin microbiota dysbiosis. With the continuous advancement of microbiome research, a novel consensus has emerged: the key to wound healing lies not in the complete eradication of all microorganisms but in maintaining the dynamic balance of the microbial ecosystem. This review aims to elaborate on the paradigm shift from “bactericidal eradication” to “microbial modulation” in wound care, analyze the inherent limitations of conventional antibacterial strategies, and systematically summarize the critical roles of skin commensal microbiota in promoting wound healing through core mechanisms such as competitive inhibition, metabolic regulation, and immune modulation. Furthermore, it proposes that the core strategy of future wound care should focus on precision microbial modulation and discusses the application prospects of cutting-edge technologies, including probiotics, postbiotics, and individualized precision interventions. The innovative significance of this paradigm in wound dressing design is envisaged, emphasizing the development of novel materials integrating microbiota-specific regulatory capabilities and smart responsive functions. This work provides theoretical support for the precision prevention and control of wound infections, the improvement of healing quality, and technological innovation in the field of wound care.
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Nursing Management
- Vol. 2026 (1)
From Compromise to Burnout: Understanding Potential Pathways Linking Career Compromise and Burnout Among Novice Nurses via Latent Profile Analysis and Mediation Analysis
Background: Retention of novice nurses is a key strategy for alleviating nursing shortages and ensuring the sustainability of the nursing profession. During the transition to clinical practice, novice nurses face unique challenges and may experience career compromise when attempting to reconcile their career expectations with workplace realities. Career compromise has been associated with burnout and even turnover. However, career compromise among novice nurses has received insufficient research attention. This study aimed to identify profiles of career compromise among novice nurses and examine the role of occupational identity in the relationship between different career compromise profiles and burnout, thereby providing insights for improving novice nurse retention. Methods: A cross‐sectional survey was conducted from August to December 2025. A total of 570 novice nurses completed an online questionnaire that collected demographic information and included the Career Compromise Scale, Occupational Identity Scale, and Burnout Scale. Latent profile analysis was used to identify career compromise profiles. Univariate and logistic regression analyses were conducted to examine factors statistically associated with profile membership. Finally, the potential statistical indirect association involving occupational identity between career compromise profiles and burnout was examined. Results: Three career compromise profiles were identified: a low career compromise profile ( n = 211, 37.0%), a moderate career compromise profile ( n = 169, 29.6%), and a high career compromise profile ( n = 190, 33.3%). Gender, marital status, educational level, monthly income, employment form, working time every day (hours), interested in nursing, and having the thought to resign were statistically associated with profile membership. Analysis of statistical indirect associations showed that, compared with the low career compromise profile, both the moderate and high career compromise profiles were associated with lower occupational identity and higher burnout. Conclusions: Novice nurses exhibited career compromise profiles reflecting different levels of career compromise, with approximately two‐thirds experiencing moderate or high levels of career compromise. Occupational identity partially accounted for the observed association between career compromise profiles and burnout. Occupational identity may partially account for the observed association between career compromise profiles and burnout, with a statistically significant indirect association. Identifying sociodemographic and work‐related factors associated with career compromise and providing tailored support for nurses with different career compromise profiles may help inform interventions addressing career compromise and burnout among novice nurses. However, the effectiveness of such interventions requires evaluation in longitudinal and intervention studies. Implications for Nursing Management: Assessing subgroups of novice nurses according to their career compromise profiles can inform hypothesis‐generating and potentially targeted support strategies and promote continuous improvement. Supporting early career adaptation and considering occupational identity in support strategies may be relevant to burnout and novice nurse retention. The potential value of such approaches should be evaluated in prospective and intervention studies before implementation.
- 1 January 2026
- Published by Wiley in Journal of Nursing Management
- Vol. 2026 (1)
Open AccessFrom Compromise to Burnout: Understanding Potential Pathways Linking Career Compromise and Burnout Among Novice Nurses via Latent Profile Analysis and Mediation Analysis
Background: Retention of novice nurses is a key strategy for alleviating nursing shortages and ensuring the sustainability of the nursing profession. During the transition to clinical practice, novice nurses face unique challenges and may experience career compromise when attempting to reconcile their career expectations with workplace realities. Career compromise has been associated with burnout and even turnover. However, career compromise among novice nurses has received insufficient research attention. This study aimed to identify profiles of career compromise among novice nurses and examine the role of occupational identity in the relationship between different career compromise profiles and burnout, thereby providing insights for improving novice nurse retention. Methods: A cross‐sectional survey was conducted from August to December 2025. A total of 570 novice nurses completed an online questionnaire that collected demographic information and included the Career Compromise Scale, Occupational Identity Scale, and Burnout Scale. Latent profile analysis was used to identify career compromise profiles. Univariate and logistic regression analyses were conducted to examine factors statistically associated with profile membership. Finally, the potential statistical indirect association involving occupational identity between career compromise profiles and burnout was examined. Results: Three career compromise profiles were identified: a low career compromise profile ( n = 211, 37.0%), a moderate career compromise profile ( n = 169, 29.6%), and a high career compromise profile ( n = 190, 33.3%). Gender, marital status, educational level, monthly income, employment form, working time every day (hours), interested in nursing, and having the thought to resign were statistically associated with profile membership. Analysis of statistical indirect associations showed that, compared with the low career compromise profile, both the moderate and high career compromise profiles were associated with lower occupational identity and higher burnout. Conclusions: Novice nurses exhibited career compromise profiles reflecting different levels of career compromise, with approximately two‐thirds experiencing moderate or high levels of career compromise. Occupational identity partially accounted for the observed association between career compromise profiles and burnout. Occupational identity may partially account for the observed association between career compromise profiles and burnout, with a statistically significant indirect association. Identifying sociodemographic and work‐related factors associated with career compromise and providing tailored support for nurses with different career compromise profiles may help inform interventions addressing career compromise and burnout among novice nurses. However, the effectiveness of such interventions requires evaluation in longitudinal and intervention studies. Implications for Nursing Management: Assessing subgroups of novice nurses according to their career compromise profiles can inform hypothesis‐generating and potentially targeted support strategies and promote continuous improvement. Supporting early career adaptation and considering occupational identity in support strategies may be relevant to burnout and novice nurse retention. The potential value of such approaches should be evaluated in prospective and intervention studies before implementation.
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Nursing Management
- Vol. 2026 (1) , 4685274
Patterns and Predictors of Self‐Regulatory Fatigue Among Intensive Care Unit Nurses: A Person‐Centered Latent Profile Analysis
Background: Intensive care units (ICUs) play a critical role in the public health emergency response system. ICU nurses are the backbone of critical care and must continuously engage in self‐regulation while working in highly demanding environments, which may lead to self‐regulatory fatigue. Self‐regulatory fatigue may affect work engagement and patient safety. However, little is known about the profiles of self‐regulatory fatigue among ICU nurses and the factors associated with profile membership. Objective: To identify profiles of self‐regulatory fatigue among ICU nurses and examine factors associated with profile membership. Methods: A cross‐sectional survey was conducted between February and August 2025. A total of 687 ICU nurses completed an online questionnaire that collected general demographic information and assessed self‐regulatory fatigue, surface acting, and work engagement. Differences among latent profiles were examined using descriptive statistics, univariable analyses, and logistic regression analyses. Results: Three latent profiles were identified: “Low self‐regulatory fatigue (Class 1),” “Moderate self‐regulatory fatigue (Class 2),” and “High self‐regulatory fatigue (Class 3),” accounting for 32.3%, 52.7%, and 15.0%, respectively. In multivariable logistic regression analyses, lower work engagement was independently associated with membership in the moderate self‐regulatory fatigue profile compared with the low self‐regulatory fatigue profile. However, work engagement was not independently associated with membership in the high self‐regulatory fatigue profile compared with the low self‐regulatory fatigue profile. Associations of demographic and work‐related factors with profile membership differed across the comparisons. Conclusion: The level of self‐regulatory fatigue among ICU nurses showed a heterogeneous distribution, with over two‐thirds of the participants classified into the moderate or high self‐regulatory fatigue profiles. Identifying the sociodemographic and work‐related predictors associated with self‐regulatory fatigue profiles can facilitate the implementation of tailored interventions for specific subgroups and improve their effectiveness. Implications for Nursing Management: The findings may help nursing managers understand the heterogeneous profiles of self‐regulatory fatigue among ICU nurses. Identifying different profiles of self‐regulatory fatigue may inform targeted strategies to alleviate such fatigue and promote continuous quality improvement.
- 1 January 2026
- Published by Wiley in Journal of Nursing Management
- Vol. 2026 (1) , 4685274
Open AccessPatterns and Predictors of Self‐Regulatory Fatigue Among Intensive Care Unit Nurses: A Person‐Centered Latent Profile Analysis
Background: Intensive care units (ICUs) play a critical role in the public health emergency response system. ICU nurses are the backbone of critical care and must continuously engage in self‐regulation while working in highly demanding environments, which may lead to self‐regulatory fatigue. Self‐regulatory fatigue may affect work engagement and patient safety. However, little is known about the profiles of self‐regulatory fatigue among ICU nurses and the factors associated with profile membership. Objective: To identify profiles of self‐regulatory fatigue among ICU nurses and examine factors associated with profile membership. Methods: A cross‐sectional survey was conducted between February and August 2025. A total of 687 ICU nurses completed an online questionnaire that collected general demographic information and assessed self‐regulatory fatigue, surface acting, and work engagement. Differences among latent profiles were examined using descriptive statistics, univariable analyses, and logistic regression analyses. Results: Three latent profiles were identified: “Low self‐regulatory fatigue (Class 1),” “Moderate self‐regulatory fatigue (Class 2),” and “High self‐regulatory fatigue (Class 3),” accounting for 32.3%, 52.7%, and 15.0%, respectively. In multivariable logistic regression analyses, lower work engagement was independently associated with membership in the moderate self‐regulatory fatigue profile compared with the low self‐regulatory fatigue profile. However, work engagement was not independently associated with membership in the high self‐regulatory fatigue profile compared with the low self‐regulatory fatigue profile. Associations of demographic and work‐related factors with profile membership differed across the comparisons. Conclusion: The level of self‐regulatory fatigue among ICU nurses showed a heterogeneous distribution, with over two‐thirds of the participants classified into the moderate or high self‐regulatory fatigue profiles. Identifying the sociodemographic and work‐related predictors associated with self‐regulatory fatigue profiles can facilitate the implementation of tailored interventions for specific subgroups and improve their effectiveness. Implications for Nursing Management: The findings may help nursing managers understand the heterogeneous profiles of self‐regulatory fatigue among ICU nurses. Identifying different profiles of self‐regulatory fatigue may inform targeted strategies to alleviate such fatigue and promote continuous quality improvement.
- 4 September 2025
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 12 (24) , 10806-10818
Highly elastic and breathable PTFE/hydrogel hierarchically compounded dressings for multi-functional protection and rapid wound healing
Accelerating wound healing while reducing patient discomfort remains a major challenge in biomedical engineering.
- 4 September 2025
- Published by Royal Society of Chemistry (RSC) in Materials Horizons
- Vol. 12 (24) , 10806-10818
Highly elastic and breathable PTFE/hydrogel hierarchically compounded dressings for multi-functional protection and rapid wound healing
Accelerating wound healing while reducing patient discomfort remains a major challenge in biomedical engineering.
- Open Access
- 29 March 2025
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 25 (1) , 1-14
Accurate prediction of mediolateral episiotomy risk during labor: development and verification of an artificial intelligence model
The study developed an intelligent online evaluation system for mediolateral episiotomy, which incorporated machine learning algorithms and integrated maternal physiological data collected during delivery. In this study, a predictive model for mediolateral episiotomy was constructed first, and based on this, an early warning system using open-source R software was established. The physiological data of 1191 parturients who delivered at Deyang People's Hospital in western China from January 2022 to December 2022 were collected and divided into training set and test set according to a ratio of 8:2. The factors affecting mediolateral episiotomy were determined based on the expert consultation method. Six machine learning models, namely Logistic regression(LR), Support Vector Machine(SVM), K-Nearest Neighb(KNN), Random Forest (RF), Light Gradient Boosting Machine(LightGBM), and eXtreme Gradient Boosting(XGBoost) were constructed on this basis. The models’ performance was evaluated using accuracy, precision, recall, F1 value, and area under the receiver operating characteristic curve (AUC) measures. Additionally, a confusion matrix was employed to assess their performance across different categories. SHapley Additive exPlanation (SHAP) provided interpretability. The clinical external verification process focused on data collected from January to March 2023, and an intelligent online evaluation system for mediolateral episiotomy was developed. Twenty eight factors influencing mediolateral episiotomy were screened. The model evaluation results showed that the SVM model has the best prediction ability among the six models, with an accuracy of 0.793, a recall rate of 0.981, a precision rate of 0.790, and a F1 value of 0.875. The area under ROC curve of SVM was 0.882, The verification results showed that the prediction accuracy was 74% for undergoing mediolateral episiotomy and 93% for not undergoing it. SHAP analysis identified perineal elasticity, number of pregnancies, BMI, perineum edema, and age as top predictors. An early warning system for mediolateral episiotomy was successfully constructed, which can assist the clinical medical staff in decision-making by inputting the maternal data. The early warning system for the risk of mediolateral episiotomy constructed in this study can accurately and rapidly utilize the physiological data of parturients during labor to predict the risk of mediolateral episiotomy in the third stage of labor.
- 29 March 2025
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 25 (1) , 1-14
Open AccessAccurate prediction of mediolateral episiotomy risk during labor: development and verification of an artificial intelligence model
The study developed an intelligent online evaluation system for mediolateral episiotomy, which incorporated machine learning algorithms and integrated maternal physiological data collected during delivery. In this study, a predictive model for mediolateral episiotomy was constructed first, and based on this, an early warning system using open-source R software was established. The physiological data of 1191 parturients who delivered at Deyang People's Hospital in western China from January 2022 to December 2022 were collected and divided into training set and test set according to a ratio of 8:2. The factors affecting mediolateral episiotomy were determined based on the expert consultation method. Six machine learning models, namely Logistic regression(LR), Support Vector Machine(SVM), K-Nearest Neighb(KNN), Random Forest (RF), Light Gradient Boosting Machine(LightGBM), and eXtreme Gradient Boosting(XGBoost) were constructed on this basis. The models’ performance was evaluated using accuracy, precision, recall, F1 value, and area under the receiver operating characteristic curve (AUC) measures. Additionally, a confusion matrix was employed to assess their performance across different categories. SHapley Additive exPlanation (SHAP) provided interpretability. The clinical external verification process focused on data collected from January to March 2023, and an intelligent online evaluation system for mediolateral episiotomy was developed. Twenty eight factors influencing mediolateral episiotomy were screened. The model evaluation results showed that the SVM model has the best prediction ability among the six models, with an accuracy of 0.793, a recall rate of 0.981, a precision rate of 0.790, and a F1 value of 0.875. The area under ROC curve of SVM was 0.882, The verification results showed that the prediction accuracy was 74% for undergoing mediolateral episiotomy and 93% for not undergoing it. SHAP analysis identified perineal elasticity, number of pregnancies, BMI, perineum edema, and age as top predictors. An early warning system for mediolateral episiotomy was successfully constructed, which can assist the clinical medical staff in decision-making by inputting the maternal data. The early warning system for the risk of mediolateral episiotomy constructed in this study can accurately and rapidly utilize the physiological data of parturients during labor to predict the risk of mediolateral episiotomy in the third stage of labor.
- 6 November 2024
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 113 (1)
Shape Memory Polyurethane Foams With Tunable Mechanical Properties and Radiation Tolerance for Breast Repair and Reconstruction
This study developed a shape memory polyurethane foam (SM‐PUF) with tunable mechanical properties and exceptional radiation tolerance for potentially implanting tissue defects after mastectomy. The PUFs were synthesized via an in situ foaming strategy using water as a foaming agent, incorporating 4,4′‐diphenylmethane diisocyanate (MDI) as the rigid segment and both polyoxytetramethylene glycol and polycaprolactone as the soft segment. The resultant PUFs possess an open‐cell structure with a pore size of 30 ~ 800 μm, which achieves a compressive stress of 0.04 MPa under 70% compression strain and a tensile elongation of 667.9%. PUFs exhibit body temperature (37°C)‐responsive softening and shape memory abilities, with recovery and fixation ratios reaching 88% and 98%, respectively. It was verified that PUFs can resist 40 Gy radiotherapy without changing their mechanical properties and biocompatibility. This study introduces an innovative approach to produce customizable foam for the reconstruction of implant prostheses for the breast.
- 6 November 2024
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 113 (1)
Shape Memory Polyurethane Foams With Tunable Mechanical Properties and Radiation Tolerance for Breast Repair and Reconstruction
This study developed a shape memory polyurethane foam (SM‐PUF) with tunable mechanical properties and exceptional radiation tolerance for potentially implanting tissue defects after mastectomy. The PUFs were synthesized via an in situ foaming strategy using water as a foaming agent, incorporating 4,4′‐diphenylmethane diisocyanate (MDI) as the rigid segment and both polyoxytetramethylene glycol and polycaprolactone as the soft segment. The resultant PUFs possess an open‐cell structure with a pore size of 30 ~ 800 μm, which achieves a compressive stress of 0.04 MPa under 70% compression strain and a tensile elongation of 667.9%. PUFs exhibit body temperature (37°C)‐responsive softening and shape memory abilities, with recovery and fixation ratios reaching 88% and 98%, respectively. It was verified that PUFs can resist 40 Gy radiotherapy without changing their mechanical properties and biocompatibility. This study introduces an innovative approach to produce customizable foam for the reconstruction of implant prostheses for the breast.
- Open Access
- 18 October 2024
- Published by Wiley in Microbial Biotechnology
- Vol. 17 (10)
Lactobacillus rhamnosus GG and Bifidobacterium animalis subsp. lactis BB ‐12 promote infected wound healing via regulation of the wound microenvironment
Infected wounds can result in complex clinical complications and delayed healing, presenting a significant global public health challenge. This study explored the effects of topical application of two probiotics, Lactobacillus rhamnosus GG (LGG) and Bifidobacterium animalis subsp. lactis BB‐12, on the microenvironment of infected wounds and their impact on wound healing. LGG and BB‐12 were applied separately and topically on the Staphylococcus aureus (S. aureus) ‐infected skin wounds of the rat model on a daily basis. Both probiotics significantly accelerated wound healing, demonstrated by enhanced granulation tissue formation and increased collagen deposition, with BB‐12 showing superior efficacy. LGG and BB‐12 both effectively inhibited neutrophil infiltration and decreased the expression of pro‐inflammatory cytokines tumor necrosis factor‐α (TNF‐α) and interleukin‐6 (IL‐6). Notably, BB‐12 markedly reduced IL‐6 levels, while LGG significantly lowered TNF‐α, transforming growth factor‐β (TGF‐β) and vascular endothelial growth factor (VEGF). Additionally, both probiotics promoted macrophage polarization towards the anti‐inflammatory M2 phenotype. Microbiota analysis revealed that LGG and BB‐12 significantly decreased the abundance of pathogenic bacteria (e.g. Staphylococcus and Proteus ) and increased the proportion of beneficial bacteria (e.g. Corynebacterium ). Particularly, BB‐12 was more effective in reducing Staphylococcus abundance, whereas LGG excelled in promoting Corynebacterium growth. These findings suggest the ability of LGG and BB‐12 to modulate the wound microenvironment, enhance wound healing and provide valuable insights for the management of infected wounds.
- 18 October 2024
- Published by Wiley in Microbial Biotechnology
- Vol. 17 (10)
Open AccessLactobacillus rhamnosus GG and Bifidobacterium animalis subsp. lactis BB ‐12 promote infected wound healing via regulation of the wound microenvironment
Infected wounds can result in complex clinical complications and delayed healing, presenting a significant global public health challenge. This study explored the effects of topical application of two probiotics, Lactobacillus rhamnosus GG (LGG) and Bifidobacterium animalis subsp. lactis BB‐12, on the microenvironment of infected wounds and their impact on wound healing. LGG and BB‐12 were applied separately and topically on the Staphylococcus aureus (S. aureus) ‐infected skin wounds of the rat model on a daily basis. Both probiotics significantly accelerated wound healing, demonstrated by enhanced granulation tissue formation and increased collagen deposition, with BB‐12 showing superior efficacy. LGG and BB‐12 both effectively inhibited neutrophil infiltration and decreased the expression of pro‐inflammatory cytokines tumor necrosis factor‐α (TNF‐α) and interleukin‐6 (IL‐6). Notably, BB‐12 markedly reduced IL‐6 levels, while LGG significantly lowered TNF‐α, transforming growth factor‐β (TGF‐β) and vascular endothelial growth factor (VEGF). Additionally, both probiotics promoted macrophage polarization towards the anti‐inflammatory M2 phenotype. Microbiota analysis revealed that LGG and BB‐12 significantly decreased the abundance of pathogenic bacteria (e.g. Staphylococcus and Proteus ) and increased the proportion of beneficial bacteria (e.g. Corynebacterium ). Particularly, BB‐12 was more effective in reducing Staphylococcus abundance, whereas LGG excelled in promoting Corynebacterium growth. These findings suggest the ability of LGG and BB‐12 to modulate the wound microenvironment, enhance wound healing and provide valuable insights for the management of infected wounds.