Tingting Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tingting Hu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Yanting Han
Medicine and Engineering Interdisciplinary Research Laboratory of Nursing & Materials West China Hospital/West China School of Nursing Sichuan University Chengdu China
3 shared publications - Ka Li
Medicine and Engineering Interdisciplinary Research Laboratory of Nursing & Materials, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, China
2 shared publications Can Liu
Department of Advanced Energy Materials College of Materials Science and Engineering Sichuan University Chengdu P. R. China
1 shared publication- Cheng Shen
Department of Thoracic Surgery, West China Hospital, Sichuan University, Chengdu, China
1 shared publication - Fanglin Wu
State Key Laboratory of Advanced Technology for Materials Synthesis and Processing Wuhan University of Technology Wuhan P. R. China
1 shared publication Huan Yang
Department of Advanced Energy Materials College of Materials Science and Engineering Sichuan University Chengdu P. R. China
1 shared publication
Latest Publications
- 5 August 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (56)
An On‐Skin Visually Monitorable Gel‐Matrix Zinc–Ion Battery for Electrically Stimulated Wound Healing
Aqueous zinc‐ion batteries (ZIBs) feature intrinsic safety, low cost, and environmental compatibility, making them attractive for untapped cutting‐edge applications, such as the biomedicine area. Particularly, wearable medical power sources require stable electrical output, mechanical flexibility, and high biocompatibility. Herein, a stable and flexible gel‐matrix aqueous ZIB was designed as an on‐skin power source for electrically stimulated wound healing. The elaborately designed graded porous framework hydrogel electrolyte (GPF‐HGE) obtains high ionic conductivity (17.19 mS cm −1 ) and improved mechanical deformation tolerance (46 kPa and 205 J m −2 ) due to the porous framework formed in the solvent exchange process. Its transparency property, combined with an annular ring‐shaped electrode that generates an electric field aligned with the endogenous wound electric field, enables direct application to wound sites and real‐time visual monitoring. The assembled Zn|GPF‐HGE|I 2 @AC full cells show superior long‐term cycling stability accompanied by slight capacity fading, ensuring a steady energy supply for electrical stimulation (ES). Benefiting from its robust electrochemical stability and excellent biocompatibility, the obtained ES device can provide reliable electrical signals and promote wound healing through synergistic antibacterial and anti‐inflammatory effects. This work highlights the potential of aqueous ZIBs as advanced biomedical power sources beyond conventional energy storage applications.
- 5 August 2026
- Published by Wiley in Advanced Materials
- Vol. 38 (56)
An On‐Skin Visually Monitorable Gel‐Matrix Zinc–Ion Battery for Electrically Stimulated Wound Healing
Aqueous zinc‐ion batteries (ZIBs) feature intrinsic safety, low cost, and environmental compatibility, making them attractive for untapped cutting‐edge applications, such as the biomedicine area. Particularly, wearable medical power sources require stable electrical output, mechanical flexibility, and high biocompatibility. Herein, a stable and flexible gel‐matrix aqueous ZIB was designed as an on‐skin power source for electrically stimulated wound healing. The elaborately designed graded porous framework hydrogel electrolyte (GPF‐HGE) obtains high ionic conductivity (17.19 mS cm −1 ) and improved mechanical deformation tolerance (46 kPa and 205 J m −2 ) due to the porous framework formed in the solvent exchange process. Its transparency property, combined with an annular ring‐shaped electrode that generates an electric field aligned with the endogenous wound electric field, enables direct application to wound sites and real‐time visual monitoring. The assembled Zn|GPF‐HGE|I 2 @AC full cells show superior long‐term cycling stability accompanied by slight capacity fading, ensuring a steady energy supply for electrical stimulation (ES). Benefiting from its robust electrochemical stability and excellent biocompatibility, the obtained ES device can provide reliable electrical signals and promote wound healing through synergistic antibacterial and anti‐inflammatory effects. This work highlights the potential of aqueous ZIBs as advanced biomedical power sources beyond conventional energy storage applications.
- Open Access
- 9 April 2026
- Published by AIP Publishing in APL Bioengineering
- Vol. 10 (2)
Research progress in flap temperature monitoring technologies and applications after transplantation
As a primary method for tissue repair and functional reconstruction, flap transplantation has achieved a clinical success rate of over 90%. However, the postoperative incidence of vascular crisis remains as high as 10%–30%, making it a leading cause of reoperation and disability. Flap temperature is a key indicator closely correlated with microcirculatory status, making its monitoring essential for the early detection of complications. This paper provides a systematic review of the physiological mechanisms underlying postoperative flap temperature, the characteristic temperature changes associated with venous and arterial crises, and the latest advancements in monitoring technologies. It comprehensively analyzes the principles, advantages, and limitations of various methods, including manual palpation, contact thermometry, infrared thermography, fiber optic sensing, and microwave thermometry. Furthermore, the review explores the application of intelligent technologies such as wearable sensors, artificial intelligence-driven predictive systems, implantable flexible devices, and multimodal fusion monitoring. Current challenges, including poor real-time performance, low precision, and a lack of standardization, are highlighted. Future development is directed toward precision, intelligence, and integration, with an emphasis on multidisciplinary collaboration to create more accurate, convenient, and intelligent monitoring systems. These advancements aim to achieve precise early warning and timely intervention, ultimately improving flap survival rates and patient outcomes.
- 9 April 2026
- Published by AIP Publishing in APL Bioengineering
- Vol. 10 (2)
Open AccessResearch progress in flap temperature monitoring technologies and applications after transplantation
As a primary method for tissue repair and functional reconstruction, flap transplantation has achieved a clinical success rate of over 90%. However, the postoperative incidence of vascular crisis remains as high as 10%–30%, making it a leading cause of reoperation and disability. Flap temperature is a key indicator closely correlated with microcirculatory status, making its monitoring essential for the early detection of complications. This paper provides a systematic review of the physiological mechanisms underlying postoperative flap temperature, the characteristic temperature changes associated with venous and arterial crises, and the latest advancements in monitoring technologies. It comprehensively analyzes the principles, advantages, and limitations of various methods, including manual palpation, contact thermometry, infrared thermography, fiber optic sensing, and microwave thermometry. Furthermore, the review explores the application of intelligent technologies such as wearable sensors, artificial intelligence-driven predictive systems, implantable flexible devices, and multimodal fusion monitoring. Current challenges, including poor real-time performance, low precision, and a lack of standardization, are highlighted. Future development is directed toward precision, intelligence, and integration, with an emphasis on multidisciplinary collaboration to create more accurate, convenient, and intelligent monitoring systems. These advancements aim to achieve precise early warning and timely intervention, ultimately improving flap survival rates and patient outcomes.
- Open Access
- 25 February 2026
- Published by AIP Publishing in APL Bioengineering
- Vol. 10 (1)
New concept in wound infection management: From bacterial eradication to microbiome modulation
Wound infection represents a significant challenge in clinical practice. Traditional wound management, targeting sterility and relying on strategies of broad-spectrum bactericidal activity and antibiotic dependence, achieves partial infection control but induces severe complications, including exacerbated bacterial resistance and skin microbiota dysbiosis. With the continuous advancement of microbiome research, a novel consensus has emerged: the key to wound healing lies not in the complete eradication of all microorganisms but in maintaining the dynamic balance of the microbial ecosystem. This review aims to elaborate on the paradigm shift from “bactericidal eradication” to “microbial modulation” in wound care, analyze the inherent limitations of conventional antibacterial strategies, and systematically summarize the critical roles of skin commensal microbiota in promoting wound healing through core mechanisms such as competitive inhibition, metabolic regulation, and immune modulation. Furthermore, it proposes that the core strategy of future wound care should focus on precision microbial modulation and discusses the application prospects of cutting-edge technologies, including probiotics, postbiotics, and individualized precision interventions. The innovative significance of this paradigm in wound dressing design is envisaged, emphasizing the development of novel materials integrating microbiota-specific regulatory capabilities and smart responsive functions. This work provides theoretical support for the precision prevention and control of wound infections, the improvement of healing quality, and technological innovation in the field of wound care.
- 25 February 2026
- Published by AIP Publishing in APL Bioengineering
- Vol. 10 (1)
Open AccessNew concept in wound infection management: From bacterial eradication to microbiome modulation
Wound infection represents a significant challenge in clinical practice. Traditional wound management, targeting sterility and relying on strategies of broad-spectrum bactericidal activity and antibiotic dependence, achieves partial infection control but induces severe complications, including exacerbated bacterial resistance and skin microbiota dysbiosis. With the continuous advancement of microbiome research, a novel consensus has emerged: the key to wound healing lies not in the complete eradication of all microorganisms but in maintaining the dynamic balance of the microbial ecosystem. This review aims to elaborate on the paradigm shift from “bactericidal eradication” to “microbial modulation” in wound care, analyze the inherent limitations of conventional antibacterial strategies, and systematically summarize the critical roles of skin commensal microbiota in promoting wound healing through core mechanisms such as competitive inhibition, metabolic regulation, and immune modulation. Furthermore, it proposes that the core strategy of future wound care should focus on precision microbial modulation and discusses the application prospects of cutting-edge technologies, including probiotics, postbiotics, and individualized precision interventions. The innovative significance of this paradigm in wound dressing design is envisaged, emphasizing the development of novel materials integrating microbiota-specific regulatory capabilities and smart responsive functions. This work provides theoretical support for the precision prevention and control of wound infections, the improvement of healing quality, and technological innovation in the field of wound care.