IKIvan S. Kucherenko

Ivan S. Kucherenko

*This is an algorithmically generated author record based on publicly available information.

Ivan S. Kucherenko has a total of 95 co-authors. Here are the top co-authors by number of shared publications:

  • Sergei V. Dzyadevych

    Institute of Molecular Biology and Genetics, The National Academy of Sciences of Ukraine, 150 Zabolotnoho Str., 03143 Kyiv, Ukraine

    25 shared publications
  • Alexey P. Soldatkin

    Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine

    21 shared publications
  • Burcu Akata

    Middle East Technical University

    11 shared publications
  • O. O. Soldatkin

    Department of Biomolecular Electronics Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine 150, Zabolotny Str. Kyiv 03680 Ukraine

    9 shared publications
  • O.O. Soldatkin

    Institute of Molecular Biology and Genetics, NAS of Ukraine, 150 Zabolotnogo str., 03143 Kyiv, Ukraine; Taras Shevchenko Kyiv National University, 64 Volodymyrska str., 01601 Kyiv, Ukraine

    8 shared publications
  • Oleksandr O. Soldatkin

    Інститут молекулярної біології і генетики НАН України; Національний технічний університет України «Київський політехнічний інститут імені Ігоря Сікорського», Україна

    8 shared publications

Latest Publications

  • Développement de biocapteurs pour la détermination de substances biologiquement actives

    by Ivan Kucherenko

    Les biocapteurs sont des moyens d’analyse en plein essor à la fois rapides, sélectifs et peu coûteux applicables à des domaines extrêmement variés (environnement, santé, agroalimentaire,…). Dans ce type d’outil, un élément sensible de nature biologique (anticorps, enzyme, microorganisme, ADN…) doté d’un pouvoir de reconnaissance pour un analyte ou un groupe d’analytes est associé à un transducteur pouvant être de type électrochimique, optique ou thermique.Dans ce travail, nous nous sommes intéressés au développement de trois biocapteurs pour la détection de substances biologiquement actives. Le premier permet la détermination simultanée de l’adénosine triphosphate (ATP) et du glucose par ampérométrie, le deuxième celle de la créatine kinase, et le troisième est un biocapteur conductimétique pour la quantification de l’ATP. Dans les deux premiers biocapteurs, deux enzymes (l’hexokinase et la glucose oxydase) sont immobilisées à la surface de microélectrodes constituées d’un disque de platine. Le troisième biocapteur est basé sur l’immobilisation de l’hexokinase sur des microélectrodes interdigitées en or. L’immobilisation est réalisée dans tous les cas par co-réticulation des enzymes en présence d’albumine de sérum bovin à l’aide de glutaraldehyde. Les caractéristiques analytiques des biocapteurs ont été déterminées et différentes procédures ont été développées pour l’analyse d’échantillons réels. Les biocapteurs ont pu être appliqués avec succès à la quantification de l’ATP, du glucose et de la créatine kinase dans des préparations pharmaceutiques et du sérum sanguin

  • Open Access

    DEVELOPMENT OF AN AMPEROMETRIC GLUTAMATE-SENSITIVE BIOSENSOR BASED ON GLUTAMATE OXIDASE ADSORBED ON SILICALITE

    by O. V. Soldatkina, D. O. Mruga, D. Yu. Kucherenko, I. S. Kucherenko, O. O. Soldatkin, B. Akata Kurç, S. V. Dzyadevych

    In the current work, a new design of an amperometric biosensor for highly sensitive and selective detection of glutamate was developed using an atypical method of immobilizing glutamate oxidase (GlOX) by adsorption onto silicalite nanoparticles. The procedure for manufacturing the biosensor was optimized, namely, the main parameters of the modification of amperometric platinum transducers with a layer of silicalite nanoparticles were determined, and the optimal conditions for GlOX adsorption on this layer were also selected. Biosensors based on GlOX adsorbed on silicalite demonstrated high sensitivity to low concentrations of glutamate. The linear detection range was from 2.5 μM to 450 μM, and the detection limit of glutamate was 1 μM. It was also shown in the work that the proposed biosensors are characterized by high reproducibility of responses during several hours of continuous operation (RSD up to 7%) and good operational stability for several days. After carrying out the entire complex of works on the development and optimization of a new glutamate-sensitive biosensor, it was found that sensors of this design with the declared analytical characteristics can be used to determine low concentrations of glutamate in real biological fluids.

  • Application of butyrylcholinesterase‐based biosensor for simultaneous determination of different toxicants using inhibition and reactivation steps

    by O. O. Soldatkin, V. M. Pyeshkova, I. S. Kucherenko, T. P. Velychko, V. A. Bakhmat, V. M. Arkhypova, A. P. Soldatkin., S. V. Dzyadevych

    Fast and simple detection of toxic compounds in aqueous solutions is important for agriculture and pollution monitoring. Enzyme‐based electrochemical biosensors are a promising platform for this task, but they usually lack the ability to distinguish between toxicants if more than one toxicant is present in the sample. Herein, we propose a new method of detection of various toxic compounds in complex multi‐component water samples using an electrochemical biosensor and additional stages of enzyme reactivation. The biosensor is based on butyrylcholinesterase immobilized on the surface of conductometric transducers using glutaraldehyde cross‐linking. It was shown that the biosensor is sensitive to organophosphorus pesticides, heavy metals ions, glycoalkaloids, but has a limited sensitivity to mycotoxins and surfactants. We propose a procedure for the analysis of complex samples with several reactivation stages to be able to determine which category of toxicants is present. Glycoalkaloids are reversible inhibitors and biosensor's activity is restored by washing in working buffer; heavy metal ions and pesticides are irreversible inhibitors and biosensor's activity is restored by incubation in EDTA and PAM‐2 solutions, correspondingly. This biosensor can be used for the detection of separate toxicants or for analysis of their mixtures in aqueous samples. It can be also used for the evaluation of total toxicity of the samples and applied for water quality monitoring.


  • A novel adenosine triphosphate (ATP) biosensor based on electrospun polymer nanofibers with entrapped hexokinase and glucose oxidase

    by Ivan S. Kucherenko, Carole Farre, Gaetan Raimondi, Carole Chaix, Nicole Jaffrezic-Renault, Jean-François Chateaux, Maksim Sobolevskyi, Oleksandr O. Soldatkin, Sergei V. Dzyadevych, Alexei P. Soldatkin, et al.


  • Open Access

    Application of zeolites and zeolitic imidazolate frameworks in the biosensor development

    by I.S. Kucherenko, O.O. Soldatkin, S.V. Dzyadevych, A.P. Soldatkin


  • Open Access

    DEVELOPMENT OF ARGININE DEIMINASE BASED CONDUCTOMETRIC BIOSENSOR FOR ARGININE DETERMINATION

    by O. O. Soldatkin, I. S. Kucherenko, O. Ya. Sayapina, D. Yu. Kucherenko, S. V. Marchenko, A. P. Soldatkin, S. V. Dzyadevych

    Вперше розроблено кондуктометричний ферментний біосенсор для визначення концентрацій аргініну. При виготовлені біоселективної мембрани біосенсора використовували аргініндеіміназу, яка була іммобілізована ковалентною зшивкою глутаровим альдегідом з бичачим сироватковим альбуміном на поверхні золотого планарного перетворювача. В роботі було перевірено вплив параметрів розчину (іонна сила, буферна ємність) на функціонування біосенсора для визначення аргініну. Показано, що запропонований моноферментний біосенсор характеризувався гарною селективністю відносно можливих інтерферуючих речовин. Біосенсор характеризувався високою чутливістю до аргініну (мінімальна границя визначення – 5 мкМ). Лінійний діапазон біосенсорного визначення аналіту був від 10 до 800 мкМ. Чутливість біосенсора до аргініну - 72 мкСм/мМ. Показано, що розроблений біосенсор є перспективним для застосування при аналізі концентрацій аргініну в реальних зразках.

  • Development of Enzyme Conductometric Biosensor for Dopamine Determination in Aqueous Samples

    by Oleksandr Soldatkin, I. S. Kucherenko, D. V. Siediuko, D. Yu. Kucherenko, Sergei Dzyadevych, Alexei Soldatkin

    Dopamine is a biologically active chemical that performs a number of vital functions as a hormone and neurotransmitter. Therefore, the determination of dopamine concentration in the human body is important for biomedical research. The content of dopamine in the blood varies depending on the age of a healthy person and can serve as a prognostic marker of many diseases. The aim of this work was to develop a new enzyme conductometric biosensor for the determination of dopamine in aqueous samples and to study the biosensor's analytical characteristics. The conductometric method of analysis with differential measurement mode was used in the work. Two pairs of gold interdigitated electrodes deposited on a sitall substrate were used as a conductometric transducer. The biorecognition element of the biosensor was based on laccase immobilized by glutaraldehyde cross‐linking. The optimal conditions of laccase immobilization were selected. The influence of solution parameters (ionic strength, pH, buffer capacity) on the biosensor work was investigated. The biosensors demonstrated high sensitivity to dopamine (minimum limit of detection −7.8 μM) with the linear range up to 1 mM. The biosensor was highly selective and reusable. The proposed biosensor was tested regarding the possibility of its long‐term storage under different conditions. The developed conductometric biosensor was proven to be suitable for measuring dopamine concentration in biological and pharmaceutical samples.


  • Open Access

    Advances in nanomaterial application in enzyme-based electrochemical biosensors: a review

    by I. S. Kucherenko, O. O. Soldatkin, D. Yu. Kucherenko, O. V. Soldatkina, S. V. Dzyadevych

    Application of nanomaterials greatly improves performance of electrochemical enzyme-based biosensors.