Joe Preston Foley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joe Preston Foley has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Kimberly A. Kahle
Department of Chemistry, Drexel University, Philadelphia, PA 19104, USA
6 shared publicationsMelissa D. Mertzman
ALZA Corporation, Menlo Park, California, USA
6 shared publicationsRobert J. Pascoe
4 shared publicationsDonna M. Blackney
Department of Chemistry, Drexel University, 3141 Chestnut Street, Philadelphia, PA 19104, United States
3 shared publicationsEric S. Ahuja
Merck & Co., Inc., West Point, PA, USA
3 shared publications- Karyn Camilo
Department of Chemistry, Drexel University, Philadelphia, USA
3 shared publications
Latest Publications
- 10 March 2026
- Published by Drexel University Libraries
Sequential elution liquid chromatography using ion exchange stationary phases
Sequential Elution Liquid Chromatography (SE-LC) using ion exchange phases is a powerful technique for the separation of complex samples. SE-LC separates analytes by class with multiple elution modes, offering higher peak capacity and reduced separation disorder compared to conventional HPLC, while utilizing standard HPLC instrumentation. An SE-LC method was developed for the separation of permanently charged ions, weak acids, and neutral compounds by employing anion exchange and reversed-phase columns in tandem. Optimization of mobile phase composition, pH, and gradients was critical for effective class-based separation. The finalized method incorporated isocratic elution at low pH to elute the weak acids, followed by an acetonitrile gradient to elute the neutral compounds, and last a sodium methanesulfonate gradient to elute the anionic compounds using a superficially porous C18 column coupled with a strong anion exchange column. High repeatability (RSD < 0.25% for retention time and < 1.5% for peak area) was demonstrated. The above method was validated for quantitative analysis. The validation confirmed its specificity, linearity, accuracy, precision (repeatability), and the flow rate, starting mobile phase organic content, column temperature, mobile phase composition, and gradient start time. The method was demonstrated to be robust, specific, linear, accurate, and precise (repeatable) over the range of 6%-120% of the target analyte range. A second quantitative SE-LC method was developed to separate six pharmaceutical drug product excipients by their classes--amino acids (methionine, arginine, and histidine) and antimicrobial preservatives (sodium benzoate, methylparaben, and propylparaben). This method employed a tandem column setup with a cation exchange column and reversed-phase column (C18) in tandem and utilized a pH gradient to elute the amino acids followed by an acetonitrile gradient to elute the antimicrobial preservatives within 18 minutes. The method was also validated and demonstrated to be specific, linear, accurate, and precise (repeatable) over the range of 50%-150% of the target analyte concentrations. Method robustness was also assessed using a full factorial design of experiments for which the factors investigated were mobile phase concentration, acetonitrile gradient start time and starting percentage of acetonitrile. Based on the factorial results for the experiments, with respect to the relative retention time of the critical pair (sodium benzoate: arginine), the mobile phase concentration and acetonitrile were significant factors that affected the separation. This method could be applied in pharmaceutical laboratories to measure amounts of methionine, arginine, histidine, sodium benzoate, methylparaben, and propylparaben in drug products.
- 10 March 2026
- Published by Drexel University Libraries
Sequential elution liquid chromatography using ion exchange stationary phases
Sequential Elution Liquid Chromatography (SE-LC) using ion exchange phases is a powerful technique for the separation of complex samples. SE-LC separates analytes by class with multiple elution modes, offering higher peak capacity and reduced separation disorder compared to conventional HPLC, while utilizing standard HPLC instrumentation. An SE-LC method was developed for the separation of permanently charged ions, weak acids, and neutral compounds by employing anion exchange and reversed-phase columns in tandem. Optimization of mobile phase composition, pH, and gradients was critical for effective class-based separation. The finalized method incorporated isocratic elution at low pH to elute the weak acids, followed by an acetonitrile gradient to elute the neutral compounds, and last a sodium methanesulfonate gradient to elute the anionic compounds using a superficially porous C18 column coupled with a strong anion exchange column. High repeatability (RSD < 0.25% for retention time and < 1.5% for peak area) was demonstrated. The above method was validated for quantitative analysis. The validation confirmed its specificity, linearity, accuracy, precision (repeatability), and the flow rate, starting mobile phase organic content, column temperature, mobile phase composition, and gradient start time. The method was demonstrated to be robust, specific, linear, accurate, and precise (repeatable) over the range of 6%-120% of the target analyte range. A second quantitative SE-LC method was developed to separate six pharmaceutical drug product excipients by their classes--amino acids (methionine, arginine, and histidine) and antimicrobial preservatives (sodium benzoate, methylparaben, and propylparaben). This method employed a tandem column setup with a cation exchange column and reversed-phase column (C18) in tandem and utilized a pH gradient to elute the amino acids followed by an acetonitrile gradient to elute the antimicrobial preservatives within 18 minutes. The method was also validated and demonstrated to be specific, linear, accurate, and precise (repeatable) over the range of 50%-150% of the target analyte concentrations. Method robustness was also assessed using a full factorial design of experiments for which the factors investigated were mobile phase concentration, acetonitrile gradient start time and starting percentage of acetonitrile. Based on the factorial results for the experiments, with respect to the relative retention time of the critical pair (sodium benzoate: arginine), the mobile phase concentration and acetonitrile were significant factors that affected the separation. This method could be applied in pharmaceutical laboratories to measure amounts of methionine, arginine, histidine, sodium benzoate, methylparaben, and propylparaben in drug products.
- 20 March 2025
- Published by Wiley in Journal of Separation Science
- Vol. 48 (3) , e70124
Validation of a High‐Performance Liquid Chromatography Separation of Weak Acids, Neutral Compounds, and Permanent Ions Using Sequential Elution with Tandem‐Column Liquid Chromatography
Sequential elution‐liquid chromatography (SE‐LC) employs conventional high‐performance LC instrumentation to separate compounds by class and within each class using two or more sequential elution modes. The aim of this work was to validate a novel SE‐LC method used to separate weak acids, permanently charged ions (anions), and neutral compounds by applying first a low pH isocratic elution to elute the weak acids, then an acetonitrile gradient to elute the neutral compounds, and lastly a sodium methanesulfonate gradient to elute the anionic compounds using a tandem‐column arrangement comprised of a C18 column and a strong anion exchange column. The effects of flow rate, starting mobile phase organic content, column temperature, mobile phase composition, and gradient start time were investigated using a 25‐1 fractional factorial design with center points for robustness. The method was demonstrated to be robust, specific, linear, accurate, and precise (repeatable) over the range of 6%–120% of the target analyte concentrations.
- 20 March 2025
- Published by Wiley in Journal of Separation Science
- Vol. 48 (3) , e70124
Validation of a High‐Performance Liquid Chromatography Separation of Weak Acids, Neutral Compounds, and Permanent Ions Using Sequential Elution with Tandem‐Column Liquid Chromatography
Sequential elution‐liquid chromatography (SE‐LC) employs conventional high‐performance LC instrumentation to separate compounds by class and within each class using two or more sequential elution modes. The aim of this work was to validate a novel SE‐LC method used to separate weak acids, permanently charged ions (anions), and neutral compounds by applying first a low pH isocratic elution to elute the weak acids, then an acetonitrile gradient to elute the neutral compounds, and lastly a sodium methanesulfonate gradient to elute the anionic compounds using a tandem‐column arrangement comprised of a C18 column and a strong anion exchange column. The effects of flow rate, starting mobile phase organic content, column temperature, mobile phase composition, and gradient start time were investigated using a 25‐1 fractional factorial design with center points for robustness. The method was demonstrated to be robust, specific, linear, accurate, and precise (repeatable) over the range of 6%–120% of the target analyte concentrations.
- Open Access
- 20 July 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1731, 465178
Separation of weak acids, neutral compounds, and permanent anions using sequential elution liquid chromatography with tandem columns
- 20 July 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1731, 465178
Open AccessSeparation of weak acids, neutral compounds, and permanent anions using sequential elution liquid chromatography with tandem columns
- Open Access
- 29 June 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1730, 465131
A simulation-guided approach to the selection of RPLC columns for platform small molecule separations
- 29 June 2024
- Published by Elsevier in Journal of Chromatography A
- Vol. 1730, 465131
Open AccessA simulation-guided approach to the selection of RPLC columns for platform small molecule separations
- 27 November 2023
- Published by Drexel University Libraries
The Advantages and Applications of Tandem-Column Liquid Chromatography in Pharmaceutical Compound Separations
This research established a simulation based on the hydrophobic subtraction model (HSM) of retention and selectivity and basic liquid chromatography (LC) principles for tandem-column LC. The simulation was used to compare the separation potential of different modes of LC and to guide a method development experiment of a set of pharmaceutical compounds. LC is the most commonly used analytical technique for the analysis of pharmaceutical products. The modern pharmaceutical quality control system requires a high standard of analysis, usually a complete separation of all related compounds in a given pharmaceutical sample. This is often a challenge for conventional single-column LC (SC-LC). However, techniques with higher probability of successful separation, such as two-dimensional LC, require a much higher investment in instrumentation. Tandem-column LC (TC-LC) can use the same instrumentation as conventional SC-LC, but it can provide a higher separation potential than SC-LC (still lower than 2D-LC). A series of simulations were conducted to compare the separation potential of SC-LC and TC-LC. The simulation included 16 HSM reference compounds. More than ten-thousand virtual samples were generated for the simulation. TC-LC showed a significant advantage in the comparisons. The simulation also showed that a TC-LC column inventory can be much smaller than one for SC-LC, but still have a higher separation potential. The simulations of both fixed combinations of tandem-column pair and exchangeable combination of tandem-column pair proved the idea. An optimal order of columns to employ in platform methods or screening was also established based on simulation results. TC-LC uses two columns in-tandem to get a different selectivity than the two columns provide individually. It's therefore challenging to select the columns based on a chromatographer's experience and thus assistance from simulation is necessary or at least very helpful. A new workflow for TC-LC method development was established in the experiments. In this study, HSM solute parameters were experimentally determined for a small molecule pharmaceutical (Linrodostat) and ten of its related impurities using multiple linear regression of their retentions on 16 selected RPLC columns against in-house determined HSM column parameters. R_C values were calculated based on HSM database column parameters for a pool of about 200 available stationary phases in both single-column mode (2.1 mm i.d. x 100 mm) or tandem-column paired mode (two 2.1 mm i.d. x 50 mm) formats. Four column configurations (two single and two tandem) were predicted to achieve successful separations under isocratic HSM separation conditions, with a fifth tandem pair predicted to have a single co-elution. Of these five potential candidates, one tandem pair yielded compete baseline resolution of the 11-component mixture in an experimental separation. In this specific case, the tandem column pairs outperformed single columns, with better predicted and experimental R_C values for the Linrodostat mixture under the HSM separation conditions. The results reported in this study demonstrated the enormous selectivity potential of TC-LC in pharmaceutical compound separations and are consistent with our previous study that examined the potential of tandem column approaches using purely computational means, though there is room for substantial improvement in the prediction accuracy. The proposed workflow can be used to prioritize a small number of column combinations by computational means before any experiments are conducted. This is highly attractive from the point of view of time and resource savings considering over 200,000 different tandem column pairings are possible using columns for which there is data in the HSM database. This research showed TC-LC is potentially a good approach in analysis of small molecule compounds in pharmaceutical or other related applications. TC-LC can save hardware investment for labs and human resources in method development. It could also be an attractive LC technique in related fields.
- 27 November 2023
- Published by Drexel University Libraries
The Advantages and Applications of Tandem-Column Liquid Chromatography in Pharmaceutical Compound Separations
This research established a simulation based on the hydrophobic subtraction model (HSM) of retention and selectivity and basic liquid chromatography (LC) principles for tandem-column LC. The simulation was used to compare the separation potential of different modes of LC and to guide a method development experiment of a set of pharmaceutical compounds. LC is the most commonly used analytical technique for the analysis of pharmaceutical products. The modern pharmaceutical quality control system requires a high standard of analysis, usually a complete separation of all related compounds in a given pharmaceutical sample. This is often a challenge for conventional single-column LC (SC-LC). However, techniques with higher probability of successful separation, such as two-dimensional LC, require a much higher investment in instrumentation. Tandem-column LC (TC-LC) can use the same instrumentation as conventional SC-LC, but it can provide a higher separation potential than SC-LC (still lower than 2D-LC). A series of simulations were conducted to compare the separation potential of SC-LC and TC-LC. The simulation included 16 HSM reference compounds. More than ten-thousand virtual samples were generated for the simulation. TC-LC showed a significant advantage in the comparisons. The simulation also showed that a TC-LC column inventory can be much smaller than one for SC-LC, but still have a higher separation potential. The simulations of both fixed combinations of tandem-column pair and exchangeable combination of tandem-column pair proved the idea. An optimal order of columns to employ in platform methods or screening was also established based on simulation results. TC-LC uses two columns in-tandem to get a different selectivity than the two columns provide individually. It's therefore challenging to select the columns based on a chromatographer's experience and thus assistance from simulation is necessary or at least very helpful. A new workflow for TC-LC method development was established in the experiments. In this study, HSM solute parameters were experimentally determined for a small molecule pharmaceutical (Linrodostat) and ten of its related impurities using multiple linear regression of their retentions on 16 selected RPLC columns against in-house determined HSM column parameters. R_C values were calculated based on HSM database column parameters for a pool of about 200 available stationary phases in both single-column mode (2.1 mm i.d. x 100 mm) or tandem-column paired mode (two 2.1 mm i.d. x 50 mm) formats. Four column configurations (two single and two tandem) were predicted to achieve successful separations under isocratic HSM separation conditions, with a fifth tandem pair predicted to have a single co-elution. Of these five potential candidates, one tandem pair yielded compete baseline resolution of the 11-component mixture in an experimental separation. In this specific case, the tandem column pairs outperformed single columns, with better predicted and experimental R_C values for the Linrodostat mixture under the HSM separation conditions. The results reported in this study demonstrated the enormous selectivity potential of TC-LC in pharmaceutical compound separations and are consistent with our previous study that examined the potential of tandem column approaches using purely computational means, though there is room for substantial improvement in the prediction accuracy. The proposed workflow can be used to prioritize a small number of column combinations by computational means before any experiments are conducted. This is highly attractive from the point of view of time and resource savings considering over 200,000 different tandem column pairings are possible using columns for which there is data in the HSM database. This research showed TC-LC is potentially a good approach in analysis of small molecule compounds in pharmaceutical or other related applications. TC-LC can save hardware investment for labs and human resources in method development. It could also be an attractive LC technique in related fields.
- 27 October 2023
- Published by Springer Nature in Chromatographia
- Vol. 86 (11-12) , 743-750
Tandem-Column High Performance Liquid Chromatography Separation of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs)
- 27 October 2023
- Published by Springer Nature in Chromatographia
- Vol. 86 (11-12) , 743-750
Tandem-Column High Performance Liquid Chromatography Separation of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs)
- 11 July 2022
- Published by Drexel University Libraries
Chiral and Achiral HPLC Separation of Chiral Pharmaceutical Compounds
This project is focused on developing a liquid chromatographic method that separates four Non-Steroidal Anti-Inflammatory Drugs (Ketoprofen, Naproxen, Ibuprofen, and Flurbiprofen) and three of the four pairs of enantiomers in one run. NSAID samples were prepared with 1 mg/mL of Ketoprofen, Naproxen, Ibuprofen, and Flurbiprofen, and 0.5 mg/mL thiourea as a t0 marker in a sample solvent consisting of 1:1 acetonitrile and 0.2% formic acid. The achiral separation of the compounds was investigated using four different columns and two simulations were used to consider the use of two achiral columns connected in tandem to achieve baseline separation of all compounds. The four columns investigated were a 5-cm C18 column, a 5-cm C8 column, a 5-cm perfluoro phenyl column, and a 5-cm biphenyl column. The two simulations were performed using the data from the 5-cm perfluoro phenyl column connected to the 5-cm biphenyl column and the 5-cm perfluoro phenyl column connected to the 5-cm C8 column. The separation of the enantiomers of the NSAIDs was investigated using a chiral column in two different lengths (5-cm, 10-cm) packed with Amylose tris(3,5-dimethylphenylcarbamate) coated on silica gel. The longer column was investigated first. The last method of separation explored utilized the 5-cm version of the aforementioned chiral column connected to each of the achiral columns used during the achiral separations using a zero dead volume column connector. The effect of column order on the retention time and resolution of the NSAIDs was investigated for all the achiral/chiral column combinations. Calculations were performed to predict the retention times and plate numbers for all of the achiral/chiral column combinations and were compared to the values obtained experimentally. The results of the chiral-only and tandem column runs, which employed a reversed-phase mobile phase comprised of aqueous 0.2% formic acid : acetonitrile (67 : 33 v/v), were compared to determine the benefits and drawbacks of each approach, with an emphasis on the resolution and analysis time.
- 11 July 2022
- Published by Drexel University Libraries
Chiral and Achiral HPLC Separation of Chiral Pharmaceutical Compounds
This project is focused on developing a liquid chromatographic method that separates four Non-Steroidal Anti-Inflammatory Drugs (Ketoprofen, Naproxen, Ibuprofen, and Flurbiprofen) and three of the four pairs of enantiomers in one run. NSAID samples were prepared with 1 mg/mL of Ketoprofen, Naproxen, Ibuprofen, and Flurbiprofen, and 0.5 mg/mL thiourea as a t0 marker in a sample solvent consisting of 1:1 acetonitrile and 0.2% formic acid. The achiral separation of the compounds was investigated using four different columns and two simulations were used to consider the use of two achiral columns connected in tandem to achieve baseline separation of all compounds. The four columns investigated were a 5-cm C18 column, a 5-cm C8 column, a 5-cm perfluoro phenyl column, and a 5-cm biphenyl column. The two simulations were performed using the data from the 5-cm perfluoro phenyl column connected to the 5-cm biphenyl column and the 5-cm perfluoro phenyl column connected to the 5-cm C8 column. The separation of the enantiomers of the NSAIDs was investigated using a chiral column in two different lengths (5-cm, 10-cm) packed with Amylose tris(3,5-dimethylphenylcarbamate) coated on silica gel. The longer column was investigated first. The last method of separation explored utilized the 5-cm version of the aforementioned chiral column connected to each of the achiral columns used during the achiral separations using a zero dead volume column connector. The effect of column order on the retention time and resolution of the NSAIDs was investigated for all the achiral/chiral column combinations. Calculations were performed to predict the retention times and plate numbers for all of the achiral/chiral column combinations and were compared to the values obtained experimentally. The results of the chiral-only and tandem column runs, which employed a reversed-phase mobile phase comprised of aqueous 0.2% formic acid : acetonitrile (67 : 33 v/v), were compared to determine the benefits and drawbacks of each approach, with an emphasis on the resolution and analysis time.
- 10 February 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1668, 462890
Are two liquid chromatography columns in tandem better than one?: Answers from the hydrophobic subtraction model
- 10 February 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1668, 462890
Are two liquid chromatography columns in tandem better than one?: Answers from the hydrophobic subtraction model
- 16 July 2021
- Published by Drexel University Libraries
Studies on surfactant purity, chiral composition, and novel surfactant synthesis in chiral electrokinetic chromatography
Electrokinetic chromatography (EKC) has been proven to be a useful tool in order to separate charged, neutral, and neutral and/or charged chiral species with short run times, high efficiencies and excellent resolution. EKC differs from capillary zone electrophoresis (CZE) in that a pseudostationary phase (PSP) is employed in order to separate analytes, providing selectivity that is not achievable in CZE. A variety of additives may be used as the PSP. Some examples are surfactants to form micelles, cyclodextrins (CDs), crown ethers, and polymers. In order to achieve chiral separations, a chiral additive or PSP must be utilized. Chromatographic figures of merit (CFOMs) have been evaluated for a variety of PSP formulations, including micelles, solvent-modified (swollen) micelles and microemulsions. The identity and concentration have also been evaluated and compared to previous formulations of PSPs researched within our group. Purity of the commonly used chiral surfactant in our lab, dodecylcarbonyl valine (DDCV), was evaluated under a variety of methods and its effect on CFOMs determined. Finally, a novel chiral surfactant was synthesized and evaluated under micellar electrokinetic chromatography (MEKC) conditions in order to provide an alternative to the chiral surfactant, DDCV.
- 16 July 2021
- Published by Drexel University Libraries
Studies on surfactant purity, chiral composition, and novel surfactant synthesis in chiral electrokinetic chromatography
Electrokinetic chromatography (EKC) has been proven to be a useful tool in order to separate charged, neutral, and neutral and/or charged chiral species with short run times, high efficiencies and excellent resolution. EKC differs from capillary zone electrophoresis (CZE) in that a pseudostationary phase (PSP) is employed in order to separate analytes, providing selectivity that is not achievable in CZE. A variety of additives may be used as the PSP. Some examples are surfactants to form micelles, cyclodextrins (CDs), crown ethers, and polymers. In order to achieve chiral separations, a chiral additive or PSP must be utilized. Chromatographic figures of merit (CFOMs) have been evaluated for a variety of PSP formulations, including micelles, solvent-modified (swollen) micelles and microemulsions. The identity and concentration have also been evaluated and compared to previous formulations of PSPs researched within our group. Purity of the commonly used chiral surfactant in our lab, dodecylcarbonyl valine (DDCV), was evaluated under a variety of methods and its effect on CFOMs determined. Finally, a novel chiral surfactant was synthesized and evaluated under micellar electrokinetic chromatography (MEKC) conditions in order to provide an alternative to the chiral surfactant, DDCV.