Karyn Camilo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Karyn Camilo has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- Joe Preston Foley
Department of Chemistry, Drexel University, Philadelphia, USA
3 shared publications
Latest Publications
- 11 July 2022
- Published by Drexel University Libraries
Chiral and Achiral HPLC Separation of Chiral Pharmaceutical Compounds
This project is focused on developing a liquid chromatographic method that separates four Non-Steroidal Anti-Inflammatory Drugs (Ketoprofen, Naproxen, Ibuprofen, and Flurbiprofen) and three of the four pairs of enantiomers in one run. NSAID samples were prepared with 1 mg/mL of Ketoprofen, Naproxen, Ibuprofen, and Flurbiprofen, and 0.5 mg/mL thiourea as a t0 marker in a sample solvent consisting of 1:1 acetonitrile and 0.2% formic acid. The achiral separation of the compounds was investigated using four different columns and two simulations were used to consider the use of two achiral columns connected in tandem to achieve baseline separation of all compounds. The four columns investigated were a 5-cm C18 column, a 5-cm C8 column, a 5-cm perfluoro phenyl column, and a 5-cm biphenyl column. The two simulations were performed using the data from the 5-cm perfluoro phenyl column connected to the 5-cm biphenyl column and the 5-cm perfluoro phenyl column connected to the 5-cm C8 column. The separation of the enantiomers of the NSAIDs was investigated using a chiral column in two different lengths (5-cm, 10-cm) packed with Amylose tris(3,5-dimethylphenylcarbamate) coated on silica gel. The longer column was investigated first. The last method of separation explored utilized the 5-cm version of the aforementioned chiral column connected to each of the achiral columns used during the achiral separations using a zero dead volume column connector. The effect of column order on the retention time and resolution of the NSAIDs was investigated for all the achiral/chiral column combinations. Calculations were performed to predict the retention times and plate numbers for all of the achiral/chiral column combinations and were compared to the values obtained experimentally. The results of the chiral-only and tandem column runs, which employed a reversed-phase mobile phase comprised of aqueous 0.2% formic acid : acetonitrile (67 : 33 v/v), were compared to determine the benefits and drawbacks of each approach, with an emphasis on the resolution and analysis time.
- 11 July 2022
- Published by Drexel University Libraries
Chiral and Achiral HPLC Separation of Chiral Pharmaceutical Compounds
This project is focused on developing a liquid chromatographic method that separates four Non-Steroidal Anti-Inflammatory Drugs (Ketoprofen, Naproxen, Ibuprofen, and Flurbiprofen) and three of the four pairs of enantiomers in one run. NSAID samples were prepared with 1 mg/mL of Ketoprofen, Naproxen, Ibuprofen, and Flurbiprofen, and 0.5 mg/mL thiourea as a t0 marker in a sample solvent consisting of 1:1 acetonitrile and 0.2% formic acid. The achiral separation of the compounds was investigated using four different columns and two simulations were used to consider the use of two achiral columns connected in tandem to achieve baseline separation of all compounds. The four columns investigated were a 5-cm C18 column, a 5-cm C8 column, a 5-cm perfluoro phenyl column, and a 5-cm biphenyl column. The two simulations were performed using the data from the 5-cm perfluoro phenyl column connected to the 5-cm biphenyl column and the 5-cm perfluoro phenyl column connected to the 5-cm C8 column. The separation of the enantiomers of the NSAIDs was investigated using a chiral column in two different lengths (5-cm, 10-cm) packed with Amylose tris(3,5-dimethylphenylcarbamate) coated on silica gel. The longer column was investigated first. The last method of separation explored utilized the 5-cm version of the aforementioned chiral column connected to each of the achiral columns used during the achiral separations using a zero dead volume column connector. The effect of column order on the retention time and resolution of the NSAIDs was investigated for all the achiral/chiral column combinations. Calculations were performed to predict the retention times and plate numbers for all of the achiral/chiral column combinations and were compared to the values obtained experimentally. The results of the chiral-only and tandem column runs, which employed a reversed-phase mobile phase comprised of aqueous 0.2% formic acid : acetonitrile (67 : 33 v/v), were compared to determine the benefits and drawbacks of each approach, with an emphasis on the resolution and analysis time.
- 27 February 2021
- Published by Springer Nature in Chromatographia
- Vol. 84 (4) , 371-379
Simultaneous Achiral/Chiral HPLC Separation of Ketoprofen, Ibuprofen, Flurbiprofen, and Naproxen
- 27 February 2021
- Published by Springer Nature in Chromatographia
- Vol. 84 (4) , 371-379
Simultaneous Achiral/Chiral HPLC Separation of Ketoprofen, Ibuprofen, Flurbiprofen, and Naproxen
- Open Access
- 31 March 2020
- Published by American Chemical Society (ACS)
Chiral and achiral HPLC separation of NSAIDs
- 31 March 2020
- Published by American Chemical Society (ACS)
Open AccessChiral and achiral HPLC separation of NSAIDs