Dongxu Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dongxu Chen has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
Yanwen Zhou
School of Material and Metallurgy, University of Science and Technology Liaoning, Anshan, China
7 shared publications- Yanwen Zhou
University of Science and Technology Liaoning
6 shared publications - Qian Wang
School of Materials and Metallurgy, University of Science and Technology Liaoning, Anshan, People’s Republic of China
5 shared publications Tan Zhao
State Key Laboratory of Marine Equipment Steel and its Application, Anshan Iron and Steel Research Institute, AnGang Group
5 shared publicationsSai Li
School of Material and Metallurgy, University of Science and Technology Liaoning, Anshan, China
4 shared publicationsShengli Li
University of Science and Technology Liaoning
4 shared publications
Latest Publications
- Open Access
- 27 September 2026
- Published by Elsevier in SSRN Electronic Journal
SpikeForge-Det: Representation Recovery and Continuous-State Readout for Low-Timestep Spiking Object Detection
Low-timestep spiking object detection compresses multiscale visual representation formation and continuous geometric regression into only a few neuronal state updates. At T=2, two failure modes become dominant: unstable detection representations and quantization of localization evidence by binary spike readout. We present SpikeForge-Det, a 3.43M-parameter detector that addresses these problems through structure-aligned ANN-to-SNN representation recovery and pre-reset membrane-potential readout. An isomorphic ANN initializes the spatial detection pathway, while raw P3/P4/P5-grid distillation transfers box, objectness, and class knowledge without projection layers. A SinglePassSpikeConv stem avoids repeated dense convolution of static inputs, and a SpikeResidual backbone with an additive SpikeFPN propagates multiscale spiking features. The detection head reads the charged membrane state before firing and reset, preserving a continuous signal for bounding-box regression. On NEU-DET, the full model reaches 0.5722±0.0061 mAP50, 0.2431±0.0067 mAP50–95, 0.1642±0.0055 AP75, and 0.5385±0.0141 F1 over three seeds. Representation recovery raises mAP50–95 by 0.1048 over training from scratch. Membrane readout adds 0.0188 mAP50–95 and 0.0162 AP75 over spike readout, while reducing center and size errors. Its mAP advantage persists across all 15 corruption settings. Independent training on PASCAL VOC reproduces the consecutive gains from initialization and distillation in a 20-class detection task. Operation-level SynOps and energy proxies favor short temporal windows, whereas RTX 5090 measurements show that the current synchronous GPU implementation is slower and more energy-consuming than the ANN teacher. The results establish representation recovery and continuous-state readout as complementary mechanisms for accurate low-timestep spiking visual detection.
- 27 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessSpikeForge-Det: Representation Recovery and Continuous-State Readout for Low-Timestep Spiking Object Detection
Low-timestep spiking object detection compresses multiscale visual representation formation and continuous geometric regression into only a few neuronal state updates. At T=2, two failure modes become dominant: unstable detection representations and quantization of localization evidence by binary spike readout. We present SpikeForge-Det, a 3.43M-parameter detector that addresses these problems through structure-aligned ANN-to-SNN representation recovery and pre-reset membrane-potential readout. An isomorphic ANN initializes the spatial detection pathway, while raw P3/P4/P5-grid distillation transfers box, objectness, and class knowledge without projection layers. A SinglePassSpikeConv stem avoids repeated dense convolution of static inputs, and a SpikeResidual backbone with an additive SpikeFPN propagates multiscale spiking features. The detection head reads the charged membrane state before firing and reset, preserving a continuous signal for bounding-box regression. On NEU-DET, the full model reaches 0.5722±0.0061 mAP50, 0.2431±0.0067 mAP50–95, 0.1642±0.0055 AP75, and 0.5385±0.0141 F1 over three seeds. Representation recovery raises mAP50–95 by 0.1048 over training from scratch. Membrane readout adds 0.0188 mAP50–95 and 0.0162 AP75 over spike readout, while reducing center and size errors. Its mAP advantage persists across all 15 corruption settings. Independent training on PASCAL VOC reproduces the consecutive gains from initialization and distillation in a 20-class detection task. Operation-level SynOps and energy proxies favor short temporal windows, whereas RTX 5090 measurements show that the current synchronous GPU implementation is slower and more energy-consuming than the ANN teacher. The results establish representation recovery and continuous-state readout as complementary mechanisms for accurate low-timestep spiking visual detection.
- Open Access
- 1 September 2026
- Published by IOP Publishing in Materials Research Express
- Vol. 13 (17) , 176502
A novel device for in-situ study of the effect of electrode area ratio on crevice corrosion
A novel device that can study crevice corrosion (CC) of stainless steel (SS) in-situ has been designed. The influence law of cathode to anode area ratio ( S c / S a ) on the duration of 304 SS’s CC incubation period ( τ ) was monitored in real time using current noise. And the relationship model between S c / S a and the duration of τ was established. The magnitude of τ in CC was found to show a negative correlation with the value of S c / S a . The τ of CC becomes progressively shorter as the ratio increases, τ = 11.5 h as S c / S a = 1, and τ = 3.1 h as S c / S a = 25. The increase in S c / S a can increase the susceptibility of CC. The pH distribution within the crevice varied significantly with time under different S c / S a conditions. This leads to the growth of different corrosion product of 304 SS at different stages of CC.
- 1 September 2026
- Published by IOP Publishing in Materials Research Express
- Vol. 13 (17) , 176502
Open AccessA novel device for in-situ study of the effect of electrode area ratio on crevice corrosion
A novel device that can study crevice corrosion (CC) of stainless steel (SS) in-situ has been designed. The influence law of cathode to anode area ratio ( S c / S a ) on the duration of 304 SS’s CC incubation period ( τ ) was monitored in real time using current noise. And the relationship model between S c / S a and the duration of τ was established. The magnitude of τ in CC was found to show a negative correlation with the value of S c / S a . The τ of CC becomes progressively shorter as the ratio increases, τ = 11.5 h as S c / S a = 1, and τ = 3.1 h as S c / S a = 25. The increase in S c / S a can increase the susceptibility of CC. The pH distribution within the crevice varied significantly with time under different S c / S a conditions. This leads to the growth of different corrosion product of 304 SS at different stages of CC.
- Open Access
- 18 March 2026
- Published by Elsevier in SSRN Electronic Journal
Corrosion behavior and durability of Si-DLC films on high-strength steel under hydrostatic pressure
Mechanisms of hydrostatic pressure on corrosion behavior and durability of silicon-doped diamond-like carbon (Si-DLC) films prepared by plasma-enhanced chemical vapor deposition on the surface of GPa-grade ultra-high-strength steel (GPa steel) have been investigated under simulated deep-sea conditions. The results demonstrated that in 3.5 wt.% NaCl at 5°C with hydrostatic pressures of 0.1 to 8 MPa show that increasing pressure shifts the corrosion potential from −321.5 to −469.1 mV and raises the corrosion current density from 1.09 × 10−8 to 5.14 × 10−7 A•cm−2, indicating pressure-accelerated corrosion in the early stage. After 15 days exposure, film porosity at 0.1 MPa increases from 0.0056% to 0.3712% (≈66-fold), whereas at 8 MPa it rises by only about twofold due to the accumulation of dense α-FeOOH, Fe3O4 and SiO2 that replaces loose γ-FeOOH and blocks transport pathways. This pressure-induced self-healing effect shifts the rate-controlling step from charge-transfer to diffusion control and is quantitatively supported by the evolution of the activation volume |[[EQUATION]]|. The results demonstrate robust corrosion resistance of Si-DLC/GPa steel systems for deep-sea engineering applications.
- 18 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCorrosion behavior and durability of Si-DLC films on high-strength steel under hydrostatic pressure
Mechanisms of hydrostatic pressure on corrosion behavior and durability of silicon-doped diamond-like carbon (Si-DLC) films prepared by plasma-enhanced chemical vapor deposition on the surface of GPa-grade ultra-high-strength steel (GPa steel) have been investigated under simulated deep-sea conditions. The results demonstrated that in 3.5 wt.% NaCl at 5°C with hydrostatic pressures of 0.1 to 8 MPa show that increasing pressure shifts the corrosion potential from −321.5 to −469.1 mV and raises the corrosion current density from 1.09 × 10−8 to 5.14 × 10−7 A•cm−2, indicating pressure-accelerated corrosion in the early stage. After 15 days exposure, film porosity at 0.1 MPa increases from 0.0056% to 0.3712% (≈66-fold), whereas at 8 MPa it rises by only about twofold due to the accumulation of dense α-FeOOH, Fe3O4 and SiO2 that replaces loose γ-FeOOH and blocks transport pathways. This pressure-induced self-healing effect shifts the rate-controlling step from charge-transfer to diffusion control and is quantitatively supported by the evolution of the activation volume |[[EQUATION]]|. The results demonstrate robust corrosion resistance of Si-DLC/GPa steel systems for deep-sea engineering applications.
- 25 June 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 35 (2) , 1704-1714
Study on the Corrosion Resistance of Laser Remelting/Diamond-Like Carbon Composite Coatings on Stainless Steel Surface
- 25 June 2025
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 35 (2) , 1704-1714
Study on the Corrosion Resistance of Laser Remelting/Diamond-Like Carbon Composite Coatings on Stainless Steel Surface
- 6 February 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (3) , 035915
Pulse width effects on microstructure and electrochemical properties of DLC coatings deposited on high-strength Al alloy
This study employed cage-like hollow discharge plasma-enhanced chemical vapor deposition (PECVD) to synthesize diamond-like carbon (DLC) films on the 2024 aluminum alloy. The DLC coatings were deposited using varying pulse widths. The microstructural and mechanical properties of the films were evaluated using scanning electron microscopy (SEM), x-ray diffraction (XRD), atomic force microscopy (AFM), Raman spectroscopy, Fourier transform infrared spectroscopy (FTIR), Nano Indenter G200 device, and a tribometer model (MS-T3001). The anticorrosion behavior of the coatings in a 3.5 wt% NaCl solution was investigated using a range of electrochemical techniques. The results showed that increasing the pulse width to 20 μs led to the deposition of thicker films due to enhanced plasma density and deposition rate. Corrosion measurements revealed lower corrosion and passive current densities as pulse width increased. This behavior can be attributed to the thicker DLC film, which effectively reduces the presence of pores and inhibits corrosive species from attacking the bare alloy. Additionally, this study calculated and reported the thermodynamic corrosion parameters, including enthalpy of activation (∆H), entropy of activation, and activation energy (∆E) for the sample.
- 6 February 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (3) , 035915
Pulse width effects on microstructure and electrochemical properties of DLC coatings deposited on high-strength Al alloy
This study employed cage-like hollow discharge plasma-enhanced chemical vapor deposition (PECVD) to synthesize diamond-like carbon (DLC) films on the 2024 aluminum alloy. The DLC coatings were deposited using varying pulse widths. The microstructural and mechanical properties of the films were evaluated using scanning electron microscopy (SEM), x-ray diffraction (XRD), atomic force microscopy (AFM), Raman spectroscopy, Fourier transform infrared spectroscopy (FTIR), Nano Indenter G200 device, and a tribometer model (MS-T3001). The anticorrosion behavior of the coatings in a 3.5 wt% NaCl solution was investigated using a range of electrochemical techniques. The results showed that increasing the pulse width to 20 μs led to the deposition of thicker films due to enhanced plasma density and deposition rate. Corrosion measurements revealed lower corrosion and passive current densities as pulse width increased. This behavior can be attributed to the thicker DLC film, which effectively reduces the presence of pores and inhibits corrosive species from attacking the bare alloy. Additionally, this study calculated and reported the thermodynamic corrosion parameters, including enthalpy of activation (∆H), entropy of activation, and activation energy (∆E) for the sample.
- 13 May 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 32 (03)
A NOVEL MODEL FOR THE RELATIONSHIP BETWEEN THE HEALING TIME OF THE INERT FILM AND THE INCUBATION PERIOD OF LOCALIZED CORROSION
A model for the relationship between the healing time of the scratched diamond-like carbon (DLC) film and the localized corrosion incubation period of metal was established. Based on model calculations combined with experimental results, the scratched DLC film on 13Cr stainless steel was able to heal within 10–16[ ]h in NaCl solution with an adsorbent-type corrosion inhibitor. However, the localized corrosion incubation time was 30–40[ ]h. Healing of the scratched DLC film can be completed before localized corrosion occurs. This model provides a theoretical reference for the scratch-repassivation of inert films in corrosion inhibitors solutions.
- 13 May 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 32 (03)
A NOVEL MODEL FOR THE RELATIONSHIP BETWEEN THE HEALING TIME OF THE INERT FILM AND THE INCUBATION PERIOD OF LOCALIZED CORROSION
A model for the relationship between the healing time of the scratched diamond-like carbon (DLC) film and the localized corrosion incubation period of metal was established. Based on model calculations combined with experimental results, the scratched DLC film on 13Cr stainless steel was able to heal within 10–16[ ]h in NaCl solution with an adsorbent-type corrosion inhibitor. However, the localized corrosion incubation time was 30–40[ ]h. Healing of the scratched DLC film can be completed before localized corrosion occurs. This model provides a theoretical reference for the scratch-repassivation of inert films in corrosion inhibitors solutions.
- 27 November 2023
- Published by Elsevier in Ceramics International
- Vol. 50 (3) , 5516-5531
Oxidation behaviors of electrodeposited MoSi2 coating in a wide temperature range from 773 K to 1673 K
- 27 November 2023
- Published by Elsevier in Ceramics International
- Vol. 50 (3) , 5516-5531
Oxidation behaviors of electrodeposited MoSi2 coating in a wide temperature range from 773 K to 1673 K
- 28 September 2023
- Published by Elsevier in Thin Solid Films
- Vol. 784
Failure mechanisms of nitrogen-doped diamond-like carbon films: Exfoliation or localized attack behaviour of films under hydrochemistry evolution
- 28 September 2023
- Published by Elsevier in Thin Solid Films
- Vol. 784
Failure mechanisms of nitrogen-doped diamond-like carbon films: Exfoliation or localized attack behaviour of films under hydrochemistry evolution
- 1 August 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (8) , 082503
Effect of Reaction Temperature on the Molten Salt Electrodeposition of Silicide Coating on Molybdenum Substrate and its Oxidation Behavior
In this study, silicide coatings were successfully prepared on Mo substrates using NaCl-KCl-NaF molten salt as the reaction medium and K2SiF6 as the silicon source. The electrochemical reduction mechanism of Si(IV) was studied by cyclic voltammetry and chronoamperometry technology. The effect of reaction temperature on the phase composition, microstructure, and growth kinetics of the electrodeposited coatings were investigated in detail. The long-term oxidation behaviors of Mo and MoSi2-coated Mo samples at 873 K were also compared. The results revealed that the electrodeposition of silicide coatings was closely related to the reaction temperature. Dense and coherent single-layer MoSi2 coatings could be obtained at 1023 K and 1073 K, while double-layer coatings with inner MoSi2 layer and outer Si layer could be obtained at 1123 K. Under the same electrodeposition time, the overall thickness of the silicide coatings increased with the reaction temperature. Moreover, long-term oxidation tests at 873 K proved that MoSi2 coatings could effectively prevent the Mo substrate from oxidation. The mass gain of the MoSi2-coated Mo sample was only 0.46 wt% after 500 h of oxidation, which could be attributed to the formation of the continuous SiO2 protective layer.
- 1 August 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (8) , 082503
Effect of Reaction Temperature on the Molten Salt Electrodeposition of Silicide Coating on Molybdenum Substrate and its Oxidation Behavior
In this study, silicide coatings were successfully prepared on Mo substrates using NaCl-KCl-NaF molten salt as the reaction medium and K2SiF6 as the silicon source. The electrochemical reduction mechanism of Si(IV) was studied by cyclic voltammetry and chronoamperometry technology. The effect of reaction temperature on the phase composition, microstructure, and growth kinetics of the electrodeposited coatings were investigated in detail. The long-term oxidation behaviors of Mo and MoSi2-coated Mo samples at 873 K were also compared. The results revealed that the electrodeposition of silicide coatings was closely related to the reaction temperature. Dense and coherent single-layer MoSi2 coatings could be obtained at 1023 K and 1073 K, while double-layer coatings with inner MoSi2 layer and outer Si layer could be obtained at 1123 K. Under the same electrodeposition time, the overall thickness of the silicide coatings increased with the reaction temperature. Moreover, long-term oxidation tests at 873 K proved that MoSi2 coatings could effectively prevent the Mo substrate from oxidation. The mass gain of the MoSi2-coated Mo sample was only 0.46 wt% after 500 h of oxidation, which could be attributed to the formation of the continuous SiO2 protective layer.