Abdullah Al-Hussein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Abdullah Al-Hussein has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Achintya Haldar
University of Arizona
8 shared publications- Achintya Haldar
University of Arizona
8 shared publications - Fareed Hameed Majeed
Department of Civil Engineering, University of Basrah, Basra 61004, Iraq
3 shared publications A Das
1 shared publicationA Haldar
1 shared publicationA. Afiukwa Celestine
1 shared publication
Latest Publications
- Open Access
Damage Monitoring in Recycled Aggregate Concrete Reinforced with Hybrid Steel–Polyolefin Fibers Using Acoustic Emission Technique
The mechanical properties and real-time damage evolution of sustainable concrete (SC) containing 100% recycled concrete aggregate (RCA) under the combined action of hybrid steel and polyolefin fibers were studied. Inspired by solving the massive effects on the environment from construction waste, as well as to improve the lower mechanical performance of lower-grade RCA, the effect of combining high-stiffness hooked-end steel fibers and flexible macro-polyolefin fibers within RCA was investigated. Six different mix designs were considered: plain, single-fiber (100% steel and 100% polyolefin) and three hybrid composites with varying fractions of the steel/polyolefin fibers (25/75, 50/50, and 75/25). Compressive, tensile and flexural strengths were determined by mechanical testing. During compressive testing, the damage evolution was monitored using low-cost acoustic emission (AE) as a non-destructive technique. Cumulative hits analysis, amplitude distributions, and the statistical b-value parameter were used for damage characterization. The results show that steel fiber significantly increased compressive strength (an increase of up to 13.8%), and the 50/50 hybrid mix showed a high synergistic effect, yielding the highest tensile (4.86 MPa) and flexural (25.54 MPa) strengths. AE analysis identified different damage fingerprints: Based on amplitude analysis, steel-fiber composites exhibited high-amplitude events (which may be attributable to fiber pull-out); polyolefin-fiber composites generated medium-amplitude events (may have resulted from distributed microcracking); and hybrid mixes displayed a mixed amplitude distribution. The b-value analysis provided insight into progressive damage and revealed that the hybrid fibers induce stable, diffuse damage that prevents the brittle failure of plain recycled aggregate concrete (RAC). The results show that hybrid fiber reinforcement can be a reliable approach to enhance the mechanical performance and crack resistance of RAC. Furthermore, low-cost acoustic emission (AE) serves as an effective non-destructive method for monitoring damage progression within the material.
Open AccessDamage Monitoring in Recycled Aggregate Concrete Reinforced with Hybrid Steel–Polyolefin Fibers Using Acoustic Emission Technique
The mechanical properties and real-time damage evolution of sustainable concrete (SC) containing 100% recycled concrete aggregate (RCA) under the combined action of hybrid steel and polyolefin fibers were studied. Inspired by solving the massive effects on the environment from construction waste, as well as to improve the lower mechanical performance of lower-grade RCA, the effect of combining high-stiffness hooked-end steel fibers and flexible macro-polyolefin fibers within RCA was investigated. Six different mix designs were considered: plain, single-fiber (100% steel and 100% polyolefin) and three hybrid composites with varying fractions of the steel/polyolefin fibers (25/75, 50/50, and 75/25). Compressive, tensile and flexural strengths were determined by mechanical testing. During compressive testing, the damage evolution was monitored using low-cost acoustic emission (AE) as a non-destructive technique. Cumulative hits analysis, amplitude distributions, and the statistical b-value parameter were used for damage characterization. The results show that steel fiber significantly increased compressive strength (an increase of up to 13.8%), and the 50/50 hybrid mix showed a high synergistic effect, yielding the highest tensile (4.86 MPa) and flexural (25.54 MPa) strengths. AE analysis identified different damage fingerprints: Based on amplitude analysis, steel-fiber composites exhibited high-amplitude events (which may be attributable to fiber pull-out); polyolefin-fiber composites generated medium-amplitude events (may have resulted from distributed microcracking); and hybrid mixes displayed a mixed amplitude distribution. The b-value analysis provided insight into progressive damage and revealed that the hybrid fibers induce stable, diffuse damage that prevents the brittle failure of plain recycled aggregate concrete (RAC). The results show that hybrid fiber reinforcement can be a reliable approach to enhance the mechanical performance and crack resistance of RAC. Furthermore, low-cost acoustic emission (AE) serves as an effective non-destructive method for monitoring damage progression within the material.
- Open Access
- 6 October 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15  (5) , 27800-27809
Bond Performance of the Slurry Infiltrated Fiber Concrete Overlay on Normal Strength Concrete Substrate
Many concrete structures require strengthening or repair and a significant method of strengthening the Reinforced Concrete (RC) members is to add a concrete jacket. A type of concrete known as Slurry-Infiltrated Fiber Concrete (SIFCON) has come into use. SIFCON is a unique form of Fiber-Reinforced Concrete (FRC) known for its superior mechanical properties. The effectiveness of upgrading the RC members through jacketing depends on several factors, the most important of which is the bond performance between the substrate and overlay layers. This study examined how various factors influence the bonding performance between the SIFCON overlay and the Normal Strength Concrete (NSC) substrate. The research investigated the effects of surface preparation methods, types of bonding agents, and steel fiber geometry. Three tests were conducted to evaluate the bond strength: the Slant Shear Test (SST), Tensile Bond Test (TBT), and Flexural Bond Test (FBT). The surface preparation methods ranked from best to worst as follows: Grinding (G), Sandblasting (S), and Diamond Cutting (DC). The increase in the bond strength depended on the type of bonding agent and the surface preparation method. When the failure mode changed from Bond Interface (BI) to both BI and Weaker Concrete (BI-WC) or from BI-WC to WC, the increase was noticeable. If the failure mode shifted directly from BI to WC, the growth was significant. However, if the failure mode remained the same, the increase was minimal.
- 6 October 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15  (5) , 27800-27809
Open AccessBond Performance of the Slurry Infiltrated Fiber Concrete Overlay on Normal Strength Concrete Substrate
Many concrete structures require strengthening or repair and a significant method of strengthening the Reinforced Concrete (RC) members is to add a concrete jacket. A type of concrete known as Slurry-Infiltrated Fiber Concrete (SIFCON) has come into use. SIFCON is a unique form of Fiber-Reinforced Concrete (FRC) known for its superior mechanical properties. The effectiveness of upgrading the RC members through jacketing depends on several factors, the most important of which is the bond performance between the substrate and overlay layers. This study examined how various factors influence the bonding performance between the SIFCON overlay and the Normal Strength Concrete (NSC) substrate. The research investigated the effects of surface preparation methods, types of bonding agents, and steel fiber geometry. Three tests were conducted to evaluate the bond strength: the Slant Shear Test (SST), Tensile Bond Test (TBT), and Flexural Bond Test (FBT). The surface preparation methods ranked from best to worst as follows: Grinding (G), Sandblasting (S), and Diamond Cutting (DC). The increase in the bond strength depended on the type of bonding agent and the surface preparation method. When the failure mode changed from Bond Interface (BI) to both BI and Weaker Concrete (BI-WC) or from BI-WC to WC, the increase was noticeable. If the failure mode shifted directly from BI to WC, the growth was significant. However, if the failure mode remained the same, the increase was minimal.
- Open Access
Tension Lap Splices in Recycled-Aggregate Concrete Strengthened with Steel–Polyolefin Fibers
The bond strength of tension lap splices in recycled-coarse-aggregate-reinforced concrete strengthened with hybrid (steel–polyolefin) fibers was experimentally investigated. This study was conducted with the help of twelve lap-spliced beam specimens. The replacement level of coarse natural aggregates with recycled concrete aggregate (RCA) was 100%. The following variables were investigated: various ranges of steel–polyolefin fibers—100–0%, 75–25%, 50–50%, 25–75%, and 0–100%—in which the total volume fraction of fibers () remains constant at 1%; and two lengths of lap splices for rebars of 16 mm diameter (): 10 and 15 . The test results showed that the best range of steel–polyolefin fibers that gave the highest bond strength was 50–50%. The ductility of the fiber-reinforced recycled-aggregate (FR-RA) concrete was significantly improved for all the cases of various relative ratios of steel and polyolefin fibers. The bond strength was also predicted using three empirical equations proposed by Orangun et al., Darwin et al., and Harajli. This study showed that the Harajli equation gave a more accurate estimation of the bond strength of reinforcing bars embedded in FR-RA concrete than those proposed by Orangun et al. and Darwin et al.Open AccessTension Lap Splices in Recycled-Aggregate Concrete Strengthened with Steel–Polyolefin Fibers
The bond strength of tension lap splices in recycled-coarse-aggregate-reinforced concrete strengthened with hybrid (steel–polyolefin) fibers was experimentally investigated. This study was conducted with the help of twelve lap-spliced beam specimens. The replacement level of coarse natural aggregates with recycled concrete aggregate (RCA) was 100%. The following variables were investigated: various ranges of steel–polyolefin fibers—100–0%, 75–25%, 50–50%, 25–75%, and 0–100%—in which the total volume fraction of fibers () remains constant at 1%; and two lengths of lap splices for rebars of 16 mm diameter (): 10 and 15 . The test results showed that the best range of steel–polyolefin fibers that gave the highest bond strength was 50–50%. The ductility of the fiber-reinforced recycled-aggregate (FR-RA) concrete was significantly improved for all the cases of various relative ratios of steel and polyolefin fibers. The bond strength was also predicted using three empirical equations proposed by Orangun et al., Darwin et al., and Harajli. This study showed that the Harajli equation gave a more accurate estimation of the bond strength of reinforcing bars embedded in FR-RA concrete than those proposed by Orangun et al. and Darwin et al. - Open Access
- 1 January 2024
- Published by Walter de Gruyter GmbH in Open Engineering
- Vol. 14  (1)
Advancing seismic performance: Isolators, TMDs, and multi-level strategies in reinforced concrete buildings
This study evaluates seismic mitigation methods, including high damping rubber bearing, lead rubber bearing, double sliding pendulum (DSP), and tuned mass damper (TMD), considering earthquake intensity, building height, and isolation level. Moreover, the study delves into a novel approach that incorporates multi-level isolation and multi-level TMD. Reinforced concrete buildings, ranging in height from 4 to 40 storeys, were nalysed and nalysed using SAP2000 under the seismic influence of the Badra, El Centro, and Northridge earthquakes. The study reveals a significant rise in the fundamental period (T) with base isolation systems, reaching 378% of the fixed base value for a six-storey building. Building height directly affects T values, with simplified equations introduced for calculation. DSP proves 5% more efficient in reducing base shear (BS), while TMD is effective in weaker earthquakes for minimizing lateral displacement. Base isolators outperform mid-level isolation and TMD at the top storey. Combining base isolators with TMD at the top storey is deemed impractical and uneconomical. The study recommends multilevel isolation or multilevel TMD for enhanced seismic isolation efficiency, with four-level isolation achieving an 80% reduction in BS for 12-storey buildings. In addition, four-level TMD outperforms TMD at the top storey with a 44.5% reduction in BS, surpassing the 26.6% reduction achieved with TMD at the top storey only.
- 1 January 2024
- Published by Walter de Gruyter GmbH in Open Engineering
- Vol. 14  (1)
Open AccessAdvancing seismic performance: Isolators, TMDs, and multi-level strategies in reinforced concrete buildings
This study evaluates seismic mitigation methods, including high damping rubber bearing, lead rubber bearing, double sliding pendulum (DSP), and tuned mass damper (TMD), considering earthquake intensity, building height, and isolation level. Moreover, the study delves into a novel approach that incorporates multi-level isolation and multi-level TMD. Reinforced concrete buildings, ranging in height from 4 to 40 storeys, were nalysed and nalysed using SAP2000 under the seismic influence of the Badra, El Centro, and Northridge earthquakes. The study reveals a significant rise in the fundamental period (T) with base isolation systems, reaching 378% of the fixed base value for a six-storey building. Building height directly affects T values, with simplified equations introduced for calculation. DSP proves 5% more efficient in reducing base shear (BS), while TMD is effective in weaker earthquakes for minimizing lateral displacement. Base isolators outperform mid-level isolation and TMD at the top storey. Combining base isolators with TMD at the top storey is deemed impractical and uneconomical. The study recommends multilevel isolation or multilevel TMD for enhanced seismic isolation efficiency, with four-level isolation achieving an 80% reduction in BS for 12-storey buildings. In addition, four-level TMD outperforms TMD at the top storey with a 44.5% reduction in BS, surpassing the 26.6% reduction achieved with TMD at the top storey only.
- Open Access
Effect of Macro Polyolefin Fibers on Bond Strength of Tension Lap Splices in RC Beams
The effect of macro synthetic polyolefin fibers on the bond strength of tension lap splices in reinforced concrete (RC) beams is investigated in this study. The bond between the reinforcement and concrete plays a vital role in the strength of RC beams. The presence of polyolefin fibers in the lap splice zone confines the concrete and enhances the bond strength of the steel bars. The use of synthetic fibers is preferable to steel ones since steel suffers from corrosion over time. Tests were conducted on 12 full-scale beam specimens to determine the effect of fiber volume fraction (Vf), bar diameter (db) and concrete cover-to-bar diameter (c/db) on the response. Four volume fractions (Vf = 0, 0.5, 1 and 1.5%) of polyolefin fibers and three bar sizes (db = 16, 20 and 25 mm) with the corresponding (c/db = 2.31, 1.75 and 1.30) were considered to evaluate the bond strength. The test results demonstrated that the polyolefin fibers noticeably enhanced the bond strength and ductility of spliced tension bars. Experimental results were compared with those obtained from two theoretical methods including ACI Committee 318 design provisions. The results showed that the equation proposed by the ACI Committee overestimates the bond strength.
Open AccessEffect of Macro Polyolefin Fibers on Bond Strength of Tension Lap Splices in RC Beams
The effect of macro synthetic polyolefin fibers on the bond strength of tension lap splices in reinforced concrete (RC) beams is investigated in this study. The bond between the reinforcement and concrete plays a vital role in the strength of RC beams. The presence of polyolefin fibers in the lap splice zone confines the concrete and enhances the bond strength of the steel bars. The use of synthetic fibers is preferable to steel ones since steel suffers from corrosion over time. Tests were conducted on 12 full-scale beam specimens to determine the effect of fiber volume fraction (Vf), bar diameter (db) and concrete cover-to-bar diameter (c/db) on the response. Four volume fractions (Vf = 0, 0.5, 1 and 1.5%) of polyolefin fibers and three bar sizes (db = 16, 20 and 25 mm) with the corresponding (c/db = 2.31, 1.75 and 1.30) were considered to evaluate the bond strength. The test results demonstrated that the polyolefin fibers noticeably enhanced the bond strength and ductility of spliced tension bars. Experimental results were compared with those obtained from two theoretical methods including ACI Committee 318 design provisions. The results showed that the equation proposed by the ACI Committee overestimates the bond strength.
- 25 May 2021
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 26  (12) , 6475-6493
Health Assessment of Infrastructures Using Limited Uncertain Dynamic Response Information following Earthquakes
A health assessment technique for infrastructures is presented following earthquakes using uncertainty-filled information. A system identification (SI)-based concept is used to identify the stiffness of structural elements following earthquakes. The excitation information is not required, and responses need not be measured at all dynamic degrees of freedom. To consider uncertainty in representing a structure and dynamic responses, a significantly modified unscented Kalman filter (UKF)-based approach is used. To implement UKF, a two-stage SI approach is proposed. It is verified using three-dimensional truss-frame systems. The procedure is robust and not sensitive to the variances of initial stiffness and measurement noise, the two most uncertainty-prone parameters.
- 25 May 2021
- Published by Taylor & Francis in Journal of Earthquake Engineering
- Vol. 26  (12) , 6475-6493
Health Assessment of Infrastructures Using Limited Uncertain Dynamic Response Information following Earthquakes
A health assessment technique for infrastructures is presented following earthquakes using uncertainty-filled information. A system identification (SI)-based concept is used to identify the stiffness of structural elements following earthquakes. The excitation information is not required, and responses need not be measured at all dynamic degrees of freedom. To consider uncertainty in representing a structure and dynamic responses, a significantly modified unscented Kalman filter (UKF)-based approach is used. To implement UKF, a two-stage SI approach is proposed. It is verified using three-dimensional truss-frame systems. The procedure is robust and not sensitive to the variances of initial stiffness and measurement noise, the two most uncertainty-prone parameters.
- 22 June 2020
- Published by Sciencedomain International
Recent Advances in Science and Technology Research Vol. 2
This book covers all areas of science and technology. The contributions by the authors include moisture content; epoxy; dry strength; fatigue strength; composites manufacturing process; wind turbine blades; conductor catenary; constructional design; electrical loading; tower support weight; transmission lines; global warming as evolution; irreversible change; coordination failure; risk and uncertainty; GHC emissions and GDP; energy projections; CPR theory; cornucopianism; precautionism; coordination failure; complexities; solution strategies; health assessment; civil infrastructures; tuber types; proximate; minerals; toxic substances; Kutki millet; plot size thresher; traditional threshing; general combining ability; specific combining ability; brinjal; adaptive estimation; sound environment system; uncertainty; psychological evaluation; conceptual recognition; model; facial dyslipidemia; high active antiretroviral therapy; human immunodeficiency virus/ acquired immunodeficiency syndrome; hypercholesterolemia; hypertriacylglycerolaemia; lipid profiles; HIV/AIDS; parametric and nonparametric statistical methods; distribution of the data; level of measurin; energy-dispersive X-ray fluorescence; organic and elemental carbon etc. This book contains various materials suitable for students, researchers and academicians in the field of science and technology.
- 22 June 2020
- Published by Sciencedomain International
Recent Advances in Science and Technology Research Vol. 2
This book covers all areas of science and technology. The contributions by the authors include moisture content; epoxy; dry strength; fatigue strength; composites manufacturing process; wind turbine blades; conductor catenary; constructional design; electrical loading; tower support weight; transmission lines; global warming as evolution; irreversible change; coordination failure; risk and uncertainty; GHC emissions and GDP; energy projections; CPR theory; cornucopianism; precautionism; coordination failure; complexities; solution strategies; health assessment; civil infrastructures; tuber types; proximate; minerals; toxic substances; Kutki millet; plot size thresher; traditional threshing; general combining ability; specific combining ability; brinjal; adaptive estimation; sound environment system; uncertainty; psychological evaluation; conceptual recognition; model; facial dyslipidemia; high active antiretroviral therapy; human immunodeficiency virus/ acquired immunodeficiency syndrome; hypercholesterolemia; hypertriacylglycerolaemia; lipid profiles; HIV/AIDS; parametric and nonparametric statistical methods; distribution of the data; level of measurin; energy-dispersive X-ray fluorescence; organic and elemental carbon etc. This book contains various materials suitable for students, researchers and academicians in the field of science and technology.
- 1 January 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Aerospace Engineering
- Vol. 32  (1)
Condition Assessment of Civil Structures under Earthquake Excitation
This paper presents a nondestructive rapid condition or health assessment procedure of three-dimensional civil structures following strong earthquakes. It is a nonlinear time domain system identification procedure and structures are represented by finite elements. The excitation time history may not be available soon after an earthquake and is not required to implement the procedure. The response time histories measured at a small part of a large structure, denoted as a substructure, can be noise-contaminated. The location and severity of defects in an element are evaluated by comparing its stiffness parameter with the previous value or deviation from the other similar members. The basic unscented Kalman filter concept available in the literature is significantly improved, increasing its implementation potential. The improved concept is developed by integrating the iterative least-squares, weighted global iteration, and objective function algorithms. The proposed concept is verified by assessing the health of large three-dimensional structures excited by earthquake time histories. The procedure is capable of identifying defects with different levels of severity in small or large civil structures. This study also indicates that the inspection outcomes are not sensitive to the location and configuration of the substructure. The capability and efficiency of the procedure are demonstrated with three informative examples.
- 1 January 2019
- Published by American Society of Civil Engineers (ASCE) in Journal of Aerospace Engineering
- Vol. 32  (1)
Condition Assessment of Civil Structures under Earthquake Excitation
This paper presents a nondestructive rapid condition or health assessment procedure of three-dimensional civil structures following strong earthquakes. It is a nonlinear time domain system identification procedure and structures are represented by finite elements. The excitation time history may not be available soon after an earthquake and is not required to implement the procedure. The response time histories measured at a small part of a large structure, denoted as a substructure, can be noise-contaminated. The location and severity of defects in an element are evaluated by comparing its stiffness parameter with the previous value or deviation from the other similar members. The basic unscented Kalman filter concept available in the literature is significantly improved, increasing its implementation potential. The improved concept is developed by integrating the iterative least-squares, weighted global iteration, and objective function algorithms. The proposed concept is verified by assessing the health of large three-dimensional structures excited by earthquake time histories. The procedure is capable of identifying defects with different levels of severity in small or large civil structures. This study also indicates that the inspection outcomes are not sensitive to the location and configuration of the substructure. The capability and efficiency of the procedure are demonstrated with three informative examples.
- 1 January 2018
- Published by Inderscience Publishers in International Journal of Structural Engineering
- Vol. 9  (2) , 154
Nonlinear system identification from noisy measurements
A novel nonlinear system identification procedure using noisy measurements for health assessment of real civil infrastructure systems is presented. The important features of the procedure are that it can identify a structural system using only a limited number of highly noise-contaminated responses measured for a very short duration. To compensate for the use of very short duration response time-histories, multiple weighted global iteration (WGI) procedure is introduced in the unscented Kalman filter (UKF) algorithm to help the convergence process. It is denoted as UKF-WGI procedure. The algorithm is a finite element-based nonlinear system identification technique. It identifies not only the integrity of the whole structure, but also the locations and severity of the defects. Since no similar studies are reported in the literature, the superiority of UKF-WGI over the extended Kalman filter-based procedure in the presence of noise is established with the help of several illustrative examples.
- 1 January 2018
- Published by Inderscience Publishers in International Journal of Structural Engineering
- Vol. 9  (2) , 154
Nonlinear system identification from noisy measurements
A novel nonlinear system identification procedure using noisy measurements for health assessment of real civil infrastructure systems is presented. The important features of the procedure are that it can identify a structural system using only a limited number of highly noise-contaminated responses measured for a very short duration. To compensate for the use of very short duration response time-histories, multiple weighted global iteration (WGI) procedure is introduced in the unscented Kalman filter (UKF) algorithm to help the convergence process. It is denoted as UKF-WGI procedure. The algorithm is a finite element-based nonlinear system identification technique. It identifies not only the integrity of the whole structure, but also the locations and severity of the defects. Since no similar studies are reported in the literature, the superiority of UKF-WGI over the extended Kalman filter-based procedure in the presence of noise is established with the help of several illustrative examples.