Tomáš Vyskočil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tomáš Vyskočil has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Jan Stulik
Department of Spinal Surgery, First Faculty of Medicine, Charles University and University Hospital in Motol, Prague, Czech Republic
4 shared publications - Jan Kratochvíl
Charles University, Prague, Czech Republic
3 shared publications - Pavel Klavík
Charles University
3 shared publications - Yota Otachi
Nagoya University
3 shared publications - Ignaz Rutter
University of Passau, Passau, Germany
2 shared publications - Jan Kryl
Center for Spine Surgery, Motol University Hospital, Prague, Czech Republic
2 shared publications
Latest Publications
- Open Access
- 17 April 2019
- Published by MDPI AG in Algorithms
- Vol. 12 (4) , 77
Embedding Equality Constraints of Optimization Problems into a Quantum Annealer
Quantum annealers such as D-Wave machines are designed to propose solutions for quadratic unconstrained binary optimization (QUBO) problems by mapping them onto the quantum processing unit, which tries to find a solution by measuring the parameters of a minimum-energy state of the quantum system. While many NP-hard problems can be easily formulated as binary quadratic optimization problems, such formulations almost always contain one or more constraints, which are not allowed in a QUBO. Embedding such constraints as quadratic penalties is the standard approach for addressing this issue, but it has drawbacks such as the introduction of large coefficients and using too many additional qubits. In this paper, we propose an alternative approach for implementing constraints based on a combinatorial design and solving mixed-integer linear programming (MILP) problems in order to find better embeddings of constraints of the type for binary variables . Our approach is scalable to any number of variables and uses a linear number of ancillary variables for a fixed k.- 17 April 2019
- Published by MDPI AG in Algorithms
- Vol. 12 (4) , 77
Open AccessEmbedding Equality Constraints of Optimization Problems into a Quantum Annealer
Quantum annealers such as D-Wave machines are designed to propose solutions for quadratic unconstrained binary optimization (QUBO) problems by mapping them onto the quantum processing unit, which tries to find a solution by measuring the parameters of a minimum-energy state of the quantum system. While many NP-hard problems can be easily formulated as binary quadratic optimization problems, such formulations almost always contain one or more constraints, which are not allowed in a QUBO. Embedding such constraints as quadratic penalties is the standard approach for addressing this issue, but it has drawbacks such as the introduction of large coefficients and using too many additional qubits. In this paper, we propose an alternative approach for implementing constraints based on a combinatorial design and solving mixed-integer linear programming (MILP) problems in order to find better embeddings of constraints of the type for binary variables . Our approach is scalable to any number of variables and uses a linear number of ancillary variables for a fixed k. - 22 July 2016
- Published by Springer Nature in Algorithmica
- Vol. 78 (3) , 945-967
Extending Partial Representations of Interval Graphs
- 22 July 2016
- Published by Springer Nature in Algorithmica
- Vol. 78 (3) , 945-967
Extending Partial Representations of Interval Graphs
- 25 February 2016
- Published by Springer Nature in Algorithmica
- Vol. 77 (4) , 1071-1104
Extending Partial Representations of Proper and Unit Interval Graphs
- 25 February 2016
- Published by Springer Nature in Algorithmica
- Vol. 77 (4) , 1071-1104
Extending Partial Representations of Proper and Unit Interval Graphs
- 1 January 2014
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 253-264
Extending Partial Representations of Proper and Unit Interval Graphs
- 1 January 2014
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 253-264
Extending Partial Representations of Proper and Unit Interval Graphs
- 1 December 2010
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 23 (8) , e53-e58
Total Spondylectomy of C2
A report on 3 patients undergoing total spondylectomy of the C2 vertebra for tumor and the technique for C1-3 reconstruction. To illustrate the feasibility of complete resection of the C2 vertebra with preservation of the vertebral arteries and cervical nerve roots. Total spondylectomy provides improved progression free survival in many patients with locally aggressive spinal tumors. However, the perceived technical demands of effectively preserving both vertebral arteries, maintaining cervical nerve roots, and biomechanical reconstruction of the cranial-cervical junction often dissuades surgeons from carrying out total spondylectomy of the C2 vertebra. A review of 3 patients undergoing total C2 spondylectomy for tumor (thyroid adenocarcinoma, chordoma, and solitary plasmocytoma) was done. The surgical procedure that was undertaken and the technique used are described. Postoperatively, all 3 patients had uneventful postoperative recovery with gradual improvement in their neurologic functions. Preservation of bilateral vertebral arteries and all cervical nerve roots is feasible when carrying out intralesional total spondylectomy in patients with C2 vertebral body tumors and should be considered in patients thought to benefit from total C2 vertebra excision. In an attempt to augment construct stability and provide anterior column load sharing, we have used mesh cage and iliac crest graft between C1 and C3 held in place with a short cervical plate without complications.
- 1 December 2010
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 23 (8) , e53-e58
Total Spondylectomy of C2
A report on 3 patients undergoing total spondylectomy of the C2 vertebra for tumor and the technique for C1-3 reconstruction. To illustrate the feasibility of complete resection of the C2 vertebra with preservation of the vertebral arteries and cervical nerve roots. Total spondylectomy provides improved progression free survival in many patients with locally aggressive spinal tumors. However, the perceived technical demands of effectively preserving both vertebral arteries, maintaining cervical nerve roots, and biomechanical reconstruction of the cranial-cervical junction often dissuades surgeons from carrying out total spondylectomy of the C2 vertebra. A review of 3 patients undergoing total C2 spondylectomy for tumor (thyroid adenocarcinoma, chordoma, and solitary plasmocytoma) was done. The surgical procedure that was undertaken and the technique used are described. Postoperatively, all 3 patients had uneventful postoperative recovery with gradual improvement in their neurologic functions. Preservation of bilateral vertebral arteries and all cervical nerve roots is feasible when carrying out intralesional total spondylectomy in patients with C2 vertebral body tumors and should be considered in patients thought to benefit from total C2 vertebra excision. In an attempt to augment construct stability and provide anterior column load sharing, we have used mesh cage and iliac crest graft between C1 and C3 held in place with a short cervical plate without complications.
- 1 April 2009
- Published by Wolters Kluwer Health in Spine
- Vol. 34 (7) , 641-646
Implant Complications, Fusion, Loss of Lordosis, and Outcome After Anterior Cervical Plating With Dynamic or Rigid Plates
Prospective, controlled, randomized, multicenter study. To analyze implant complications and speed. Rigid plate designs, in which the screws are locked to the plate, are in common use and thought to provide more fixation than dynamic designs, in which the screws may glide when the graft is settling. The aim of the study is to analyze (1) implant complications, (2) speed of fusion, (3) loss of lordosis, and (4) clinical outcome in both types of plates. One hundred thirty-two patients were included and assigned by randomization to one of the groups in which they received a routine anterior cervical discectomy and autograft fusion with either a dynamic plate (ABC, study group) or a rigid plate (CSLP, control group). At discharge, after 3 and 6 months and finally after 2 years, implant complications, segmental mobility, absence of radiolucencies, absence of bone sclerosis, evidence of bridging trabecular bone, loss of lordosis, Visual Analog Scale (VAS) and Neck Disability Score were recorded. All radiographic measurements were performed by an independent radiologist. There have been 4 patients with implant complications within the control group and no implant complications within the study group, P = 0.045. Mean segmental mobility before discharge for the study group was 1.7 mm, 1.4 mm after 3 months, 0.8 mm after 6 months, and 0.4 mm after 2 years. For the control group, these values were 1.0, 1.8, 1.6, and 0.5 mm. The difference at 6 months between both groups was significant (P = 0.024). Neither absence of radiolucencies, nor absence of sclerosis, nor evidence of bridging bone showed significant differences between the 2 groups through the postoperative follow-up (P > 0.05). The loss of segmental lordosis for the study group with respect to intraoperative radiograph was 1.3 degrees at discharge and 4.3 degrees after 2 years. For the control group, these values were 0.9 degrees , 0.7 degrees . The difference at 2 years was significant (P = 0.003). Clinical postoperative outcome (VAS and ODI) was not different between the 2 groups through the postoperative follow-up (P > 0.05). Dynamic cervical plate designs provide less implant complications (no patient) compared with rigid plate designs (4 patients). Speed of fusion was faster in the presence of a dynamic plate. However, loss of segmental lordosis is significantly higher if dynamic plates are used, which did not result in differences regarding clinical outcome between dynamic and constrained plates after 2 years. Thus, dynamic plates should be considered to be the preferred treatment option because of the lower risk for implant failure-related revision surgery.
- 1 April 2009
- Published by Wolters Kluwer Health in Spine
- Vol. 34 (7) , 641-646
Implant Complications, Fusion, Loss of Lordosis, and Outcome After Anterior Cervical Plating With Dynamic or Rigid Plates
Prospective, controlled, randomized, multicenter study. To analyze implant complications and speed. Rigid plate designs, in which the screws are locked to the plate, are in common use and thought to provide more fixation than dynamic designs, in which the screws may glide when the graft is settling. The aim of the study is to analyze (1) implant complications, (2) speed of fusion, (3) loss of lordosis, and (4) clinical outcome in both types of plates. One hundred thirty-two patients were included and assigned by randomization to one of the groups in which they received a routine anterior cervical discectomy and autograft fusion with either a dynamic plate (ABC, study group) or a rigid plate (CSLP, control group). At discharge, after 3 and 6 months and finally after 2 years, implant complications, segmental mobility, absence of radiolucencies, absence of bone sclerosis, evidence of bridging trabecular bone, loss of lordosis, Visual Analog Scale (VAS) and Neck Disability Score were recorded. All radiographic measurements were performed by an independent radiologist. There have been 4 patients with implant complications within the control group and no implant complications within the study group, P = 0.045. Mean segmental mobility before discharge for the study group was 1.7 mm, 1.4 mm after 3 months, 0.8 mm after 6 months, and 0.4 mm after 2 years. For the control group, these values were 1.0, 1.8, 1.6, and 0.5 mm. The difference at 6 months between both groups was significant (P = 0.024). Neither absence of radiolucencies, nor absence of sclerosis, nor evidence of bridging bone showed significant differences between the 2 groups through the postoperative follow-up (P > 0.05). The loss of segmental lordosis for the study group with respect to intraoperative radiograph was 1.3 degrees at discharge and 4.3 degrees after 2 years. For the control group, these values were 0.9 degrees , 0.7 degrees . The difference at 2 years was significant (P = 0.003). Clinical postoperative outcome (VAS and ODI) was not different between the 2 groups through the postoperative follow-up (P > 0.05). Dynamic cervical plate designs provide less implant complications (no patient) compared with rigid plate designs (4 patients). Speed of fusion was faster in the presence of a dynamic plate. However, loss of segmental lordosis is significantly higher if dynamic plates are used, which did not result in differences regarding clinical outcome between dynamic and constrained plates after 2 years. Thus, dynamic plates should be considered to be the preferred treatment option because of the lower risk for implant failure-related revision surgery.
- Open Access
- 8 August 2007
- Published by Springer Nature in European Spine Journal
- Vol. 16 (10) , 1689-1694
Fusion and failure following anterior cervical plating with dynamic or rigid plates: 6-months results of a multi-centric, prospective, randomized, controlled study
Anterior cervical plate fixation is an approved surgical technique for cervical spine stabilization in the presence of anterior cervical instability. Rigid plate design with screws rigidly locked to the plate is widely used and is thought to provide a better fixation for the treated spinal segment than a dynamic design in which the screws may slide when the graft is settling. Recent biomechanical studies showed that dynamic anterior plates provide a better graft loading possibly leading to accelerated spinal fusion with a lower incidence of implant complications. This, however, was investigated in vitro and does not necessarily mean to be the case in vivo, as well. Thus, the two major aspects of this study were to compare the speed of bone fusion and the rate of implant complications using either rigid- or dynamic plates. The study design is prospective, randomized, controlled, and multi-centric, having been approved by respective ethic committees of all participating sites. One hundred and thirty-two patients were included in this study and randomly assigned to one of the two groups, both undergoing routine level-1- or level-2 anterior cervical discectomy with autograft fusion receiving either a dynamic plate with screws being locked in ap - position (ABC, Aesculap, Germany), or a rigid plate (CSLP, Synthes, Switzerland). Segmental mobility and implant complications were compared after 3- and 6 months, respectively. All measurements were performed by an independent radiologist. Mobility results after 6 months were available for 77 patients (43 ABC/34 CSLP). Mean segmental mobility for the ABC group was 1.7 mm at the time of discharge, 1.4 mm after 3 months, and 0.8 mm after 6 months. For the CSLP- group the measurements were 1.0, 1.8, and 1.7 mm, respectively. The differences of mean segmental mobility were statistically significant between both groups after 6 months (P = 0.02). Four patients of the CSLP-group demonstrated surgical hardware complications, whereas no implant complications were observed within the ABC-group (P = 0.0375). Dynamic plate designs provided a faster fusion of the cervical spine compared with rigid plate designs after prior spinal surgery. Moreover, the rate of implant complications was lower within the group of patients receiving a dynamic plate. These interim results refer to a follow-up period of 6 months after prior spinal surgery. Further investigations will be performed 2 years postoperatively.
- 8 August 2007
- Published by Springer Nature in European Spine Journal
- Vol. 16 (10) , 1689-1694
Open AccessFusion and failure following anterior cervical plating with dynamic or rigid plates: 6-months results of a multi-centric, prospective, randomized, controlled study
Anterior cervical plate fixation is an approved surgical technique for cervical spine stabilization in the presence of anterior cervical instability. Rigid plate design with screws rigidly locked to the plate is widely used and is thought to provide a better fixation for the treated spinal segment than a dynamic design in which the screws may slide when the graft is settling. Recent biomechanical studies showed that dynamic anterior plates provide a better graft loading possibly leading to accelerated spinal fusion with a lower incidence of implant complications. This, however, was investigated in vitro and does not necessarily mean to be the case in vivo, as well. Thus, the two major aspects of this study were to compare the speed of bone fusion and the rate of implant complications using either rigid- or dynamic plates. The study design is prospective, randomized, controlled, and multi-centric, having been approved by respective ethic committees of all participating sites. One hundred and thirty-two patients were included in this study and randomly assigned to one of the two groups, both undergoing routine level-1- or level-2 anterior cervical discectomy with autograft fusion receiving either a dynamic plate with screws being locked in ap - position (ABC, Aesculap, Germany), or a rigid plate (CSLP, Synthes, Switzerland). Segmental mobility and implant complications were compared after 3- and 6 months, respectively. All measurements were performed by an independent radiologist. Mobility results after 6 months were available for 77 patients (43 ABC/34 CSLP). Mean segmental mobility for the ABC group was 1.7 mm at the time of discharge, 1.4 mm after 3 months, and 0.8 mm after 6 months. For the CSLP- group the measurements were 1.0, 1.8, and 1.7 mm, respectively. The differences of mean segmental mobility were statistically significant between both groups after 6 months (P = 0.02). Four patients of the CSLP-group demonstrated surgical hardware complications, whereas no implant complications were observed within the ABC-group (P = 0.0375). Dynamic plate designs provided a faster fusion of the cervical spine compared with rigid plate designs after prior spinal surgery. Moreover, the rate of implant complications was lower within the group of patients receiving a dynamic plate. These interim results refer to a follow-up period of 6 months after prior spinal surgery. Further investigations will be performed 2 years postoperatively.
- 19 October 2006
- Published by Springer Nature in European Spine Journal
- Vol. 16 (4) , 479-484
Atlantoaxial fixation using the polyaxial screw–rod system
The aim of this study is to evaluate the first results of the atlantoaxial fixation using polyaxial screw–rod system. Twenty-eight patients followed-up 12–29 months (average 17.1 months) were included in this study. The average age was 59.5 years (range 23–89 years). The atlantoaxial fusion was employed in 20 patients for an acute injury to the upper cervical spine, in 1 patient with rheumatoid arthritis for atlantoaxial vertical instability, in 1 patient for C1–C2 osteoarthritis, in 2 patients for malunion of the fractured dens. Temporary fixation was applied in two patients for type III displaced fractures of the dens and in two patients for the atlantoaxial rotatory dislocation. Retrospectively, we evaluated operative time, intraoperative bleeding and the interval of X-ray exposure. The resulting condition was subjectively evaluated by patients. We evaluated also the placement, direction and length of the screws. Fusion or stability in the temporary fixation was evaluated on radiographs taken at 3, 6, 12 weeks and 6 and 12 months after the surgery. As concerns complications, intraoperatively we monitored injury of the nerve structures and the vertebral artery. Monitoring of postoperative complications was focused on delayed healing of the wound, breaking or loosening of screws and development of malunion. Operative time ranged from 35 to 155 min, (average 83 min). Intraoperative blood loss ranged from 50 to 1,500 ml (average 540 ml). The image intensifier was used for a period of 24 s to 2 min 36 s (average 1 min 6 s). Within the postoperative evaluation, four patients complained of paresthesia in the region innervated by the greater occipital nerve. A total of 56 screws were inserted into C1, their length ranged from 26 to 34 mm (average, 30.8 mm). All screws were positioned correctly in the C1 lateral mass. Another 56 screws were inserted into C2. Their length ranged from 28 to 36 mm (average 31.4 mm). Three screws were malpositioned: one screw perforated the spinal canal and two screws protruded into the vertebral artery canal. C1–C2 stability was achieved in all patients 12 weeks after the surgery. No clinically manifested injury of the vertebral artery or nerve structures was observed in any of these cases. As for postoperative complications, we recorded wound dehiscence in one patient. The Harms C1–C2 fixation is a very effective method of stabilizing the atlantoaxial complex. The possibility of a temporary fixation without damage to the atlantoaxial joints and of reduction after the screws and rods had been inserted is quite unique.
- 19 October 2006
- Published by Springer Nature in European Spine Journal
- Vol. 16 (4) , 479-484
Atlantoaxial fixation using the polyaxial screw–rod system
The aim of this study is to evaluate the first results of the atlantoaxial fixation using polyaxial screw–rod system. Twenty-eight patients followed-up 12–29 months (average 17.1 months) were included in this study. The average age was 59.5 years (range 23–89 years). The atlantoaxial fusion was employed in 20 patients for an acute injury to the upper cervical spine, in 1 patient with rheumatoid arthritis for atlantoaxial vertical instability, in 1 patient for C1–C2 osteoarthritis, in 2 patients for malunion of the fractured dens. Temporary fixation was applied in two patients for type III displaced fractures of the dens and in two patients for the atlantoaxial rotatory dislocation. Retrospectively, we evaluated operative time, intraoperative bleeding and the interval of X-ray exposure. The resulting condition was subjectively evaluated by patients. We evaluated also the placement, direction and length of the screws. Fusion or stability in the temporary fixation was evaluated on radiographs taken at 3, 6, 12 weeks and 6 and 12 months after the surgery. As concerns complications, intraoperatively we monitored injury of the nerve structures and the vertebral artery. Monitoring of postoperative complications was focused on delayed healing of the wound, breaking or loosening of screws and development of malunion. Operative time ranged from 35 to 155 min, (average 83 min). Intraoperative blood loss ranged from 50 to 1,500 ml (average 540 ml). The image intensifier was used for a period of 24 s to 2 min 36 s (average 1 min 6 s). Within the postoperative evaluation, four patients complained of paresthesia in the region innervated by the greater occipital nerve. A total of 56 screws were inserted into C1, their length ranged from 26 to 34 mm (average, 30.8 mm). All screws were positioned correctly in the C1 lateral mass. Another 56 screws were inserted into C2. Their length ranged from 28 to 36 mm (average 31.4 mm). Three screws were malpositioned: one screw perforated the spinal canal and two screws protruded into the vertebral artery canal. C1–C2 stability was achieved in all patients 12 weeks after the surgery. No clinically manifested injury of the vertebral artery or nerve structures was observed in any of these cases. As for postoperative complications, we recorded wound dehiscence in one patient. The Harms C1–C2 fixation is a very effective method of stabilizing the atlantoaxial complex. The possibility of a temporary fixation without damage to the atlantoaxial joints and of reduction after the screws and rods had been inserted is quite unique.