Jan Kryl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jan Kryl has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Jan Stulik
Department of Spinal Surgery, First Faculty of Medicine, Charles University and University Hospital in Motol, Prague, Czech Republic
4 shared publications - Tomáš Vyskočil
Department of Computer Science, Rutgers, The State University of New Jersey, Piscataway, USA
2 shared publications - Zdenek Klezl
Royal Derby Hospital
2 shared publications Bernhard Bruchmann
Spinal Surgery, Katholisches Klinikum Koblenz, Germany
1 shared publicationChristian Woiciechowsky
Neurosurgery and Spine Surgery, Spine Center Berlin, Germany
1 shared publicationFabrizio Caroli
Neurosurgery, "Regina Elena" National Cancer Institute, Rome, Italy
1 shared publication
Latest Publications
- 1 November 2016
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 25 (5) , 556-565
Four-year results of a prospective single-arm study on 200 semi-constrained total cervical disc prostheses: clinical and radiographic outcome
OBJECTIVE: Recent studies have described encouraging outcomes after cervical total disc replacement (cTDR), but there are also critical debates regarding the long-term effects of heterotopic ossification (HO) and the prevalence of adjacent-level degeneration. The aim in this paper was to provide 4-year clinical and radiographic outcome results on the activ C disc prosthesis. METHODS: A total of 200 subjects underwent single-level activ C (Aesculap AG) implantation between C-3 and C-7 for the treatment of symptomatic degenerative disc disease. Clinical and radiographic assessments were performed preoperatively, intraoperatively, at discharge, and again at 6 weeks, 6 months, 1 year, 2 years, and 4 years. Radiographic evaluations were done by an independent core laboratory using a specific software for quantitative motion analysis. RESULTS: Neck Disability Index (NDI) and visual analog scale (VAS) score for neck and arm pain decreased significantly from baseline to the 4-year follow-up. The mean improvement for NDI was 20, for VAS severity and frequency of neck pain 26.4 and 28, and for VAS severity and frequency of arm pain 30.7 and 35.1, respectively. The neurological situation improved for the majority of patients (86.4%); 76.1% of cases were asymptomatic. Subsequent surgical interventions were reported in 7% of the cases, including device removals in 3%. In 2.5% a subsidence greater than 3 mm was recorded; 1 of these cases also had a migration greater than 3 mm. No device displacement, expulsion, disassembly, loose or fractured device, osteolysis, or facet joint degeneration at the index level was observed. Segmental lordotic alignment changed from −2.4° preoperatively to −6.2° at 4 years, and postoperative height was maintained during the follow-up. Advanced HO (Grade III and IV) was present in 27.1% of the cases; 82.4% showed segmental mobility. A progression of radiographic adjacent-segment degeneration occurred in 28.2%, but only 4.5% required surgical treatment. CONCLUSIONS: The activ C is a safe and effective device for cervical disc replacement confirming the encouraging results after cTDR. Clinical trial registration no.: NCT02492724 (clinicaltrials.gov)
- 1 November 2016
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 25 (5) , 556-565
Four-year results of a prospective single-arm study on 200 semi-constrained total cervical disc prostheses: clinical and radiographic outcome
OBJECTIVE: Recent studies have described encouraging outcomes after cervical total disc replacement (cTDR), but there are also critical debates regarding the long-term effects of heterotopic ossification (HO) and the prevalence of adjacent-level degeneration. The aim in this paper was to provide 4-year clinical and radiographic outcome results on the activ C disc prosthesis. METHODS: A total of 200 subjects underwent single-level activ C (Aesculap AG) implantation between C-3 and C-7 for the treatment of symptomatic degenerative disc disease. Clinical and radiographic assessments were performed preoperatively, intraoperatively, at discharge, and again at 6 weeks, 6 months, 1 year, 2 years, and 4 years. Radiographic evaluations were done by an independent core laboratory using a specific software for quantitative motion analysis. RESULTS: Neck Disability Index (NDI) and visual analog scale (VAS) score for neck and arm pain decreased significantly from baseline to the 4-year follow-up. The mean improvement for NDI was 20, for VAS severity and frequency of neck pain 26.4 and 28, and for VAS severity and frequency of arm pain 30.7 and 35.1, respectively. The neurological situation improved for the majority of patients (86.4%); 76.1% of cases were asymptomatic. Subsequent surgical interventions were reported in 7% of the cases, including device removals in 3%. In 2.5% a subsidence greater than 3 mm was recorded; 1 of these cases also had a migration greater than 3 mm. No device displacement, expulsion, disassembly, loose or fractured device, osteolysis, or facet joint degeneration at the index level was observed. Segmental lordotic alignment changed from −2.4° preoperatively to −6.2° at 4 years, and postoperative height was maintained during the follow-up. Advanced HO (Grade III and IV) was present in 27.1% of the cases; 82.4% showed segmental mobility. A progression of radiographic adjacent-segment degeneration occurred in 28.2%, but only 4.5% required surgical treatment. CONCLUSIONS: The activ C is a safe and effective device for cervical disc replacement confirming the encouraging results after cTDR. Clinical trial registration no.: NCT02492724 (clinicaltrials.gov)
- Open Access
- 1 January 2014
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 8 (1) , 59-63
Incidence of Vascular Complications Arising from Anterior Spinal Surgery in the Thoraco-Lumbar Spine
Klezl Z, et al. Asian Spine J. 2014 Feb;8(1):59-63. http://dx.doi.org/10.4184/asj.2014.8.1.59
- 1 January 2014
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 8 (1) , 59-63
Open AccessIncidence of Vascular Complications Arising from Anterior Spinal Surgery in the Thoraco-Lumbar Spine
Klezl Z, et al. Asian Spine J. 2014 Feb;8(1):59-63. http://dx.doi.org/10.4184/asj.2014.8.1.59
- 1 December 2010
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 23 (8) , e53-e58
Total Spondylectomy of C2
A report on 3 patients undergoing total spondylectomy of the C2 vertebra for tumor and the technique for C1-3 reconstruction. To illustrate the feasibility of complete resection of the C2 vertebra with preservation of the vertebral arteries and cervical nerve roots. Total spondylectomy provides improved progression free survival in many patients with locally aggressive spinal tumors. However, the perceived technical demands of effectively preserving both vertebral arteries, maintaining cervical nerve roots, and biomechanical reconstruction of the cranial-cervical junction often dissuades surgeons from carrying out total spondylectomy of the C2 vertebra. A review of 3 patients undergoing total C2 spondylectomy for tumor (thyroid adenocarcinoma, chordoma, and solitary plasmocytoma) was done. The surgical procedure that was undertaken and the technique used are described. Postoperatively, all 3 patients had uneventful postoperative recovery with gradual improvement in their neurologic functions. Preservation of bilateral vertebral arteries and all cervical nerve roots is feasible when carrying out intralesional total spondylectomy in patients with C2 vertebral body tumors and should be considered in patients thought to benefit from total C2 vertebra excision. In an attempt to augment construct stability and provide anterior column load sharing, we have used mesh cage and iliac crest graft between C1 and C3 held in place with a short cervical plate without complications.
- 1 December 2010
- Published by Wolters Kluwer Health in Journal of Spinal Disorders & Techniques
- Vol. 23 (8) , e53-e58
Total Spondylectomy of C2
A report on 3 patients undergoing total spondylectomy of the C2 vertebra for tumor and the technique for C1-3 reconstruction. To illustrate the feasibility of complete resection of the C2 vertebra with preservation of the vertebral arteries and cervical nerve roots. Total spondylectomy provides improved progression free survival in many patients with locally aggressive spinal tumors. However, the perceived technical demands of effectively preserving both vertebral arteries, maintaining cervical nerve roots, and biomechanical reconstruction of the cranial-cervical junction often dissuades surgeons from carrying out total spondylectomy of the C2 vertebra. A review of 3 patients undergoing total C2 spondylectomy for tumor (thyroid adenocarcinoma, chordoma, and solitary plasmocytoma) was done. The surgical procedure that was undertaken and the technique used are described. Postoperatively, all 3 patients had uneventful postoperative recovery with gradual improvement in their neurologic functions. Preservation of bilateral vertebral arteries and all cervical nerve roots is feasible when carrying out intralesional total spondylectomy in patients with C2 vertebral body tumors and should be considered in patients thought to benefit from total C2 vertebra excision. In an attempt to augment construct stability and provide anterior column load sharing, we have used mesh cage and iliac crest graft between C1 and C3 held in place with a short cervical plate without complications.
- 19 October 2006
- Published by Springer Nature in European Spine Journal
- Vol. 16 (4) , 479-484
Atlantoaxial fixation using the polyaxial screw–rod system
The aim of this study is to evaluate the first results of the atlantoaxial fixation using polyaxial screw–rod system. Twenty-eight patients followed-up 12–29 months (average 17.1 months) were included in this study. The average age was 59.5 years (range 23–89 years). The atlantoaxial fusion was employed in 20 patients for an acute injury to the upper cervical spine, in 1 patient with rheumatoid arthritis for atlantoaxial vertical instability, in 1 patient for C1–C2 osteoarthritis, in 2 patients for malunion of the fractured dens. Temporary fixation was applied in two patients for type III displaced fractures of the dens and in two patients for the atlantoaxial rotatory dislocation. Retrospectively, we evaluated operative time, intraoperative bleeding and the interval of X-ray exposure. The resulting condition was subjectively evaluated by patients. We evaluated also the placement, direction and length of the screws. Fusion or stability in the temporary fixation was evaluated on radiographs taken at 3, 6, 12 weeks and 6 and 12 months after the surgery. As concerns complications, intraoperatively we monitored injury of the nerve structures and the vertebral artery. Monitoring of postoperative complications was focused on delayed healing of the wound, breaking or loosening of screws and development of malunion. Operative time ranged from 35 to 155 min, (average 83 min). Intraoperative blood loss ranged from 50 to 1,500 ml (average 540 ml). The image intensifier was used for a period of 24 s to 2 min 36 s (average 1 min 6 s). Within the postoperative evaluation, four patients complained of paresthesia in the region innervated by the greater occipital nerve. A total of 56 screws were inserted into C1, their length ranged from 26 to 34 mm (average, 30.8 mm). All screws were positioned correctly in the C1 lateral mass. Another 56 screws were inserted into C2. Their length ranged from 28 to 36 mm (average 31.4 mm). Three screws were malpositioned: one screw perforated the spinal canal and two screws protruded into the vertebral artery canal. C1–C2 stability was achieved in all patients 12 weeks after the surgery. No clinically manifested injury of the vertebral artery or nerve structures was observed in any of these cases. As for postoperative complications, we recorded wound dehiscence in one patient. The Harms C1–C2 fixation is a very effective method of stabilizing the atlantoaxial complex. The possibility of a temporary fixation without damage to the atlantoaxial joints and of reduction after the screws and rods had been inserted is quite unique.
- 19 October 2006
- Published by Springer Nature in European Spine Journal
- Vol. 16 (4) , 479-484
Atlantoaxial fixation using the polyaxial screw–rod system
The aim of this study is to evaluate the first results of the atlantoaxial fixation using polyaxial screw–rod system. Twenty-eight patients followed-up 12–29 months (average 17.1 months) were included in this study. The average age was 59.5 years (range 23–89 years). The atlantoaxial fusion was employed in 20 patients for an acute injury to the upper cervical spine, in 1 patient with rheumatoid arthritis for atlantoaxial vertical instability, in 1 patient for C1–C2 osteoarthritis, in 2 patients for malunion of the fractured dens. Temporary fixation was applied in two patients for type III displaced fractures of the dens and in two patients for the atlantoaxial rotatory dislocation. Retrospectively, we evaluated operative time, intraoperative bleeding and the interval of X-ray exposure. The resulting condition was subjectively evaluated by patients. We evaluated also the placement, direction and length of the screws. Fusion or stability in the temporary fixation was evaluated on radiographs taken at 3, 6, 12 weeks and 6 and 12 months after the surgery. As concerns complications, intraoperatively we monitored injury of the nerve structures and the vertebral artery. Monitoring of postoperative complications was focused on delayed healing of the wound, breaking or loosening of screws and development of malunion. Operative time ranged from 35 to 155 min, (average 83 min). Intraoperative blood loss ranged from 50 to 1,500 ml (average 540 ml). The image intensifier was used for a period of 24 s to 2 min 36 s (average 1 min 6 s). Within the postoperative evaluation, four patients complained of paresthesia in the region innervated by the greater occipital nerve. A total of 56 screws were inserted into C1, their length ranged from 26 to 34 mm (average, 30.8 mm). All screws were positioned correctly in the C1 lateral mass. Another 56 screws were inserted into C2. Their length ranged from 28 to 36 mm (average 31.4 mm). Three screws were malpositioned: one screw perforated the spinal canal and two screws protruded into the vertebral artery canal. C1–C2 stability was achieved in all patients 12 weeks after the surgery. No clinically manifested injury of the vertebral artery or nerve structures was observed in any of these cases. As for postoperative complications, we recorded wound dehiscence in one patient. The Harms C1–C2 fixation is a very effective method of stabilizing the atlantoaxial complex. The possibility of a temporary fixation without damage to the atlantoaxial joints and of reduction after the screws and rods had been inserted is quite unique.