CWCraig Weinschenk

Craig Weinschenk

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Craig Weinschenk has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Quantifying the Fire Hazard from Li-Ion Battery Fires Caused by Thermal Runaway in E-scooters

    by Charles Fleischmann, Craig Weinschenk, Daniel Madrzykowski, Alexandra Schraiber, Benjamin Gaudet


  • Open Access

    Toward improved thermal exposure classes for structural firefighters

    by Craig Weinschenk, Holli Knight, John W Regan

    In the early 1970s, there was an initial effort to quantify the conditions under which firefighters are expected to perform. Harvey Utech led this endeavor by defining three levels of thermal exposure—routine, ordinary, and emergency—which were characterized by combining a range of air temperatures and radiative heat fluxes. In the last half-century, there has been a concerted scientific effort to further understand the conditions to which firefighters are exposed during structural firefighting. Research has been conducted on the resiliency of turnout gear and facepiece lenses, the thermal conditions observed during a structure fire, and the impact of firefighter tactics such as ventilation and suppression. The authors synthesize the results from these research areas to update the original thermal classifications to six categories of exposure—routine, Ordinary I, Ordinary II, Emergency I, Emergency II, and Emergency III—which are more representative of the operating environment and protective equipment thresholds that firefighters should be aware of during firefighting operations and tactical decision-making.


  • Materials and Products Database Technical Reference Guide

    by Mark McKinnon, Craig Weinschenk, Daniel Madrzykowski

    For the past several years, the NIJ Technology Working Group’s Operational Requirements for Fire and Arson Investigation have included several scientific research needs that require improved knowledge of properties of materials that are common in the built environment, and therefore likely to be involved in a fire scene. The specific areas of research include: adequate materials data inputs for accurate computer models, understanding the effect of materials properties on the development and interpretation of fire patterns, and evaluation of incident heat flux profiles to walls and neighboring items in support of fire model validation. Each of the three aforementioned research topics rely, in part, on accurate knowledge of the physical conditions of a material prior to the fire, how the material will respond to the exposure of heat, and how it will perform once it has ignited. The project described herein has made advancements in terms of collecting experimental data and property information on a multitude of materials commonly encountered in the built environment for the purpose of making the data publicly available and easily accessible to fire investigators, fire protection engineers, and fire researchers.


  • Open Access

    Numerical Simulations of Gas Burner Experiments in a Residential Structure with HVAC System

    by Dushyant M. Chaudhari, Craig Weinschenk, Jason E. Floyd

    Controlled fire experiments using a gas burner were previously conducted in a purpose-built, two-story, moderately air-tight residential structure to understand the effect of a heating, ventilating, and air conditioning (HVAC) system and door positions on the fire-induced environment. Temperatures, gas concentrations (oxygen, water vapor, carbon dioxide), and differential pressures were monitored throughout the structure. HVAC status (off vs. on) and stairwell door position of the fire room (open vs. closed) were varied for the experiments analyzed in this paper. In this study, Fire Dynamics Simulator (FDS) v. 6.7.9 was used to simulate these experiments. Experimental data quantifying the air tightness of the building and cold flowrates through HVAC vents were determined to be important to optimize leakages and HVAC loss coefficients for the simulation setup. Pressure development in the structure was predicted correctly to be higher on the first floor and lower in the basement, but the magnitude of steady-state pressure was underpredicted. The measured and predicted steady-state temperature distributions were statistically different for the cases with and without the HVAC on, regardless of the door position. FDS predicted gas transport through the HVAC duct network, and under-predicted temperature rise and water vapor content by about 9% and 10%, respectively, and over-predicted volumetric oxygen and carbon dioxide content by about 21% and 6%, respectively. Temperature rise prediction in the closed room, where the gas transport primarily occurred via the HVAC duct network, improved after including heat loss from the HVAC duct to the ambient.


  • Open Access

    Experimental data from gas burner fires in residential structure with HVAC system

    by Craig Weinschenk, Shruti Ghanekar, Keith Stakes, Adam Quiat, Richard M. Kessler, Tonghun Lee


  • Analysis of Search and Rescue Tactics in Single-Story Single-Family Homes Part I: Bedroom Fires

    by Craig Weinschenk

    Prior full-scale fire service research on the residential fireground has focused the impact of ventilation and suppression tactics on fire dynamics. This study builds upon prior research by conducting 11 experiments a purpose-built single-story, single-family residential structure to quantify the im- pact of how search and rescue tactics are coupled with ventilation and suppression actions and timing. Each fully furnished structure included four bedrooms, 2 bathrooms and an open-floor kitchen and living room. The structures were instrumented to quantify post-ignition toxic gas and thermal conditions. Temperature, velocity, and pressure were measured to evaluate the fire dynamics. Gas concentrations and heat fluxes were measured to quantify toxic and thermal exposures. Across this series of experiments, the impact of isolation of fire and non-fire compartments, the timing of search actions relative to suppression actions, and the influence of isolation, elevation, and path of travel during rescue were examined with respect to firefighter safety and occupant tenability. Similar to previous experiments in both purpose-built and acquired structure, the data showed that prior intervention locations lower in elevation and/or behind closed doors had lower toxic gas and thermal exposures compared to locations at higher elevations or locations that were not isolated. Lower elevations were also shown to have lower toxic gas and thermal exposures during the removal of occupants as part of rescue operations. For scenarios where search operations occurred prior to suppression, isolation of spaces from flow paths connected to the fire compartment was shown to be effective at reducing the thermal operating class for firefighters and the toxic and thermal exposure rates compared to spaces that were not isolated. Following isolation, exterior ventilation was found to further reduce the toxic gas and thermal exposures in the protected space. Suppression, from either interior and exterior positions, was effective at reducing the thermal operating class for searching firefighters and the rate of thermal exposure increase to occupants. Following suppression, additional exterior ventilation increased the rate at which gas concentrations returned to pre-ignition levels.


  • Analysis of Search and Rescue Tactics in Single-Story Single-Family Homes Part II: Kitchen and Living Room Fires

    by Craig Weinschenk, Jack Regan

    Prior full-scale fire service research on the residential fireground has focused the impact of ventilation and suppression tactics on fire dynamics. This study builds upon prior research by conducting 10 experiments a purpose-built single-story, single-family residential structure to quantify the im- pact of how search and rescue tactics are coupled with ventilation and suppression actions and timing. Each fully furnished structure included four bedrooms, 2 bathrooms and an open-floor kitchen and living room. The structures were instrumented to quantify post-ignition toxic gas and thermal conditions. Temperature, velocity, and pressure were measured to evaluate the fire dynamics. Gas concentrations and heat fluxes were measured to quantify toxic and thermal exposures. Across this series of experiments, the impact of isolation of fire and non-fire compartments, the timing of search actions relative to suppression actions, and the influence of isolation, elevation, and path of travel during rescue were examined with respect to firefighter safety and occupant tenability. Similar to previous experiments in both purpose-built and acquired structure, the data showed that prior intervention locations lower in elevation and/or behind closed doors had lower toxic gas and thermal exposures compared to locations at higher elevations or locations that were not isolated. Lower elevations were also shown to have lower toxic gas and thermal exposures during the removal of occupants as part of rescue operations. For scenarios where search operations occurred prior to suppression, isolation of spaces from flow paths connected to the fire compartment was shown to be effective at reducing the thermal operating class for firefighters and the toxic and thermal exposure rates compared to spaces that were not isolated. Following isolation, exterior ventilation was found to further reduce the toxic gas and thermal exposures in the protected space. Suppression, from either interior and exterior positions, was effective at reducing the thermal operating class for searching firefighters and the rate of thermal exposure increase to occupants. Following suppression, additional exterior ventilation increased the rate at which gas concentrations returned to pre-ignition levels.


  • Analysis of Search and Rescue Tactics in Single-Story Single-Family Homes Part III: Tactical Considerations

    by Craig Weinschenk, Keith Stakes

    Prior full-scale fire service research on the residential fireground has focused the impact of ventilation and suppression tactics on fire dynamics. This study builds upon prior research by conducting 21 experiments in two identical purpose-built single-story, single-family residential structures to quantify the impact of how search and rescue tactics are coupled with ventilation and suppression actions and timing. Each fully furnished structure included four bedrooms, 2 bathrooms and an open-floor kitchen and living room. The structures were instrumented to quantify post-ignition toxic gas and thermal conditions. Temperature, velocity, and pressure were measured to evaluate the fire dynamics. Gas concentrations and heat fluxes were measured to quantify toxic and thermal exposures. Eleven experiments examined bedroom fires, eight examined kitchen fires, and two examined living room fires. Across this series of experiments, the impact of isolation of fire and non-fire compartments, the timing of search actions relative to suppression actions, and the influence of isolation, elevation, and path of travel during rescue were examined with respect to firefighter safety and occupant tenability. Similar to previous experiments in both purpose-built and acquired structure, the data showed that prior intervention locations lower in elevation and/or behind closed doors had lower toxic gas and thermal exposures compared to locations at higher elevations or locations that were not isolated. Lower elevations were also shown to have lower toxic gas and thermal exposures during the removal of occupants as part of rescue operations. For scenarios where search operations occurred prior to suppression, isolation of spaces from flow paths connected to the fire compartment was shown to be effective at reducing the thermal operating class for firefighters and the toxic and thermal exposure rates compared to spaces that were not isolated. Following isolation, exterior ventilation was found to further reduce the toxic gas and thermal exposures in the protected space. Suppression, from either interior and exterior positions, was effective at reducing the thermal operating class for searching firefighters and the rate of thermal exposure increase to occupants. Following suppression, additional exterior ventilation increased the rate at which gas concentrations returned to pre-ignition levels.