STShunta Togo

Shunta Togo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shunta Togo has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Landing-Induced Viscoelastic Changes in an Anthropomimetic Foot Joint Structure are Modulated by Foot Structure and Posture.

    by Satoru Hashimoto, Yinlai Jiang, Hiroshi Yokoi, Shunta Togo

    How skeletal architecture and landing posture shape the immediate post-impact viscoelastic response of the foot remains incompletely understood, in part because cadaveric specimens are ill-suited to repeated impact testing across postures. In this study, we developed an anthropomimetic foot joint structure aimed at replicating the skeletal geometry of the human foot. Using a vertical drop apparatus that simulates landing and a viscoelastic system-identification model, we investigated how skeletal structure and posture modulate the apparent post-impact viscoelastic response. The results show that the multi-jointed anthropomimetic structure exhibited a higher damping ratio than simplified flat and rigid feet. Moreover, ankle dorsiflexion and toe extension systematically shifted the identified parameters, reducing the damping ratio under the tested conditions. Taken together, these findings indicate that an arch-like, multi-jointed skeletal architecture can enhance impact attenuation in an anthropomimetic mechanical foot, and that morphology and passive posture alone can tune the trade-off between attenuation and rebound. The observed trends are qualitatively consistent with reported differences in human landing strategies, and highlight the engineering advantage of anatomically informed skeletal design for achieving tunable impact attenuation through postural adjustment.

  • Open Access

    Landing-Induced Viscoelastic Changes in an Anthropomimetic Foot Joint Structure are Modulated by Foot Structure and Posture

    by Satoru Hashimoto, Yinlai Jiang, Hiroshi Yokoi, Shunta Togo

    Cadaveric studies have provided important insights into the mechanics of the human foot arch and plantar fascia. However, repeatedly probing posture-dependent viscoelastic responses immediately after landing impact is difficult in biological specimens, leaving the contribution of skeletal architecture to landing dynamics incompletely understood. In this study, we developed an anthropomimetic foot joint structure aimed at replicating the skeletal geometry of the human foot. Using a vertical drop apparatus that simulates landing and a viscoelastic system-identification model, we investigated how skeletal structure and posture modulate the apparent post-impact viscoelastic response. The results show that the multi-jointed anthropomimetic structure exhibited a higher damping ratio than simplified flat and rigid feet. Moreover, ankle dorsiflexion and toe extension systematically shifted the identified parameters, reducing the damping ratio under the tested conditions. Taken together, these findings indicate that an arch-like, multi-jointed skeletal architecture can enhance impact attenuation in an anthropomimetic mechanical foot, and that morphology and passive posture alone can tune the trade-off between attenuation and rebound. The observed posture-dependent trends are qualitatively consistent with reported differences in human landing strategies, suggesting that skeletal architecture may partly account for the modulation. Furthermore, these results highlight the engineering advantage of anatomically informed skeletal replication for achieving human-like apparent viscoelastic behavior through postural adjustment during landing.

  • Open Access

    Repetitive Control of Robotic Joint With Variable Impedance Utilizing Agonist-Antagonist Muscle Pair Structure Based on Virtual Trajectories

    by Kaho Umeda, Yinlai Jiang, Hiroshi Yokoi, Shunta Togo

    Realizing accurate trajectory-tracking control for flexible robotic joints using a model-free approach is challenging. In this study, the repetitive control based on virtual trajectory, which is a model-free control method proposed for flexible human multi-joints, is extended and applied to a real robotic joint with a variable mechanical impedance mechanism. The virtual trajectory is modeled by a time series of the balanced position of the spring. In conventional methods, the virtual trajectory is corrected according to the trajectory error resulting from repetitive control. To achieve trajectory tracking even with a soft joint, this study proposes a strategy for starting repetitive control with a high joint impedance and switching to a lower joint impedance after convergence to the target trajectory, thereby successively correcting the estimated impedance change ratio by repetitive control. We developed a robotic joint with an agonist–antagonist muscle pair structure that can easily change its mechanical impedance using a position-controlled motor combined with a grommet, which changes its stiffness nonlinearly with respect to elongation, in addition to a wire traction mechanism as the control target. The results of simulations and real robot experiments demonstrated that the proposed method can achieve trajectory-tracking control even when the joint impedance is so low that the trajectory diverges from that of the conventional method. These results show that the proposed method is capable of trajectory tracking control while maintaining joint softness even when the dynamics of the control target and the impedance values before and after the change are unknown, that is, model-free.


  • A Robot Hand for Versatile Grasping With Tendon-Driven Telescopic Fingers

    by Yiwei Wang, Kazuma Kakino, Wenyang Li, Shunta Togo, Hiroshi Yokoi, Yinlai Jiang

    Service robots need robot hands that are versatile to grasp various objects while being lightweight to ensure robot mobility, minimize power consumption, and prioritize safety. In this paper, we propose a robot hand capable of adjusting the length of its fingers using a tendon-driven telescopic mechanism to accommodate objects of different sizes. The telescopic mechanism utilizes embedded wires to extend actively and an external silicone rubber glove to contract passively. The initial length of the fingers is set at 81.5 mm, with a maximum length of 141.5 mm, resulting in an elongation rate of 73.6%. The bending mechanism of the finger, which is independent from the telescopic mechanism, is realized with wires for active flexion and torsion springs for passive extension. Underactuated bending of the three finger joints is incorporated to conform to object shapes. The implemented robot hand with 3 fingers weighed only 230 g including 2 motors for telescopic extension and finger flexion. To evaluate the effectiveness of the telescopic robot hand, a two-way pull-out experiment was conducted using cylindrical objects of seven different sizes. The results demonstrated that adjusting finger length according to the objects improves grasping stability. The grasping experiments with daily objects indicated that the robot hand with telescopic fingers can stably grasp most of the objects used in daily life.


  • A Strain Gauge Based FMG Sensor for sEMG-FMG Dual Modal Measurement of Muscle Activity Associated with Hand Gestures

    by Yifan Tang, Jiayi Wang, Peiji Chen, Wenyang Li, Haokang Xu, Shunta Togo, Hiroshi Yokoi, Yinlai Jiang


  • Design of Anthropomimetic Robotic Wrist Joint and Forearm

    by Yoshinobu Obata, Yinlai Jiang, Hiroshi Yokoi, Shunta Togo

    In this study, we propose a design methodology for anthropomimetic robotic wrists and forearms. Conventional robotic wrists and forearms have few examples of human mimicry, and they have been simplified. The ligaments and tendons of the robotic forearm proposed in this study were replicated using chain-stitched wires and arranged in a manner similar to the human anatomy. Motion capture and goniometer measurements were used to measure the range of motion (ROM) of the wrist and forearm, driven by 16 servomotors. The results of the experiment were compared with the human ROM reported in previous studies, and it was found that the developed robotic forearm could achieve a ROM similar to that of humans. The use of this robotic forearm in functional verification experiments will enhance our understanding of the human structure. The integration of mechanical mechanisms with structures created through evolution is expected to improve the functionality of future robots.


  • Open Access

    A Layered sEMG–FMG Hybrid Sensor for Hand Motion Recognition From Forearm Muscle Activities

    by Peiji Chen, Ziye Li, Shunta Togo, Hiroshi Yokoi, Yinlai Jiang

    The activities of muscles in the forearm have been widely investigated to develop human interfaces involving hand motions, especially in the fields of prosthetic hands and teleoperation. Although surface electromyography (sEMG) is considered as an effective biological signal from which hand motions can be recognized, the availability and quality of sEMG data can limit the usability and intuitiveness of human interfaces. This article introduces force myography (FMG) as a supplementary signal and proposes a layered sEMG–FMG hybrid sensor that can measure both sEMG and FMG at the same skin surface location. Meanwhile, a layer fusion convolution neural network (LFC) is designed to extract multiscale features from sEMG and FMG. To evaluate the effectiveness of the hybrid sEMG–FMG sensor and LFC, a 22-hand motion classification experiment was conducted on nine able-bodied subjects. The recognition results indicated a significantly improved classification accuracy (p < 0.001) of the hybrid sEMG–FMG modality with respect to single sEMG or FMG modality. The classification accuracies (CAs) of LFC were compared with conventional machine learning methods, including support vector machine, random forest classifier, xgboost, and k-nearest neighbor. Compared with the single-modality sEMG, the CAs of the dual-modality sEMG–FMG using conventional methods, and LFC were improved by 21.31% and 16.71%, respectively. These results suggest that the layered sEMG–FMG sensing approach can effectively enhance the performance of human interfaces, which offers great potential in the clinical applications of sophisticated prosthetic hands and teleoperation.


  • Open Access

    Semi-Automated Control System for Reaching Movements in EMG Shoulder Disarticulation Prosthesis Based on Mixed Reality Device

    by Shunta Togo, Kazuaki Matsumoto, Susumu Kimizuka, Yinlai Jiang, Hiroshi Yokoi

    Goal: The development of a control system for an electromyographic shoulder disarticulation (EMG-SD) prosthesis to rapidly achieve a task with a reduction in the operational failure of the user. Methods: The motion planning of an EMG-SD prosthesis was automated using measured visual information through a mixed reality device. The detection of an object to be grasped and motion execution depended on the EMG of the user, which gives voluntary controllability and makes the system semi-automated. Two evaluation experiments with reaching and reach-to-grasp movements were conducted to compare the performance of the conventional system when operated using only visual feedback control of the user. Results: The proposed system can more rapidly and accurately achieve reaching movements (32% faster) and more accurate (69%) reach-to-grasp movements than a conventional system. Conclusions: The proposed control system achieves a high task performance with a reduction in the operational failure of an EMG-SD prosthesis user.


  • Development of a Humanoid Shoulder Based on 3-Motor 3 Degrees-of-Freedom Coupled Tendon-Driven Joint Module

    by Wenyang Li, Yiwei Wang, Shunta Togo, Hiroshi Yokoi, Yinlai Jiang

    In this study, a new humanoid shoulder is developed using a coupled tendon-driven mechanism that consists of three motors to drive three degrees of freedom (DoFs). In the coupled tendon-driven mechanism, multiple motors simultaneously drive multiple joints with each joint driven by at least two motors coupled with tendons. The torque of a motor is redistributed to multiple joints in a certain proportion to improve the load capacity of the joints. The 3M3D (3-motor 3-DoF) coupled tendon-driven joint module is systematically analyzed and divided into four categories according to the torque transmission characteristics between the motors and the joints: fully routed motor-joint form, 1-unrouted motor-joint form, 2-unrouted motor-joint form, and 3-unrouted motor-joint form. The four categories were analyzed and compared with respect to the characteristics of the motor torque redistribution with different tendon routing forms. The 2-unrouted motor-joint form was adopted for the development of the 3-DoF shoulder joint. The problem of the coexistence of coupling and non-coupling in one joint is solved by introducing a 2-DoF rolling joint. The relationship between the angle and torque between the motors and joints was verified experimentally. The experimental results revealed that the 3M3D coupled tendon-driven shoulder realized torque enhancement effectively by tendon coupling, and the angle accuracy was sufficient as a humanoid shoulder.


  • Open Access

    Development of a Two-Layered Elastic Glove for Dynamic Stable Grasping of Powered Prosthetic Hand

    by Yoshinobu Obata, Ayane Kumagai, Yoshiko Yabuki, Shunta Togo, Yinlai Jiang, Hiroshi Yokoi

    This study demonstrates that a bio-inspired fingertip structure improves the grasping performance of a prosthetic hand. A prosthetic hand attached to a human user requires a higher degree of grasping stability with minimal components compared to a typical robotic hand. Precision grasping tends to be less stable than power grasping; however, the former is used more frequently in daily life. To improve the stability of precision grasping, in this study, we focused on a two-layered elastic structure consisting of epidermis and subcutaneous tissue found in the finger. The efficiency of the two-layered structure, with respect to grasping stability, was evaluated by comparing one-layered and two-layered artificial fingertips. Finally, a two-layered elastic glove was designed based on the stability of the grasping. The stability of the precision grasping was evaluated using the pendulum experiment. The developed glove showed higher stability than the conventional prosthetic hand system.