Aldo José Fontes-Pereira
Research Subjects
Aldo José Fontes-Pereira has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Marco Antônio von Krüger
Biomedical Engineering Program, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
7 shared publications W. C. A. Pereira
Biomedical Eng. Program/COPPE, Federal University of Rio de Janeiro, Brazil
4 shared publicationsA. Schanaider
Departamento de Cirurgia, Escola de Medicina, Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brasil
3 shared publications- Wagner Coelho de Albuquerque Pereira
Biomedical Engineering Program - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
3 shared publications - Amauri Gouveia
Universidade Federal do Pará, Brasil
2 shared publications - Beatriz Maria Necy Gonçalves
Laboratório de Neurociências e Comportamento, Instituto de Ciências Biológicas, Universidade Federal do Pará, Rua Augusto Corrêa, 01, Campus básico, Guamá, CEP: 66075-110 Belém, PA, Brazil
2 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 39, e394924
Ultrasonic neuromodulation as a new therapy for spasticity in an animal model of spastic cerebral palsy
This study aimed to evaluate a new therapeutic option for the spasticity using ultrasound neuromodulation in an animal model of spastic cerebral palsy.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 39, e394924
Open AccessUltrasonic neuromodulation as a new therapy for spasticity in an animal model of spastic cerebral palsy
This study aimed to evaluate a new therapeutic option for the spasticity using ultrasound neuromodulation in an animal model of spastic cerebral palsy.
- Open Access
- 10 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 11963
Monitoring bone changes due to calcium, magnesium, and phosphorus loss in rat femurs using Quantitative Ultrasound
Bone mineral density is an important parameter for the diagnosis of bone diseases, as well as for predicting fractures and treatment monitoring. Thus, the aim of the present study was to evaluate the potential of Quantitative Ultrasound (QUS) to monitor bone changes after calcium, phosphorus, and magnesium loss in rat femurs in vitro during a demineralization process. Four quantitative ultrasound parameters were estimated from bone surface echoes in eight femur diaphysis of rats. The echo signals were acquired during a decalcification process by Ethylenediaminetetraacetic Acid (EDTA). The results were compared to Quantitative Computed Tomography (QCT) and inductively coupled plasma optical emission spectrometry measurements for validation. Integrated Reflection Coefficient (IRC) reflection parameters and Frequency Slope of Reflection Transfer Function (FSRTF) during demineralization tended to decrease, while the backscattering parameter Apparent Integrated Backscatter (AIB) increased and Frequency Slope of Apparent Backscatter (FSAB) showed an oscillatory behavior with no defined trend. Results indicate a clear relation between demineralization and the corresponding decrease in the reflection parameters and increase in the scattering parameters. The trend analysis of the fall curve of the chemical elements showed a better relationship between IRC and QCT. It was possible to monitor bone changes after ions losses, through the QUS. Thus, it is an indication that the proposed protocol has potential to characterize bone tissue in animal models, providing consistent results towards standardization of bone characterization studies by QUS endorsing its use in humans.
- 10 August 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 11963
Open AccessMonitoring bone changes due to calcium, magnesium, and phosphorus loss in rat femurs using Quantitative Ultrasound
Bone mineral density is an important parameter for the diagnosis of bone diseases, as well as for predicting fractures and treatment monitoring. Thus, the aim of the present study was to evaluate the potential of Quantitative Ultrasound (QUS) to monitor bone changes after calcium, phosphorus, and magnesium loss in rat femurs in vitro during a demineralization process. Four quantitative ultrasound parameters were estimated from bone surface echoes in eight femur diaphysis of rats. The echo signals were acquired during a decalcification process by Ethylenediaminetetraacetic Acid (EDTA). The results were compared to Quantitative Computed Tomography (QCT) and inductively coupled plasma optical emission spectrometry measurements for validation. Integrated Reflection Coefficient (IRC) reflection parameters and Frequency Slope of Reflection Transfer Function (FSRTF) during demineralization tended to decrease, while the backscattering parameter Apparent Integrated Backscatter (AIB) increased and Frequency Slope of Apparent Backscatter (FSAB) showed an oscillatory behavior with no defined trend. Results indicate a clear relation between demineralization and the corresponding decrease in the reflection parameters and increase in the scattering parameters. The trend analysis of the fall curve of the chemical elements showed a better relationship between IRC and QCT. It was possible to monitor bone changes after ions losses, through the QUS. Thus, it is an indication that the proposed protocol has potential to characterize bone tissue in animal models, providing consistent results towards standardization of bone characterization studies by QUS endorsing its use in humans.
- Open Access
- 1 August 2018
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 26 (4) , 255-259
EXPLORING CORTICAL BONE DENSITY THROUGH THE ULTRASOUND INTEGRATED REFLECTION COEFFICIENT
Objective: This work evaluates the relationship between ultrasonic reflection and bone density from fourteen cylindrical bovine cortical bone samples (3.0-cm thick). Methods: Twenty US reflection signals per sample were acquired along the bone surface (2.0-mm step). The Integrated Reflection Coefficient (IRC) from each signal was compared to Quantitative Computed Tomography (QCT). Results: Seven IRC and QCT curves presented Pearson's Correlation R-values above 0.5. For weak correlation curves, QCT and IRC showed similar trends in several segments. Conclusion: IRC was sensitive to bone density variation. Level of Evidence: Experimental Study, Investigating a Diagnostic Test.
- 1 August 2018
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 26 (4) , 255-259
Open AccessEXPLORING CORTICAL BONE DENSITY THROUGH THE ULTRASOUND INTEGRATED REFLECTION COEFFICIENT
Objective: This work evaluates the relationship between ultrasonic reflection and bone density from fourteen cylindrical bovine cortical bone samples (3.0-cm thick). Methods: Twenty US reflection signals per sample were acquired along the bone surface (2.0-mm step). The Integrated Reflection Coefficient (IRC) from each signal was compared to Quantitative Computed Tomography (QCT). Results: Seven IRC and QCT curves presented Pearson's Correlation R-values above 0.5. For weak correlation curves, QCT and IRC showed similar trends in several segments. Conclusion: IRC was sensitive to bone density variation. Level of Evidence: Experimental Study, Investigating a Diagnostic Test.
- Open Access
- 27 January 2017
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 5 (1) , 3
Why we should care about soft tissue interfaces when applying ultrasonic diathermy: an experimental and computer simulation study
One goal of therapeutic ultrasound is enabling heat generation in tissue. Ultrasound application protocols typically neglect these processes of absorption and backscatter/reflection at the skin/fat, fat/muscle, and muscle/bone interfaces. The aim of this study was to investigate the heating process at interfaces close to the transducer and the bone with the aid of computer simulation and tissue-mimicking materials (phantoms). The experimental setup consists of physiotherapeutic ultrasound equipment for irradiation, two layers of soft tissue-mimicking material, and one with and one without an additional layer of bone-mimicking material. Thermocouple monitoring is used in both cases. A computational model is used with the experimental parameters in a COMSOL® software platform. The experimental results show significant temperature rise (42 °C) at 10 mm depth, regardless of bone layer presence, diverging 3 °C from the simulated values. The probable causes are thermocouple and transducer heating and interface reverberations. There was no statistical difference in the experimental results with and without the cortical bone for the central thermocouple of the first interface [t(38) = −1.52; 95% CI = −0.85, 0.12; p = 14]. Temperature rise (>6 °C) close to the bone layer was lower than predicted (>21 °C), possibly because without the bone layer, thermocouples at 30 mm make contact with the water bath and convection intensifies heat loss; this factor was omitted in the simulation model. This work suggests that more attention should be given to soft tissue layer interfaces in ultrasound therapeutic procedures even in the absence of a close bone layer.
- 27 January 2017
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 5 (1) , 3
Open AccessWhy we should care about soft tissue interfaces when applying ultrasonic diathermy: an experimental and computer simulation study
One goal of therapeutic ultrasound is enabling heat generation in tissue. Ultrasound application protocols typically neglect these processes of absorption and backscatter/reflection at the skin/fat, fat/muscle, and muscle/bone interfaces. The aim of this study was to investigate the heating process at interfaces close to the transducer and the bone with the aid of computer simulation and tissue-mimicking materials (phantoms). The experimental setup consists of physiotherapeutic ultrasound equipment for irradiation, two layers of soft tissue-mimicking material, and one with and one without an additional layer of bone-mimicking material. Thermocouple monitoring is used in both cases. A computational model is used with the experimental parameters in a COMSOL® software platform. The experimental results show significant temperature rise (42 °C) at 10 mm depth, regardless of bone layer presence, diverging 3 °C from the simulated values. The probable causes are thermocouple and transducer heating and interface reverberations. There was no statistical difference in the experimental results with and without the cortical bone for the central thermocouple of the first interface [t(38) = −1.52; 95% CI = −0.85, 0.12; p = 14]. Temperature rise (>6 °C) close to the bone layer was lower than predicted (>21 °C), possibly because without the bone layer, thermocouples at 30 mm make contact with the water bath and convection intensifies heat loss; this factor was omitted in the simulation model. This work suggests that more attention should be given to soft tissue layer interfaces in ultrasound therapeutic procedures even in the absence of a close bone layer.
- Open Access
- 3 October 2016
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 4 (1) , 1-8
The influence of low-intensity physiotherapeutic ultrasound on the initial stage of bone healing in rats: an experimental and simulation study
Low-intensity physiotherapeutic ultrasound has been used in physical therapy clinics; however, there remain some scientific issues regarding the bone-healing process. The objective of this study was to investigate the influence of low-intensity physiotherapeutic ultrasound on the initial stage of bone healing in rats. Twenty-two male adult rats were assessed quantitatively and qualitatively using radiographic, biochemical, and histological analyses. Numerical simulations were also performed. Fractures in animals in the ultrasound group (n = 11) were treated with low-intensity ultrasound (pulsed mode, duty cycle 20 %) for 10 min daily at an intensity of 40 mW/cm2 SATA (1.0 MHz) for 10 days. Fractures in animals in the control group (n = 11) were not treated. Alkaline phosphatase levels were non-significantly higher in the ultrasound group than in the control group in the time intervals considered (t(13) = 0.440; 95 % confidence interval (CI) −13.79 to 20.82; p = 0.67). Between-group serum calcium levels were also not significantly different (t(13) = −0.842; 95 % CI −0.48 to 0.21; p = 0.42). Finally, there were no significant differences in radiological scores between the two groups (U = 118; 95 % CI −1.99 to 1.99; p = 0.72). However, the diameter of the newly formed bone tissue was greater and more evident in the ultrasound group. Thirteen days after fracture, there was no significant between-group differences in bone-healing processes, although the increased alkaline phosphatase levels and diameter of new bone tissue need to be further investigated.
- 3 October 2016
- Published by Springer Nature in Journal of Therapeutic Ultrasound
- Vol. 4 (1) , 1-8
Open AccessThe influence of low-intensity physiotherapeutic ultrasound on the initial stage of bone healing in rats: an experimental and simulation study
Low-intensity physiotherapeutic ultrasound has been used in physical therapy clinics; however, there remain some scientific issues regarding the bone-healing process. The objective of this study was to investigate the influence of low-intensity physiotherapeutic ultrasound on the initial stage of bone healing in rats. Twenty-two male adult rats were assessed quantitatively and qualitatively using radiographic, biochemical, and histological analyses. Numerical simulations were also performed. Fractures in animals in the ultrasound group (n = 11) were treated with low-intensity ultrasound (pulsed mode, duty cycle 20 %) for 10 min daily at an intensity of 40 mW/cm2 SATA (1.0 MHz) for 10 days. Fractures in animals in the control group (n = 11) were not treated. Alkaline phosphatase levels were non-significantly higher in the ultrasound group than in the control group in the time intervals considered (t(13) = 0.440; 95 % confidence interval (CI) −13.79 to 20.82; p = 0.67). Between-group serum calcium levels were also not significantly different (t(13) = −0.842; 95 % CI −0.48 to 0.21; p = 0.42). Finally, there were no significant differences in radiological scores between the two groups (U = 118; 95 % CI −1.99 to 1.99; p = 0.72). However, the diameter of the newly formed bone tissue was greater and more evident in the ultrasound group. Thirteen days after fracture, there was no significant between-group differences in bone-healing processes, although the increased alkaline phosphatase levels and diameter of new bone tissue need to be further investigated.
- 1 December 2015
- Published by Elsevier in Pharmacology Biochemistry and Behavior
- Vol. 139, 141-148
Reprint of "Pharmacological study of the light/dark preference test in zebrafish (Danio rerio): Waterborne administration"
- 1 December 2015
- Published by Elsevier in Pharmacology Biochemistry and Behavior
- Vol. 139, 141-148
Reprint of "Pharmacological study of the light/dark preference test in zebrafish (Danio rerio): Waterborne administration"
- 1 August 2015
- Published by Elsevier in Pharmacology Biochemistry and Behavior
- Vol. 135, 169-176
Pharmacological study of the light/dark preference test in zebrafish (Danio rerio): Waterborne administration
- 1 August 2015
- Published by Elsevier in Pharmacology Biochemistry and Behavior
- Vol. 135, 169-176
Pharmacological study of the light/dark preference test in zebrafish (Danio rerio): Waterborne administration
- Open Access
- 1 June 2014
- Published by FapUNIFESP (SciELO) in Fisioterapia em Movimento
- Vol. 27 (2) , 261-270
Balance, gait and quality of life in Parkinson's disease: Effects of whole body vibration treatment
Introduction Parkinson's disease (PD) is a neurodegenerative disorder, which triggers limitations and disability in people. Therefore, rehabilitation therapy is widely recommended in patients with PD, especially those who do not respond to pharmacological treatment.Objective Evaluate the effect of a protocol of Whole-body Vibration (WBV) in balance, gait and Quality of Life (QOL) of patients with PD, who do not respond to pharmacological treatment.Methods It was performed 12 sessions of a protocol WBV (squat, plantar flexion, isometric contraction of members and single-leg balance), with three sets each, at a vibrating platform (2mm and 35Hz) in 10 PD patients. By the first 3 sessions, patients underwent 20 seconds of exercise and 20 seconds of rest. After the third session, the treatment was 40 seconds of exercise and 20 seconds of rest. The Tinetti Test was applied before and after treatment to assess balance and gait, and the Parkinson's Disease Quality of Life-questionnaire (PDQL-BR), to evaluate the PDQL-BR and its subcategories: Parkinson, Systemic, Social and Emotional.Results Treatment did not significantly change the balance (p = 0.438), QOL issue in Emotional (p = 0.450) and Social (p = 0.171), but improved gait (p = 0.003), the Tinetti (p ≤ 0.001), the quality of life in items Parkinson (p ≤ 0.001), Systemic (p ≤ 0.001) and PDQL-BR (p ≤ 0.001).Conclusions WBV exercises on the vibrating platform, according to the parameters used, showed promising results that encourage its use to improve the clinical conditions related to disorders of gait, balance and QOL in patients with PD.
- 1 June 2014
- Published by FapUNIFESP (SciELO) in Fisioterapia em Movimento
- Vol. 27 (2) , 261-270
Open AccessBalance, gait and quality of life in Parkinson's disease: Effects of whole body vibration treatment
Introduction Parkinson's disease (PD) is a neurodegenerative disorder, which triggers limitations and disability in people. Therefore, rehabilitation therapy is widely recommended in patients with PD, especially those who do not respond to pharmacological treatment.Objective Evaluate the effect of a protocol of Whole-body Vibration (WBV) in balance, gait and Quality of Life (QOL) of patients with PD, who do not respond to pharmacological treatment.Methods It was performed 12 sessions of a protocol WBV (squat, plantar flexion, isometric contraction of members and single-leg balance), with three sets each, at a vibrating platform (2mm and 35Hz) in 10 PD patients. By the first 3 sessions, patients underwent 20 seconds of exercise and 20 seconds of rest. After the third session, the treatment was 40 seconds of exercise and 20 seconds of rest. The Tinetti Test was applied before and after treatment to assess balance and gait, and the Parkinson's Disease Quality of Life-questionnaire (PDQL-BR), to evaluate the PDQL-BR and its subcategories: Parkinson, Systemic, Social and Emotional.Results Treatment did not significantly change the balance (p = 0.438), QOL issue in Emotional (p = 0.450) and Social (p = 0.171), but improved gait (p = 0.003), the Tinetti (p ≤ 0.001), the quality of life in items Parkinson (p ≤ 0.001), Systemic (p ≤ 0.001) and PDQL-BR (p ≤ 0.001).Conclusions WBV exercises on the vibrating platform, according to the parameters used, showed promising results that encourage its use to improve the clinical conditions related to disorders of gait, balance and QOL in patients with PD.
- Open Access
- 4 April 2014
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 47 (5) , 403-410
Ultrasound method applied to characterize healthy femoral diaphysis of Wistar rats in vivo
A simple experimental protocol applying a quantitative ultrasound (QUS) pulse-echo technique was used to measure the acoustic parameters of healthy femoral diaphyses of Wistar rats in vivo. Five quantitative parameters [apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), time slope of apparent backscatter (TSAB), integrated reflection coefficient (IRC), and frequency slope of integrated reflection (FSIR)] were calculated using the echoes from cortical and trabecular bone in the femurs of 14 Wistar rats. Signal acquisition was performed three times in each rat, with the ultrasound signal acquired along the femur's central region from three positions 1 mm apart from each other. The parameters estimated for the three positions were averaged to represent the femur diaphysis. The results showed that AIB, FSAB, TSAB, and IRC values were statistically similar, but the FSIR values from Experiments 1 and 3 were different. Furthermore, Pearson's correlation coefficient showed, in general, strong correlations among the parameters. The proposed protocol and calculated parameters demonstrated the potential to characterize the femur diaphysis of rats in vivo. The results are relevant because rats have a bone structure very similar to humans, and thus are an important step toward preclinical trials and subsequent application of QUS in humans.
- 4 April 2014
- Published by FapUNIFESP (SciELO) in Brazilian Journal of Medical and Biological Research
- Vol. 47 (5) , 403-410
Open AccessUltrasound method applied to characterize healthy femoral diaphysis of Wistar rats in vivo
A simple experimental protocol applying a quantitative ultrasound (QUS) pulse-echo technique was used to measure the acoustic parameters of healthy femoral diaphyses of Wistar rats in vivo. Five quantitative parameters [apparent integrated backscatter (AIB), frequency slope of apparent backscatter (FSAB), time slope of apparent backscatter (TSAB), integrated reflection coefficient (IRC), and frequency slope of integrated reflection (FSIR)] were calculated using the echoes from cortical and trabecular bone in the femurs of 14 Wistar rats. Signal acquisition was performed three times in each rat, with the ultrasound signal acquired along the femur's central region from three positions 1 mm apart from each other. The parameters estimated for the three positions were averaged to represent the femur diaphysis. The results showed that AIB, FSAB, TSAB, and IRC values were statistically similar, but the FSIR values from Experiments 1 and 3 were different. Furthermore, Pearson's correlation coefficient showed, in general, strong correlations among the parameters. The proposed protocol and calculated parameters demonstrated the potential to characterize the femur diaphysis of rats in vivo. The results are relevant because rats have a bone structure very similar to humans, and thus are an important step toward preclinical trials and subsequent application of QUS in humans.
- 1 May 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 133 (5_Suppleme) , 3585
Computational simulations of time of flight and attenuation of first arriving signal from healing process of diaphyseal femur fractures
Quantitative ultrasound (QUS) has been proposed to evaluate structural conditions from bone tissue in a non-invasive way. These techniques are based on the fact that the ultrasound propagation depends directly of tissues structures, so they carry information about them. Based on these arguments, the aim of this work was to estimate the time-of-flight (TOF) and attenuation of the first arriving signal (FAS) using computational simulations (Wave2000® CyberLogic, Inc., NY, EUA) in an axial transmission model in different kinds of fracture, during the healing process. In this work, we used QUS techniques to analyze the fracture healing process. The FAS has been chosen because it does not suffer interference of other waves since it is the first signal to arrive at the receiver. TOF increases immediately after bone fracture. When bone tissue starts to consolidate, TOF decreases and stabilizes with the same value of the intact bone. Attenuation is bigger in oblique and spiculate fracture than transversal ones for the same stage, which suggests that attenuation is sensitive to the kind of fracture. Other studies are being conducted to clarify this point.
- 1 May 2013
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 133 (5_Suppleme) , 3585
Computational simulations of time of flight and attenuation of first arriving signal from healing process of diaphyseal femur fractures
Quantitative ultrasound (QUS) has been proposed to evaluate structural conditions from bone tissue in a non-invasive way. These techniques are based on the fact that the ultrasound propagation depends directly of tissues structures, so they carry information about them. Based on these arguments, the aim of this work was to estimate the time-of-flight (TOF) and attenuation of the first arriving signal (FAS) using computational simulations (Wave2000® CyberLogic, Inc., NY, EUA) in an axial transmission model in different kinds of fracture, during the healing process. In this work, we used QUS techniques to analyze the fracture healing process. The FAS has been chosen because it does not suffer interference of other waves since it is the first signal to arrive at the receiver. TOF increases immediately after bone fracture. When bone tissue starts to consolidate, TOF decreases and stabilizes with the same value of the intact bone. Attenuation is bigger in oblique and spiculate fracture than transversal ones for the same stage, which suggests that attenuation is sensitive to the kind of fracture. Other studies are being conducted to clarify this point.