Marco Antônio von Krüger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marco Antônio von Krüger has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
W. C. A. Pereira
Biomedical Engineering Program, Federal University of Rio de Janeiro, Brazil
16 shared publications- Aldo José Fontes-Pereira
Ultrasound Laboratory, Biomedical Engineering Program/COPPE/Federal University of Rio de Janeiro - UFRJ, Rio de Janeiro, Rio de Janeiro Brazil
7 shared publications - Wagner Coelho de Albuquerque Pereira
Biomedical Engineering Program - COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil
7 shared publications - José Francisco Silva Costa-Júnior
Brazilian Air Force Academy, Pirassununga, Brazil
6 shared publications W.C.A. Pereira
6 shared publications- Guillermo Cortela
Universidad de la República
5 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 39, e394924
Ultrasonic neuromodulation as a new therapy for spasticity in an animal model of spastic cerebral palsy
This study aimed to evaluate a new therapeutic option for the spasticity using ultrasound neuromodulation in an animal model of spastic cerebral palsy.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Acta Cirurgica Brasileira
- Vol. 39, e394924
Open AccessUltrasonic neuromodulation as a new therapy for spasticity in an animal model of spastic cerebral palsy
This study aimed to evaluate a new therapeutic option for the spasticity using ultrasound neuromodulation in an animal model of spastic cerebral palsy.
- 11 August 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (5) , 055017
Recycled windshield glass as new material for producing ultrasonic phantoms of cortical bone-healing stages
The quantitative ultrasound technique was used to evaluate bone-mimicking phantoms; however, these phantoms do not mimic the intermediate stages of cortical bone healing. We propose using windshield glass as an original material to produce phantoms that mimic the characteristics of three different stages of cortical bone healing. This material was processed via a route that included breaking, grinding, compacting, drying, and sintering in four temperature groups: 625 °C, 645 °C, 657 °C, and 663 °C. The parameters evaluated were the ultrasonic longitudinal phase velocity ( c L ), corrected ( α c ) ultrasonic attenuation coefficient, and bulk density ( ρ s ). The results showed that the mean values of c L , α c , and ρ s varied from 2, 398 to 4, 406 m·s −1 , 3 to 10 dB·cm −1 , and 1, 563 to 2, 089 kg·m −3 , respectively. The phantoms exhibited properties comparable with the three stages of cortical bone healing and can be employed in diagnostic and therapeutic studies using ultrasound.
- 11 August 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (5) , 055017
Recycled windshield glass as new material for producing ultrasonic phantoms of cortical bone-healing stages
The quantitative ultrasound technique was used to evaluate bone-mimicking phantoms; however, these phantoms do not mimic the intermediate stages of cortical bone healing. We propose using windshield glass as an original material to produce phantoms that mimic the characteristics of three different stages of cortical bone healing. This material was processed via a route that included breaking, grinding, compacting, drying, and sintering in four temperature groups: 625 °C, 645 °C, 657 °C, and 663 °C. The parameters evaluated were the ultrasonic longitudinal phase velocity ( c L ), corrected ( α c ) ultrasonic attenuation coefficient, and bulk density ( ρ s ). The results showed that the mean values of c L , α c , and ρ s varied from 2, 398 to 4, 406 m·s −1 , 3 to 10 dB·cm −1 , and 1, 563 to 2, 089 kg·m −3 , respectively. The phantoms exhibited properties comparable with the three stages of cortical bone healing and can be employed in diagnostic and therapeutic studies using ultrasound.
- 15 January 2020
- Published by Wiley in Skin Research and Technology
- Vol. 26 (4) , 465-475
Using high‐resolution ultrasound imaging to characterize dermal striae in human skin
Background and Objective: The improvement in the appearance of the skin with dermal striae (DS) is currently eval‐uated by invasive methods, such as biopsy. This study evaluates whether high‐resolution ultrasound (HRUS) could be used to identify skin lesions in vivo caused by DS, using 2D images and measuring the thickness of the dermal layer.Methods: High‐resolution ultrasound at frequencies of 20 and 30 MHz was used in this study in ten volunteers with DS. The thickness of the skin layers was estimated by tracing five vertical lines from epidermis (EP) to dermis (DE) and DE to hypodermis (H) surface.Results: The dermal lesions caused by striae appeared in ultrasonic images as poor echo areas. The average normal DE thickness varied from 1.07 to 1.65 mm, while the DE thickness with DS varied between 0.35 and 1.33 mm. A statistically significant reduction in the DE thickness was found (P‐value < .05) in the presence of DS. The mean values of the EP thickness without and with DS were 0.12 ± 0.03 mm and 0.11 ± 0.02 mm, respec‐tively. A total of 90.00% of the EP‐related groups did not present the normal distribu‐tion (P‐value < .05).Conclusions: High‐resolution ultrasound permitted the visualization of the three skin layers and the dermal lesions caused by striae. The dermal layer thicknesses with striae were thinner than those without. Therefore, ultrasound 2D imaging has shown to be a promising and financially feasible tool to be used as a noninvasive diagnostic method for evaluating therapeutic protocols used in the treatment of these dermal conditions.
- 15 January 2020
- Published by Wiley in Skin Research and Technology
- Vol. 26 (4) , 465-475
Using high‐resolution ultrasound imaging to characterize dermal striae in human skin
Background and Objective: The improvement in the appearance of the skin with dermal striae (DS) is currently eval‐uated by invasive methods, such as biopsy. This study evaluates whether high‐resolution ultrasound (HRUS) could be used to identify skin lesions in vivo caused by DS, using 2D images and measuring the thickness of the dermal layer.Methods: High‐resolution ultrasound at frequencies of 20 and 30 MHz was used in this study in ten volunteers with DS. The thickness of the skin layers was estimated by tracing five vertical lines from epidermis (EP) to dermis (DE) and DE to hypodermis (H) surface.Results: The dermal lesions caused by striae appeared in ultrasonic images as poor echo areas. The average normal DE thickness varied from 1.07 to 1.65 mm, while the DE thickness with DS varied between 0.35 and 1.33 mm. A statistically significant reduction in the DE thickness was found (P‐value < .05) in the presence of DS. The mean values of the EP thickness without and with DS were 0.12 ± 0.03 mm and 0.11 ± 0.02 mm, respec‐tively. A total of 90.00% of the EP‐related groups did not present the normal distribu‐tion (P‐value < .05).Conclusions: High‐resolution ultrasound permitted the visualization of the three skin layers and the dermal lesions caused by striae. The dermal layer thicknesses with striae were thinner than those without. Therefore, ultrasound 2D imaging has shown to be a promising and financially feasible tool to be used as a noninvasive diagnostic method for evaluating therapeutic protocols used in the treatment of these dermal conditions.
- 16 May 2019
- Published by Springer Nature
- p. 831-836
Lung Ultrasonography Phantom for Lung-Pulse Sign Simulation
- 16 May 2019
- Published by Springer Nature
- p. 831-836
Lung Ultrasonography Phantom for Lung-Pulse Sign Simulation
- 16 May 2019
- Published by Springer Nature
- p. 765-770
Characterization of Acoustic Properties of Poly(Acrylic Acid) Solution and Gel for Confection of Ultrasonic Phantoms
- 16 May 2019
- Published by Springer Nature
- p. 765-770
Characterization of Acoustic Properties of Poly(Acrylic Acid) Solution and Gel for Confection of Ultrasonic Phantoms
- Open Access
- 1 August 2018
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 26 (4) , 255-259
EXPLORING CORTICAL BONE DENSITY THROUGH THE ULTRASOUND INTEGRATED REFLECTION COEFFICIENT
Objective: This work evaluates the relationship between ultrasonic reflection and bone density from fourteen cylindrical bovine cortical bone samples (3.0-cm thick). Methods: Twenty US reflection signals per sample were acquired along the bone surface (2.0-mm step). The Integrated Reflection Coefficient (IRC) from each signal was compared to Quantitative Computed Tomography (QCT). Results: Seven IRC and QCT curves presented Pearson's Correlation R-values above 0.5. For weak correlation curves, QCT and IRC showed similar trends in several segments. Conclusion: IRC was sensitive to bone density variation. Level of Evidence: Experimental Study, Investigating a Diagnostic Test.
- 1 August 2018
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 26 (4) , 255-259
Open AccessEXPLORING CORTICAL BONE DENSITY THROUGH THE ULTRASOUND INTEGRATED REFLECTION COEFFICIENT
Objective: This work evaluates the relationship between ultrasonic reflection and bone density from fourteen cylindrical bovine cortical bone samples (3.0-cm thick). Methods: Twenty US reflection signals per sample were acquired along the bone surface (2.0-mm step). The Integrated Reflection Coefficient (IRC) from each signal was compared to Quantitative Computed Tomography (QCT). Results: Seven IRC and QCT curves presented Pearson's Correlation R-values above 0.5. For weak correlation curves, QCT and IRC showed similar trends in several segments. Conclusion: IRC was sensitive to bone density variation. Level of Evidence: Experimental Study, Investigating a Diagnostic Test.
- Open Access
- 27 March 2017
- Published by FapUNIFESP (SciELO) in Research on Biomedical Engineering
- Vol. 33 (1) , 42-49
Evaluation of gloves as a water bag coupling agent for therapeutic ultrasound
Keywords Therapeutic ultrasound; Water bag technique; Acoustic power
- 27 March 2017
- Published by FapUNIFESP (SciELO) in Research on Biomedical Engineering
- Vol. 33 (1) , 42-49
Open AccessEvaluation of gloves as a water bag coupling agent for therapeutic ultrasound
Keywords Therapeutic ultrasound; Water bag technique; Acoustic power
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Building up lesion-like phantoms for mimicking breast ultrasound images
Breast ultrasound is an important complement to mammography that allows differentiating between benign and malignant lesions. The early diagnosis and specialized care for women with breast cancer are indispensable for a better therapeutic result and prognosis of cases. Thereby, it is necessary training professionals to emit trustworthy diagnoses. Here, we set up lesions-like structures in a plasticized polyvinyl chloride phantom. We classified lesions according to their internal echoes and later items. Correlations between the composition of the phantoms and their respective effects at B-mode images become evident. Encapsulated lesions with low internal attenuation materials, were similar to benign lesions having regular and well-defined contours, oval or circular shape, well defined posterior wall and the presence of the acoustic reinforcement, while unencapsulated lesions with high attenuation materials were similar to malignant lesions having an irregular contour and edge shadow.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Building up lesion-like phantoms for mimicking breast ultrasound images
Breast ultrasound is an important complement to mammography that allows differentiating between benign and malignant lesions. The early diagnosis and specialized care for women with breast cancer are indispensable for a better therapeutic result and prognosis of cases. Thereby, it is necessary training professionals to emit trustworthy diagnoses. Here, we set up lesions-like structures in a plasticized polyvinyl chloride phantom. We classified lesions according to their internal echoes and later items. Correlations between the composition of the phantoms and their respective effects at B-mode images become evident. Encapsulated lesions with low internal attenuation materials, were similar to benign lesions having regular and well-defined contours, oval or circular shape, well defined posterior wall and the presence of the acoustic reinforcement, while unencapsulated lesions with high attenuation materials were similar to malignant lesions having an irregular contour and edge shadow.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Comparison of two ultrasonic phantom manufacturing protocols made of polyvinyl chloride Plastisol
Ultrasonography is an important and well-accepted technique, once it is noninvasive and capable of giving complementary information that helps the radiologist classifying lesions. Consequently, it is worthy to invest in the design and production of phantoms to provide support to controlled experiments as well as help training health professionals, and Computer Aided-Diagnoses systems. However, there is a need in the literature for a standardised protocol that helps further comparison studies. In this study, two ultrasonic phantoms were constructed to mimic soft tissue. The material used in these phantoms is the polyvinyl chloride plastisol - PVCP, a well-known material used in other areas. The protocols differ at its heating tools: Electric and microwave stove. Eight phantoms for each protocol were made, and their respective ultrasound propagation speed and attenuation coefficients were compared, showing a statistical difference between speeds but no difference in attenuation. The two manufacturing protocols demonstrated to be useful for phantom confection with no significant changes in acoustics properties. This paper is a valuable tool at the demand for protocols standardisation.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Comparison of two ultrasonic phantom manufacturing protocols made of polyvinyl chloride Plastisol
Ultrasonography is an important and well-accepted technique, once it is noninvasive and capable of giving complementary information that helps the radiologist classifying lesions. Consequently, it is worthy to invest in the design and production of phantoms to provide support to controlled experiments as well as help training health professionals, and Computer Aided-Diagnoses systems. However, there is a need in the literature for a standardised protocol that helps further comparison studies. In this study, two ultrasonic phantoms were constructed to mimic soft tissue. The material used in these phantoms is the polyvinyl chloride plastisol - PVCP, a well-known material used in other areas. The protocols differ at its heating tools: Electric and microwave stove. Eight phantoms for each protocol were made, and their respective ultrasound propagation speed and attenuation coefficients were compared, showing a statistical difference between speeds but no difference in attenuation. The two manufacturing protocols demonstrated to be useful for phantom confection with no significant changes in acoustics properties. This paper is a valuable tool at the demand for protocols standardisation.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Linear relationship between the Effective Radiation Area and thermal images on thermochromic test body for the purpose of dosimetry quality control
Five 3-MHz Therapeutic Ultrasonic (TUS) devices with their respective transducers were employed to study the relationship between the transducer Effective Radiation Area (ERA) and the area of the thermal image generated by irradiating a thermochromic test body. The resulting relationship was linear, in agreement with previous work.
- 1 March 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Linear relationship between the Effective Radiation Area and thermal images on thermochromic test body for the purpose of dosimetry quality control
Five 3-MHz Therapeutic Ultrasonic (TUS) devices with their respective transducers were employed to study the relationship between the transducer Effective Radiation Area (ERA) and the area of the thermal image generated by irradiating a thermochromic test body. The resulting relationship was linear, in agreement with previous work.