Hossein Aslian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hossein Aslian has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Mara Severgnini
Department of Medical Physics, Azienda Sanitaria Universitaria Integrata di Trieste, Trieste, Italy
4 shared publications Mehdi Astaraki
Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Sweden
4 shared publicationsFrancesco Longo
Department of Physics University of Trieste Trieste Italy
2 shared publications- Francesco Longo
Università di Trieste
2 shared publications Mahyar Hamedi
Centre for Biomedical Engineering, Universiti Teknologi Malaysia, Skudai, Malaysia
2 shared publicationsMara Severgnini
Department of Medical Physics, Azienda Sanitaria Universitaria Integrata di Trieste, Trieste, Italy
2 shared publications
Latest Publications
- 1 October 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 176, 109895
Neutron and photon out-of-field doses at cardiac implantable electronic device (CIED) depths
- 1 October 2021
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 176, 109895
Neutron and photon out-of-field doses at cardiac implantable electronic device (CIED) depths
- Open Access
- 11 April 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (6) , 121-131
The effect of stereotactic body radiotherapy (SBRT) using flattening filter‐free beams on cardiac implantable electronic devices (CIEDs) in clinical situations
Purpose: This study focused on determining risks from stereotactic radiotherapy using flattening filter‐free (FFF) beams for patients with cardiac implantable electronic device (CIEDs). Two strategies were employed: a) a retrospective analysis of patients with CIEDs who underwent stereotactic radiosurgery (SRS)/SBRT at the Peter MacCallum Cancer Centre between 2014 and 2018 and b) an experimental study on the impact of FFF beams on CIEDs.Methods: A retrospective review was performed. Subsequently, a phantom study was performed using 30 fully functional explanted CIEDs from two different manufacturers. Irradiation was carried out in a slab phantom with 6‐MV and 10‐MV FFF beams. First, a repetition‐rate test (RRT) with a range of beam pulse frequencies was conducted. Then, multifraction SBRT (48 Gy/4 Fx) and single‐fraction SBRT (28 Gy/1 Fx) treatment plans were used for lung tumors delivered to the phantom.Results: Between 2014 and 2018, 13 cases were treated with an FFF beam (6 MV, 1400 MU/min or 10 MV, 2400 MU/min), and 15 cases were treated with a flattening filter (FF) beam (6 MV, 600 MU/min). All the devices were positioned outside the treatment field at a distance of more than 5 cm, except for one case, and no failures were reported due to SBRT/SRS. In the phantom rep‐rate tests, inappropriate sensing occurred, starting at a rep‐rate of 1200 MU/min. Cardiac implantable electronic device anomalies during and after delivering VMAT‐SBRT with a 10‐MV FFF beam were observed.Conclusions: The study showed that caution should be paid to managing CIED patients when they undergo SBRT using FFF beams, as it is recommended by AAPM TG‐203. Correspondingly, it was found that for FFF beams although there is small risk from dose‐rate effects, delivering high dose of radiation with beam energy greater than 6 MV and high‐dose rate to CIEDs positioned in close vicinity of the PTV may present issues.
- 11 April 2020
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (6) , 121-131
Open AccessThe effect of stereotactic body radiotherapy (SBRT) using flattening filter‐free beams on cardiac implantable electronic devices (CIEDs) in clinical situations
Purpose: This study focused on determining risks from stereotactic radiotherapy using flattening filter‐free (FFF) beams for patients with cardiac implantable electronic device (CIEDs). Two strategies were employed: a) a retrospective analysis of patients with CIEDs who underwent stereotactic radiosurgery (SRS)/SBRT at the Peter MacCallum Cancer Centre between 2014 and 2018 and b) an experimental study on the impact of FFF beams on CIEDs.Methods: A retrospective review was performed. Subsequently, a phantom study was performed using 30 fully functional explanted CIEDs from two different manufacturers. Irradiation was carried out in a slab phantom with 6‐MV and 10‐MV FFF beams. First, a repetition‐rate test (RRT) with a range of beam pulse frequencies was conducted. Then, multifraction SBRT (48 Gy/4 Fx) and single‐fraction SBRT (28 Gy/1 Fx) treatment plans were used for lung tumors delivered to the phantom.Results: Between 2014 and 2018, 13 cases were treated with an FFF beam (6 MV, 1400 MU/min or 10 MV, 2400 MU/min), and 15 cases were treated with a flattening filter (FF) beam (6 MV, 600 MU/min). All the devices were positioned outside the treatment field at a distance of more than 5 cm, except for one case, and no failures were reported due to SBRT/SRS. In the phantom rep‐rate tests, inappropriate sensing occurred, starting at a rep‐rate of 1200 MU/min. Cardiac implantable electronic device anomalies during and after delivering VMAT‐SBRT with a 10‐MV FFF beam were observed.Conclusions: The study showed that caution should be paid to managing CIED patients when they undergo SBRT using FFF beams, as it is recommended by AAPM TG‐203. Correspondingly, it was found that for FFF beams although there is small risk from dose‐rate effects, delivering high dose of radiation with beam energy greater than 6 MV and high‐dose rate to CIEDs positioned in close vicinity of the PTV may present issues.
- 4 April 2019
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 42 (2) , 415-425
A review and analysis of stereotactic body radiotherapy and radiosurgery of patients with cardiac implantable electronic devices
The implementation of stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) has greatly increased due to its convenience and advantages from perspectives ranging from radiobiology to radio physics. Because SBRT/SRS delivers high doses in few fractions, precise dose delivery to target volumes and sufficient sparing of adjacent organs at risk (OARs) are required. Achieving these conflicting objectives is challenging for all patients receiving SBRT/SRS and may be particularly challenging when SBRT/SRS is adopted for treating patients with cardiac implantable electronic devices (CIEDs) because cumulative doses in CIEDs must be limited. Published research considering the different aspects of stereotactic treatment in patients with CIEDs was reviewed to summarise their findings in the following sections: (I) conventional linear accelerator (linac)-based SBRT and SRS; (II) CyberKnife, Gamma-Knife, VERO and helical tomotherapy SBRT and SRS; and (III) proton therapy. A total of 65 patients who had CIEDs and underwent SRS, SBRT, or SABR treatments were identified in the reviewed studies. The functionality of the CIEDs was assessed for 58 patients. Of those, CIED malfunctions (such as data loss, mode change, and inappropriate shock) were reported in four patients (6.89%). This review highlights the available sparse information in the literature by posing questions for future research.
- 4 April 2019
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 42 (2) , 415-425
A review and analysis of stereotactic body radiotherapy and radiosurgery of patients with cardiac implantable electronic devices
The implementation of stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) has greatly increased due to its convenience and advantages from perspectives ranging from radiobiology to radio physics. Because SBRT/SRS delivers high doses in few fractions, precise dose delivery to target volumes and sufficient sparing of adjacent organs at risk (OARs) are required. Achieving these conflicting objectives is challenging for all patients receiving SBRT/SRS and may be particularly challenging when SBRT/SRS is adopted for treating patients with cardiac implantable electronic devices (CIEDs) because cumulative doses in CIEDs must be limited. Published research considering the different aspects of stereotactic treatment in patients with CIEDs was reviewed to summarise their findings in the following sections: (I) conventional linear accelerator (linac)-based SBRT and SRS; (II) CyberKnife, Gamma-Knife, VERO and helical tomotherapy SBRT and SRS; and (III) proton therapy. A total of 65 patients who had CIEDs and underwent SRS, SBRT, or SABR treatments were identified in the reviewed studies. The functionality of the CIEDs was assessed for 58 patients. Of those, CIED malfunctions (such as data loss, mode change, and inappropriate shock) were reported in four patients (6.89%). This review highlights the available sparse information in the literature by posing questions for future research.
- 1 November 2018
- Published by Elsevier in Physica Medica
- Vol. 55, 40-46
A multicenter dosimetry study to evaluate the imaging dose from Elekta XVI and Varian OBI kV-CBCT systems to cardiovascular implantable electronic devices (CIEDs)
- 1 November 2018
- Published by Elsevier in Physica Medica
- Vol. 55, 40-46
A multicenter dosimetry study to evaluate the imaging dose from Elekta XVI and Varian OBI kV-CBCT systems to cardiovascular implantable electronic devices (CIEDs)
- Open Access
- 30 May 2018
- Published by Springer Nature
- p. 873-876
Evaluation of the Impact of an International Master of Advanced Studies in Medical Physics
The Master of advanced studies in Medical Physics (MMP) has been jointly organized since 2014 by the International Centre for Theoretical Physics (ICTP) and Trieste University and supported by the International Atomic Energy Agency (IAEA), through the work of the Dosimetry and Medical Radiation Physics Section (DMRP), Division of Human Health (NAHU) and the IAEA Technical Cooperation Programme. The MMP, offers one academic year of theoretical classes followed by one year of structured clinical training in hospitals. It aims at addressing the scarcity of formal education and training schemes for medical physics studies, through an internationally harmonized programme that provides graduates with an academic knowledge and practical skills and competencies, to effectively practice medical physics once back to their home countries and Regions. Adequate academic education and structured clinical training of medical physicists play an important role in ensuring the safe and effective use of nuclear technologies in the diagnosis and treatment of patients. To evaluate the impact of the MMP, an online survey was developed and distributed to the graduates of the first two cycles of the programme, in March 2017, considering different aspects contributing to the overall fulfilment of the MMP aims. Criteria comprised: the activity of the graduates before and after the MMP, return rate to their home country and work activities performed after the degree. Specific feedback was also analysed about the MMP programme. The analysis of the 22 received answers (85% of all graduates at the time of the survey) is presented in this article.
- 30 May 2018
- Published by Springer Nature
- p. 873-876
Open AccessEvaluation of the Impact of an International Master of Advanced Studies in Medical Physics
The Master of advanced studies in Medical Physics (MMP) has been jointly organized since 2014 by the International Centre for Theoretical Physics (ICTP) and Trieste University and supported by the International Atomic Energy Agency (IAEA), through the work of the Dosimetry and Medical Radiation Physics Section (DMRP), Division of Human Health (NAHU) and the IAEA Technical Cooperation Programme. The MMP, offers one academic year of theoretical classes followed by one year of structured clinical training in hospitals. It aims at addressing the scarcity of formal education and training schemes for medical physics studies, through an internationally harmonized programme that provides graduates with an academic knowledge and practical skills and competencies, to effectively practice medical physics once back to their home countries and Regions. Adequate academic education and structured clinical training of medical physicists play an important role in ensuring the safe and effective use of nuclear technologies in the diagnosis and treatment of patients. To evaluate the impact of the MMP, an online survey was developed and distributed to the graduates of the first two cycles of the programme, in March 2017, considering different aspects contributing to the overall fulfilment of the MMP aims. Criteria comprised: the activity of the graduates before and after the MMP, return rate to their home country and work activities performed after the degree. Specific feedback was also analysed about the MMP programme. The analysis of the 22 received answers (85% of all graduates at the time of the survey) is presented in this article.
- Open Access
- 1 January 2018
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 5, 52-57
Evaluation of localized region-based segmentation algorithms for CT-based delineation of organs at risk in radiotherapy
- 1 January 2018
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 5, 52-57
Open AccessEvaluation of localized region-based segmentation algorithms for CT-based delineation of organs at risk in radiotherapy
- 1 January 2017
- Published by Wolters Kluwer Health in Journal of Cancer Research and Therapeutics
- Vol. 13 (1) , 69-79
Tabulated square-shaped source model for linear accelerator electron beam simulation
Context: Using this source model, the Monte Carlo (MC) computation becomes much faster for electron beams. Aims: The aim of this study was to present a source model that makes linear accelerator (LINAC) electron beam geometry simulation less complex. Settings and Design: In this study, a tabulated square-shaped source with transversal and axial distribution biasing and semi-Gaussian spectrum was investigated. Subjects and Methods: A low energy photon spectrum was added to the semi-Gaussian beam to correct the bremsstrahlung X-ray contamination. After running the MC code multiple times and optimizing all spectrums for four electron energies in three different medical LINACs (Elekta, Siemens, and Varian), the characteristics of a beam passing through a 10 cm × 10 cm applicator were obtained. The percentage depth dose and dose profiles at two different depths were measured and simulated. Results: The maximum difference between simulated and measured percentage of depth doses and dose profiles was 1.8% and 4%, respectively. The low energy electron and photon spectrum and the Gaussian spectrum peak energy and associated full width at half of maximum and transversal distribution weightings were obtained for each electron beam. The proposed method yielded a maximum computation time 702 times faster than a complete head simulation. Conclusions: Our study demonstrates that there was an excellent agreement between the results of our proposed model and measured data; furthermore, an optimum calculation speed was achieved because there was no need to define geometry and materials in the LINAC head.
- 1 January 2017
- Published by Wolters Kluwer Health in Journal of Cancer Research and Therapeutics
- Vol. 13 (1) , 69-79
Tabulated square-shaped source model for linear accelerator electron beam simulation
Context: Using this source model, the Monte Carlo (MC) computation becomes much faster for electron beams. Aims: The aim of this study was to present a source model that makes linear accelerator (LINAC) electron beam geometry simulation less complex. Settings and Design: In this study, a tabulated square-shaped source with transversal and axial distribution biasing and semi-Gaussian spectrum was investigated. Subjects and Methods: A low energy photon spectrum was added to the semi-Gaussian beam to correct the bremsstrahlung X-ray contamination. After running the MC code multiple times and optimizing all spectrums for four electron energies in three different medical LINACs (Elekta, Siemens, and Varian), the characteristics of a beam passing through a 10 cm × 10 cm applicator were obtained. The percentage depth dose and dose profiles at two different depths were measured and simulated. Results: The maximum difference between simulated and measured percentage of depth doses and dose profiles was 1.8% and 4%, respectively. The low energy electron and photon spectrum and the Gaussian spectrum peak energy and associated full width at half of maximum and transversal distribution weightings were obtained for each electron beam. The proposed method yielded a maximum computation time 702 times faster than a complete head simulation. Conclusions: Our study demonstrates that there was an excellent agreement between the results of our proposed model and measured data; furthermore, an optimum calculation speed was achieved because there was no need to define geometry and materials in the LINAC head.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 378-382
A modified fast local region based method for image segmentation
Among many different methods of image segmentation, local region based algorithms received noticeable attention. In particular, these algorithms can be practically useful for images with intensity inhomogeneity like medical ultrasound images and tumor images. Although local based algorithms, unlike edge based methods, are insensitive to noise and weak edges, presence of severe noise in the images is still a problem. In this study, a modified local region based method is proposed for solving this problem, additionally the time consuming re-initialization process is removed by using the robust and fast Reaction Diffusion method. Conclusively, the final results reveal that the proposed modified algorithm can achieve more appropriate results in terms of accuracy and speed than five well-known local based methods.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 378-382
A modified fast local region based method for image segmentation
Among many different methods of image segmentation, local region based algorithms received noticeable attention. In particular, these algorithms can be practically useful for images with intensity inhomogeneity like medical ultrasound images and tumor images. Although local based algorithms, unlike edge based methods, are insensitive to noise and weak edges, presence of severe noise in the images is still a problem. In this study, a modified local region based method is proposed for solving this problem, additionally the time consuming re-initialization process is removed by using the robust and fast Reaction Diffusion method. Conclusively, the final results reveal that the proposed modified algorithm can achieve more appropriate results in terms of accuracy and speed than five well-known local based methods.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 169-173
Time-frequency facial gestures EMG analysis using bilinear distribution
Electromyogram (EMG)-based facial gesture recognition has recently drawn the researchers' attention as a potential medium in different areas, particularly in assistive technology and rehabilitation. Efficient analysis of facial neuromuscular signals generated by different facial muscles can provide lots of information about underlying facial movement mechanisms which can be used to characterize different facial gestures as well as muscle abnormalities like in patients with muscular dystrophy or facial palsy. This paper investigated time-varying properties of facial EMGs in time-frequency domain. Significantly we studied changes of EMG spectrum across time while performing ten different facial gestures. The facial gestures were recorded from ten individuals through three bipolar pairs of surface electrodes. Time-Frequency analysis was carried out using B-Distribution to resolve EMG components in time-frequency domain and specify the signal frequency components that change over time. We observed that 1) there were no significant differences among facial gestures EMG time-varying spectrum distributions, 2) EMG power spectrum decreased over time in each epoch after about one second from the beginning of each movement, 3) the most significant power spectrum of facial EMGs was within 60-300 Hz.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 169-173
Time-frequency facial gestures EMG analysis using bilinear distribution
Electromyogram (EMG)-based facial gesture recognition has recently drawn the researchers' attention as a potential medium in different areas, particularly in assistive technology and rehabilitation. Efficient analysis of facial neuromuscular signals generated by different facial muscles can provide lots of information about underlying facial movement mechanisms which can be used to characterize different facial gestures as well as muscle abnormalities like in patients with muscular dystrophy or facial palsy. This paper investigated time-varying properties of facial EMGs in time-frequency domain. Significantly we studied changes of EMG spectrum across time while performing ten different facial gestures. The facial gestures were recorded from ten individuals through three bipolar pairs of surface electrodes. Time-Frequency analysis was carried out using B-Distribution to resolve EMG components in time-frequency domain and specify the signal frequency components that change over time. We observed that 1) there were no significant differences among facial gestures EMG time-varying spectrum distributions, 2) EMG power spectrum decreased over time in each epoch after about one second from the beginning of each movement, 3) the most significant power spectrum of facial EMGs was within 60-300 Hz.