Kevin D. Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kevin D. Brown has a total of 109 co-authors. Here are the top co-authors by number of shared publications:
- Margaret T. Dillon
Department of Otolaryngology-Head and Neck Surgery, University of North Carolina at Chapel Hill
23 shared publications Margaret E. Richter
Department of Otolaryngology/Head and Neck Surgery University of North Carolina School of Medicine Chapel Hill North Carolina USA
11 shared publicationsMatthew M. Dedmon
Department of Otolaryngology/Head and Neck Surgery University of North Carolina at Chapel Hill Chapel Hill North Carolina USA
10 shared publicationsMeredith A. Rooth
Department of Otolaryngology/Head & Neck Surgery University of North Carolina at Chapel Hill Chapel Hill North Carolina USA
10 shared publications- Lisa R. Park
Department of Otolaryngology/Head and Neck Surgery University of North Carolina School of Medicine Chapel Hill North Carolina USA
7 shared publications - Nicholas J. Thompson
Department of Otolaryngology/Head and Neck Surgery University of North Carolina at Chapel Hill Chapel Hill North Carolina USA
7 shared publications
Latest Publications
- 29 October 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques
Objective: This study reviewed the early shifts in low-frequency hearing for cochlear implant (CI) hearing preservation candidates who underwent cochlear implantation using either manual or robotic-assisted insertion of the electrode array and evaluated possible contributing factors such as angular insertion depth (AID), preoperative hearing, and age. Patients: Adult CI hearing preservation candidates (≥18 yr, ≤70 dB HL at 250 Hz) who underwent cochlear implantation with a straight electrode array through a manual or robotic-assisted insertion. Main Outcome Measures: A low-frequency pure tone average (125, 250, and 500 Hz) was calculated from the unaided thresholds obtained preoperatively and within the initial weeks following surgery. Queried data included impedance values measured intraoperatively and at CI activation, and the AID of the most apical electrode contact. Results: Of 120 cases (66 females), 92 underwent manual insertion (median age = 69.0 yrs, interquartile range = 63.5 to 79.0) and 28 underwent robotic-assisted insertion (median age = 67.0 yrs, interquartile range = 60.9 to 76.3). Patients received either a 23, 24, 26, 28, or 31.5 mm electrode array. Significantly less low-frequency pure tone average shift was observed for robotic-assisted insertions ( P = 0.028), shallower AIDs ( P = 0.010), and younger patients ( P = 0.001). There was a significant interaction between insertion group and AID ( P = 0.010), with robotic-assisted insertion demonstrating better hearing preservation at AIDs exceeding 490°. Impedance values did not differ significantly between insertion groups intraoperatively or at CI activation. Conclusions: Robotic-assisted electrode array insertion may support better early hearing preservation compared with manual insertions, particularly for patients with electrode arrays placed at deeper AIDs. Level of Evidence: Level IV; retrospective cohort study.
- 29 October 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
Hearing Preservation as a Function of Angular Insertion Depth With Manual Versus Robotic-Assisted Insertion Techniques
Objective: This study reviewed the early shifts in low-frequency hearing for cochlear implant (CI) hearing preservation candidates who underwent cochlear implantation using either manual or robotic-assisted insertion of the electrode array and evaluated possible contributing factors such as angular insertion depth (AID), preoperative hearing, and age. Patients: Adult CI hearing preservation candidates (≥18 yr, ≤70 dB HL at 250 Hz) who underwent cochlear implantation with a straight electrode array through a manual or robotic-assisted insertion. Main Outcome Measures: A low-frequency pure tone average (125, 250, and 500 Hz) was calculated from the unaided thresholds obtained preoperatively and within the initial weeks following surgery. Queried data included impedance values measured intraoperatively and at CI activation, and the AID of the most apical electrode contact. Results: Of 120 cases (66 females), 92 underwent manual insertion (median age = 69.0 yrs, interquartile range = 63.5 to 79.0) and 28 underwent robotic-assisted insertion (median age = 67.0 yrs, interquartile range = 60.9 to 76.3). Patients received either a 23, 24, 26, 28, or 31.5 mm electrode array. Significantly less low-frequency pure tone average shift was observed for robotic-assisted insertions ( P = 0.028), shallower AIDs ( P = 0.010), and younger patients ( P = 0.001). There was a significant interaction between insertion group and AID ( P = 0.010), with robotic-assisted insertion demonstrating better hearing preservation at AIDs exceeding 490°. Impedance values did not differ significantly between insertion groups intraoperatively or at CI activation. Conclusions: Robotic-assisted electrode array insertion may support better early hearing preservation compared with manual insertions, particularly for patients with electrode arrays placed at deeper AIDs. Level of Evidence: Level IV; retrospective cohort study.
- 9 September 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 47 (10) , e1184-e1190
Influence of Cochlear Microanatomy on Hearing Preservation in Cochlear Implant Recipients
Objective: Identify cochlear microanatomic variables that influence hearing preservation in adult cochlear implant (CI) recipients. Study design: Retrospective review. Setting: Tertiary academic referral center. Patients: Forty-two CI recipients with preoperative unaided thresholds ≤45 dB HL at 250 Hz. Interventions: Cochlear implantation with a 24, 28, or 31.5-mm straight electrode array. Main outcome measures: Preoperative and postoperative imaging were used to extract scala tympani (ST) volume, cochlear duct length (CDL), and cross-sectional measurements (height, width, area, and diameter), as well as angular insertion depth (AID) and cross-sectional measures at the most apical electrode (E A ). Shift in low-frequency pure tone average (LFPTA; 125, 250, and 500 Hz) was computed at activation and at 6 months post activation. Results: A linear mixed-effects model analyzed the effects of cochlear microanatomy (ie, ST volume, CDL, and AID), cross-sectional measurements at E A (height, width, area, and diameter), as well as interval, age at surgery, and biological sex on the shift in LFPTA. Significant effects included biological sex ( P = 0.01) and ST volume ( P = 0.005). Age demonstrated a trend toward significance ( P = 0.052). Interval ( P = 0.26), CDL ( P = 0.80), AID ( P = 0.40), ST height ( P = 0.71), ST width ( P = 0.65), ST diameter ( P = 0.56), and ST cross-sectional area ( P = 0.14) did not significantly influence shift in LFPTA. Conclusions: ST volume and biological sex are significantly predictive of hearing preservation for adult CI recipients. Hearing preservation may be more affected by overall ST volume than by interactions of the electrode with the local environment. Indirect mechanisms of trauma, such as hydraulic pressure as the electrode is inserted, may predominate in damage to intracochlear structures. Future studies are needed to validate these findings with measurement of intraoperative fluid pressure transients in relation to ST volume during array insertion.
- 9 September 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 47 (10) , e1184-e1190
Influence of Cochlear Microanatomy on Hearing Preservation in Cochlear Implant Recipients
Objective: Identify cochlear microanatomic variables that influence hearing preservation in adult cochlear implant (CI) recipients. Study design: Retrospective review. Setting: Tertiary academic referral center. Patients: Forty-two CI recipients with preoperative unaided thresholds ≤45 dB HL at 250 Hz. Interventions: Cochlear implantation with a 24, 28, or 31.5-mm straight electrode array. Main outcome measures: Preoperative and postoperative imaging were used to extract scala tympani (ST) volume, cochlear duct length (CDL), and cross-sectional measurements (height, width, area, and diameter), as well as angular insertion depth (AID) and cross-sectional measures at the most apical electrode (E A ). Shift in low-frequency pure tone average (LFPTA; 125, 250, and 500 Hz) was computed at activation and at 6 months post activation. Results: A linear mixed-effects model analyzed the effects of cochlear microanatomy (ie, ST volume, CDL, and AID), cross-sectional measurements at E A (height, width, area, and diameter), as well as interval, age at surgery, and biological sex on the shift in LFPTA. Significant effects included biological sex ( P = 0.01) and ST volume ( P = 0.005). Age demonstrated a trend toward significance ( P = 0.052). Interval ( P = 0.26), CDL ( P = 0.80), AID ( P = 0.40), ST height ( P = 0.71), ST width ( P = 0.65), ST diameter ( P = 0.56), and ST cross-sectional area ( P = 0.14) did not significantly influence shift in LFPTA. Conclusions: ST volume and biological sex are significantly predictive of hearing preservation for adult CI recipients. Hearing preservation may be more affected by overall ST volume than by interactions of the electrode with the local environment. Indirect mechanisms of trauma, such as hydraulic pressure as the electrode is inserted, may predominate in damage to intracochlear structures. Future studies are needed to validate these findings with measurement of intraoperative fluid pressure transients in relation to ST volume during array insertion.
- Open Access
- 19 August 2026
- Published by Wiley in The Laryngoscope
Multicenter Study Results on Expanded Indications in Med‐EL Pediatric Cochlear Implant Population
Objectives: To demonstrate safety and efficacy of MED‐EL cochlear implants (CIs) in children aged < 12 months and in children aged 12–71 months with residual hearing. Methods: This was a multicenter, nonrandomized, single‐subject, repeated‐measures study with prospective ( N = 38; 26 < 12 months of age) and retrospective ( N = 209; 70 < 12 months of age) arms. All subjects received MED‐EL CIs before age 6 and had safety data for analysis. Thirty‐six of 38 prospective and 92 of 209 retrospective subjects had efficacy data available for analysis. Primary efficacy endpoint hypothesized that ≥ 75% of subjects would meet study‐specific performance goals on speech recognition or auditory skill development measures by 12 months post‐activation. Primary safety endpoint was adverse device effects (ADEs). Results: Twenty‐nine of 36 prospective (80.6%) and 81 of 92 retrospective (88.0%) subjects with 12‐month efficacy data met endpoint performance goals. This included 21 of 25 (84.0%) prospective and 32 of 37 (86.5%) retrospective subjects < 12 months old and 6 of 6 prospective and 30 of 34 (88.2%) retrospective subjects 12–71 months old with residual hearing. Prospective sample size was too small for hypothesis testing, but the retrospective cohort met the primary efficacy endpoint (95% CI: 79.6%, 93.9%; p = 0.002). Nine prospective and 33 retrospective subjects experienced any ADE, including serious ADEs (SADEs) in < 6% of subjects. No unanticipated ADEs. Conclusion: Results suggest that it is appropriate to expand pediatric CI indications to include children aged 7–11 months with profound sensorineural hearing loss (SNHL) and children aged 12–71 months with residual hearing. Level of Evidence: 3
- 19 August 2026
- Published by Wiley in The Laryngoscope
Open AccessMulticenter Study Results on Expanded Indications in Med‐EL Pediatric Cochlear Implant Population
Objectives: To demonstrate safety and efficacy of MED‐EL cochlear implants (CIs) in children aged < 12 months and in children aged 12–71 months with residual hearing. Methods: This was a multicenter, nonrandomized, single‐subject, repeated‐measures study with prospective ( N = 38; 26 < 12 months of age) and retrospective ( N = 209; 70 < 12 months of age) arms. All subjects received MED‐EL CIs before age 6 and had safety data for analysis. Thirty‐six of 38 prospective and 92 of 209 retrospective subjects had efficacy data available for analysis. Primary efficacy endpoint hypothesized that ≥ 75% of subjects would meet study‐specific performance goals on speech recognition or auditory skill development measures by 12 months post‐activation. Primary safety endpoint was adverse device effects (ADEs). Results: Twenty‐nine of 36 prospective (80.6%) and 81 of 92 retrospective (88.0%) subjects with 12‐month efficacy data met endpoint performance goals. This included 21 of 25 (84.0%) prospective and 32 of 37 (86.5%) retrospective subjects < 12 months old and 6 of 6 prospective and 30 of 34 (88.2%) retrospective subjects 12–71 months old with residual hearing. Prospective sample size was too small for hypothesis testing, but the retrospective cohort met the primary efficacy endpoint (95% CI: 79.6%, 93.9%; p = 0.002). Nine prospective and 33 retrospective subjects experienced any ADE, including serious ADEs (SADEs) in < 6% of subjects. No unanticipated ADEs. Conclusion: Results suggest that it is appropriate to expand pediatric CI indications to include children aged 7–11 months with profound sensorineural hearing loss (SNHL) and children aged 12–71 months with residual hearing. Level of Evidence: 3
- 28 April 2026
- Published by Wiley in The Laryngoscope
- Vol. 136 (10) , 4489-4496
Electrode Contacts in the Functional Hearing Region for Pediatric Cochlear Implant Recipients
Objectives: Examine the incidence of one or more electrode contacts placed within the region of functional acoustic hearing and the potential influence of electrode positioning on speech recognition for pediatric cochlear implant (CI) recipients. Methods: A retrospective review for pediatric CI recipients of straight electrode arrays with preserved low‐frequency hearing (an unaided threshold of ≤ 80 dB HL at 250 Hz) was conducted at a tertiary referral center. Intraoperative X‐rays were used to determine the angular insertion depth (AID) of each electrode. Proximity of contacts to the functional acoustic hearing region was calculated using AID and postoperative unaided thresholds. For electric‐acoustic stimulation (EAS) users, the association between proximity values and CNC word recognition in quiet was reviewed at 3‐, 6‐, and 12‐months post‐activation. Results: Among 69 ears, 90% had at least one electrode contact within the functional acoustic hearing region. Proximity values ranged from −131° to 450° (mean: 100°, SD : 120°). For EAS users with speech recognition data ( n = 29), proximity values were not significantly associated with post‐activation CNC scores ( p ≥ 0.212). Conclusions: Most pediatric CI recipients with hearing preservation had at least one electrode contact in the region of functional acoustic hearing. Proximity was not significantly associated with word recognition in quiet for EAS users, though this subgroup was limited in sample size. Further studies in pediatric EAS users are needed to understand the potential relationship with speech recognition in noise and to determine the benefits of individualizing array selection and/or EAS mapping. Level of Evidence: 3.
- 28 April 2026
- Published by Wiley in The Laryngoscope
- Vol. 136 (10) , 4489-4496
Electrode Contacts in the Functional Hearing Region for Pediatric Cochlear Implant Recipients
Objectives: Examine the incidence of one or more electrode contacts placed within the region of functional acoustic hearing and the potential influence of electrode positioning on speech recognition for pediatric cochlear implant (CI) recipients. Methods: A retrospective review for pediatric CI recipients of straight electrode arrays with preserved low‐frequency hearing (an unaided threshold of ≤ 80 dB HL at 250 Hz) was conducted at a tertiary referral center. Intraoperative X‐rays were used to determine the angular insertion depth (AID) of each electrode. Proximity of contacts to the functional acoustic hearing region was calculated using AID and postoperative unaided thresholds. For electric‐acoustic stimulation (EAS) users, the association between proximity values and CNC word recognition in quiet was reviewed at 3‐, 6‐, and 12‐months post‐activation. Results: Among 69 ears, 90% had at least one electrode contact within the functional acoustic hearing region. Proximity values ranged from −131° to 450° (mean: 100°, SD : 120°). For EAS users with speech recognition data ( n = 29), proximity values were not significantly associated with post‐activation CNC scores ( p ≥ 0.212). Conclusions: Most pediatric CI recipients with hearing preservation had at least one electrode contact in the region of functional acoustic hearing. Proximity was not significantly associated with word recognition in quiet for EAS users, though this subgroup was limited in sample size. Further studies in pediatric EAS users are needed to understand the potential relationship with speech recognition in noise and to determine the benefits of individualizing array selection and/or EAS mapping. Level of Evidence: 3.
- 8 March 2026
- Published by Wiley in The Laryngoscope
- Vol. 136 (7) , 3203-3210
Cochlear Implant Recipients With Electrodes in the Acoustic Region: Long‐Term Hearing Preservation
Objective: It is unknown how electrode array position in the cochlea influences long‐term hearing preservation for cochlear implant (CI) recipients with preserved low‐frequency hearing after surgery. The aim of this study was to evaluate the influence of electrode insertion depth relative to regions of post‐operative acoustic hearing and hearing preservation ≥ 1 year after CI activation. Methods: A retrospective review of adult CI recipients of a straight electrode array from 2017 to 2022 with functional acoustic hearing preservation (≤ 80 dB HL at 250 Hz) at device activation was performed. Proximity was quantified as the angular insertion depth (AID) of the most apical contact relative to the region of preserved functional acoustic hearing. Positive values indicate placement within the functional acoustic region; negative values indicate placement basal to the functional acoustic region. Low‐frequency pure tone average (LFPTA) was queried from the preoperative, device activation, and annual post‐activation visits. Stepwise regression analyzed whether proximity, AID, age, biological sex, and pre‐operative LFPTA were significant predictors for change in unaided hearing thresholds. Results: One hundred and six CI recipients met inclusion criteria. AID ranged from 330° to 717° (mean 513°, SD 79°). Proximity values ranged from −183° to 442° (mean 35°, SD 110°). None of the reviewed independent variables, including proximity, significantly predicted unaided hearing threshold shifts at the 1‐year or the ≥ 3‐year visits ( p ≥ 0.128). Conclusion: Deeper insertion depths and electrode array placement within the functional acoustic hearing region did not predispose CI recipients to delayed loss of residual hearing. Level of Evidence: 4.
- 8 March 2026
- Published by Wiley in The Laryngoscope
- Vol. 136 (7) , 3203-3210
Cochlear Implant Recipients With Electrodes in the Acoustic Region: Long‐Term Hearing Preservation
Objective: It is unknown how electrode array position in the cochlea influences long‐term hearing preservation for cochlear implant (CI) recipients with preserved low‐frequency hearing after surgery. The aim of this study was to evaluate the influence of electrode insertion depth relative to regions of post‐operative acoustic hearing and hearing preservation ≥ 1 year after CI activation. Methods: A retrospective review of adult CI recipients of a straight electrode array from 2017 to 2022 with functional acoustic hearing preservation (≤ 80 dB HL at 250 Hz) at device activation was performed. Proximity was quantified as the angular insertion depth (AID) of the most apical contact relative to the region of preserved functional acoustic hearing. Positive values indicate placement within the functional acoustic region; negative values indicate placement basal to the functional acoustic region. Low‐frequency pure tone average (LFPTA) was queried from the preoperative, device activation, and annual post‐activation visits. Stepwise regression analyzed whether proximity, AID, age, biological sex, and pre‐operative LFPTA were significant predictors for change in unaided hearing thresholds. Results: One hundred and six CI recipients met inclusion criteria. AID ranged from 330° to 717° (mean 513°, SD 79°). Proximity values ranged from −183° to 442° (mean 35°, SD 110°). None of the reviewed independent variables, including proximity, significantly predicted unaided hearing threshold shifts at the 1‐year or the ≥ 3‐year visits ( p ≥ 0.128). Conclusion: Deeper insertion depths and electrode array placement within the functional acoustic hearing region did not predispose CI recipients to delayed loss of residual hearing. Level of Evidence: 4.
- Open Access
- 6 March 2026
- Published by Wiley in The Laryngoscope
- Vol. 136 (7) , 3195-3202
Attrition in Cochlear Implant Research: Sociodemographic, Audiologic, and Performance Variables
Objectives: To understand the sociodemographic, audiologic, and performance variables that influence participant attrition in long‐term, repeated‐measures clinical research. Methods: A retrospective review was completed for adult cochlear implant (CI) recipients who enrolled in an ongoing, repeated‐measures clinical research study investigating outcomes between two mapping procedures. The sample was stratified into those who completed the 12‐month study and those who withdrew prior to the study endpoint. The groups were compared for sociodemographic variables (age at consent, race, ethnicity, biological sex, drive time to the clinic, socioeconomic position, and rurality), cognition, and audiologic variables (device type, ipsilateral and contralateral hearing, device wear‐time, and tonotopic mismatch). Early performance on CNC word recognition was analyzed between groups. Results: Of the 118 research participants, the attrition rate for the sample was 21%. Sociodemographic variables were at parity between the completed and withdrawal groups. Of the reviewed audiologic variables, the withdrawal group had poorer low‐frequency acoustic hearing thresholds, was less likely to be electric‐acoustic stimulation users than CI alone users (likely due to unaided thresholds), and had greater tonotopic mismatch. Early CNC word recognition was significantly different between the two groups, with the completed group having better early performance than the withdrawal group. Conclusion: The present findings serve as a reminder of the need for reflection on clinical research study attrition patterns and a call for intentionally designed study inclusion criteria and procedures to support enrollment and retention of a representative sample. Level of Evidence: 3.
- 6 March 2026
- Published by Wiley in The Laryngoscope
- Vol. 136 (7) , 3195-3202
Open AccessAttrition in Cochlear Implant Research: Sociodemographic, Audiologic, and Performance Variables
Objectives: To understand the sociodemographic, audiologic, and performance variables that influence participant attrition in long‐term, repeated‐measures clinical research. Methods: A retrospective review was completed for adult cochlear implant (CI) recipients who enrolled in an ongoing, repeated‐measures clinical research study investigating outcomes between two mapping procedures. The sample was stratified into those who completed the 12‐month study and those who withdrew prior to the study endpoint. The groups were compared for sociodemographic variables (age at consent, race, ethnicity, biological sex, drive time to the clinic, socioeconomic position, and rurality), cognition, and audiologic variables (device type, ipsilateral and contralateral hearing, device wear‐time, and tonotopic mismatch). Early performance on CNC word recognition was analyzed between groups. Results: Of the 118 research participants, the attrition rate for the sample was 21%. Sociodemographic variables were at parity between the completed and withdrawal groups. Of the reviewed audiologic variables, the withdrawal group had poorer low‐frequency acoustic hearing thresholds, was less likely to be electric‐acoustic stimulation users than CI alone users (likely due to unaided thresholds), and had greater tonotopic mismatch. Early CNC word recognition was significantly different between the two groups, with the completed group having better early performance than the withdrawal group. Conclusion: The present findings serve as a reminder of the need for reflection on clinical research study attrition patterns and a call for intentionally designed study inclusion criteria and procedures to support enrollment and retention of a representative sample. Level of Evidence: 3.
- 29 September 2025
- Published by Wiley in The Laryngoscope
- Vol. 136 (3) , 1469-1474
Association of Tonotopic Mismatch and Cochlear Implant Use on Outcomes for Adults With Unilateral Hearing Loss
Objective: Review whether tonotopic mismatch and device use are associated with speech recognition for adult cochlear implant (CI) users with unilateral hearing loss (UHL). Methods: Performance with the CI alone (CNC word scores) and in the CI plus the normal hearing (NH) ear condition (CI + NH; BKB‐SIN scores) at 6 months post‐activation was reviewed. For BKB‐SIN, the target was presented from the front and the masker was presented toward the NH ear. Mismatch for the most apical electrode contact was determined using imaging and the filter frequencies of each patient's familiar map. Device use was obtained from datalogging reports. Results: For the 32 CI recipients, mismatch ranged from −27 to 21 semitones (mean: −8; SD: 10). Mismatch was not significantly associated with CNC scores ( r (32) = −0.25, p = 0.083) but was with BKB‐SIN scores ( r (26) = 0.38, p = 0.030). Device use ranged from 1 to 14 h (mean: 7; SD: 5). Device use was significantly associated with CNC ( r (24) = 0.56, p = 0.002) and BKB‐SIN ( r (21) = −0.49, p = 0.012) scores. The relationship between mismatch and device use was not significant ( r (24) = −0.11, p = 0.308). Conclusion: CI users with UHL experienced better speech recognition when tonotopic mismatches were minimal or not present, and when they listened to their CI for multiple hours a day. These data suggest that CI users with UHL may experience their best performance with consistent device use and when listening to maps with minimal or no tonotopic mismatch. The lack of a significant association between mismatch and device use suggests other variables may be influencing the consistency of device use. Level of Evidence: 4.
- 29 September 2025
- Published by Wiley in The Laryngoscope
- Vol. 136 (3) , 1469-1474
Association of Tonotopic Mismatch and Cochlear Implant Use on Outcomes for Adults With Unilateral Hearing Loss
Objective: Review whether tonotopic mismatch and device use are associated with speech recognition for adult cochlear implant (CI) users with unilateral hearing loss (UHL). Methods: Performance with the CI alone (CNC word scores) and in the CI plus the normal hearing (NH) ear condition (CI + NH; BKB‐SIN scores) at 6 months post‐activation was reviewed. For BKB‐SIN, the target was presented from the front and the masker was presented toward the NH ear. Mismatch for the most apical electrode contact was determined using imaging and the filter frequencies of each patient's familiar map. Device use was obtained from datalogging reports. Results: For the 32 CI recipients, mismatch ranged from −27 to 21 semitones (mean: −8; SD: 10). Mismatch was not significantly associated with CNC scores ( r (32) = −0.25, p = 0.083) but was with BKB‐SIN scores ( r (26) = 0.38, p = 0.030). Device use ranged from 1 to 14 h (mean: 7; SD: 5). Device use was significantly associated with CNC ( r (24) = 0.56, p = 0.002) and BKB‐SIN ( r (21) = −0.49, p = 0.012) scores. The relationship between mismatch and device use was not significant ( r (24) = −0.11, p = 0.308). Conclusion: CI users with UHL experienced better speech recognition when tonotopic mismatches were minimal or not present, and when they listened to their CI for multiple hours a day. These data suggest that CI users with UHL may experience their best performance with consistent device use and when listening to maps with minimal or no tonotopic mismatch. The lack of a significant association between mismatch and device use suggests other variables may be influencing the consistency of device use. Level of Evidence: 4.
- Open Access
- 20 February 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (5) , 499-504
Speech Recognition for Pediatric Electric–Acoustic Stimulation Users with Unilateral Hearing Loss
Objective: Pediatric cochlear implant (CI) recipients with unilateral hearing loss (UHL) and functional low-frequency acoustic hearing in the implanted ear could be fit with an electric–acoustic stimulation (EAS) device, which is the combination of acoustic and CI technologies in one device. Outcomes for this unique patient population are currently unknown. The present study assessed the speech recognition of pediatric EAS users with UHL. Study Design: Retrospective review. Setting: Tertiary academic referral center. Patients: Pediatric CI recipients with functional acoustic hearing in the implanted ear (i.e., ≤ 80 dB HL) and a contralateral pure-tone average (0.5, 1, 2, and 4 kHz) ≤ 25 dB HL. Main Outcome Measures: Speech recognition was assessed with the consonant–nucleus–consonant (CNC) test for the affected ear preoperatively and at 6 and 12 months postactivation. Masked speech recognition was assessed with the Bamford–Kowal–Bench speech-in-noise test in the bilateral condition for three spatial configurations: target from the front and masker colocated with the target or presented 90° toward the implanted or contralateral ear. Results: Children experienced a significant improvement in CNC scores with EAS as compared to preoperative abilities with a hearing aid (F(2,7) = 10.0, p = 0.009). Preliminary masked sentence recognition data suggest a benefit in performance when the target was spatially separated from the masker, and a benefit with EAS as compared to an unaided listening condition. Conclusions: Children with UHL and functional acoustic hearing in the implanted ear experience better speech recognition with EAS as compared to preoperative abilities or listening unaided.
- 20 February 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (5) , 499-504
Open AccessSpeech Recognition for Pediatric Electric–Acoustic Stimulation Users with Unilateral Hearing Loss
Objective: Pediatric cochlear implant (CI) recipients with unilateral hearing loss (UHL) and functional low-frequency acoustic hearing in the implanted ear could be fit with an electric–acoustic stimulation (EAS) device, which is the combination of acoustic and CI technologies in one device. Outcomes for this unique patient population are currently unknown. The present study assessed the speech recognition of pediatric EAS users with UHL. Study Design: Retrospective review. Setting: Tertiary academic referral center. Patients: Pediatric CI recipients with functional acoustic hearing in the implanted ear (i.e., ≤ 80 dB HL) and a contralateral pure-tone average (0.5, 1, 2, and 4 kHz) ≤ 25 dB HL. Main Outcome Measures: Speech recognition was assessed with the consonant–nucleus–consonant (CNC) test for the affected ear preoperatively and at 6 and 12 months postactivation. Masked speech recognition was assessed with the Bamford–Kowal–Bench speech-in-noise test in the bilateral condition for three spatial configurations: target from the front and masker colocated with the target or presented 90° toward the implanted or contralateral ear. Results: Children experienced a significant improvement in CNC scores with EAS as compared to preoperative abilities with a hearing aid (F(2,7) = 10.0, p = 0.009). Preliminary masked sentence recognition data suggest a benefit in performance when the target was spatially separated from the masker, and a benefit with EAS as compared to an unaided listening condition. Conclusions: Children with UHL and functional acoustic hearing in the implanted ear experience better speech recognition with EAS as compared to preoperative abilities or listening unaided.
- 27 January 2025
- Published by Wiley in The Laryngoscope
- Vol. 135 (6) , 2139-2145
Effects of Interaural Latency and Frequency Mismatch on Speech Recognition for Bimodal Cochlear Implant Users
Objectives: Bimodal cochlear implant (CI) users vary in speech recognition outcomes. This variability may be influenced partly by the CI and contralateral hearing aid (HA) programming procedures, which can result in mismatches in latency and frequency. We assessed the performance of bimodal listeners when latency mismatches were corrected and analyzed how frequency mismatches influenced outcomes.Methods: Twelve adults with at least 1 year of bimodal use were evaluated in latency mismatched versus matched conditions. Masked sentence recognition was assessed in a 10‐talker masker for three spatial configurations: target from the front and the masker either co‐located, 90° toward the CI‐ear, or 90° toward the HA‐ear. Frequency mismatch for the most apical electrode (E1) was determined from postoperative imaging and the filter frequency assignment of their familiar CI map.Results: Participants had significantly better performance when latency mismatches were small or matched between the devices, with an approximately 10% improvement in the configuration with the masker toward the HA‐ear. Significantly, poorer performance was observed with larger magnitudes of frequency mismatch, with a 2% drop in performance for every one semitone deviation increase in mismatch. The interaction between latency and frequency mismatch was nonsignificant, suggesting that the benefit of latency matching was approximately additive across the range of frequency mismatches.Conclusions: Detrimental effects of interaural mismatches in latency and frequency were observed, even after long‐term device use. These preliminary results suggest that bimodal CI users might benefit from individualized fitting procedures that match latency across devices and minimize frequency mismatch for the CI.Level of Evidence: 3 Laryngoscope, 135:2139–2145, 2025
- 27 January 2025
- Published by Wiley in The Laryngoscope
- Vol. 135 (6) , 2139-2145
Effects of Interaural Latency and Frequency Mismatch on Speech Recognition for Bimodal Cochlear Implant Users
Objectives: Bimodal cochlear implant (CI) users vary in speech recognition outcomes. This variability may be influenced partly by the CI and contralateral hearing aid (HA) programming procedures, which can result in mismatches in latency and frequency. We assessed the performance of bimodal listeners when latency mismatches were corrected and analyzed how frequency mismatches influenced outcomes.Methods: Twelve adults with at least 1 year of bimodal use were evaluated in latency mismatched versus matched conditions. Masked sentence recognition was assessed in a 10‐talker masker for three spatial configurations: target from the front and the masker either co‐located, 90° toward the CI‐ear, or 90° toward the HA‐ear. Frequency mismatch for the most apical electrode (E1) was determined from postoperative imaging and the filter frequency assignment of their familiar CI map.Results: Participants had significantly better performance when latency mismatches were small or matched between the devices, with an approximately 10% improvement in the configuration with the masker toward the HA‐ear. Significantly, poorer performance was observed with larger magnitudes of frequency mismatch, with a 2% drop in performance for every one semitone deviation increase in mismatch. The interaction between latency and frequency mismatch was nonsignificant, suggesting that the benefit of latency matching was approximately additive across the range of frequency mismatches.Conclusions: Detrimental effects of interaural mismatches in latency and frequency were observed, even after long‐term device use. These preliminary results suggest that bimodal CI users might benefit from individualized fitting procedures that match latency across devices and minimize frequency mismatch for the CI.Level of Evidence: 3 Laryngoscope, 135:2139–2145, 2025
- 30 December 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (3) , 272-278
Effects of Insertion Depth and Modiolar Proximity on Cochlear Implant Speech Recognition Outcomes With a Precurved Electrode Array
Objectives: To examine the relationship between angular insertion depth (AID), modiolar proximity, and speech recognition outcomes for cochlear implant (CI) recipients of a precurved electrode array. Study Design: Retrospective review. Setting: Tertiary academic referral center. Patients: Thirty-five adult CI recipients (n = 40 ears) of precurved electrode arrays listening with a CI-alone device. Interventions: Cochlear implantation with postoperative computed tomography. Main Outcome Measures: Consonant-nucleus-consonant (CNC) word recognition at 6 months post-activation. Results: A multivariate regression model demonstrated that both deeper apical AID and closer modiolar proximity in the basal turn were independently associated with better CNC word scores at 6 months (F 2,37 = 7.264, p = 0.002). A deeper basal insertion depth was positively correlated with apical AID (r = 0.754, p < 0.001) but negatively correlated with modiolar proximity in the basal turn (r = −0.766, p < 0.001). Conclusions: These data suggest that both apical cochlear coverage and modiolar proximity independently confer speech recognition benefit with a precurved array. However, these benefits are mutually exclusive for current precurved array designs as a deeper basal insertion depth results in greater apical coverage but lateralization of electrodes away from the modiolus in the basal turn. Future work is needed to elucidate mechanisms behind these findings that may motivate electrode array design modifications to further optimize outcomes for CI users.
- 30 December 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (3) , 272-278
Effects of Insertion Depth and Modiolar Proximity on Cochlear Implant Speech Recognition Outcomes With a Precurved Electrode Array
Objectives: To examine the relationship between angular insertion depth (AID), modiolar proximity, and speech recognition outcomes for cochlear implant (CI) recipients of a precurved electrode array. Study Design: Retrospective review. Setting: Tertiary academic referral center. Patients: Thirty-five adult CI recipients (n = 40 ears) of precurved electrode arrays listening with a CI-alone device. Interventions: Cochlear implantation with postoperative computed tomography. Main Outcome Measures: Consonant-nucleus-consonant (CNC) word recognition at 6 months post-activation. Results: A multivariate regression model demonstrated that both deeper apical AID and closer modiolar proximity in the basal turn were independently associated with better CNC word scores at 6 months (F 2,37 = 7.264, p = 0.002). A deeper basal insertion depth was positively correlated with apical AID (r = 0.754, p < 0.001) but negatively correlated with modiolar proximity in the basal turn (r = −0.766, p < 0.001). Conclusions: These data suggest that both apical cochlear coverage and modiolar proximity independently confer speech recognition benefit with a precurved array. However, these benefits are mutually exclusive for current precurved array designs as a deeper basal insertion depth results in greater apical coverage but lateralization of electrodes away from the modiolus in the basal turn. Future work is needed to elucidate mechanisms behind these findings that may motivate electrode array design modifications to further optimize outcomes for CI users.