Effects of Insertion Depth and Modiolar Proximity on Cochlear Implant Speech Recognition Outcomes With a Precurved Electrode Array
- 30 December 2024
- journal article
- cochlear implants
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (3) , 272-278
Abstract
Objectives: To examine the relationship between angular insertion depth (AID), modiolar proximity, and speech recognition outcomes for cochlear implant (CI) recipients of a precurved electrode array. Study Design: Retrospective review. Setting: Tertiary academic referral center. Patients: Thirty-five adult CI recipients (n = 40 ears) of precurved electrode arrays listening with a CI-alone device. Interventions: Cochlear implantation with postoperative computed tomography. Main Outcome Measures: Consonant-nucleus-consonant (CNC) word recognition at 6 months post-activation. Results: A multivariate regression model demonstrated that both deeper apical AID and closer modiolar proximity in the basal turn were independently associated with better CNC word scores at 6 months (F 2,37 = 7.264, p = 0.002). A deeper basal insertion depth was positively correlated with apical AID (r = 0.754, p < 0.001) but negatively correlated with modiolar proximity in the basal turn (r = −0.766, p < 0.001). Conclusions: These data suggest that both apical cochlear coverage and modiolar proximity independently confer speech recognition benefit with a precurved array. However, these benefits are mutually exclusive for current precurved array designs as a deeper basal insertion depth results in greater apical coverage but lateralization of electrodes away from the modiolus in the basal turn. Future work is needed to elucidate mechanisms behind these findings that may motivate electrode array design modifications to further optimize outcomes for CI users.Keywords
This publication has 45 references indexed in Scilit:
- Frequency‐to‐Place Mismatch Impacts Cochlear Implant Quality of Life, But Not Speech RecognitionThe Laryngoscope, 2024
- Improved Cochlear Implant Performance Estimation Using Tonotopic-Based ElectrocochleographyJAMA Otolaryngology–Head & Neck Surgery, 2023
- Relationship between electrode position and temporal modulation sensitivity in cochlear implant users: Are close electrodes always better?Heliyon, 2022
- Towards a Functional Atraumatic Self‐Shaping Cochlear ImplantMacromolecular Materials and Engineering, 2022
- Long‐Term Influence of Electrode Array Length on Speech Recognition in Cochlear Implant UsersThe Laryngoscope, 2020
- Scalar localisation of peri-modiolar electrodes and speech perception outcomesThe Journal of Laryngology & Otology, 2018
- Insertion depth impacts speech perception and hearing preservation for lateral wall electrodesThe Laryngoscope, 2017
- Insertion trauma of a cochlear implant electrode array with Nitinol inlayEuropean Archives of Oto-Rhino-Laryngology, 2016
- Masking patterns for monopolar and phantom electrode stimulation in cochlear implantsHearing Research, 2013
- Revised CNC Lists for Auditory TestsJournal of Speech and Hearing Disorders, 1962