AKAvinash Kumar

Avinash Kumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Avinash Kumar has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dynamic State Estimation for Inverter-Based Resources: A Control-Physics Dual Estimation Framework

    by Heqing Huang, Yuzhang Lin, Xiaonan Lu, Yue Zhao, Avinash Kumar

    As Inverter-Based Resources (IBRs) gradually replace conventional synchronous generators (SGs), Dynamic State Estimation (DSE) techniques must be extended for the monitoring of IBRs. The key difference between IBRs and SGs is that the dynamics of IBRs comprise a heavy mix of physical processes and digital controller computations. This paper develops a generic framework of Control-Physics Dynamic State Estimation (CPDSE) for IBRs. First, a control-physics state-space representation of IBRs is presented. Noting the symmetry of the control and physical state spaces, it is proposed to use two dual estimators to track the states of the physical inverter subsystem and the digital controller subsystem, respectively. The CPDSE framework has the capability of suppressing errors in both measurement signals and control signals flowing between the two subsystems and the potential to distinguish between cyber and physical events. The advantages and versatility of the proposed CPDSE framework are validated on a variety of IBR systems (solar, wind, and storage), control strategies (grid-following and grid-forming), and both transmission and distribution systems.


  • Open Access

    Real‐time implementation for vulnerability of power components under switching attack based on sliding mode

    by Seema Yadav, Nand Kishor, Shubhi Purwar, Saikat Chakrabarti, Petra Raussi, Avinash Kumar

    In recent years, cyber security‐related studies in the power grid have drawn wide attention, with much focus on its detection, mainly for data injection type of attacks. The vulnerability of power components as a result of attack and their impact on generator dynamics have been largely ignored so far. With the aim of addressing some of these issues, the authors propose a novel approach using real‐time sliding surface‐based switching attack (SA) construction. This approach targets the circuit breaker, excitation system, and governor system of the generator. The vulnerability of these power components to cyber‐physical attacks and assessment of their potential impact on the stability of generator are discussed. The study is presented to show the progression of cascading generator dynamics on account of single or multiple time instants of SA launched on these power components. The results are discussed according to criteria in terms of deviations in rotor speed of the generator and identify some of possible combinations of power components that are most critical to grid stability. The proposed study is implemented on standard IEEE 3‐machine, 9‐bus network in real‐time digital simulator via transmission control protocol/internet protocol (TCP/IP) communication network established as cyber‐physical system. The sliding surface‐based SA algorithm developed in MATLAB is launched from another computer.


  • Adaptive Coordination of Relays in AC Microgrid Considering Operational and Topological Changes

    by Atul Kumar Soni, Avinash Kumar, Rakesh Kumar Panda, Abheejeet Mohapatra, Sri Niwas Singh

    Conventional protection schemes are vulnerable to varying changes in a microgrid with different types of distributed generators (DGs), which alter the fault current levels, leading to miscoordination of directional over-current relays (DOCRs). Due to limited storage in numeric relays, having one setting for each network scenario in the relays is infeasible. Also, schemes with one setting considering grid-connected mode (GCM) and islanded mode (IM) of operation with multiple scenarios may be infeasible for a microgrid with inverter-interfaced DGs due to low short-circuit level in IM. Thus, this article proposes an adaptive trip characteristics-based relay coordination scheme for a microgrid with different DGs, where two trip characteristics are assigned to each DOCR, one each for GCM and IM. Also, a novel framework for selecting the suitable trip characteristic is proposed. Hardware-in-loop simulations using Numerical Relay Development Environment for a meshed CIGRE microgrid, modified IEEE 34-bus distribution system, and comparison with previous works validate the proposed method's performance for various scenarios, such as the outage of a DG or line, variations in solar irradiation and wind speed, and network reconfiguration for different fault types during GCM and IM.


  • Space Vector Rotation-Based Controlled Decaying Current Injection for Islanding Detection of Inverter-Interfaced DG

    by Avinash Kumar, Abheejeet Mohapatra, Sri Niwas Singh, Rakesh Kumar Panda

    Continuous injection-based islanding detection of Inverter-Interfaced Distributed Generator (IIDG) has been a general trend. The major issues in previous islanding detection methods are large Non-Detection Zone (NDZ), poor Power Quality (PQ), high implementation cost, and lack of real-time validation. Further, the threshold in most methods is not generic and depends on the system’s rating. Hence, this paper proposes a local voltage and current measurement-based islanding detection method for IIDGs. It utilizes parameters estimated from the fundamental phasors of voltage and current at the Point of Common Coupling (PCC) of IIDG using Space Vector Rotation (SVR) and a controlled self-decaying current injection. The proposed disturbance is injected only after disturbance detection by SVR parameters to mitigate the impact on PQ. Disturbance identification is easy due to the combined PCC voltage and current effects on parameter estimation. Real-Time Digital Simulator (RTDS) and Controller Hardware In the Loop (CHIL) setup-based results from the proposed method have been obtained and compared with previous methods. These results indicate the proposed method’s real-time efficacy (low islanding detection time) with no NDZ and negligible impact on PQ for different islanding events. Also, the proposed method is independent of the microgrid’s rating and reliable for non-islanding events.


  • Impact of Control Parameters on Short-Circuit Capacity of Inverter Based Sources

    by Atul Kumar Soni, Rakesh Kumar Panda, Avinash Kumar, A. Mohapatra, S. N. Singh, S. C. Srivastava

    The increasing penetration of the Inverter-based Distributed Generators (IDGs) in the power network can significantly affect the performance and reliability of the conventional network protection schemes due to the short-circuit capacity of IDGs. The short-circuit current contribution of IDGs is low compared to the synchronous-based DGs and significantly depends on the parameters of the associated controllers. Thus, the conventional overcurrent-based protection scheme may fail to pick up and negatively hamper the secured operation of the power network in many operating conditions. In this paper, a detailed analysis of the short-circuit behavior of IDGs is discussed. First, an analogy for the short-circuit current characteristic is established as a function of the control parameters of the IDG. Secondly, the proposed analogy is tested for an IDG with a dq controller operating in the grid-connected mode. A numerical simulation is performed on a test system to evaluate the impact of the control parameter on the short-circuit current contributed by the IDG. Further, the analysis is verified on the Real-Time Digital Simulator (RTDS), considering variations in the controller’s parameters.

  • Mode of oscillation based islanding detection of inverter interfaced DG using ESPRIT

    by Avinash Kumar, R.K. Panda, Abheejeet Mohapatra, S.N. Singh, S.C. Srivastava


  • Sequence Measurement-Based Islanding Detection of DGs in Microgrid With Enhanced Power Quality

    by Avinash Kumar, Abheejeet Mohapatra, Sri Niwas Singh

    Maintaining the power quality (PQ) of supply in a microgrid is a challenge due to the massive integration of inverter interfaced distributed generators (IIDGs). Supply's PQ and IIDG controller's transient performance degrade due to continuous, uncontrolled, and nondecaying injections in active methods for islanding detection. Also, active methods have limited application due to increased total harmonic distortion (THD) of current during microgrid's operation. In this article, a novel sequence measurement-based identification of grid disturbance by sensing voltage and current is proposed to control the disturbance injection cycle in the IIDG controller during islanding detection. The disturbance is a low-frequency decaying current injection in the IIDG controller with controlled input. The proposed method is experimentally verified in controller hardware in loop (CHIL) with real-time digital simulator (RTDS) using the TMSF28335 microcontroller and compared with several previous methods. The impact on PQ due to change in the injection points with controlled and uncontrolled injections is also analyzed. The results indicate that the islanding detection time is low. Also, the proposed closed-loop method is effective and reliable due to two-stage screening. The nondetection zone (NDZ) is eliminated with negligible impact on the PQ of supply.


  • Phaselet-Based Limited-Time $q$-Axis DC Offset Voltage Injection for Detection of Islanding of DG and Fault in a Meshed Microgrid

    by Avinash Kumar, Abheejeet Mohapatra, Sri Niwas Singh

    Rapid grid integration of inverter-interfaced distributed generators (DGs) and low-voltage ride-through capability of the smart inverter, as per IEEE 1547 standard, has made unintentional islanding detection (UID) cumbersome. Also, the feeder reconfiguration capability in meshed microgrids with multiple DGs has made the existing UID techniques ineffective. The methods have limitations in UID for small power mismatch conditions characterizing nondetection zone (NDZ). In hybrid methods for UID, a disturbance injection is continuous or for an extended period, which degrades the power quality (PQ) and creates stability issues. Hence, a decentralized closed-loop hybrid islanding detection method (HIDM) based on the indices extracted from the subcycle phaselet (passive) technique with limited-time (only for two cycles) $q$ -axis dc offset voltage injection (active) is proposed for UID of DGs. The proposed HIDM mitigates the NDZ due to the closed-loop scheme. Subcycle estimations from the phaselet technique result in quick UID and fault detection and classification process. Furthermore, the PQ issue is reduced due to the limited-time voltage injection (based only on the command from phaselet technique) in the proposed HIDM. Simulation results from the real-time digital simulator on a meshed microgrid and performance comparison with other existing methods prove the efficacy of the proposed HIDM.


  • Phaselet Approach for Islanding Detection in Active Distribution Networks

    by Avinash Kumar, B. Ravi Kumar, Rakesh Kumar Panda, Abheejeet Mohapatra, S. N. Singh

    A novel moving window phaselet based approach has been proposed in this paper for quick islanding detection (within 5–10ms) in ADNs, even in the case of zero power mismatch/ power balance case. The Instantaneous Phase Angle (IPA) and magnitude of the PCC voltage have been extracted through a linearly moving window phaselet to generate two indices - Phaselet Angle Difference (PAD) and Phaselet Magnitude Difference (PMD) at sub-cycle rate, which are critical parameters in quickly discriminating islanding from non-islanding events in ADNs. These indices also offer the added advantage of quickly classifying the type of fault, in the events of faults in ADN. Real Time Digital Simulator (RTDS) based results prove the efficacy of the proposed phaselet based technique in accurately and dynamically estimating the phasors within sub-cycle interval and quickly detecting islanding, even in power balance case with different load quality factors as per standard.


  • A Synchro-phasor Assisted Optimal Features Based Scheme for Fault Detection and Classification

    by Homanga Bharadhwaj, Avinash Kumar, Abheejeet Mohapatra

    A novel and efficient methodology for comprehensive fault detection and classification by using synchrophasor measurement based variations of a power system is proposed. Presently, Artificial Intelligence (AI) techniques have been used in power system protection owing to the greater degree of automation and robustness offered by AI. Evolutionary techniques like Genetic Algorithm (GA) are efficient optimization procedures mimicking the processes of biological evolution that have been shown to perform better than their gradient based counterparts in many problems. We propose a combined GA and Particle Swarm Optimization (PSO) approach to find the optimal features relevant to our fault detection process. As is evidenced by recent advances in multi-modal learning, it has been shown that this combined approach yields a more accurate feature optimization than that obtained by a single meta-heuristic. A systematic comparison of Artificial Neural Network (ANN) and Support Vector Machine (SVM) based methods for fault classification using the identified optimal features is presented. The proposed algorithm can be effectively used for real time fault detection and also for performing postmortem analysis on signals. We demonstrate its effectiveness by simulation results on real world data from the North American SynchroPhasor Initiative (NASPI) and signal variations from a test distribution system.