  • Robust Protection Coordination of Directional Over-Current Relays in AC Microgrids

    by Atul Kumar Soni, Anamika Tiwari, Abheejeet Mohapatra, Sri Niwas Singh

    Conventional protection coordination in AC microgrids often assumes a single network topology to determine optimal settings for Directional Over-Current Relays (DOCRs), leading to miscoordinations when unconsidered scenarios arise. Unlike previous schemes considering various network scenarios, this paper introduces a novel two-stage protection coordination scheme for DOCRs in an AC microgrid using a robust optimization approach to address the above limitation, wherein the first stage determines two optimal DOCRs settings, one each for Grid-Connected Mode (GCM) and Islanded Mode (IM), and the associated dual variables. The second stage identifies the worst-case scenarios for each DOCR pair, including line and Distributed Generator (DG) outages, varying DGs' injections, and resistive faults, each in GCM and IM. The proposed approach significantly reduces the protection coordination constraints required to obtain the settings, thereby reducing solver execution time and improving computational efficiency. Extensive tests on modified IEEE $13-$bus and IEEE $34-$bus AC microgrids with synchronous and inverter-interfaced DGs, and comparison with previous schemes underscore the reliability of the proposed approach under diverse AC microgrid operating conditions.

  • Optimal Over-Current Protection Coordination in AC Microgrid via Novel Pickup Scaling Coefficient

    by Atul Kumar Soni, Abheejeet Mohapatra, Sri Niwas Singh

    AC microgrid protection schemes are often compromised by dynamic changes introduced by diverse Distributed Generators (DGs). These dynamic variations, resulting from different DG types and sizes in Grid-Connected Mode (GCM), Islanded Mode (IM), and network topologies emerging from line and DG outages, significantly alter the fault current levels and lead to miscoordination of conventional Directional Over-Current Relays (DOCRs). Hence, this paper introduces an adaptive protection strategy utilizing a novel pickup scaling coefficient, which adjusts relay settings based on local voltage and current measurements. Further, the proposed method is the first AC microgrid protection strategy capable of maintaining consistent relay operating times and Coordination Time Intervals (CTIs) across different topologies, including GCM, IM, line, and DG outages and varying DGs' injections, by determining a single optimal set of DOCR settings. Extensive simulations for various faults, including high resistance faults, in different scenarios of modified IEEE $13-$bus distribution network with synchronous and inverter-interfaced and comparison with previous works validate the proposed adaptive pickup, ensuring improved sensitivity, selectivity and reliability of the proposed method under diverse operating conditions. Further, Controller-Hardware-Loop (CHIL) simulations using TI-LAUNCHXL-F28379D DSP board and Real-Time Digital Simulator (RTDS) validate the real-time feasibility of the proposed method for varying scenarios.


  • Protection Coordination in AC Microgrid via Novel Voltage-Supervised Directional Over-Current Relays

    by Atul Kumar Soni, Abheejeet Mohapatra, Sri Niwas Singh

    Conventional protection schemes are susceptible to dynamic changes in AC microgrids having diverse Distributed Generators (DGs). These changes, caused by different DG types, significantly alter the fault current levels, leading to conventional Directional Over-Current Relays (DOCRs) miscoordination. The feasibility of using a single set of settings in conventional DOCRs for Grid-Connected Mode (GCM) and Islanded Mode (IM) of operation of AC microgrid is often hindered in the presence of inverter-interfaced DGs due to relatively low short-circuit levels in IM. Hence, this paper uses a novel local voltage measurement-based pickup setting of DOCRs, where the relay operating time is a function of relay voltage and current. A protection coordination problem is also solved to obtain a single set of optimal settings for these DOCRs, which are feasible for various operating scenarios, including GCM, IM, line, and DG outages in an unbalanced AC microgrid. Simulations for different faults in the modified IEEE 13-bus network with synchronous and inverter-interfaced DGs and comparison with previous works validate the reliability and reduced relay operating times in the proposed method. The Controller Hardware-In-Loop (CHIL) simulation using the Real-Time Digital Simulator (RTDS) and dSPACE DS1104 DSP board validates the proposed method's real-time efficacy.


  • Adaptive Coordination of Relays in AC Microgrid Considering Operational and Topological Changes

    by Atul Kumar Soni, Avinash Kumar, Rakesh Kumar Panda, Abheejeet Mohapatra, Sri Niwas Singh

    Conventional protection schemes are vulnerable to varying changes in a microgrid with different types of distributed generators (DGs), which alter the fault current levels, leading to miscoordination of directional over-current relays (DOCRs). Due to limited storage in numeric relays, having one setting for each network scenario in the relays is infeasible. Also, schemes with one setting considering grid-connected mode (GCM) and islanded mode (IM) of operation with multiple scenarios may be infeasible for a microgrid with inverter-interfaced DGs due to low short-circuit level in IM. Thus, this article proposes an adaptive trip characteristics-based relay coordination scheme for a microgrid with different DGs, where two trip characteristics are assigned to each DOCR, one each for GCM and IM. Also, a novel framework for selecting the suitable trip characteristic is proposed. Hardware-in-loop simulations using Numerical Relay Development Environment for a meshed CIGRE microgrid, modified IEEE 34-bus distribution system, and comparison with previous works validate the proposed method's performance for various scenarios, such as the outage of a DG or line, variations in solar irradiation and wind speed, and network reconfiguration for different fault types during GCM and IM.


  • Impact of Control Parameters on Short-Circuit Capacity of Inverter Based Sources

    by Atul Kumar Soni, Rakesh Kumar Panda, Avinash Kumar, A. Mohapatra, S. N. Singh, S. C. Srivastava

    The increasing penetration of the Inverter-based Distributed Generators (IDGs) in the power network can significantly affect the performance and reliability of the conventional network protection schemes due to the short-circuit capacity of IDGs. The short-circuit current contribution of IDGs is low compared to the synchronous-based DGs and significantly depends on the parameters of the associated controllers. Thus, the conventional overcurrent-based protection scheme may fail to pick up and negatively hamper the secured operation of the power network in many operating conditions. In this paper, a detailed analysis of the short-circuit behavior of IDGs is discussed. First, an analogy for the short-circuit current characteristic is established as a function of the control parameters of the IDG. Secondly, the proposed analogy is tested for an IDG with a dq controller operating in the grid-connected mode. A numerical simulation is performed on a test system to evaluate the impact of the control parameter on the short-circuit current contributed by the IDG. Further, the analysis is verified on the Real-Time Digital Simulator (RTDS), considering variations in the controller’s parameters.