BBBukola Olalekan Bolaji

Bukola Olalekan Bolaji

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bukola Olalekan Bolaji has a total of 79 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating the Efficiency of a Solar‐Powered Refrigeration System Enhanced With Phase‐Change Materials and Eco‐Conscious Refrigerants

    by Adedotun Adetunla, Olarewaju Oginni, Bukola Bolaji, Tien-Chien Jen

    The growing demand for energy efficiency, renewable energy, green technology, and thermal energy‐efficient systems, particularly in energy‐limited economies, is crucial for addressing the energy supply–demand imbalance in cooling applications. The study uses eutectic phase‐change material (PCM) solutions for thermal energy storage in a solar‐powered domestic refrigerator, aimed at eliminating greenhouse gas emissions, maintaining temperature during power outages, and conserving energy in both developing and advanced economies. A photovoltaic panel connected the refrigerator by creating a sufficient potential difference to activate and run it constantly. The direct current that powers the compressor was initially generated from sunlight and then transformed into alternating current. An insulated thermal tank with a 5‐kg eutectic PCM heat source was attached to the evaporator chamber, whereas eco‐friendly R‐600, R‐290, and R‐717 refrigerants were selected owing to safety, excellent thermodynamic properties, cost‐effectiveness, and nontoxicity. The refrigerants were circulated for cooling effects and coefficient of performance comparison metrics. Using PVsyst 8.0 software, a parametric study was conducted to examine the efficiency of a solar PVP‐driven refrigeration system and the PCM effect. Analysis and determination were done on the voltage, energy, and energetic efficiency changes of PVP and system performance. With a maximum solar intensity of 903 W/m 2 , a rise in cell temperature to 56.11°C resulted in a 15.56% energy efficiency at 13 h. Owing to the decreased cell temperature of 35.9°C, the energy efficiency was found to be 19.15% at 17 h. There were 31.6% and 36% decreases in compressor work and energy consumption off times and a 20% COP improvement. The system has a boundary condition of 30°C–20°C ambient temperature range, 21.2‐kg load size, and 360‐MJ refrigeration capacity. The selection of refrigerants (R‐600, R‐290, and R‐717) for freezing applications in retrofitting R410A has been determined to have COP values of 7.0, 4.5, and 4.0, respectively. The study demonstrates that PV‐refrigerator systems combined with PCM significantly reduce operating costs, energy conservation, and greenhouse gas emissions; provide sustainable storage solutions; and enhance food security, particularly when the local grid is unavailable.

  • Open Access

    Experimental Application of DMAIC for Equipment Efficiency Improvement in Cocoa Processing Plant

    by Adegoke E. Olusesan, Bukola O. Bolaji, Bayode J. Olorunfemi, Abraham O. Oloye

    In dealing with productivity within the manufacturing operations, the first focus is efficiency improvement. Efficiency improvement can be operational efficiency or asset efficiency. Asset efficiency is best explained by Overall Equipment Effectiveness (OEE). Equipment efficiency has been one of the major perennial problems of the cocoa processing plant due to the nature of the raw materials (main crop and lean crop) used. Lean crops proved to be cocoa beans with low quality, low yield, and difficult to process. During lean crop season, equipment efficiency used to drop compared to the main crop. Cocoa processing is the conversion of raw cocoa beans to finished products such as cocoa butter, cocoa powder, cocoa cake, and cocoa liquor. This work looks at the application of DMAIC (Define, Measure, Analyse, Improve, and Control) to improve the equipment efficiency in the cocoa processing plant. The methodology used is DMAIC. The define phase gives definitions and scope of the problem, The Measure Phase applies statistical methods to measure the current situation and analyze the phase that gives a proper root cause analysis of the problem. Improve phase tends to solve and improve the situation. The control phase makes use of Control Charts. The case study factory has its Tempering machine as its bottleneck and this recorded 40% efficiency loss. Its overall standard deviation is 2.8244 before improvement and became 2.20 after improvement. Pareto shows that the biggest problem is from the sector control system. This work concluded that DMAIC is well-suitable as the structured problem-solving tool for the cocoa processing company.

  • Open Access

    Performance assessment of a refrigeration system with an integrated condenser under different environmental conditions

    by S.O. Banjo, B.O. Bolaji, O.A. Oyelaran, P.O. Babalola, A.S. Afolalu, E.Y. Salawu, M.E. Emetere


  • Open Access

    Energy and cooling performance of carbon-dioxide and hydrofluoroolefins blends as eco-friendly substitutes for R410A in air-conditioning systems

    by Bukola Olalekan Bolaji, Deborah Olufunke Bolaji, Semiu Taiwo Amosun

    Air-conditioning and refrigeration systems are electrical appliances that use a huge amount of energy and contribute indirectly to global warming. Also, R410A which was initially developed as a substitute for ozone-depleting refrigerants in the air-conditioning systems has been phase-out due to its high global warming potential (GWP) and the resulting harmful effect on the climate. In addition to the issue of refrigerant high GWP, energy consumption is a significant issue. The energy efficiency of new refrigerants must then be considered in the search for alternative refrigerants to ensure that they do not lead to an increase in greenhouse gas generation at the power source. Therefore, this paper investigates the energy and cooling performance of four new multi-components and ecologically friendly refrigerant blends that contained carbon dioxide and hydrofluoroolefins in their compositions as substitutes for R410A in air-conditioning systems. Relevant thermodynamic equations and REFPROP software were employed for the computational analysis. The results indicated that the new blends (R445A, R455A, R470B and R470A) exhibited a desirable low compression ratio and high heat transfer for cooling applications. The blends also exhibited low compressor energy input and low specific cooling energy. R455A has an average coefficient of performance (COP) of 24.6% above that of the reference refrigerant (R410A). The cooling capacity per unit volume for R470B, R455A and R470A across a temperature range of 253 to 293 K are higher by 1.3, 6.0, and 12.6%, respectively than that of R410A. Generally, among all the four new substitute blends, the overall assessment revealed R455A as the best replacement for R410A in air-conditioning systems due to its superior performance in terms of its low compression ratio, compressor energy and specific cooling energy. R455A also has the highest COP and relatively high cooling capacity per unit volume.


  • Open Access

    The effect of an evolutionary algorithm's rapid convergence on improving DC motor response using a PID controller

    by Oluwaseun Opeyemi Martins, Adefemi Adeyemi Adekunle, Matthew Oluwole Arowolo, Daniel C. Uguru-Okorie, Bukola Olalekan Bolaji


  • Open Access

    Computational modelling and simulation of the feasibility of a novel dual purpose solar chimney for power generation and passive ventilation in buildings

    by Abayomi T. Layeni, M. Adekojo Waheed, Babatunde A. Adewumi, Bukola O. Bolaji, Collins N. Nwaokocha, Solomon. O Giwa


  • Open Access

    Experimental analysis of the performance characteristic of an eco-friendly HC600a as a retrofitting refrigerant in a thermal system

    by S.O. Banjo, B.O. Bolaji, I. Osagie, O.S.I. Fayomi, O.B. Fakehinde, P.S. Olayiwola, S.O. Oyedepo, N. E. Udoye

    The negative influence of refrigerants on the climate and the immediate environment in terms of their higher global warming potential (GWP) and ozone depletion potential (ODP) has prompted this study. Currently, natural refrigerants are the preferred alternative refrigerants and hydrocarbon is numbered among these natural refrigerants with zero ODP and negligible GWP. In order to improve and enhance the performance of the refrigeration system, the performance characteristics of the system were investigated experimentally using eco-friendly refrigerant HC600a as alternative to HFC134a. In addition, comparisons were made using refrigerant mass charge of 46 g of isobutane (HC600a) and 70 g of conventional refrigerant (HFC134a). Thermodynamic parametric analysis was conducted using electric power consumption, coefficient of performance (COP), cooling load and pull-down time (PDT) for the used mass charges. REFPROP software was applied to capture the thermodynamic properties of the vapour compression system (VCS). The results showed that the COP increased by 32.2 % when using 46g charge of hydrocarbon refrigerant with energy reduction of 4.5 %. Furthermore, the vapour compression system while using 46 g of isobutane (HC600a) attained an evaporating temperature of -21 °C in 60 minutes while 70 g of HFC134a attained the same temperature in 2 hours 15 minutes, which makes HC600a alternative refrigerant to run in the traditional refrigerator.


  • Open Access

    Exploring Neural Network to Predict Car Tyre Inflation Time and Power Requirement of a Tyre Pressure Control Unit.

    by S.T Amosun, O.D Samuel, P.T Zubairu, B.O Bolaji, S.O Fayomi

    This study used Artificial Neural Network (ANN) for the prediction of power required to inflate different tyre sizes and inflation times. ANN is a widely accepted machine learning method that uses past data to predict future trend. An existing database obtained experimentally from a tyre pressure control test rig was optimized using genetic algorithm(GA) which is an optimization tool that can find better subsets of input variables for importing into ANN. The ANN results were compared with the results obtained experimentally. The results show that the model can be implemented in modern day tyre pressure control designs and be used to predict inflation times and power required to inflate different tyre sizes.


  • Open Access

    Performance enhancement using appropriate mass charge of R600a in a developed domestic refrigerator

    by Solomon O. Banjo, Bukola O. Bolaji, Oluseyi O. Ajayi, Babalola P. Olufemi, Ibhadode Osagie, Anthony O. Onokwai

    This paper presents performance analysis of a domestic refrigeration system using R600a as refrigerant. Investigation was conducted experimentally to select an appropriate refrigerant mass charge for the system and to compute the cooling system performance characteristics under ambient temperature of 29°C. The choice of the hydrocarbon refrigerant (R600a) became so imperative due to notable influence of chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) on global warming and ozone depletion. UNFCCC and Montreal Protocol regulation have banned the use of halogenated refrigerants in cooling and heating systems. The paper reveals that the power consumed by the system using mass charge of 15 g refrigerant was reduced by 9.3 and 10.9% compared with the 10 and 25 g refrigerant mass charges respectively. In addition, the results show that the coefficient of performance (COP) of the refrigeration system while working with 15 g is 24.7 and 20.2% higher than when the system worked with 10 and 25 g refrigerants mass charge respectively. More so, the system attained an evaporator air temperature of -12 °C in 2 hours, which makes 15 g charge refrigerant appropriate for the running of the developed system that has a volume capacity of 68 liters.