Hervé Devanne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hervé Devanne has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
P. Derambure
Neurophysiologie Clinique, Centre Hospitalier Régional Universitaire de Lille, Lille, France; Troubles cognitifs vasculaires et dégénératifs, INSERM U1171, Université de Lille, Lille, France
9 shared publicationsPhilippe Derambure
Univ Lille, UMR‐S‐1172 lilncog Lille France
9 shared publications- Elise Houdayer
Department of Rehabilitation and Functional Recovery, IRCCS San Raffaele Scientific Institute, Milan, Italy
8 shared publications - Arnaud Delval
Univ. Lille, Inserm, CHU Lille, U1172 - LilNCog - Lille Neuroscience & Cognition, Department of Clinical Neurophysiology, F-59000 Lille, France
6 shared publications F. Cassim
Neurophysiologie Clinique, CHRU Lille, Hôpital Roger Salengro, F‐59037 Lille cedex, France
5 shared publicationsFrançois Cassim
5 shared publications
Latest Publications
- Open Access
- 8 January 2025
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 13, e54871
Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study
Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non–laboratory-controlled conditions with actual specific and various physical activity movements. Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities. Methods: We collected HR data from participants who performed badminton, tennis, orienteering running, running, cycling, and soccer while simultaneously wearing the FC4 and the Polar H10 chest belt (criterion sensor). Skin tone was assessed with the Fitzpatrick Skin Scale. Once data from the FC4 and criterion data were synchronized, accuracy and reliability analyses were performed, using intraclass correlation coefficients (ICCs), Lin concordance correlation coefficients (CCCs), mean absolute percentage errors (MAPEs), and Bland-Altman tests. A linear univariate model was also used to evaluate the effect of skin tone on bias. All analyses were stratified by activity and pooled activity types (racket sports and running sports). Results: A total of 77.5 hours of HR recordings from 26 participants (age: mean 21.1, SD 5.8 years) were analyzed. The highest reliability was found for running sports, with ICCs and CCCs of 0.90 and 0.99 for running and 0.80 and 0.93 for orienteering running, respectively, whereas the ICCs and CCCs were 0.37 and 0.78, 0.42 and 0.88, 0.65 and 0.97, and 0.49 and 0.81 for badminton, tennis, cycling, and soccer, respectively. We found the highest accuracy for running (bias: 0.1 beats per minute [bpm]; MAPE 1.2%, SD 4.6%) and the lowest for badminton (bias: −16.5 bpm; MAPE 16.2%, SD 14.4%) and soccer (bias: −16.5 bpm; MAPE 17.5%, SD 20.8%). Limit of agreement (LOA) width and artifact rate followed the same trend. No effect of skin tone was observed on bias. Conclusions: LOA width, bias, and MAPE results found for racket sports and soccer suggest a high sensitivity to motion artifacts for activities that involve “sharp” and random arm movements. In this study, we did not measure arm motion, which limits our results. However, whereas individuals might benefit from using the FC4 for casual training in aerobic sports, we cannot recommend the use of the FC4 for specific purposes requiring high reliability and accuracy, such as research purposes.
- 8 January 2025
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 13, e54871
Open AccessReliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study
Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non–laboratory-controlled conditions with actual specific and various physical activity movements. Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities. Methods: We collected HR data from participants who performed badminton, tennis, orienteering running, running, cycling, and soccer while simultaneously wearing the FC4 and the Polar H10 chest belt (criterion sensor). Skin tone was assessed with the Fitzpatrick Skin Scale. Once data from the FC4 and criterion data were synchronized, accuracy and reliability analyses were performed, using intraclass correlation coefficients (ICCs), Lin concordance correlation coefficients (CCCs), mean absolute percentage errors (MAPEs), and Bland-Altman tests. A linear univariate model was also used to evaluate the effect of skin tone on bias. All analyses were stratified by activity and pooled activity types (racket sports and running sports). Results: A total of 77.5 hours of HR recordings from 26 participants (age: mean 21.1, SD 5.8 years) were analyzed. The highest reliability was found for running sports, with ICCs and CCCs of 0.90 and 0.99 for running and 0.80 and 0.93 for orienteering running, respectively, whereas the ICCs and CCCs were 0.37 and 0.78, 0.42 and 0.88, 0.65 and 0.97, and 0.49 and 0.81 for badminton, tennis, cycling, and soccer, respectively. We found the highest accuracy for running (bias: 0.1 beats per minute [bpm]; MAPE 1.2%, SD 4.6%) and the lowest for badminton (bias: −16.5 bpm; MAPE 16.2%, SD 14.4%) and soccer (bias: −16.5 bpm; MAPE 17.5%, SD 20.8%). Limit of agreement (LOA) width and artifact rate followed the same trend. No effect of skin tone was observed on bias. Conclusions: LOA width, bias, and MAPE results found for racket sports and soccer suggest a high sensitivity to motion artifacts for activities that involve “sharp” and random arm movements. In this study, we did not measure arm motion, which limits our results. However, whereas individuals might benefit from using the FC4 for casual training in aerobic sports, we cannot recommend the use of the FC4 for specific purposes requiring high reliability and accuracy, such as research purposes.
- 13 March 2024
- Published by Wolters Kluwer Health in Pain
- Vol. 165 (9) , 2044-2054
The influence of pain and kinesiophobia on motor control of the upper limb: how pointing task paradigms can point to new avenues of understanding
People experiencing kinesiophobia are more likely to develop persistent disabilities and chronic pain. However, the impact of kinesiophobia on the motor system remains poorly understood. We investigated whether kinesiophobia could modulate shoulder pain–induced changes in (1) kinematic parameters and muscle activation during functional movement and (2) corticospinal excitability. Thirty healthy, pain-free subjects took part in the study. Shoulder, elbow, and finger kinematics, as well as electromyographic activity of the upper trapezius and anterior deltoid muscles, were recorded while subjects performed a pointing task before and during pain induced by capsaicin at the shoulder. Anterior deltoid cortical changes in excitability were assessed through the slope of transcranial magnetic stimulation input–output curves obtained before and during pain. Results revealed that pain reduced shoulder electromyographic activity and had a variable effect on finger kinematics, with individuals with higher kinesiophobia showing greater reduction in finger target traveled distance. Kinesiophobia scores were also correlated with the changes in deltoid corticospinal excitability, suggesting that the latter can influence motor activity as soon as the motor signal emerges. Taken together, these results suggest that pain and kinesiophobia interact with motor control adaptation.
- 13 March 2024
- Published by Wolters Kluwer Health in Pain
- Vol. 165 (9) , 2044-2054
The influence of pain and kinesiophobia on motor control of the upper limb: how pointing task paradigms can point to new avenues of understanding
People experiencing kinesiophobia are more likely to develop persistent disabilities and chronic pain. However, the impact of kinesiophobia on the motor system remains poorly understood. We investigated whether kinesiophobia could modulate shoulder pain–induced changes in (1) kinematic parameters and muscle activation during functional movement and (2) corticospinal excitability. Thirty healthy, pain-free subjects took part in the study. Shoulder, elbow, and finger kinematics, as well as electromyographic activity of the upper trapezius and anterior deltoid muscles, were recorded while subjects performed a pointing task before and during pain induced by capsaicin at the shoulder. Anterior deltoid cortical changes in excitability were assessed through the slope of transcranial magnetic stimulation input–output curves obtained before and during pain. Results revealed that pain reduced shoulder electromyographic activity and had a variable effect on finger kinematics, with individuals with higher kinesiophobia showing greater reduction in finger target traveled distance. Kinesiophobia scores were also correlated with the changes in deltoid corticospinal excitability, suggesting that the latter can influence motor activity as soon as the motor signal emerges. Taken together, these results suggest that pain and kinesiophobia interact with motor control adaptation.
- Open Access
- 25 November 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Evaluation of a photoplethysmography heart rate sensor: reliability and accuracy of the Fitbit Charge 4 in ecological conditions. (Preprint)
BACKGROUND The use of wrist-worn photoplethysmography (PPG) heart rate (HR) sensors has been quickly increasing over the recent years. Wearables could be useful for researchers and individuals for their simplicity to set up and use. However, only a limited number of studies investigated the reliability and accuracy of these devices in non-laboratory controlled conditions. OBJECTIVE The purpose of this study was (1) to assess the accuracy and reliability of the PPG based HR sensor of the Fitbit Charge 4 (FC4) in ecological condition; (2) to quantify the potential variability caused by the nature of the activity. METHODS HR was simultaneously collected during various sport sessions with the FC4 and a Polar H10, as criterion. Skin tone was assessed with Fitzpatrick Scale. Intraclass correlation coefficients (ICC), Lin’s concordance correlation coefficient (CCC) and Bland-Altman test determined reliability and accuracy of the sensor. RESULTS HR data of 26 students aged 21.1±5.8 years on averaged were recorded during 77.47 hours of physical activity. ICCs (and CCCs) for running and orienteering running were 0.900 (0.999) and 0.801 (0.932) respectively, whereas for badminton, tennis, bike and soccer, they were 0.365 (0.778), 0.421 (0.884), 0.658 (0.971) and 0.487 (0.809), respectively. Highest biases were found for badminton and soccer, whereas smallest was found for running. CONCLUSIONS Researchers and individuals should not use the FC4 for measuring HR because of its LOA width and sensitivity to motion artifacts.
- 25 November 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessEvaluation of a photoplethysmography heart rate sensor: reliability and accuracy of the Fitbit Charge 4 in ecological conditions. (Preprint)
BACKGROUND The use of wrist-worn photoplethysmography (PPG) heart rate (HR) sensors has been quickly increasing over the recent years. Wearables could be useful for researchers and individuals for their simplicity to set up and use. However, only a limited number of studies investigated the reliability and accuracy of these devices in non-laboratory controlled conditions. OBJECTIVE The purpose of this study was (1) to assess the accuracy and reliability of the PPG based HR sensor of the Fitbit Charge 4 (FC4) in ecological condition; (2) to quantify the potential variability caused by the nature of the activity. METHODS HR was simultaneously collected during various sport sessions with the FC4 and a Polar H10, as criterion. Skin tone was assessed with Fitzpatrick Scale. Intraclass correlation coefficients (ICC), Lin’s concordance correlation coefficient (CCC) and Bland-Altman test determined reliability and accuracy of the sensor. RESULTS HR data of 26 students aged 21.1±5.8 years on averaged were recorded during 77.47 hours of physical activity. ICCs (and CCCs) for running and orienteering running were 0.900 (0.999) and 0.801 (0.932) respectively, whereas for badminton, tennis, bike and soccer, they were 0.365 (0.778), 0.421 (0.884), 0.658 (0.971) and 0.487 (0.809), respectively. Highest biases were found for badminton and soccer, whereas smallest was found for running. CONCLUSIONS Researchers and individuals should not use the FC4 for measuring HR because of its LOA width and sensitivity to motion artifacts.
- 1 June 2021
- Published by Wiley in European Journal of Neuroscience
- Vol. 54 (2) , 4712-4720
Late cortical disinhibition in focal hand dystonia
In writer's cramp, a form of focal hand dystonia, cortical GABAergic inhibitory mechanisms are altered and may cause involuntary tonic contractions whilst writing. The objective of this study was to explore the time course of long-interval intracortical inhibition that involves GABA-B transmission and late cortical disinhibition (that combines GABA-A and GABA-B mechanisms) in patients with writer's cramp and in control subjects. A double pulse transcranial magnetic stimulation protocol was used to evoke long-interval intracortical inhibition and late cortical disinhibition while the subjects either gripped a cylinder between their thumb and index fingers or relaxed all their upper limb muscles. We measured the ratio between primed and unprimed motor evoked potential in the first dorsal interosseous at interstimulus intervals ranging between 60ms and 300ms.Though the cortical silent period was not different between the groups, long-interval intracortical inhibition lasted longer in patients with writer’s cramp, i.e. late cortical disinhibition was delayed for more than 30ms and reached a higher level. In addition to the alteration of inhibitory mechanism mediated by GABA-B transmission, late cortical disinhibition which probably involves presynaptic inhibition is also modified in patients with writer’s cramp with possible consequences on the activity of primary motor cortex inhibitory and excitatory circuits which control the hand muscles.
- 1 June 2021
- Published by Wiley in European Journal of Neuroscience
- Vol. 54 (2) , 4712-4720
Late cortical disinhibition in focal hand dystonia
In writer's cramp, a form of focal hand dystonia, cortical GABAergic inhibitory mechanisms are altered and may cause involuntary tonic contractions whilst writing. The objective of this study was to explore the time course of long-interval intracortical inhibition that involves GABA-B transmission and late cortical disinhibition (that combines GABA-A and GABA-B mechanisms) in patients with writer's cramp and in control subjects. A double pulse transcranial magnetic stimulation protocol was used to evoke long-interval intracortical inhibition and late cortical disinhibition while the subjects either gripped a cylinder between their thumb and index fingers or relaxed all their upper limb muscles. We measured the ratio between primed and unprimed motor evoked potential in the first dorsal interosseous at interstimulus intervals ranging between 60ms and 300ms.Though the cortical silent period was not different between the groups, long-interval intracortical inhibition lasted longer in patients with writer’s cramp, i.e. late cortical disinhibition was delayed for more than 30ms and reached a higher level. In addition to the alteration of inhibitory mechanism mediated by GABA-B transmission, late cortical disinhibition which probably involves presynaptic inhibition is also modified in patients with writer’s cramp with possible consequences on the activity of primary motor cortex inhibitory and excitatory circuits which control the hand muscles.
- 1 May 2019
- Published by Elsevier in Clinical Neurophysiology
- Vol. 130 (5) , 863-875
A 15-day course of donepezil modulates spectral EEG dynamics related to target auditory stimuli in young, healthy adult volunteers
- 1 May 2019
- Published by Elsevier in Clinical Neurophysiology
- Vol. 130 (5) , 863-875
A 15-day course of donepezil modulates spectral EEG dynamics related to target auditory stimuli in young, healthy adult volunteers
- 1 April 2019
- Published by Elsevier in Neurophysiologie Clinique
- Vol. 49 (2) , 91-93
Boosting brain motor plasticity with physical exercise
- 1 April 2019
- Published by Elsevier in Neurophysiologie Clinique
- Vol. 49 (2) , 91-93
Boosting brain motor plasticity with physical exercise
- 1 September 2017
- Published by Elsevier in Annals of Physical and Rehabilitation Medicine
- Vol. 60, e83
Parietomotor connectivity in the contralesional hemisphere after stroke: A paired-pulse TMS study
- 1 September 2017
- Published by Elsevier in Annals of Physical and Rehabilitation Medicine
- Vol. 60, e83
Parietomotor connectivity in the contralesional hemisphere after stroke: A paired-pulse TMS study
- 1 June 2017
- Published by Elsevier in Neurophysiologie Clinique
- Vol. 47 (3) , 186
Connectivité pariétofrontale et mouvements de préhension chez l’homme
- 1 June 2017
- Published by Elsevier in Neurophysiologie Clinique
- Vol. 47 (3) , 186
Connectivité pariétofrontale et mouvements de préhension chez l’homme
- 1 May 2017
- Published by Elsevier in Clinical Neurophysiology
- Vol. 128 (5) , 707-715
Parietomotor connectivity in the contralesional hemisphere after stroke: A paired-pulse TMS study
- 1 May 2017
- Published by Elsevier in Clinical Neurophysiology
- Vol. 128 (5) , 707-715
Parietomotor connectivity in the contralesional hemisphere after stroke: A paired-pulse TMS study
- 1 February 2017
- Published by Elsevier in Sleep Medicine
- Vol. 30, 31-35
Reduced afferent-induced facilitation of primary motor cortex excitability in restless legs syndrome
- 1 February 2017
- Published by Elsevier in Sleep Medicine
- Vol. 30, 31-35
Reduced afferent-induced facilitation of primary motor cortex excitability in restless legs syndrome