OFOliver J. L. Fox

Oliver J. L. Fox

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oliver J. L. Fox has a total of 144 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A critical consideration of x-ray detectors based on Ga2O3: Excitation, carrier transport mechanisms, and performance standardization

    by Alfred Moore, Daniel A. Lamb, Lijie Li, Oliver Fox, Kawal Sawhney, Ciaran Llewelyn, Jon E. Evans, Saqib Rafique, Tiantian Chai, John Harrington, et al.

    X-ray detection underpins a wide range of applications in medicine, security, industrial inspection, scientific research for non-destructive imaging, and material analysis. The rapid development of Ga2O3-based x-ray detectors offers a promising pathway toward next-generation detectors with high sensitivity, low noise, and harsh environment applications, benefiting from its intrinsic material properties, such as high density, wide bandgap energy, and high thermal–chemical stability. However, the underlying device operating mechanisms, including both carrier excitation and transport processes, have not yet been adequately studied, largely due to the misuse of x-ray sources in previous studies. In addition, benchmarking of device characteristics has been problematic due to experimental or data analysis issues, as well as misunderstandings of the applied equations associated with parameter definitions. In this work, we have designed and performed instructive research based on epitaxial β–Ga2O3:Si and its planar Schottky detectors, measured with energy-tunable monochromatic x-ray beams on a synchrotron beamline, clarifying the device excitation and carrier transport mechanisms with properly benchmarked device performance. In the end, we propose a set of protocols for correctly measuring and analyzing the device performance. The proposed protocols are broadly applicable and can be readily extended to other semiconductor x-ray detectors.

  • Open Access

    The prototype DynamiX camera system – a high-frame-rate high-dynamic-range hard X-ray integrating detector for fourth-generation synchrotrons

    by Simon Knowles, Darren Ballard, Dominic Banks, Stephen Bell, Manuele Bettelli, Ivan Church, Alex Dainty, Adam Davis, Vishal Dhamgaye, Oliver Fox, et al.

    The development of fourth-generation synchrotrons, including the Diamond-II upgrade, promises 10–100× flux increases, reaching up to 10 12 photons s −1 mm −2 at the detector, across a broad range of energies from 20 to 100 keV. To exploit fully these impressive photon fluxes and high X-ray energies, readout chips must achieve high frame rates and dynamic ranges, while the use of high- Z sensor materials is essential. To address these challenges, the UK's Science and Technology Facilities Council has developed DynamiX, a test structure for a novel two-stage charge cancellation circuit on a 65 nm CMOS process with a dynamic range from single photon(s) per pixel per frame to >9000 photons per pixel per frame (10 11 –10 12 photons s −1 mm −2 ) at 20 keV photon energy. The application-specific integrated circuit has 16 ×16 pixels on 110 µm pitch and is hybridized with 2 mm thick Redlen high-flux cadmium zinc telluride (HF-CdZnTe). Data are read out at 534000 frames per second over a 14 Gbps serialiser and frames are assembled and saved with a custom data acquisition system. Measurements were made on the Diamond Light Source (DLS) B16 Test Beamline using monochromatic X-ray beams of different sizes and energies to evaluate the detector performance. A sub-pixel beam of size ∼60 µm × ∼15 µm was used to probe pixels to measure single photons with a noise performance of σ = 5.7 ± 0.1 keV. These single photons are used to calibrate the test pulse and pixel cancellation packet sizes. The linearity of the detector response under increasing flux was measured from 9 photons s −1 mm −2 at 20 keV with an r.m.s. linearity of 6.2%. A polychromatic X-ray set was used to reach higher fluxes of ∼3 × 10 10 photons s −1 mm −2 (20 keV equivalent), yielding an r.m.s. linearity of 3.2%. Finally, the full sensor area was used to image a rotating slitted disc at 534000 frames per second.

  • Novel Haemoproteus parasite lineage in Hooded Vultures (Necrosyrtes monachus) forms a distinct clade in Accipitriformes and highlights primer selection challenges in understudied avian hosts

    by Misa Shimizu, Oliver J. L. Fox, Jez Blackburn, Michael Colley, Colin Cross, Wendy James, John Jarju, Emmanuel Jatta, Naffie Sarr, Roger Walsh, et al.

    Introduction Haemoproteus spp. (Haemosporida: Haemoproteidae) are widespread avian blood parasites known for their high genetic diversity and host specificity. Haemoproteus spp. can cause internal organ damage to their vertebrate hosts, which raises concerns about their health impacts. However, the distribution of Haemoproteus spp. in Africa, particularly among non-passerine birds, remains poorly understood, with unknown implications for species conservation. Sub-Saharan Africa, including The Gambia, hosts several critically endangered vulture species, including Hooded Vultures (Necrosyrtes monachus), yet information on their haemosporidian parasites is scarce. This study aimed to identify an effective primer set for detecting Haemoproteus parasites in Hooded Vultures and to provide the first molecular confirmation of infection in this species and country. Methods Between 2019 and 2025, Hooded Vultures were blood sampled in The Gambia, and microscope slides were screened for parasites. Samples microscopically positive for Haemoproteus spp. were subjected to DNA extraction and polymerase chain reaction (PCR) analysis using different primer sets targeting the mitochondrial cytochrome b (cytb) gene. Result Of these, only UNIVF/ UNIVR3 amplified Haemoproteus spp. DNA from the Hooded Vulture samples. Sequencing and phylogenetic analyses revealed a novel Haemoproteus lineage, named hNECMON01. This represents the first molecular record of avian haemosporidian parasites in Hooded Vultures and in The Gambia. Conclusion Our findings highlight the importance of optimizing molecular tools for detecting haemosporidian parasites in non-passerine hosts and contribute to our understanding of the diversity of Haemoproteus spp. in sub-Saharan Africa. Further studies on parasite diversity in scavenging birds are essential for integrating parasite monitoring into avian conservation efforts.


  • Open Access

    Cavity Controls Core-to-Core Resonant Inelastic X-Ray Scattering

    by S.-X. Wang, Z.-Q. Zhao, X.-Y. Wang, T.-J. Li, Y. Su, Y. Uemura, F. Alves Lima, A. Khadiev, B.-H. Wang, J. M. Ablett, et al.

    X-ray cavity quantum optics with inner-shell transitions has been limited by the spectral overlap between resonant and continuum states. Here, we report the first experimental demonstration of cavity-controlled core-to-core resonant inelastic x-ray scattering (RIXS). We suppress the absorption-edge effects by monitoring the RIXS profile, thereby resolving the resonant state from the overlapping continuum. We observe distinct cavity-induced energy shifts and cavity-enhanced decay rates in the 2 p 3 d RIXS spectra of WSi 2 . These effects, manifesting as stretched or shifted profiles in the RIXS planes, enable novel spectroscopic applications via cavity-controlled core-hole states. Our results establish core-to-core RIXS as a powerful tool to manipulate inner-shell dynamics in x-ray cavities, offering new avenues for integrating quantum optical effects with x-ray spectroscopy.

  • Open Access

    Outbreak of high pathogenicity avian influenza (H5N1) in seabird populations of West Africa

    by Dembo Jatta, Michelle Wille, Mónika Z. Ballmann, Babacar N. Youm, Fagimba Camara, Tim Dodman, Oliver J.L. Fox


  • Open Access

    A study of structural effects on the focusing and imaging performance of hard X-rays with 20–30 nm zone plates

    by Xujie Tong, Vishal Dhamgaye, Qiucheng Chen, Qingxin Wu, Biao Deng, Ling Zhang, Oliver Fox, Hongchang Wang, Jun Zhao, Yifang Chen, et al.

    Hard X-ray microscopes with 20–30 nm spatial resolution ranges are an advanced tool for the inspection of materials at the nanoscale. However, the limited efficiency of the focusing optics, for example, a Fresnel zone plate (ZP) lens, can significantly reduce the power of a nanoprobe. Despite several reports on ZP lenses that focus hard X-rays with 20 nm resolution – mainly constructed by zone-doubling techniques – a systematic investigation into the limiting factors has not been reported. We report the structural effects on the focusing and imaging efficiency of 20–30 nm-resolution ZPs, employing a modified beam-propagation method. The zone width and the duty cycle (zone width/ring pitch) were optimized to achieve maximum efficiency, and a comparative analysis of the zone materials was conducted. The optimized zone structures were used in the fabrication of Pt-hydrogen silsesquioxane (HSQ) ZPs. The highest focusing efficiency of the Pt-HSQ-ZP with a resolution of 30 nm was 10% at 7 keV and >5% in the range 6–10 keV, whereas the highest efficiency of the Pt-HSQ-ZP with a resolution of 20 nm was realized at 7 keV with an efficiency of 7.6%. Optical characterization conducted at X-ray beamlines demonstrated significant enhancement of the focusing and imaging efficiency in a broader range of hard X-rays from 5 keV to 10 keV, demonstrating the potential application in hard X-ray focusing and imaging.


  • Open Access

    Alvarez varifocal X-ray lens

    by Vishal Dhamgaye, David Laundy, Hossein Khosroabadi, Thomas Moxham, Sara Baldock, Oliver Fox, Kawal Sawhney

    Visible light optical elements such as lenses and mirrors have counterparts for X-rays. In the visible regime, a variable focusing power can be achieved by an Alvarez lens which consists of a pair of inline planar refractors with a cubic thickness profile. When the two refractors are laterally displaced in opposite directions, the parabolic component of the wavefront is changed resulting in a longitudinal displacement of the focus. This paper reports an implementation of this concept for X-rays using two planar microfabricated refractive elements. The Alvarez X-ray lens can vary the focal distance of an elliptical X-ray mirror or a planar compound X-ray lens over several millimetres. The study presents the first demonstration of an Alvarez X-ray lens which adaptively corrects defocus and astigmatism aberrations of X-ray optics. In addition, the Alvarez X-ray lens eliminates coma aberration in an elliptical mirror, to the lowest order, when combining the lens with an adjustment of the pitch angle of the mirror.


  • Open Access

    Alanine response to low energy synchrotron x-ray radiation

    by P van Den Elzen, T Sander, H Palmans, M McManus, N Woodall, N Lee, O J L Fox, R M Jones, D Angal-Kalinin, A Subiel

    Objective . The radiation response of alanine is very well characterized in the MV photon energy range where it can be used to determine the dose delivered with an accuracy better than 1%, making it suitable as a secondary standard detector in cancer radiation therapy. This is not the case in the very low energy keV x-ray range where the alanine response is affected by large uncertainties and is strongly dependent on the x-ray beam energy. This motivated the study undertaken here. Approach . Alanine pellets with a nominal thickness of 0.5 mm and diameter of 5 mm were irradiated with monoenergetic x-rays at the Diamond Light Source synchrotron, to quantify their response in the 8–20 keV range relative to 60 Co radiation. The absorbed dose to graphite was measured with a small portable graphite calorimeter, and the DOSRZnrc code in the EGSnrc Monte Carlo package was used to calculate conversion factors between the measured dose to graphite and the absorbed dose to water delivered to the alanine pellets. GafChromic EBT3 films were used to measure the beam profile for modelling in the MC simulations. Main results . The relative responses measured in this energy range were found to range from 0.616 to 0.643, with a combined relative expanded uncertainty of 3.4%–3.5% ( k = 2), where the majority of the uncertainty originated from the uncertainty in the alanine readout, due to the small size of the pellets used. Significance . The measured values were in good agreement with previously published data in the overlapping region of x-ray energies, while this work extended the dataset to lower energies. By measuring the response to monoenergetic x-rays, the response to a more complex broad-spectrum x-ray source can be inferred if the spectrum is known, meaning that this work supports the establishment of alanine as a secondary standard dosimeter for low-energy x-ray sources.


  • Open Access

    Two-dimensional speckle technique for slope error measurements of weakly focusing reflective X-ray optics

    by Lingfei Hu, Hongchang Wang, Oliver Fox, Kawal Sawhney

    Speckle-based at-wavelength metrology techniques now play an important role in X-ray wavefront measurements. However, for reflective X-ray optics, the majority of existing speckle-based methods fail to provide reliable 2D information about the optical surface being characterized. Compared with the 1D information typically output from speckled-based methods, a 2D map is more informative for understanding the overall quality of the optic being tested. In this paper, we propose a method for in situ 2D absolute metrology of weakly focusing X-ray mirrors. Importantly, the angular misalignment of the mirror can be easily corrected with the proposed 2D processing procedure. We hope the speckle pattern data processing method presented here will help to extend this technique to wider applications in the synchrotron radiation and X-ray free-electron laser communities.